메뉴 건너뛰기




Volumn 38, Issue 6, 2014, Pages 456-468

Reproduction of continuous flow left ventricular assist device experimental data by means of a hybrid cardiovascular model with baroreflex control

Author keywords

Baroreflex; Hybrid cardiovascular simulator; Hydronumerical; Impedance transformer; Left ventricular assist device; Lumped parameter model

Indexed keywords

ANIMALS; FIBER OPTIC SENSORS; LEFT VENTRICULAR ASSIST DEVICES; LUMPED PARAMETER NETWORKS; PHYSIOLOGICAL MODELS; PHYSIOLOGY; UNLOADING;

EID: 84901915154     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/aor.12178     Document Type: Article
Times cited : (35)

References (31)
  • 1
    • 58249094014 scopus 로고    scopus 로고
    • Partial left ventricular support implanted through minimal access surgery as a bridge to cardiac transplant
    • Meyns B, Rega P, Ector J, etal. Partial left ventricular support implanted through minimal access surgery as a bridge to cardiac transplant. J Thorac Cardiovasc Surg 2009;137:243-245.
    • (2009) J Thorac Cardiovasc Surg , vol.137 , pp. 243-245
    • Meyns, B.1    Rega, P.2    Ector, J.3
  • 2
    • 79954589537 scopus 로고    scopus 로고
    • Clinical benefits of partial circulatory support in New York Heart Association Class IIIb and Early Class IV patients
    • Meyns B, Simon A, Klotz S, etal. Clinical benefits of partial circulatory support in New York Heart Association Class IIIb and Early Class IV patients. Eur J Cardiothorac Surg 2011;39:693-698.
    • (2011) Eur J Cardiothorac Surg , vol.39 , pp. 693-698
    • Meyns, B.1    Simon, A.2    Klotz, S.3
  • 3
    • 84865446920 scopus 로고    scopus 로고
    • Patients with continuous-flow left ventricular assist devices provide insight in human baroreflex physiology
    • Tank J, Heusser K, Malehsa D, etal. Patients with continuous-flow left ventricular assist devices provide insight in human baroreflex physiology. Hypertension 2012;60:849-855.
    • (2012) Hypertension , vol.60 , pp. 849-855
    • Tank, J.1    Heusser, K.2    Malehsa, D.3
  • 4
    • 85128513888 scopus 로고    scopus 로고
    • Feedback control of an LVAD supporting a failing cardiovascular system regulated by the baroreflex
    • Proceedings of the 45th IEEE Conference on Decision & Control. San Diego, CA, USA, Dec 13-15
    • Chen S, Ferreira A, Simaan MA, Boston JR, Antaki JF. Feedback control of an LVAD supporting a failing cardiovascular system regulated by the baroreflex. Proceedings of the 45th IEEE Conference on Decision & Control. San Diego, CA, USA, Dec 13-15, 2006.
    • (2006)
    • Chen, S.1    Ferreira, A.2    Simaan, M.A.3    Boston, J.R.4    Antaki, J.F.5
  • 5
    • 67650786759 scopus 로고    scopus 로고
    • Analysis of baroreflex sensitivity during undulation pump ventricular assist device support
    • Liu H, Shiraishi Y, Zhang X, etal. Analysis of baroreflex sensitivity during undulation pump ventricular assist device support. Artif Organs 2009;33:561-565.
    • (2009) Artif Organs , vol.33 , pp. 561-565
    • Liu, H.1    Shiraishi, Y.2    Zhang, X.3
  • 6
    • 0034759322 scopus 로고    scopus 로고
    • Analysis of sympathetic nerve activity in end-stage cardiomyopathy patients receiving left ventricular support
    • Miyagawa S, Sawa Y, Fukushima N, etal. Analysis of sympathetic nerve activity in end-stage cardiomyopathy patients receiving left ventricular support. J Heart Lung Transplant 2001;20:1181-1187.
    • (2001) J Heart Lung Transplant , vol.20 , pp. 1181-1187
    • Miyagawa, S.1    Sawa, Y.2    Fukushima, N.3
  • 7
    • 34548533481 scopus 로고    scopus 로고
    • Numerical simulation of cardiovascular dynamics with different types of VAD assistance
    • Shi Y, Korakianitis T, Bowles C. Numerical simulation of cardiovascular dynamics with different types of VAD assistance. J Biomech 2007;40:2919-2933.
    • (2007) J Biomech , vol.40 , pp. 2919-2933
    • Shi, Y.1    Korakianitis, T.2    Bowles, C.3
  • 8
  • 10
    • 84857980483 scopus 로고    scopus 로고
    • A mock circulatory system with physiological distribution of terminal resistance and compliance: application for testing the intra-aortic balloon pump
    • Kolyva C, Biglino G, Pepper JR, Khir AW. A mock circulatory system with physiological distribution of terminal resistance and compliance: application for testing the intra-aortic balloon pump. Artif Organs 2012;36:E62-70.
    • (2012) Artif Organs , vol.36
    • Kolyva, C.1    Biglino, G.2    Pepper, J.R.3    Khir, A.W.4
  • 12
    • 0034744380 scopus 로고    scopus 로고
    • Elastance-based control of a mock circulatory system
    • Baloa LA, Boston JR, Antaki JF. Elastance-based control of a mock circulatory system. Ann Biomed Eng 2001;29:244-251.
    • (2001) Ann Biomed Eng , vol.29 , pp. 244-251
    • Baloa, L.A.1    Boston, J.R.2    Antaki, J.F.3
  • 13
    • 27544470251 scopus 로고    scopus 로고
    • Hybrid test bench for evaluation of any device related to mechanical cardiac assistance
    • Colacino FM, Arabia M, Danieli GA, etal. Hybrid test bench for evaluation of any device related to mechanical cardiac assistance. Int J Artif Organs 2005;28:817-826.
    • (2005) Int J Artif Organs , vol.28 , pp. 817-826
    • Colacino, F.M.1    Arabia, M.2    Danieli, G.A.3
  • 14
    • 84872559364 scopus 로고    scopus 로고
    • Novel interface for hybrid mock circulations to evaluate ventricular assist devices
    • Ochsner G, Amacher R, Amstutz A, etal. Novel interface for hybrid mock circulations to evaluate ventricular assist devices. IEEE Trans Biomed Eng 2012;60:507-516.
    • (2012) IEEE Trans Biomed Eng , vol.60 , pp. 507-516
    • Ochsner, G.1    Amacher, R.2    Amstutz, A.3
  • 15
    • 84871825648 scopus 로고    scopus 로고
    • A hybrid (Hydro-numerical) cardiovascular model: application to investigate continuous-flow pump assistance effect
    • Kozarski M, Ferrari G, Zieliński K, etal. A hybrid (Hydro-numerical) cardiovascular model: application to investigate continuous-flow pump assistance effect. Biocybern Biomed Eng 2012;32:77-91.
    • (2012) Biocybern Biomed Eng , vol.32 , pp. 77-91
    • Kozarski, M.1    Ferrari, G.2    Zieliński, K.3
  • 16
    • 84858630052 scopus 로고    scopus 로고
    • A modular computational circulatory model applicable to VAD testing and training
    • Ferrari G, Kozarski M, Zieliński K, etal. A modular computational circulatory model applicable to VAD testing and training. J Artif Organs 2012;15:32-43.
    • (2012) J Artif Organs , vol.15 , pp. 32-43
    • Ferrari, G.1    Kozarski, M.2    Zieliński, K.3
  • 17
    • 84874709766 scopus 로고    scopus 로고
    • Effects of intra-aortic balloon pump timing on baroreflex activities in a closed-loop cardiovascular hybrid model
    • Fresiello L, Khir AW, Di Molfetta A, Kozarski M, Ferrari G. Effects of intra-aortic balloon pump timing on baroreflex activities in a closed-loop cardiovascular hybrid model. Artif Organs 2013;37:237-247.
    • (2013) Artif Organs , vol.37 , pp. 237-247
    • Fresiello, L.1    Khir, A.W.2    Di Molfetta, A.3    Kozarski, M.4    Ferrari, G.5
  • 19
    • 0003895703 scopus 로고
    • Chamber pressure-volume relation versus muscle tension-length relaxation
    • Sagawa K, Maughan L, Suga H, Sunagawa K, eds. New York: Oxford University Press
    • Sagawa K, Maughan L, Suga H, Sunagawa K. Chamber pressure-volume relation versus muscle tension-length relaxation. In: Sagawa K, Maughan L, Suga H, Sunagawa K, eds. Cardiac Contraction and the Pressure-Volume Relationship. New York: Oxford University Press, 1988;61-94.
    • (1988) Cardiac Contraction and the Pressure-Volume Relationship , pp. 61-94
    • Sagawa, K.1    Maughan, L.2    Suga, H.3    Sunagawa, K.4
  • 20
    • 16244372049 scopus 로고    scopus 로고
    • Assessment of left ventricular parameters using 16-MDCT and new software for endocardial and epicardial border delineation
    • Schlosser T, Pagonidis K, Herborn CU, etal. Assessment of left ventricular parameters using 16-MDCT and new software for endocardial and epicardial border delineation. AJR Am J Roentgenol 2005;184:765-773.
    • (2005) AJR Am J Roentgenol , vol.184 , pp. 765-773
    • Schlosser, T.1    Pagonidis, K.2    Herborn, C.U.3
  • 22
    • 80052666817 scopus 로고    scopus 로고
    • Hybrid model analysis of intra-aortic balloon pump performance as a function of ventricular and circulatory parameters
    • Ferrari G, Khir AW, Fresiello L, Di Molfetta A, Kozarski M. Hybrid model analysis of intra-aortic balloon pump performance as a function of ventricular and circulatory parameters. Artif Organs 2011;35:902-911.
    • (2011) Artif Organs , vol.35 , pp. 902-911
    • Ferrari, G.1    Khir, A.W.2    Fresiello, L.3    Di Molfetta, A.4    Kozarski, M.5
  • 23
    • 0036095682 scopus 로고    scopus 로고
    • Computational modeling of cardiovascular response to orthostatic stress
    • Heldt T, Shim EB, Kamm RD, Mark RG. Computational modeling of cardiovascular response to orthostatic stress. J Appl Physiol 2002;92:1239-1254.
    • (2002) J Appl Physiol , vol.92 , pp. 1239-1254
    • Heldt, T.1    Shim, E.B.2    Kamm, R.D.3    Mark, R.G.4
  • 24
    • 50649103688 scopus 로고    scopus 로고
    • A new hybrid electro-numerical model of the left ventricle
    • Kozarski M, Ferrari G, Zieliński K, etal. A new hybrid electro-numerical model of the left ventricle. Comput Biol Med 2008;38:979-989.
    • (2008) Comput Biol Med , vol.38 , pp. 979-989
    • Kozarski, M.1    Ferrari, G.2    Zieliński, K.3
  • 25
    • 33750694324 scopus 로고    scopus 로고
    • Interaction between carotid baroregulation and the pulsating heart: a mathematical model
    • Ursino M. Interaction between carotid baroregulation and the pulsating heart: a mathematical model. Am J Physiol 1998;275:1733-1747.
    • (1998) Am J Physiol , vol.275 , pp. 1733-1747
    • Ursino, M.1
  • 26
    • 0016665085 scopus 로고
    • Baroreceptor reflex control of arterial hemodynamics in the dog
    • Cox RH, Bagshaw RJ. Baroreceptor reflex control of arterial hemodynamics in the dog. Circ Res 1975;37:772-786.
    • (1975) Circ Res , vol.37 , pp. 772-786
    • Cox, R.H.1    Bagshaw, R.J.2
  • 27
    • 84931012864 scopus 로고
    • Effects of graded pulsatile pressure on the reflex vasomotor responses elicited by changes of mean pressure in the perfused carotid sinus-aortic arch regions of the dog
    • Angell James JE, Daly Mde B. Effects of graded pulsatile pressure on the reflex vasomotor responses elicited by changes of mean pressure in the perfused carotid sinus-aortic arch regions of the dog. J Physiol 1971;214:51-64.
    • (1971) J Physiol , vol.214 , pp. 51-64
    • Angell James, J.E.1    Daly Mde, B.2
  • 28
    • 0018853169 scopus 로고
    • Epinephrine and the carotid sinus baroreceptor reflex. Influence on capacitive and resistive properties of the total systemic vascular bed of the dog
    • Shoukas AA, Brunner MC. Epinephrine and the carotid sinus baroreceptor reflex. Influence on capacitive and resistive properties of the total systemic vascular bed of the dog. Circ Res 1980;47:249-257.
    • (1980) Circ Res , vol.47 , pp. 249-257
    • Shoukas, A.A.1    Brunner, M.C.2
  • 29
    • 0019349808 scopus 로고
    • The effect of the carotid sinus baroreceptor reflex on blood flow and volume redistribution in the total systemic vascular bed of the dog
    • Brunner MJ, Shoukas AA, Macanespie CL. The effect of the carotid sinus baroreceptor reflex on blood flow and volume redistribution in the total systemic vascular bed of the dog. Circ Res 1981;48:274-285.
    • (1981) Circ Res , vol.48 , pp. 274-285
    • Brunner, M.J.1    Shoukas, A.A.2    Macanespie, C.L.3
  • 31
    • 0030200518 scopus 로고    scopus 로고
    • The role of pressure pulsatility in the carotid baroreflex control: a computer simulation study
    • Ursino M, Fiorenzi A, Belardinelli E. The role of pressure pulsatility in the carotid baroreflex control: a computer simulation study. Comput Biol Med 1996;26:297-314.
    • (1996) Comput Biol Med , vol.26 , pp. 297-314
    • Ursino, M.1    Fiorenzi, A.2    Belardinelli, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.