메뉴 건너뛰기




Volumn 40, Issue 7 PART A, 2014, Pages 10043-10051

Effect of preparation parameters on the properties of hydroxyapatite containing micro-arc oxidation coating on biodegradable ZK60 magnesium alloy

Author keywords

Biodegradable magnesium; Coating; Hydroxyapatite; Micro arc oxidation

Indexed keywords

CORROSION RESISTANCE; ELECTROLYTES; HYDROXYAPATITE; MAGNESIUM ALLOYS; OXIDATION;

EID: 84900512279     PISSN: 02728842     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ceramint.2014.02.104     Document Type: Article
Times cited : (94)

References (43)
  • 1
    • 28844481103 scopus 로고    scopus 로고
    • Magnesium and its alloys as orthopedic biomaterials: A review
    • M. Staiger, A. Pietak, J. Huadmai, and G. Dias Magnesium and its alloys as orthopedic biomaterials: a review Biomaterials 27 2006 1728 1734
    • (2006) Biomaterials , vol.27 , pp. 1728-1734
    • Staiger, M.1    Pietak, A.2    Huadmai, J.3    Dias, G.4
  • 2
    • 84897112323 scopus 로고    scopus 로고
    • Comparison of degradation behavior and the associated bone response of ZK60 and PLLA in vivo
    • 10.1002/jbm.a.34795
    • Z.R. Qi, Q. Zhang, L.L. Tan, X. Lin, Y. Yin, and X.L. Wang et al. Comparison of degradation behavior and the associated bone response of ZK60 and PLLA in vivo J. Biomed. Mater. Res. A 2013 10.1002/jbm.a.34795
    • (2013) J. Biomed. Mater. Res. A
    • Qi, Z.R.1    Zhang, Q.2    Tan, L.L.3    Lin, X.4    Yin, Y.5    Wang, X.L.6
  • 3
    • 84884674728 scopus 로고    scopus 로고
    • Biocompatibility of rapid-solidified magnesium alloy RS66 as a temporary biodegradable metal
    • E. Willbold, K. Kalla, I. Bartsch, K. Bobe, M. Brauneis, and S. Remennik et al. Biocompatibility of rapid-solidified magnesium alloy RS66 as a temporary biodegradable metal Acta Biomater. 9 2013 8509 8517
    • (2013) Acta Biomater. , vol.9 , pp. 8509-8517
    • Willbold, E.1    Kalla, K.2    Bartsch, I.3    Bobe, K.4    Brauneis, M.5    Remennik, S.6
  • 4
    • 78049423513 scopus 로고    scopus 로고
    • Bone-implant interface strength and osseointegration: Biodegradable magnesium alloy versus standard titanium control
    • C. Castellani, R.A. Lindtner, P. Hausbrandt, E. Tschegg, S.E. Stanzl-Tschegg, and G. Zanoni et al. Bone-implant interface strength and osseointegration: biodegradable magnesium alloy versus standard titanium control Acta Biomater. 7 2011 432 440
    • (2011) Acta Biomater. , vol.7 , pp. 432-440
    • Castellani, C.1    Lindtner, R.A.2    Hausbrandt, P.3    Tschegg, E.4    Stanzl-Tschegg, S.E.5    Zanoni, G.6
  • 5
    • 84856541796 scopus 로고    scopus 로고
    • Magnesium alloys for temporary implants in osteosynthesis: In vivo studies of their degradation and interaction with bone
    • T. Kraus, S.F. Fischerauer, A.C. Hänzi, P.J. Uggowitzer, J.F. Löffler, and A.M. Weinberg Magnesium alloys for temporary implants in osteosynthesis: in vivo studies of their degradation and interaction with bone Acta Biomater. 8 2012 1230 1238
    • (2012) Acta Biomater. , vol.8 , pp. 1230-1238
    • Kraus, T.1    Fischerauer, S.F.2    Hänzi, A.C.3    Uggowitzer, P.J.4    Löffler, J.F.5    Weinberg, A.M.6
  • 6
    • 84879868216 scopus 로고    scopus 로고
    • Biodegradable magnesium-based screw clinically equivalent to titanium screw in hallux valgus surgery: Short term results of the first prospective, randomized, controlled clinical pilot study
    • H. Windhagen, K. Radtke, A. Weizbauer, J. Diekmann, Y. Noll, and U. Kreimeyer et al. Biodegradable magnesium-based screw clinically equivalent to titanium screw in hallux valgus surgery: short term results of the first prospective, randomized, controlled clinical pilot study Biomed. Eng. Online 12 2013 62
    • (2013) Biomed. Eng. Online , vol.12 , pp. 62
    • Windhagen, H.1    Radtke, K.2    Weizbauer, A.3    Diekmann, J.4    Noll, Y.5    Kreimeyer, U.6
  • 7
    • 84884418367 scopus 로고    scopus 로고
    • Surface design of biodegradable magnesium alloys - A review
    • G. Wu, J.M. Ibrahim, and P.K. Chu Surface design of biodegradable magnesium alloys - a review Surf. Coat. Technol. 233 2013 2 12
    • (2013) Surf. Coat. Technol. , vol.233 , pp. 2-12
    • Wu, G.1    Ibrahim, J.M.2    Chu, P.K.3
  • 8
    • 84861644671 scopus 로고    scopus 로고
    • Biomedical coatings on magnesium alloys - A review
    • H. Hornberger, S. Virtanen, and A.R. Boccaccini Biomedical coatings on magnesium alloys - a review Acta Biomater. 8 2012 2442 2455
    • (2012) Acta Biomater. , vol.8 , pp. 2442-2455
    • Hornberger, H.1    Virtanen, S.2    Boccaccini, A.R.3
  • 9
    • 79952184599 scopus 로고    scopus 로고
    • Corrosion resistance and surface biocompatibility of a microarc oxidation coating on a Mg-Ca alloy
    • X.N. Gu, N. Li, W.R. Zhou, Y.F. Zheng, X. Zhao, and Q.Z. Cai et al. Corrosion resistance and surface biocompatibility of a microarc oxidation coating on a Mg-Ca alloy Acta Biomater. 7 2011 1880 1889
    • (2011) Acta Biomater. , Issue.7 , pp. 1880-1889
    • Gu, X.N.1    Li, N.2    Zhou, W.R.3    Zheng, Y.F.4    Zhao, X.5    Cai, Q.Z.6
  • 10
    • 84884671185 scopus 로고    scopus 로고
    • The in vitro degradation process and biocompatibility of a ZK60 magnesium alloy with a forsterite-containing micro-arc oxidation coating
    • X. Lin, L. Tan, Q. Zhang, K. Yang, Z. Hu, and J. Qiu et al. The in vitro degradation process and biocompatibility of a ZK60 magnesium alloy with a forsterite-containing micro-arc oxidation coating Acta Biomater. 9 2013 8631 8642
    • (2013) Acta Biomater. , vol.9 , pp. 8631-8642
    • Lin, X.1    Tan, L.2    Zhang, Q.3    Yang, K.4    Hu, Z.5    Qiu, J.6
  • 11
    • 84872071664 scopus 로고    scopus 로고
    • In vivo degradation performance of micro-arc-oxidized magnesium implants: A micro-CT study in rats
    • S.F. Fischerauer, T. Kraus, X. Wu, S. Tangl, E. Sorantin, and A.C. Hanzi et al. In vivo degradation performance of micro-arc-oxidized magnesium implants: a micro-CT study in rats Acta Biomater. 9 2013 5411 5420
    • (2013) Acta Biomater. , vol.9 , pp. 5411-5420
    • Fischerauer, S.F.1    Kraus, T.2    Wu, X.3    Tangl, S.4    Sorantin, E.5    Hanzi, A.C.6
  • 12
    • 84881165097 scopus 로고    scopus 로고
    • In vivo degradation and tissue compatibility of ZK60 magnesium alloy with micro-arc oxidation coating in a transcortical model
    • X. Lin, L. Tan, Q. Wang, G. Zhang, B. Zhang, and K. Yang In vivo degradation and tissue compatibility of ZK60 magnesium alloy with micro-arc oxidation coating in a transcortical model Mater. Sci. Eng. C 33 2013 3881 3888
    • (2013) Mater. Sci. Eng. C , vol.33 , pp. 3881-3888
    • Lin, X.1    Tan, L.2    Wang, Q.3    Zhang, G.4    Zhang, B.5    Yang, K.6
  • 13
    • 33847264072 scopus 로고    scopus 로고
    • Calcium orthophosphates
    • S.V. Dorozhkin Calcium orthophosphates J. Mater. Sci. 42 2007 1061 1095
    • (2007) J. Mater. Sci. , vol.42 , pp. 1061-1095
    • Dorozhkin, S.V.1
  • 14
    • 84855913099 scopus 로고    scopus 로고
    • Calcium phosphate coatings on magnesium alloys for biomedical applications: A review
    • S. Shadanbaz, and G.J. Dias Calcium phosphate coatings on magnesium alloys for biomedical applications: a review Acta Biomater. 8 2012 20 30
    • (2012) Acta Biomater. , vol.8 , pp. 20-30
    • Shadanbaz, S.1    Dias, G.J.2
  • 15
    • 68149149876 scopus 로고    scopus 로고
    • Calcium phosphate coatings for bio-implant applications: Materials, performance factors, and methodologies
    • S.R. Paital, and N.B. Dahotre Calcium phosphate coatings for bio-implant applications: materials, performance factors, and methodologies Mater. Sci. Eng. R: Reports 66 2009 1 70
    • (2009) Mater. Sci. Eng. R: Reports , vol.66 , pp. 1-70
    • Paital, S.R.1    Dahotre, N.B.2
  • 17
    • 77956648474 scopus 로고    scopus 로고
    • Clinical benefit of hydroxyapatite-coated pins compared with stainless steel pins in external fixation at the wrist: A randomised prospective study
    • O. Pieske, F. Kaltenhauser, L. Pichlmaier, N. Schramm, H. Trentzsch, and T. Loffler et al. Clinical benefit of hydroxyapatite-coated pins compared with stainless steel pins in external fixation at the wrist: a randomised prospective study Injury 41 2010 1031 1036
    • (2010) Injury , vol.41 , pp. 1031-1036
    • Pieske, O.1    Kaltenhauser, F.2    Pichlmaier, L.3    Schramm, N.4    Trentzsch, H.5    Loffler, T.6
  • 18
  • 19
    • 78649640345 scopus 로고    scopus 로고
    • Formation of bioceramic coatings containing hydroxyapatite on the titanium substrate by micro-arc oxidation coupled with electrophoretic deposition
    • Y. Bai, I.S. Park, H.H. Park, T.S. Bae, and M.H. Lee Formation of bioceramic coatings containing hydroxyapatite on the titanium substrate by micro-arc oxidation coupled with electrophoretic deposition J. Biomed. Mater. Res. Part B: Appl. Biomater. 95B 2010 365 373
    • (2010) J. Biomed. Mater. Res. Part B: Appl. Biomater. , vol.95 B , pp. 365-373
    • Bai, Y.1    Park, I.S.2    Park, H.H.3    Bae, T.S.4    Lee, M.H.5
  • 20
    • 84555203687 scopus 로고    scopus 로고
    • Development and characterization of MgO/hydroxyapatite composite coating on AZ31 magnesium alloy by plasma electrolytic oxidation coupled with electrophoretic deposition
    • D. Sreekanth, and N. Rameshbabu Development and characterization of MgO/hydroxyapatite composite coating on AZ31 magnesium alloy by plasma electrolytic oxidation coupled with electrophoretic deposition Mater. Lett. 68 2012 439 442
    • (2012) Mater. Lett. , vol.68 , pp. 439-442
    • Sreekanth, D.1    Rameshbabu, N.2
  • 21
    • 84883242379 scopus 로고    scopus 로고
    • Synthesis of biphasic calcium phosphate containing nanostructured films by micro arc oxidation on magnesium alloy
    • A. Seyfoori, S. Mirdamadi, Z.S. Seyedraoufi, A. Khavandi, and M. Aliofkhazraei Synthesis of biphasic calcium phosphate containing nanostructured films by micro arc oxidation on magnesium alloy Mater. Chem. Phys. 142 2013 87 94
    • (2013) Mater. Chem. Phys. , vol.142 , pp. 87-94
    • Seyfoori, A.1    Mirdamadi, S.2    Seyedraoufi, Z.S.3    Khavandi, A.4    Aliofkhazraei, M.5
  • 22
    • 77954861682 scopus 로고    scopus 로고
    • Growth characteristics and corrosion resistance of micro-arc oxidation coating on pure magnesium for biomedical applications
    • L. Zhao, C. Cui, Q. Wang, and S. Bu Growth characteristics and corrosion resistance of micro-arc oxidation coating on pure magnesium for biomedical applications Corros. Sci. 52 2010 2228 2234
    • (2010) Corros. Sci. , vol.52 , pp. 2228-2234
    • Zhao, L.1    Cui, C.2    Wang, Q.3    Bu, S.4
  • 23
    • 84866498757 scopus 로고    scopus 로고
    • Effect of TiO2 nanoparticles on the microstructure and corrosion behavior of MAO coatings on magnesium alloy
    • Y.L. Song, X.Y. Sun, and Y.H. Liu Effect of TiO2 nanoparticles on the microstructure and corrosion behavior of MAO coatings on magnesium alloy Mater. Corros. 63 2011 813 818
    • (2011) Mater. Corros. , vol.63 , pp. 813-818
    • Song, Y.L.1    Sun, X.Y.2    Liu, Y.H.3
  • 24
    • 63449088525 scopus 로고    scopus 로고
    • Adjustment of the ratio of Ca/P in the ceramic coating on Mg alloy by plasma electrolytic oxidation
    • Z. Yao, L. Li, and Z. Jiang Adjustment of the ratio of Ca/P in the ceramic coating on Mg alloy by plasma electrolytic oxidation Appl. Surf. Sci. 255 2009 6724 6728
    • (2009) Appl. Surf. Sci. , vol.255 , pp. 6724-6728
    • Yao, Z.1    Li, L.2    Jiang, Z.3
  • 25
    • 76649116515 scopus 로고    scopus 로고
    • A preliminary study of calcium containing plasma electrolytic oxidation coatings on AM50 magnesium alloy
    • P. Bala Srinivasan, J. Liang, C. Blawert, M. Störmer, and W. Dietzel A preliminary study of calcium containing plasma electrolytic oxidation coatings on AM50 magnesium alloy J. Mater. Sci. 45 2009 1406 1410
    • (2009) J. Mater. Sci. , vol.45 , pp. 1406-1410
    • Bala Srinivasan, P.1    Liang, J.2    Blawert, C.3    Störmer, M.4    Dietzel, W.5
  • 26
    • 77649239338 scopus 로고    scopus 로고
    • Characterization of calcium containing plasma electrolytic oxidation coatings on AM50 magnesium alloy
    • P.B. Srinivasan, J. Liang, C. Blawert, M. Störmer, and W. Dietzel Characterization of calcium containing plasma electrolytic oxidation coatings on AM50 magnesium alloy Appl. Surf. Sci. 256 2010 4017 4022
    • (2010) Appl. Surf. Sci. , vol.256 , pp. 4017-4022
    • Srinivasan, P.B.1    Liang, J.2    Blawert, C.3    Störmer, M.4    Dietzel, W.5
  • 27
    • 84872066609 scopus 로고    scopus 로고
    • Synthesis and properties of CaTiO3-containing coating on AZ31 magnesium alloy by micro-arc oxidation
    • H. Tang, and F. Wang Synthesis and properties of CaTiO3-containing coating on AZ31 magnesium alloy by micro-arc oxidation Mater. Lett. 93 2013 427 430
    • (2013) Mater. Lett. , vol.93 , pp. 427-430
    • Tang, H.1    Wang, F.2
  • 28
    • 84876712742 scopus 로고    scopus 로고
    • Effects of phosphates on microstructure and bioactivity of micro-arc oxidized calcium phosphate coatings on Mg-Zn-Zr magnesium alloy
    • Y.K. Pan, C.Z. Chen, D.G. Wang, and T.G. Zhao Effects of phosphates on microstructure and bioactivity of micro-arc oxidized calcium phosphate coatings on Mg-Zn-Zr magnesium alloy Colloids Surf. B: Biointerf. 109 2013 1 9
    • (2013) Colloids Surf. B: Biointerf. , vol.109 , pp. 1-9
    • Pan, Y.K.1    Chen, C.Z.2    Wang, D.G.3    Zhao, T.G.4
  • 29
    • 84881123005 scopus 로고    scopus 로고
    • Preparation and bioactivity of micro-arc oxidized calcium phosphate coatings
    • Y.K. Pan, C.Z. Chen, D.G. Wang, and Z.Q. Lin Preparation and bioactivity of micro-arc oxidized calcium phosphate coatings Mater. Chem. Phys. 141 2013 842 849
    • (2013) Mater. Chem. Phys. , vol.141 , pp. 842-849
    • Pan, Y.K.1    Chen, C.Z.2    Wang, D.G.3    Lin, Z.Q.4
  • 30
    • 84876284094 scopus 로고    scopus 로고
    • Bioactive Ca-P coating with self-sealing structure on pure magnesium
    • J. Gan, L. Tan, K. Yang, Z. Hu, Q. Zhang, and X. Fan et al. Bioactive Ca-P coating with self-sealing structure on pure magnesium J. Mater. Sci.: Mater. Med. 24 2013 889 901
    • (2013) J. Mater. Sci.: Mater. Med. , vol.24 , pp. 889-901
    • Gan, J.1    Tan, L.2    Yang, K.3    Hu, Z.4    Zhang, Q.5    Fan, X.6
  • 31
    • 84865959301 scopus 로고    scopus 로고
    • Potential bioactivity of coatings formed on AZ91D magnesium alloy by plasma electrolytic anodizing
    • T.-N. Vu, D. Veys-Renaux, and E. Rocca Potential bioactivity of coatings formed on AZ91D magnesium alloy by plasma electrolytic anodizing J. Biomed. Mater. Res. Part B: Appl. Biomater. 100B 2012 1846 1853
    • (2012) J. Biomed. Mater. Res. Part B: Appl. Biomater. , vol.100 B , pp. 1846-1853
    • Vu, T.-N.1    Veys-Renaux, D.2    Rocca, E.3
  • 32
    • 21244446139 scopus 로고    scopus 로고
    • Formation of oxygen bubbles and its influence on current efficiency in micro-arc oxidation process of AZ91D magnesium alloy
    • H. Guo, M. An, S. Xu, and H. Huo Formation of oxygen bubbles and its influence on current efficiency in micro-arc oxidation process of AZ91D magnesium alloy Thin Solid Films 485 2005 53 58
    • (2005) Thin Solid Films , vol.485 , pp. 53-58
    • Guo, H.1    An, M.2    Xu, S.3    Huo, H.4
  • 33
    • 0344639339 scopus 로고
    • 3∑- u state of oxygen and accurate franck-condon factors for the Schumann-Runge bands
    • 3∑- u state of oxygen and accurate franck-condon factors for the Schumann-Runge bands J. Mol. Spectrosc. 163 1994 9 18
    • (1994) J. Mol. Spectrosc. , vol.163 , pp. 9-18
    • Cheung, A.1    Mok, D.2    Sun, Y.3    Freeman, D.4
  • 34
    • 58049203993 scopus 로고    scopus 로고
    • Growth regularity of ceramic coating on magnesium alloy by plasma electrolytic oxidation
    • L. Chang Growth regularity of ceramic coating on magnesium alloy by plasma electrolytic oxidation J. Alloys Comp. 468 2009 462 465
    • (2009) J. Alloys Comp. , vol.468 , pp. 462-465
    • Chang, L.1
  • 37
    • 84863720580 scopus 로고    scopus 로고
    • Microstructure and biological properties of micro-arc oxidation coatings on ZK60 magnesium alloy
    • Y.K. Pan, C.Z. Chen, D.G. Wang, and X. Yu Microstructure and biological properties of micro-arc oxidation coatings on ZK60 magnesium alloy J. Biomed. Mater. Res. Part B: Appl. Biomater. 100B 2012 1574 1586
    • (2012) J. Biomed. Mater. Res. Part B: Appl. Biomater. , vol.100 B , pp. 1574-1586
    • Pan, Y.K.1    Chen, C.Z.2    Wang, D.G.3    Yu, X.4
  • 38
    • 84867746285 scopus 로고    scopus 로고
    • Biodegradation behavior of micro-arc oxidized AZ31 magnesium alloys formed in two different electrolytes
    • A. Seyfoori, S. Mirdamadi, A. Khavandi, and Z.S. Raufi Biodegradation behavior of micro-arc oxidized AZ31 magnesium alloys formed in two different electrolytes Appl. Surf. Sci. 261 2012 92 100
    • (2012) Appl. Surf. Sci. , vol.261 , pp. 92-100
    • Seyfoori, A.1    Mirdamadi, S.2    Khavandi, A.3    Raufi, Z.S.4
  • 39
    • 84862786795 scopus 로고    scopus 로고
    • Corrosion mechanism and model of pulsed DC microarc oxidation treated AZ31 alloy in simulated body fluid
    • Y. Gu, C.-f. Chen, S. Bandopadhyay, C. Ning, Y. Zhang, and Y. Guo Corrosion mechanism and model of pulsed DC microarc oxidation treated AZ31 alloy in simulated body fluid Appl. Surf. Sci. 258 2012 6116 6126
    • (2012) Appl. Surf. Sci. , vol.258 , pp. 6116-6126
    • Gu, Y.1    Chen, C.-F.2    Bandopadhyay, S.3    Ning, C.4    Zhang, Y.5    Guo, Y.6
  • 40
    • 84870238775 scopus 로고    scopus 로고
    • Fabrication and degradation behavior of micro-arc oxidized biomedical magnesium alloy wires
    • C.L. Chu, X. Han, J. Bai, F. Xue, and P.K. Chu Fabrication and degradation behavior of micro-arc oxidized biomedical magnesium alloy wires Surf. Coat. Technol. 213 2012 307 312
    • (2012) Surf. Coat. Technol. , vol.213 , pp. 307-312
    • Chu, C.L.1    Han, X.2    Bai, J.3    Xue, F.4    Chu, P.K.5
  • 41
    • 84868627197 scopus 로고    scopus 로고
    • Long-term corrosion inhibition mechanism of microarc oxidation coated AZ31 Mg alloys for biomedical applications
    • Y. Gu, S. Bandopadhyay, C.-f. Chen, C. Ning, and Y. Guo Long-term corrosion inhibition mechanism of microarc oxidation coated AZ31 Mg alloys for biomedical applications Mater. Des. 46 2013 66 75
    • (2013) Mater. Des. , vol.46 , pp. 66-75
    • Gu, Y.1    Bandopadhyay, S.2    Chen, C.-F.3    Ning, C.4    Guo, Y.5
  • 43
    • 69449084365 scopus 로고    scopus 로고
    • Comparison of electrochemical corrosion behaviour of MgO and ZrO2 coatings on AM50 magnesium alloy formed by plasma electrolytic oxidation
    • J. Liang, P.B. Srinivasan, C. Blawert, and W. Dietzel Comparison of electrochemical corrosion behaviour of MgO and ZrO2 coatings on AM50 magnesium alloy formed by plasma electrolytic oxidation Corros. Sci. 51 2009 2483 2492
    • (2009) Corros. Sci. , vol.51 , pp. 2483-2492
    • Liang, J.1    Srinivasan, P.B.2    Blawert, C.3    Dietzel, W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.