메뉴 건너뛰기




Volumn , Issue , 2011, Pages 401-480

The tensiograph platform for optical measurement

Author keywords

[No Author keywords available]

Indexed keywords


EID: 84901622042     PISSN: None     EISSN: None     Source Type: Book    
DOI: None     Document Type: Chapter
Times cited : (1)

References (60)
  • 1
    • 77957086199 scopus 로고    scopus 로고
    • From stalagmometry to multianalyser tensiography:The definition of the instrumental, software and analytical requirements for a new departure in drop analysis
    • Series Studies in Interface Science, D. Möbius and R. Miller (Eds), Elsevier
    • N.D. McMillan, V. Lawlor, M. Baker and S. Smith, From stalagmometry to multianalyser tensiography:The definition of the instrumental, software and analytical requirements for a new departure in drop analysis, in “Drops and Bubbles in Interfacial Research”, Vol. 6, Series Studies in Interface Science, D. Möbius and R. Miller (Eds), Elsevier, 1998, pp. 593-705.
    • (1998) Drops and Bubbles in Interfacial Research , vol.6 , pp. 593-705
    • McMillan, N.D.1    Lawlor, V.2    Baker, M.3    Smith, S.4
  • 3
    • 0001389794 scopus 로고
    • Rayleigh, Phil. Mag., 48 (1899) 321.
    • (1899) Phil. Mag. , vol.48 , pp. 321
  • 10
    • 85059418341 scopus 로고
    • CCD camera method of analysing the property of liquids
    • N.D. McMillan, CCD camera method of analysing the property of liquids, Irish Provisional Patent (1987).
    • (1987) Irish Provisional Patent
    • McMillan, N.D.1
  • 16
    • 85059418331 scopus 로고    scopus 로고
    • The Singapore Institute of Manufacturing Technology produced a Multispectral Liquid Drop Analyser
    • The Singapore Institute of Manufacturing Technology produced a Multispectral Liquid Drop Analyser in 2003.
    • (2003)
  • 29
    • 85059392193 scopus 로고    scopus 로고
    • PhD thesis, Dublin Institute of Technology, Dublin
    • K. Tiernan, “Drop spectrophotometer design”, PhD thesis, Dublin Institute of Technology, Dublin, 2007.
    • (2007) Drop spectrophotometer design
    • Tiernan, K.1
  • 31
    • 85059411951 scopus 로고    scopus 로고
    • Analytical Instrumentation Performance Characteristics and Quality, Wiley
    • G. Currell, Analytical Instrumentation Performance Characteristics and Quality, Wiley, 2000.
    • (2000)
    • Currell, G.1
  • 43
    • 85059398553 scopus 로고
    • APHA, 19th Edition
    • US Standard Methods for the Examination ofWater andWastewater, APHA, 19th Edition (1995).
    • (1995)
  • 44
    • 85059374255 scopus 로고    scopus 로고
    • Method 10068, Hach DR/2010 Spectrophotometer Handbook
    • Method 10068, Hach DR/2010 Spectrophotometer Handbook.
  • 45
  • 50
    • 85059427837 scopus 로고    scopus 로고
    • PhD thesis, Carlow Institute of Technology, Carlow, due for submission
    • P. Pringuet, “Tensiotrace modeling”, PhD thesis, Carlow Institute of Technology, Carlow, due for submission, 2009.
    • (2009) Tensiotrace modeling
    • Pringuet, P.1
  • 55
    • 85059411281 scopus 로고    scopus 로고
    • ISO 17025 or ISO 9000. Starna standards provide “evidence of control” that has become an absolute necessity as indeed has the use of Certified Reference Materials with a defined traceable path to national or internationally recognised primary materials or procedures. See for example
    • CRM for UV and fluorescence spectroscopy requirement for laboratories for accreditation for at least one of the internationally recognised standards of GLP, ISO 17025 or ISO 9000. Starna standards provide “evidence of control” that has become an absolute necessity as indeed has the use of Certified Reference Materials with a defined traceable path to national or internationally recognised primary materials or procedures. See for example http://www.starna.co.uk/ukhome/d_ref/f_ref/scientistarticle.html.
  • 57
    • 85059381124 scopus 로고    scopus 로고
    • from Eljen Technology, PO Box 870, 300 Crane Street, Sweetwater TX 79556 USA, Website, This product appears to have been changed from the hydrocarbon to a polymeric fluorescence standard for safety reasons in very recent times. The author’s work has shown discrepancies in measurement from those shown on data sheet and conclusions given in the text probably need to be revisited
    • EJ-309 Liquid Scintillator from Southern Scientific Ltd. from Eljen Technology, PO Box 870, 300 Crane Street, Sweetwater TX 79556 USA, Website: www.eljentechnology.com. This product appears to have been changed from the hydrocarbon to a polymeric fluorescence standard for safety reasons in very recent times. The author’s work has shown discrepancies in measurement from those shown on data sheet and conclusions given in the text probably need to be revisited.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.