메뉴 건너뛰기




Volumn 9, Issue 4, 2014, Pages

Advanced beamformers for cochlear implant users: Acute measurement of speech perception in challenging listening conditions

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ALGORITHM; ARTICLE; BINAURAL BEAMFORMING TECHNOLOGY; BIOTECHNOLOGY; CLINICAL ARTICLE; COCHLEA PROSTHESIS; CONTROLLED STUDY; EQUIPMENT DESIGN; EXPERIMENTAL STUDY; GERMANY; HEARING AID; HUMAN; MIDDLE AGED; MONAURAL BEAMFORMING TECHNOLOGY; NOISE REDUCTION; RANDOMIZED CONTROLLED TRIAL; SCORING SYSTEM; SIGNAL DETECTION; SIGNAL NOISE RATIO; SPEECH ANALYSIS; SPEECH PERCEPTION; ANALYSIS OF VARIANCE; AUDITORY THRESHOLD; ENVIRONMENT;

EID: 84899683043     PISSN: None     EISSN: 19326203     Source Type: Journal    
DOI: 10.1371/journal.pone.0095542     Document Type: Article
Times cited : (63)

References (36)
  • 1
  • 2
    • 33750625609 scopus 로고    scopus 로고
    • Simultaneous bilateral cochlear implantation in adults: A multicenter clinical study
    • DOI 10.1097/01.aud.0000246816.50820.42, PII 0000344620061200000010
    • Litovsky R, Parkinson A, Arcaroli J, Sammeth C (2006) Simultaneous bilateral cochlear implantation in adults: a multicenter clinical study. Ear Hear. 27(6):714-31. (Pubitemid 44691232)
    • (2006) Ear and Hearing , vol.27 , Issue.6 , pp. 714-731
    • Litovsky, R.1    Parkinson, A.2    Arcaroli, J.3    Sammeth, C.4
  • 3
    • 33845588915 scopus 로고    scopus 로고
    • The development of the Nucleus Freedom cochlear implant system
    • DOI 10.1177/1084713806296386
    • Patrick JF, Busby PA, Gibson PJ (2006) The development of the Nucleus Freedom Cochlear implant system. Trends Amplif. 10(4):175-200. (Pubitemid 44934659)
    • (2006) Trends in Amplification , vol.10 , Issue.4 , pp. 175-200
    • Patrick, J.F.1    Busby, P.A.2    Gibson, P.J.3
  • 4
    • 2342664953 scopus 로고    scopus 로고
    • Performance of Subjects Fit with the Advanced Bionics CII and Nucleus 3G Cochlear Implant Devices
    • DOI 10.1001/archotol.130.5.624
    • Spahr A, Dorman M (2004). Performance of subjects fit with the Advanced Bionics CII and Nucleus 3G cochlear implant devices. Arch Otolaryngol Head Neck Surg. 130(5):624-8. (Pubitemid 38609675)
    • (2004) Archives of Otolaryngology - Head and Neck Surgery , vol.130 , Issue.5 , pp. 624-628
    • Spahr, A.J.1    Dorman, M.F.2
  • 5
    • 0036186851 scopus 로고    scopus 로고
    • Adaptive dynamic range optimization for cochlear implants: A preliminary study
    • James CJ, Blamey PJ, Martin L, Swanson B, Just Y, et al. (2002) Adaptive dynamic range optimization for cochlear implants: a preliminary study. Ear Hear. 23(1 Suppl):49S-58S. (Pubitemid 34195174)
    • (2002) Ear and Hearing , vol.23 , Issue.1 SUPPL.
    • James, C.J.1    Blamey, P.J.2    Martin, L.3    Swanson, B.4    Just, Y.5    Macfarlane, D.6
  • 6
    • 78649497796 scopus 로고    scopus 로고
    • Results of a pilot study with a signal enhancement algorithm for HiRes120 cochlear implant users
    • Buechner A, Brendel M, Saalfeld H, Litvak L, Frohne-Buechner C, et al. (2010) Results of a pilot study with a signal enhancement algorithm for HiRes120 cochlear implant users. Otol Neurotol. 31(9):1386-90.
    • (2010) Otol Neurotol , vol.31 , Issue.9 , pp. 1386-1390
    • Buechner, A.1    Brendel, M.2    Saalfeld, H.3    Litvak, L.4    Frohne-Buechner, C.5
  • 7
    • 84862903529 scopus 로고    scopus 로고
    • Combining directional microphone and single-channel noise reduction algorithms: A clinical evaluation in difficult listening conditions with cochlear implant users
    • Hersbach AA, Arora K, Mauger SJ, Dawson PW (2012) Combining directional microphone and single-channel noise reduction algorithms: a clinical evaluation in difficult listening conditions with cochlear implant users. Ear Hear. 33(4):e13-23.
    • (2012) Ear Hear , vol.33 , Issue.4
    • Hersbach, A.A.1    Arora, K.2    Mauger, S.J.3    Dawson, P.W.4
  • 8
    • 33846054388 scopus 로고    scopus 로고
    • Speech understanding in background noise with the two-microphone adaptive beamformer BEAM in the nucleus Freedom cochlear implant system
    • DOI 10.1097/01.aud.0000252470.54246.54, PII 0000344620070200000006
    • Spriet A, Van Deun L, Eftaxiadis K, Laneau J, Moonen M, et al. (2007) Speech understanding in background noise with the two-microphone adaptive beamformer BEAM in the Nucleus Freedom Cochlear Implant System. Ear Hear. 28(1):62-72. (Pubitemid 46066844)
    • (2007) Ear and Hearing , vol.28 , Issue.1 , pp. 62-72
    • Spriet, A.1    Van Deun, L.2    Eftaxiadis, K.3    Laneau, J.4    Moonen, M.5    Van Dijk, B.6    Van Wieringen, A.7    Wouters, J.8
  • 9
    • 84861306126 scopus 로고    scopus 로고
    • Benefit of a commercially available cochlear implant processor with dual-microphone beamforming: A multi-center study
    • Wolfe J, Parkinson A, Schafer EC, Gilden J, Rehwinkel K, et al. (2012) Benefit of a commercially available cochlear implant processor with dual-microphone beamforming: a multi-center study. Otol Neurotol. 33(4):553-60.
    • (2012) Otol Neurotol , vol.33 , Issue.4 , pp. 553-560
    • Wolfe, J.1    Parkinson, A.2    Schafer, E.C.3    Gilden, J.4    Rehwinkel, K.5
  • 10
    • 0026716353 scopus 로고
    • Evaluation of an adaptive beamforming method for hearing aids
    • Greenberg JE, Zurek PM (1992) Evaluation of an adaptive beamforming method for hearing aids. J Acoust Soc Am. 91(3):1662-76.
    • (1992) J Acoust Soc Am , vol.91 , Issue.3 , pp. 1662-1676
    • Greenberg, J.E.1    Zurek, P.M.2
  • 11
    • 0027525454 scopus 로고
    • Superdirective arrays for hearing aids
    • Kates JM (1993) Superdirective arrays for hearing aids. J Acoust Soc Am. 94(4):1930-3.
    • (1993) J Acoust Soc Am , vol.94 , Issue.4 , pp. 1930-1933
    • Kates, J.M.1
  • 12
    • 0035106985 scopus 로고    scopus 로고
    • Performance of an adaptive beamforming noise reduction scheme for hearing aid applications. II. Experimental verification of the predictions
    • DOI 10.1121/1.1338558
    • Kompis M, Dillier N (2001) Performance of an adaptive beamforming noise reduction scheme for hearing aid applications. II. Experimental verification of the predictions. J Acoust Soc Am. 109(3):1134-43. (Pubitemid 32215919)
    • (2001) Journal of the Acoustical Society of America , vol.109 , Issue.3 , pp. 1134-1143
    • Kompis, M.1    Dillier, N.2
  • 14
  • 15
    • 0036517293 scopus 로고    scopus 로고
    • Evaluation of an adaptive, directional-microphone hearing aid
    • Ricketts T, Henry P (2002) Evaluation of an adaptive, directional-microphone hearing aid. Int J Audiol. 41(2):100-12. (Pubitemid 37390983)
    • (2002) International Journal of Audiology , vol.41 , Issue.2 , pp. 100-112
    • Ricketts, T.A.1    Henry, P.2
  • 16
    • 0033107706 scopus 로고    scopus 로고
    • Comparison of performance across three directional hearing aids
    • Ricketts T, Dhar S (1999) Comparison of performance across three directional hearing aids. J Am Acad Audiol. 10(4):180-9.
    • (1999) J Am Acad Audiol , vol.10 , Issue.4 , pp. 180-189
    • Ricketts, T.1    Dhar, S.2
  • 17
    • 0033249956 scopus 로고    scopus 로고
    • Making sense of directional microphone hearing aids
    • Ricketts T, Mueller HG (1999) Making sense of directional microphone hearing aids. Am J Audiol. 8(2):117-27.
    • (1999) Am J Audiol , vol.8 , Issue.2 , pp. 117-127
    • Ricketts, T.1    Mueller, H.G.2
  • 18
    • 33144485519 scopus 로고    scopus 로고
    • Effectiveness of directional microphones and noise reduction schemes in hearing aids: A systematic review of the evidence
    • Bentler RA (2005) Effectiveness of directional microphones and noise reduction schemes in hearing aids: a systematic review of the evidence. J Am Acad Audiol. 16(7):473-84.
    • (2005) J Am Acad Audiol , vol.16 , Issue.7 , pp. 473-484
    • Bentler, R.A.1
  • 19
    • 84871516141 scopus 로고    scopus 로고
    • An Evidence-Based Systematic Review of Directional Microphones and Digital Noise Reduction Hearing Aids in School-Age Children with Hearing Loss
    • McCreery RW, Venediktov RA, Coleman JJ, Leech HM (2012) An Evidence-Based Systematic Review of Directional Microphones and Digital Noise Reduction Hearing Aids in School-Age Children with Hearing Loss. Am J Audiol. 21(2):295-312.
    • (2012) Am J Audiol , vol.21 , Issue.2 , pp. 295-312
    • McCreery, R.W.1    Venediktov, R.A.2    Coleman, J.J.3    Leech, H.M.4
  • 20
    • 33748631838 scopus 로고    scopus 로고
    • Speech recognition and comfort using hearing instruments with adaptive directional characteristics in asymmetric listening conditions
    • DOI 10.1097/01.aud.0000188185.78217.c5, PII 0000344620051200000012
    • Mackenzie E, Lutman ME (2005) Speech recognition and comfort using hearing instruments with adaptive directional characteristics in asymmetric listening conditions. Ear Hear. 26(6):669-79. (Pubitemid 44378681)
    • (2005) Ear and Hearing , vol.26 , Issue.6 , pp. 669-679
    • Mackenzie, E.1    Lutman, M.E.2
  • 21
    • 84867357313 scopus 로고    scopus 로고
    • Single and Multiple Microphone Noise Reduction Strategies in Cochlear Implants
    • Kokkinakis K, Azimi B, Hu Y, Friedland DR (2012) Single and Multiple Microphone Noise Reduction Strategies in Cochlear Implants. Trends Amplif. 16(2):102-16.
    • (2012) Trends Amplif , vol.16 , Issue.2 , pp. 102-116
    • Kokkinakis, K.1    Azimi, B.2    Hu, Y.3    Friedland, D.R.4
  • 23
    • 0030730696 scopus 로고    scopus 로고
    • Evaluation of noise reduction systems for cochlear implant users in different acoustic environment
    • Hamacher V, Doering WH, Mauer G, Fleischmann H, Hennecke J (1997) Evaluation of noise reduction systems for cochlear implant users in different acoustic environment. Am J Otol. 18(6 Suppl):S46-9. (Pubitemid 27512617)
    • (1997) American Journal of Otology , vol.18 , Issue.6 SUPPL.
    • Hamacher, V.1    Doering, W.H.2    Mauer, G.3    Fleischmann, H.4    Hennecke, J.5
  • 24
    • 0028913161 scopus 로고
    • Evaluation of a portable two-microphone adaptive beamforming speech processor with cochlear implant patients
    • van Hoesel RJ, Clark GM (1995) Evaluation of a portable two-microphone adaptive beamforming speech processor with cochlear implant patients. J Acoust Soc Am. 97(4):2498-503.
    • (1995) J Acoust Soc Am , vol.97 , Issue.4 , pp. 2498-2503
    • Van Hoesel, R.J.1    Clark, G.M.2
  • 28
    • 0030829791 scopus 로고    scopus 로고
    • Development and evaluation of a German sentence test for objective and subjective speech intelligibility assessment
    • DOI 10.1121/1.419624
    • Kollmeier B, Wesselkamp M (1997) Development and evaluation of a German sentence test for objective and subjective speech intelligibility assessment. J Acoust Soc Am. 1997; 102(4):2412-21. (Pubitemid 27441394)
    • (1997) Journal of the Acoustical Society of America , vol.102 , Issue.4 , pp. 2412-2421
    • Kollmeier, B.1    Wesselkamp, M.2
  • 29
    • 18844449425 scopus 로고    scopus 로고
    • Sentence intelligibility in noise for listeners with normal hearing and hearing impairment: Influence of measurement procedure and masking parameters
    • DOI 10.1080/14992020500057517
    • Wagener KC, Brand T (2005) Sentence intelligibility in noise for listeners with normal hearing and hearing impairment: influence of measurement procedure and masking parameters. Int J Audiol. 44(3):144-56. (Pubitemid 40694910)
    • (2005) International Journal of Audiology , vol.44 , Issue.3 , pp. 144-156
    • Wagener, K.C.1    Brand, T.2
  • 30
    • 84880470417 scopus 로고    scopus 로고
    • Unilateral and bilateral hearing aids, spatial release from masking and auditory acclimatization
    • doi: 10.1121/1.4807783
    • Dawes P, Munro KJ, Kalluri S, Edwards B (2013) Unilateral and bilateral hearing aids, spatial release from masking and auditory acclimatization. J Acoust Soc Am. 134(1):596-606. doi: 10.1121/1.4807783.
    • (2013) J Acoust Soc Am , vol.134 , Issue.1 , pp. 596-606
    • Dawes, P.1    Munro, K.J.2    Kalluri, S.3    Edwards, B.4
  • 31
    • 33749543456 scopus 로고    scopus 로고
    • Effects of directional microphone and adaptive multichannel noise reduction algorithm on cochlear implant performance
    • DOI 10.1121/1.2258500
    • Chung K, Zeng FG, Acker KN (2006) Effects of directional microphone and adaptive multichannel noise reduction algorithm on cochlear implant performance. J Acoust Soc Am. 120: 2216-27. (Pubitemid 44536146)
    • (2006) Journal of the Acoustical Society of America , vol.120 , Issue.4 , pp. 2216-2227
    • Chung, K.1    Zeng, F.-G.2    Acker, K.N.3
  • 32
    • 0034788357 scopus 로고    scopus 로고
    • Speech recognition in noise for cochlear implantees with a two-microphone monaural adaptive noise reduction system
    • Wouters J, Van den Berghe J (2001) Speech recognition in noise for cochlear implantees with a two microphone monaural adaptive noise reduction system. Ear Hear. 22: 420-30. (Pubitemid 32963331)
    • (2001) Ear and Hearing , vol.22 , Issue.5 , pp. 420-430
    • Wouters, J.1    Vanden, B.J.2
  • 33
    • 79953872762 scopus 로고    scopus 로고
    • Evaluation of different signal processing options in unilateral and bilateral cochlear freedom implant recipients using R-Space background noise
    • Brockmeyer AM, Potts LG (2011) Evaluation of different signal processing options in unilateral and bilateral cochlear freedom implant recipients using R-Space background noise. J Am Acad Audiol. 22(2):65-80.
    • (2011) J Am Acad Audiol , vol.22 , Issue.2 , pp. 65-80
    • Brockmeyer, A.M.1    Potts, L.G.2
  • 34
    • 77956580988 scopus 로고    scopus 로고
    • Speech perception for adult cochlear implant recipients in a realistic background noise: Effectiveness of preprocessing strategies and external options for improving speech recognition in noise
    • Gifford RH, Revit LJ (2010) Speech perception for adult cochlear implant recipients in a realistic background noise: effectiveness of preprocessing strategies and external options for improving speech recognition in noise. J Am Acad Audiol. 21(7):441-51.
    • (2010) J Am Acad Audiol , vol.21 , Issue.7 , pp. 441-451
    • Gifford, R.H.1    Revit, L.J.2
  • 35
    • 0034000808 scopus 로고    scopus 로고
    • Directivity quantification in hearing aids: Fitting and measurement effects
    • Ricketts T (2000) Directivity quantification in hearing aids: fitting and measurement effects. Ear Hear. 21(1):45-58.
    • (2000) Ear Hear , vol.21 , Issue.1 , pp. 45-58
    • Ricketts, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.