메뉴 건너뛰기




Volumn 28, Issue 5, 2014, Pages

Low-dose spiral CT screening and evaluation of the solitary pulmonary nodule

Author keywords

[No Author keywords available]

Indexed keywords

ADENOCARCINOMA; ALGORITHM; DIFFERENTIAL DIAGNOSIS; GROWTH RATE; HISTOLOGY; HUMAN; LUNG CANCER; LUNG NODULE; MALIGNANT NODULE DIAMETER; ONCOLOGICAL PARAMETERS; PATIENT CARE; POSITRON EMISSION TOMOGRAPHY; PREDICTION; QUANTITATIVE ASSAY; RADIODIAGNOSIS; RANDOMIZED CONTROLLED TRIAL (TOPIC); REVIEW; SPIRAL COMPUTER ASSISTED TOMOGRAPHY; SQUAMOUS CELL CARCINOMA;

EID: 84901008990     PISSN: 08909091     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (14)

References (40)
  • 1
    • 33745246057 scopus 로고    scopus 로고
    • Extended lung cancer incidence follow-up in the Mayo Lung Project and overdiagnosis
    • Marcus PM, Bergstralh EJ, Zweig MH, et al. Extended lung cancer incidence follow-up in the Mayo Lung Project and overdiagnosis. J Natl Cancer Inst. 2006;98:748-56.
    • (2006) J Natl Cancer Inst. , vol.98 , pp. 748-756
    • Marcus, P.M.1    Bergstralh, E.J.2    Zweig, M.H.3
  • 2
    • 0042831259 scopus 로고    scopus 로고
    • Screening for lung cancer: A systematic review and meta-analysis of controlled trials
    • Manser RL, Irving LB, Byrnes G, et al. Screening for lung cancer: a systematic review and meta-analysis of controlled trials. Thorax. 2003;58:784-9.
    • (2003) Thorax. , vol.58 , pp. 784-789
    • Manser, R.L.1    Irving, L.B.2    Byrnes, G.3
  • 4
    • 84863229324 scopus 로고    scopus 로고
    • The National Lung Screening Trial: Overview and study design
    • Aberle DR, Berg CD, Black WC, et al. The National Lung Screening Trial: overview and study design. Radiology 2011;258:243-53.
    • (2011) Radiology , vol.258 , pp. 243-253
    • Aberle, D.R.1    Berg, C.D.2    Black, W.C.3
  • 5
    • 79961108629 scopus 로고    scopus 로고
    • Reduced lung-cancer mortality with low-dose computed tomographic screening
    • Aberle DR, Adams AM, Berg CD, et al. Reduced lung-cancer mortality with low-dose computed tomographic screening. N Engl J Med. 2011;365:395-409.
    • (2011) N Engl J Med. , vol.365 , pp. 395-409
    • Aberle, D.R.1    Adams, A.M.2    Berg, C.D.3
  • 6
    • 84872677407 scopus 로고    scopus 로고
    • Complications following lung surgery in the Dutch-Belgian randomized lung cancer screening trial
    • Van't Westeinde SC, Horeweg N, De Leyn P, et al. Complications following lung surgery in the Dutch-Belgian randomized lung cancer screening trial. Eur J Cardiothorac Surg. 2012;42:420-9.
    • (2012) Eur J Cardiothorac Surg. , vol.42 , pp. 420-429
    • Van't Westeinde, S.C.1    Horeweg, N.2    De Leyn, P.3
  • 7
    • 84862255365 scopus 로고    scopus 로고
    • Benefits and harms of CT screening for lung cancer: A systematic review
    • Bach PB, Mirkin JN, Oliver TK, et al. Benefits and harms of CT screening for lung cancer: a systematic review. JAMA. 2012;307:2418-29.
    • (2012) JAMA. , vol.307 , pp. 2418-2429
    • Bach, P.B.1    Mirkin, J.N.2    Oliver, T.K.3
  • 8
    • 0036109223 scopus 로고    scopus 로고
    • CT screening for lung cancer: Frequency and significance of part-solid and nonsolid nodules
    • Henschke CI, Yankelevitz DF, Mirtcheva R, et al. CT screening for lung cancer: frequency and significance of part-solid and nonsolid nodules. AJR Am J Roentgenol. 2002;178:1053-7.
    • (2002) AJR Am J Roentgenol. , vol.178 , pp. 1053-1057
    • Henschke, C.I.1    Yankelevitz, D.F.2    Mirtcheva, R.3
  • 9
    • 0037865723 scopus 로고    scopus 로고
    • Clinical practice. The solitary pulmonary nodule
    • Ost D, Fein AM, Feinsilver SH. Clinical practice. The solitary pulmonary nodule. N Engl J Med. 2003;348:2535-42.
    • (2003) N Engl J Med. , vol.348 , pp. 2535-2542
    • Ost, D.1    Fein, A.M.2    Feinsilver, S.H.3
  • 10
    • 0019352520 scopus 로고
    • Solitary pulmonary nodules due to nontuberculous mycobacterial infection
    • Gribetz AR, Damsker B, Bottone EJ, et al. Solitary pulmonary nodules due to nontuberculous mycobacterial infection. Am J Med. 1981;70:39-43.
    • (1981) Am J Med. , vol.70 , pp. 39-43
    • Gribetz, A.R.1    Damsker, B.2    Bottone, E.J.3
  • 11
    • 0023029924 scopus 로고
    • Pneumocystis carinii pneumonia presenting as cavitating and noncavitating solitary pulmonary nodules in patients with the acquired immunodeficiency syndrome
    • Barrio JL, Suarez M, Rodriguez JL, et al. Pneumocystis carinii pneumonia presenting as cavitating and noncavitating solitary pulmonary nodules in patients with the acquired immunodeficiency syndrome. Am Rev Respir Dis. 1986;134:1094-6.
    • (1986) Am Rev Respir Dis. , vol.134 , pp. 1094-1096
    • Barrio, J.L.1    Suarez, M.2    Rodriguez, J.L.3
  • 12
    • 0020661766 scopus 로고
    • The coin lesion of the lung. A review of 955 resected coin lesions
    • Toomes H, Delphendahl A, Manke HG, Vogt-Moykopf I. The coin lesion of the lung. A review of 955 resected coin lesions. Cancer. 1983;51:534-7.
    • (1983) Cancer. , vol.51 , pp. 534-537
    • Toomes, H.1    Delphendahl, A.2    Manke, H.G.3    Vogt-Moykopf, I.4
  • 13
    • 84880560754 scopus 로고    scopus 로고
    • Targeting of low-dose CT screening according to the risk of lung-cancer death
    • Kovalchik SA, Tammemagi M, Berg CD, et al. Targeting of low-dose CT screening according to the risk of lung-cancer death. N Engl J Med. 2013;369:245-54.
    • (2013) N Engl J Med. , vol.369 , pp. 245-254
    • Kovalchik, S.A.1    Tammemagi, M.2    Berg, C.D.3
  • 14
  • 15
    • 80455177301 scopus 로고    scopus 로고
    • The use and misuse of positron emission tomography in lung cancer evaluation
    • Chang CF, Rashtian A, Gould MK. The use and misuse of positron emission tomography in lung cancer evaluation. Clin Chest Med. 2011;32:749-62.
    • (2011) Clin Chest Med. , vol.32 , pp. 749-762
    • Chang, C.F.1    Rashtian, A.2    Gould, M.K.3
  • 16
    • 38949114184 scopus 로고    scopus 로고
    • A comparison of the diagnostic accuracy of 18F-FDG PET and CT in the characterization of solitary pulmonary nodules
    • Fletcher JW, Kymes SM, Gould M, et al. A comparison of the diagnostic accuracy of 18F-FDG PET and CT in the characterization of solitary pulmonary nodules. J Nucl Med. 2008;49:179-85.
    • (2008) J Nucl Med. , vol.49 , pp. 179-185
    • Fletcher, J.W.1    Kymes, S.M.2    Gould, M.3
  • 17
    • 79953008658 scopus 로고    scopus 로고
    • Combined use of positron emission tomography and volume doubling time in lung cancer screening with low-dose CT scanning
    • Ashraf H, Dirksen A, Loft A, et al. Combined use of positron emission tomography and volume doubling time in lung cancer screening with low-dose CT scanning. Thorax. 2011;66:315-9.
    • (2011) Thorax. , vol.66 , pp. 315-319
    • Ashraf, H.1    Dirksen, A.2    Loft, A.3
  • 18
    • 79952340035 scopus 로고    scopus 로고
    • Differentiation of malignant and benign pulmonary nodules with quantitative first-pass 320-detector row perfusion CT versus FDG PET/CT
    • Ohno Y, Koyama H, Matsumoto K, et al. Differentiation of malignant and benign pulmonary nodules with quantitative first-pass 320-detector row perfusion CT versus FDG PET/CT. Radiology. 2011;258:599-609.
    • (2011) Radiology. , vol.258 , pp. 599-609
    • Ohno, Y.1    Koyama, H.2    Matsumoto, K.3
  • 19
    • 0033825783 scopus 로고    scopus 로고
    • Evaluation and management of the solitary pulmonary nodule
    • Ost D, Fein A. Evaluation and management of the solitary pulmonary nodule. Am J Respir Crit Care Med. 2000;162:782-7.
    • (2000) Am J Respir Crit Care Med. , vol.162 , pp. 782-787
    • Ost, D.1    Fein, A.2
  • 21
    • 16544381878 scopus 로고    scopus 로고
    • Malignant versus benign nodules at CT screening for lung cancer: Comparison of thin-section CT findings
    • Li F, Sone S, Abe H, et al. Malignant versus benign nodules at CT screening for lung cancer: comparison of thin-section CT findings. Radiology. 2004;233:793-8.
    • (2004) Radiology. , vol.233 , pp. 793-798
    • Li, F.1    Sone, S.2    Abe, H.3
  • 22
    • 84883373200 scopus 로고    scopus 로고
    • Probability of cancer in pulmonary nodules detected on first screening CT
    • McWilliams A, Tammemagi MC, Mayo JR, et al. Probability of cancer in pulmonary nodules detected on first screening CT. N Engl J Med. 2013;369:910-19.
    • (2013) N Engl J Med. , vol.369 , pp. 910-919
    • McWilliams, A.1    Tammemagi, M.C.2    Mayo, J.R.3
  • 23
    • 36249031144 scopus 로고    scopus 로고
    • Pulmonary nodules: 3D volumetric measurement with multidetector CT-effect of intravenous contrast medium
    • Honda O, Johkoh T, Sumikawa H, et al. Pulmonary nodules: 3D volumetric measurement with multidetector CT-effect of intravenous contrast medium. Radiology. 2007;245:881-7.
    • (2007) Radiology. , vol.245 , pp. 881-887
    • Honda, O.1    Johkoh, T.2    Sumikawa, H.3
  • 24
    • 84555206076 scopus 로고    scopus 로고
    • International Association for the Study of Lung Cancer Computed Tomography Screening Workshop 2011 report
    • Field JK, Smith RA, Aberle DR, et al. International Association for the Study of Lung Cancer Computed Tomography Screening Workshop 2011 report. J Thorac Oncol. 2012;7:10-19.
    • (2012) J Thorac Oncol. , vol.7 , pp. 10-19
    • Field, J.K.1    Smith, R.A.2    Aberle, D.R.3
  • 25
  • 26
    • 0017370580 scopus 로고
    • An overview of cancer of the lung
    • Rigler LG. An overview of cancer of the lung. Semin Roentgenol. 1977;12:161-4.
    • (1977) Semin Roentgenol. , vol.12 , pp. 161-164
    • Rigler, L.G.1
  • 27
    • 0022480622 scopus 로고
    • CT of the pulmonary nodule: A cooperative study
    • Zerhouni EA, Stitik FP, Siegelman SS, et al. CT of the pulmonary nodule: a cooperative study. Radiology. 1986;160:319-27.
    • (1986) Radiology. , vol.160 , pp. 319-327
    • Zerhouni, E.A.1    Stitik, F.P.2    Siegelman, S.S.3
  • 28
    • 0031403024 scopus 로고    scopus 로고
    • The probability of malignancy in solitary pulmonary nodules. Application to small radiologically indeterminate nodules
    • Swensen SJ, Silverstein MD, Ilstrup DM, et al. The probability of malignancy in solitary pulmonary nodules. Application to small radiologically indeterminate nodules. Arch Intern Med. 1997;157:849-55.
    • (1997) Arch Intern Med. , vol.157 , pp. 849-855
    • Swensen, S.J.1    Silverstein, M.D.2    Ilstrup, D.M.3
  • 29
    • 33847167612 scopus 로고    scopus 로고
    • A clinical model to estimate the pretest probability of lung cancer in patients with solitary pulmonary nodules
    • Gould MK, Ananth L, Barnett PG. A clinical model to estimate the pretest probability of lung cancer in patients with solitary pulmonary nodules. Chest. 2007;131:383-8.
    • (2007) Chest. , vol.131 , pp. 383-388
    • Gould, M.K.1    Ananth, L.2    Barnett, P.G.3
  • 30
    • 84896693638 scopus 로고    scopus 로고
    • The utility of nodule volume in the context of malignancy prediction for small pulmonary nodules
    • Mehta HJ, Ravenel JG, Shaftman SR, et al. The utility of nodule volume in the context of malignancy prediction for small pulmonary nodules. Chest. 2014;145:464-72.
    • (2014) Chest. , vol.145 , pp. 464-472
    • Mehta, H.J.1    Ravenel, J.G.2    Shaftman, S.R.3
  • 31
    • 0022531545 scopus 로고
    • Estimating the probability of malignancy in solitary pulmonary nodules. A Bayesian approach
    • Cummings SR, Lillington GA, Richard RJ. Estimating the probability of malignancy in solitary pulmonary nodules. A Bayesian approach. Am Rev Respir Dis. 1986;134:449-52.
    • (1986) Am Rev Respir Dis. , vol.134 , pp. 449-452
    • Cummings, S.R.1    Lillington, G.A.2    Richard, R.J.3
  • 32
    • 84876829673 scopus 로고    scopus 로고
    • Characteristics of lung cancers detected by computer tomography screening in the randomized NELSON trial
    • Horeweg N, van der Aalst CM, Thunnissen E, et al. Characteristics of lung cancers detected by computer tomography screening in the randomized NELSON trial. Am J Respir Crit Care Med. 2013;187:848-54.
    • (2013) Am J Respir Crit Care Med. , vol.187 , pp. 848-854
    • Horeweg, N.1    van der Aalst, C.M.2    Thunnissen, E.3
  • 33
    • 84886944999 scopus 로고    scopus 로고
    • Volumetric computed tomography screening for lung cancer: Three rounds of the NELSON trial
    • Horeweg N, van der Aalst CM, Vliegenthart R, et al. Volumetric computed tomography screening for lung cancer: three rounds of the NELSON trial. Eur Respir J. 2013;42:1659-67.
    • (2013) Eur Respir J. , vol.42 , pp. 1659-1667
    • Horeweg, N.1    van der Aalst, C.M.2    Vliegenthart, R.3
  • 34
    • 84877669189 scopus 로고    scopus 로고
    • Evaluation of individuals with pulmonary nodules: When is it lung cancer? Diagnosis and management of lung cancer, 3rd ed. American College of Chest Physicians evidence-based clinical practice guidelines
    • Gould MK, Donington J, Lynch WR, et al. Evaluation of individuals with pulmonary nodules: When is it lung cancer? Diagnosis and management of lung cancer, 3rd ed. American College of Chest Physicians evidence-based clinical practice guidelines. Chest. 2013;143:e93S-120S.
    • (2013) Chest. , vol.143
    • Gould, M.K.1    Donington, J.2    Lynch, W.R.3
  • 35
    • 27144449606 scopus 로고    scopus 로고
    • Guidelines for management of small pulmonary nodules detected on CT scans: A statement from the Fleischner Society
    • MacMahon H, Austin JH, Gamsu G, et al. Guidelines for management of small pulmonary nodules detected on CT scans: a statement from the Fleischner Society. Radiology. 2005;237:395-400.
    • (2005) Radiology. , vol.237 , pp. 395-400
    • McMahon, H.1    Austin, J.H.2    Gamsu, G.3
  • 36
    • 75549120910 scopus 로고
    • The solitary pulmonary nodule. Report of a cooperative study of resected asymptomatic solitary pulmonary nodules in males
    • Steele JD. The solitary pulmonary nodule. Report of a cooperative study of resected asymptomatic solitary pulmonary nodules in males. J Thorac Cardiovasc Surg. 1963;46:21-39.
    • (1963) J Thorac Cardiovasc Surg. , vol.46 , pp. 21-39
    • Steele, J.D.1
  • 37
    • 84893557385 scopus 로고    scopus 로고
    • Overdiagnosis in low-dose computed tomography screening for lung cancer
    • Patz EF, Jr, Pinsky P, Gatsonis C, et al. Overdiagnosis in low-dose computed tomography screening for lung cancer. JAMA Intern Med. 2014;174:269-74.
    • (2014) JAMA Intern Med. , vol.174 , pp. 269-274
    • Patz Jr., E.F.1    Pinsky, P.2    Gatsonis, C.3
  • 38
    • 84870525789 scopus 로고    scopus 로고
    • Estimating overdiagnosis in low-dose computed tomography screening for lung cancer: A cohort study
    • Veronesi G, Maisonneuve P, Bellomi M, et al. Estimating overdiagnosis in low-dose computed tomography screening for lung cancer: a cohort study. Ann Intern Med. 2012;157:776-84.
    • (2012) Ann Intern Med. , vol.157 , pp. 776-784
    • Veronesi, G.1    Maisonneuve, P.2    Bellomi, M.3
  • 39
    • 84895793884 scopus 로고    scopus 로고
    • Benefits and harms of computed tomography lung cancer screening strategies: A comparative modeling study for the U.S. Preventive Services Task Force
    • de Koning HJ, Meza R, Plevritis SK, et al. Benefits and harms of computed tomography lung cancer screening strategies: a comparative modeling study for the U.S. Preventive Services Task Force. Ann Intern Med. 2014;160.
    • (2014) Ann Intern Med , pp. 160
    • de Koning, H.J.1    Meza, R.2    Plevritis, S.K.3
  • 40
    • 80355129626 scopus 로고    scopus 로고
    • Screening by chest radiograph and lung cancer mortality: The Prostate, Lung, Colorectal, and Ovarian (PLCO) randomized trial
    • Oken MM, Hocking WG, Kvale PA, et al. Screening by chest radiograph and lung cancer mortality: the Prostate, Lung, Colorectal, and Ovarian (PLCO) randomized trial. JAMA. 2011;306:1865-73.
    • (2011) JAMA. , vol.306 , pp. 1865-1873
    • Oken, M.M.1    Hocking, W.G.2    Kvale, P.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.