메뉴 건너뛰기




Volumn 36, Issue , 2014, Pages 98-108

Effect of dissolution/precipitation on the residual stress redistribution of plasma-sprayed hydroxyapatite coating on titanium substrate in simulated body fluid (SBF)

Author keywords

Calcium phosphate; Hydroxyapatite; Plasma spray coating; Raman spectroscopy; Residual stress; Simulated body Fluid

Indexed keywords

CALCIUM PHOSPHATE; COATINGS; HYDROXYAPATITE; RAMAN SPECTROSCOPY; RESIDUAL STRESSES; STRESS CONCENTRATION;

EID: 84899969683     PISSN: 17516161     EISSN: 18780180     Source Type: Journal    
DOI: 10.1016/j.jmbbm.2014.04.007     Document Type: Article
Times cited : (51)

References (32)
  • 1
    • 0029161727 scopus 로고
    • Onlay silicone and hydroxyapatite-tricalciumphosphate composite (HAP-TCP) blocks interfere with nasal bone growth in rabbits
    • Arakaki M., Yamashita S., Mutaf M., Naito S., Fujii T. Onlay silicone and hydroxyapatite-tricalciumphosphate composite (HAP-TCP) blocks interfere with nasal bone growth in rabbits. Cleft Palate Craniofac. J. 1995, 32(4):282-289.
    • (1995) Cleft Palate Craniofac. J. , vol.32 , Issue.4 , pp. 282-289
    • Arakaki, M.1    Yamashita, S.2    Mutaf, M.3    Naito, S.4    Fujii, T.5
  • 3
    • 0015160475 scopus 로고
    • Vibrational spectra of hydrothermally prepared hydroxyapatites
    • Blakeslee K.C., Condrate R.A. Vibrational spectra of hydrothermally prepared hydroxyapatites. J. Am. Ceram. Soc. 1971, 54:559-563.
    • (1971) J. Am. Ceram. Soc. , vol.54 , pp. 559-563
    • Blakeslee, K.C.1    Condrate, R.A.2
  • 4
    • 40549125271 scopus 로고
    • Determination of the piezospectroscopic coefficients for chromium-doped sapphire
    • Clarke D.R., He J. Determination of the piezospectroscopic coefficients for chromium-doped sapphire. J. Am. Ceram. Soc. 1995, 78(5):1347-1353.
    • (1995) J. Am. Ceram. Soc. , vol.78 , Issue.5 , pp. 1347-1353
    • Clarke, D.R.1    He, J.2
  • 6
    • 0033657714 scopus 로고    scopus 로고
    • 4V substrates during incubation in protein-free simulated body fluid
    • 4V substrates during incubation in protein-free simulated body fluid. J. Biomed. Mater. Res. 2000, 53:685-693.
    • (2000) J. Biomed. Mater. Res. , vol.53 , pp. 685-693
    • Grabmann, O.1    Heimann, R.B.2
  • 7
    • 0028417394 scopus 로고
    • In vitro testing of plasma-sprayed hydroxyapatite coatings
    • Gross K.A., Berndt C.C. In vitro testing of plasma-sprayed hydroxyapatite coatings. J. Mater. Sci. Mater. Med. 1994, 5:219-224.
    • (1994) J. Mater. Sci. Mater. Med. , vol.5 , pp. 219-224
    • Gross, K.A.1    Berndt, C.C.2
  • 8
    • 0028533742 scopus 로고
    • Effect of surface roughness of hydroxyapatite-coated titanium on the bone-implant interface shear strength
    • Hayashi K., Inadome T., Nakashima Y., Sugioka Y. Effect of surface roughness of hydroxyapatite-coated titanium on the bone-implant interface shear strength. Biomaterials 1995, 15(14):1187-1191.
    • (1995) Biomaterials , vol.15 , Issue.14 , pp. 1187-1191
    • Hayashi, K.1    Inadome, T.2    Nakashima, Y.3    Sugioka, Y.4
  • 9
    • 84899920895 scopus 로고    scopus 로고
    • ISO., 2007a 13779-2 Implant for Surgery-Hydroxyapatite- Part 2 Coatings of Hydroxyapatite.
    • ISO., 2007a 13779-2 Implant for Surgery-Hydroxyapatite- Part 2 Coatings of Hydroxyapatite.
  • 10
    • 84899901494 scopus 로고    scopus 로고
    • ISO., 2007b 13779-4 Implant for surgery-Hydroxyapatite- Part 4 Determination of coating adhesion strength.
    • ISO., 2007b 13779-4 Implant for surgery-Hydroxyapatite- Part 4 Determination of coating adhesion strength.
  • 11
    • 0028918271 scopus 로고
    • Comparison of bone-implant interface shear strength of hydroxyapatite-coated and alumina-coated metal implants
    • Inadome T., Hayashi K., Nakashima Y., Tsumura H., Sugioka Y. Comparison of bone-implant interface shear strength of hydroxyapatite-coated and alumina-coated metal implants. J. Biomed. Mater. Res. 1995, 29(1):19-24.
    • (1995) J. Biomed. Mater. Res. , vol.29 , Issue.1 , pp. 19-24
    • Inadome, T.1    Hayashi, K.2    Nakashima, Y.3    Tsumura, H.4    Sugioka, Y.5
  • 12
    • 0034316294 scopus 로고    scopus 로고
    • FT-Raman spectroscopy.a tool for monitoring the demineralization of bones
    • Kantoyannis C.G., Vagenas N.V. FT-Raman spectroscopy.a tool for monitoring the demineralization of bones. Appl. Spectrosc. 2000, 54:1605-1609.
    • (2000) Appl. Spectrosc. , vol.54 , pp. 1605-1609
    • Kantoyannis, C.G.1    Vagenas, N.V.2
  • 13
    • 33644766925 scopus 로고    scopus 로고
    • Bone compaction enhanced fixation of weight bearing hydroxyapatite-coated implants
    • Kold S., Rahbek O., Vestermark M., Overgaard S., Soballe K. Bone compaction enhanced fixation of weight bearing hydroxyapatite-coated implants. J. Artroplast. 2006, 21(2):263-270.
    • (2006) J. Artroplast. , vol.21 , Issue.2 , pp. 263-270
    • Kold, S.1    Rahbek, O.2    Vestermark, M.3    Overgaard, S.4    Soballe, K.5
  • 14
    • 84856077955 scopus 로고    scopus 로고
    • Acoustic emission and fatigue damage induced in plasma sprayed hydroxyapatite coating layer
    • Laonapakul T., Otsuka Y., Nimkerdphol R.A., Mutoh Y. Acoustic emission and fatigue damage induced in plasma sprayed hydroxyapatite coating layer. J. Mech. Behav. Biomed. Mater. 2012, 8:123-133.
    • (2012) J. Mech. Behav. Biomed. Mater. , vol.8 , pp. 123-133
    • Laonapakul, T.1    Otsuka, Y.2    Nimkerdphol, R.A.3    Mutoh, Y.4
  • 15
    • 84870220366 scopus 로고    scopus 로고
    • Failure behavior of plasma-sprayed HAp coating on commercially pure titanium substrate in simulatedbody fluid (SBF) under bending load
    • Laonapakul T., Nimkerdphol R.A., Otsuka Y., Mutoh Y. Failure behavior of plasma-sprayed HAp coating on commercially pure titanium substrate in simulatedbody fluid (SBF) under bending load. J. Mech. Behav. Biomed. Mater. 2012, 15(153-166):2012.
    • (2012) J. Mech. Behav. Biomed. Mater. , vol.15 , Issue.153-166 , pp. 2012
    • Laonapakul, T.1    Nimkerdphol, R.A.2    Otsuka, Y.3    Mutoh, Y.4
  • 17
    • 34047201755 scopus 로고    scopus 로고
    • Adhesive and bending failure of thermal sprayed hydroxyapatite coatings.effect of nanostructures at interface and crack propagation phenomenon during bending
    • Li H., Khor K.A., Cheang P. Adhesive and bending failure of thermal sprayed hydroxyapatite coatings.effect of nanostructures at interface and crack propagation phenomenon during bending. Eng. Fract. Mech. 2007, 74(12):1894-1903.
    • (2007) Eng. Fract. Mech. , vol.74 , Issue.12 , pp. 1894-1903
    • Li, H.1    Khor, K.A.2    Cheang, P.3
  • 18
    • 84899971165 scopus 로고
    • Proceedings of the Annual Meeting of the Japanese Society for Dental Materials and Devices Dental Materials Journal. 4 (special issue 5)
    • Miura, N., Akao, K., Aoki, S., 1985. Thermal expansion of calcium phosphate ceramics. In.Proceedings of the Annual Meeting of the Japanese Society for Dental Materials and Devices Dental Materials Journal. 4 (special issue 5), p. 137.
    • (1985) Thermal expansion of calcium phosphate ceramics , pp. 137
    • Miura, N.1    Akao, K.2    Aoki, S.3
  • 19
    • 0026028253 scopus 로고
    • Orthopaedic applications of hydroxyapatite
    • Oonishi H. Orthopaedic applications of hydroxyapatite. Biomaterials 1991, 12(2):171-178.
    • (1991) Biomaterials , vol.12 , Issue.2 , pp. 171-178
    • Oonishi, H.1
  • 20
    • 15244352982 scopus 로고    scopus 로고
    • Raman piezo-spectroscopic analysis of natural and synthetic biomaterials
    • Perzzotti G. Raman piezo-spectroscopic analysis of natural and synthetic biomaterials. Anal. Bioanal. Chem. 2004, 381:577-590.
    • (2004) Anal. Bioanal. Chem. , vol.381 , pp. 577-590
    • Perzzotti, G.1
  • 21
    • 0032527097 scopus 로고    scopus 로고
    • Vibrational spectroscopic study of tetracalcium phosphate in pure polycrystalline form and as a constituent of a self-setting bone cement
    • Posset U., Locklin E., Thull R., Kiefer W. Vibrational spectroscopic study of tetracalcium phosphate in pure polycrystalline form and as a constituent of a self-setting bone cement. J. Biomed. Mater. Res. 1998, 40:640-645.
    • (1998) J. Biomed. Mater. Res. , vol.40 , pp. 640-645
    • Posset, U.1    Locklin, E.2    Thull, R.3    Kiefer, W.4
  • 22
    • 67349136454 scopus 로고    scopus 로고
    • Characterization and fatigue damage of plasma sprayed HAp top coat with Ti and HAp/Ti bond coat layers on commercially pure titanium substrate
    • Rakngarm A., Mutoh Y. Characterization and fatigue damage of plasma sprayed HAp top coat with Ti and HAp/Ti bond coat layers on commercially pure titanium substrate. J. Mech. Behav. Biomed. Mater. 2009, 2(5):444-453.
    • (2009) J. Mech. Behav. Biomed. Mater. , vol.2 , Issue.5 , pp. 444-453
    • Rakngarm, A.1    Mutoh, Y.2
  • 23
    • 61349089754 scopus 로고    scopus 로고
    • Electrochemical depositions of calcium phosphate film on commercial pure titanium and Ti-6Al-4V in two types of electrolyte at room temperature
    • Rakngarm A., Mutoh Y. Electrochemical depositions of calcium phosphate film on commercial pure titanium and Ti-6Al-4V in two types of electrolyte at room temperature. J. Mater. Sci. Eng. C 2009, 29(1):275-283.
    • (2009) J. Mater. Sci. Eng. C , vol.29 , Issue.1 , pp. 275-283
    • Rakngarm, A.1    Mutoh, Y.2
  • 25
    • 78650723395 scopus 로고    scopus 로고
    • Compositionally graded hydroxyapatite tricalcium phosphate coating on Ti by laser and induction plasma
    • Roy M., Balla V.K., Bandyopadhyay A., Bose S. Compositionally graded hydroxyapatite tricalcium phosphate coating on Ti by laser and induction plasma. Acta Biomater. 2011, 7:866-873.
    • (2011) Acta Biomater. , vol.7 , pp. 866-873
    • Roy, M.1    Balla, V.K.2    Bandyopadhyay, A.3    Bose, S.4
  • 26
    • 78650183423 scopus 로고    scopus 로고
    • Induction plasma sprayed nano hydroxyapatite coatings on titanium for orthopaedic and dental implants
    • Roy M., Bandyopadhyay A., Bose S. Induction plasma sprayed nano hydroxyapatite coatings on titanium for orthopaedic and dental implants. Surf. Coat. Technol. 2011, 205(8-9):2785-2792.
    • (2011) Surf. Coat. Technol. , vol.205 , Issue.8-9 , pp. 2785-2792
    • Roy, M.1    Bandyopadhyay, A.2    Bose, S.3
  • 27
    • 0031104959 scopus 로고    scopus 로고
    • Mechanical and chemical consequences of the residual stresses in plasma sprayed hydroxyapatite coatings
    • Sergo V., Sbaizero O., Clake D.R. Mechanical and chemical consequences of the residual stresses in plasma sprayed hydroxyapatite coatings. Biomaterials 1997, 18:477-482.
    • (1997) Biomaterials , vol.18 , pp. 477-482
    • Sergo, V.1    Sbaizero, O.2    Clake, D.R.3
  • 28
    • 0036151636 scopus 로고    scopus 로고
    • The effect of structural characteristics on the in vitro bioactivity of hydroxyapatite
    • Shi D., Jiang G., Bauer J. The effect of structural characteristics on the in vitro bioactivity of hydroxyapatite. J. Biomed. Mat. Res. B.Appl. Biomater. 2002, 63:71-78.
    • (2002) J. Biomed. Mat. Res. B.Appl. Biomater. , vol.63 , pp. 71-78
    • Shi, D.1    Jiang, G.2    Bauer, J.3
  • 31
    • 71949113287 scopus 로고    scopus 로고
    • Effect of varying HAP/TCP ratios in tape-cast biphasic calcium phosphate ceramics on response in vitro
    • Tanimoto Y., Shibata Y., Murakami A., Miyazaki T., Nishiyama N. Effect of varying HAP/TCP ratios in tape-cast biphasic calcium phosphate ceramics on response in vitro. J. Hard Tissue Biol. 2009, 18(2):71-76.
    • (2009) J. Hard Tissue Biol. , vol.18 , Issue.2 , pp. 71-76
    • Tanimoto, Y.1    Shibata, Y.2    Murakami, A.3    Miyazaki, T.4    Nishiyama, N.5
  • 32
    • 8144226636 scopus 로고    scopus 로고
    • Measurement of residual stresses in plasma-sprayed hydroxyapatite coatings on titanium alloy
    • Yang Y.C., Chang E. Measurement of residual stresses in plasma-sprayed hydroxyapatite coatings on titanium alloy. Surf. Coat. Technol. 2005, 190:122-131.
    • (2005) Surf. Coat. Technol. , vol.190 , pp. 122-131
    • Yang, Y.C.1    Chang, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.