메뉴 건너뛰기




Volumn 6, Issue 5, 2010, Pages 643-652

Multimodality imaging in transcatheter aortic valve implantation: Key steps to assess procedural feasibility

Author keywords

Aortic stenosis; Multi detector row computed tomography; Transcatheter aortic valve implantation

Indexed keywords

ACCURACY; ANGIOGRAPHY; AORTA PROSTHESIS; AORTA ROOT; AORTA STENOSIS; AORTA VALVE; AORTA VALVE REPLACEMENT; ARTERY; CORONARY ARTERY; DISEASE SEVERITY; FEASIBILITY STUDY; HEART LEFT VENTRICLE; HUMAN; IMAGING SYSTEM; MITRAL VALVE REGURGITATION; MORPHOLOGY; MULTIDETECTOR COMPUTED TOMOGRAPHY; NUCLEAR MAGNETIC RESONANCE IMAGING; PATHOLOGICAL ANATOMY; PREOPERATIVE EVALUATION; REVIEW; THREE DIMENSIONAL ECHOCARDIOGRAPHY; TRANSCATHETER AORTIC VALVE IMPLANTATION; TREATMENT CONTRAINDICATION; TWO DIMENSIONAL ECHOCARDIOGRAPHY; VASCULAR ACCESS; COMPUTER ASSISTED TOMOGRAPHY; CORONARY BLOOD VESSEL; HEART LEFT VENTRICLE FUNCTION; HEART VALVE REPLACEMENT; HISTOLOGY; METHODOLOGY; PATHOLOGY; PATHOPHYSIOLOGY;

EID: 79952278899     PISSN: 1774024X     EISSN: 19696213     Source Type: Journal    
DOI: 10.4244/EIJV6I5A107     Document Type: Review
Times cited : (46)

References (37)
  • 1
    • 65149095001 scopus 로고    scopus 로고
    • Outcomes and safety of percutaneous aortic valve replacement
    • Zajarias A, Cribier AG. Outcomes and safety of percutaneous aortic valve replacement. J Am Coll Cardiol 2009;53:1829-1836.
    • (2009) J Am Coll Cardiol , vol.53 , pp. 1829-1836
    • Zajarias, A.1    Cribier, A.G.2
  • 4
    • 55849132881 scopus 로고    scopus 로고
    • Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) corevalve revalving system: Results from the multicentre, expanded evaluation registry 1-year following CE mark approval
    • Piazza N, Grube E, Gerckens U, den HP, Linke A, Luha O, Ramondo A, Ussia G, Wenaweser P, Windecker S, Laborde JC, De JP, Serruys PW. Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) corevalve revalving system: results from the multicentre, expanded evaluation registry 1-year following CE mark approval. EuroIntervention 2008;4:242-249.
    • (2008) EuroIntervention , vol.4 , pp. 242-249
    • Piazza, N.1    Grube, E.2    Gerckens, U.3    Den, H.P.4    Linke, A.5    Luha, O.6    Ramondo, A.7    Ussia, G.8    Wenaweser, P.9    Windecker, S.10    Laborde, J.C.11    De, J.P.12    Serruys, P.W.13
  • 11
    • 77950051087 scopus 로고    scopus 로고
    • Aortic annulus and ascending aorta: Comparison of preoperative and periooperative measurement in patients with aortic stenosis
    • Smid M, Ferda J, Baxa J, Cech J, Hajek T, Kreuzberg B, Rokyta R. Aortic annulus and ascending aorta: Comparison of preoperative and periooperative measurement in patients with aortic stenosis. Eur J Radiol 2010;74:152-5.
    • (2010) Eur J Radiol , vol.74 , pp. 152-155
    • Smid, M.1    Ferda, J.2    Baxa, J.3    Cech, J.4    Hajek, T.5    Kreuzberg, B.6    Rokyta, R.7
  • 13
    • 70449658300 scopus 로고    scopus 로고
    • The value of true-FISP sequence added to conventional gadolinium-enhanced MRA of abdominal aorta and its major branches
    • Iozzelli A, D'Orta G, Aliprandi A, Secchi F, Di LG, Sardanelli F. The value of true-FISP sequence added to conventional gadolinium-enhanced MRA of abdominal aorta and its major branches. Eur J Radiol 2009;72:489-93.
    • (2009) Eur J Radiol , vol.72 , pp. 489-493
    • Iozzelli, A.1    D'Orta, G.2    Aliprandi, A.3    Secchi, F.4    Di, L.G.5    Sardanelli, F.6
  • 18
    • 37349104948 scopus 로고    scopus 로고
    • Planimetric and continuity equation assessment of aortic valve area: Head to head comparison between cardiac magnetic resonance and echocardiography
    • DOI 10.1002/jmri.21182
    • Pouleur AC, le Polain de Waroux JB, Pasquet A, Vancraeynest D, Vanoverschelde JL, Gerber BL. Planimetric and continuity equation assessment of aortic valve area: Head to head comparison between cardiac magnetic resonance and echocardiography. J Magn Reson Imaging 2007;26:1436-1443. (Pubitemid 350291270)
    • (2007) Journal of Magnetic Resonance Imaging , vol.26 , Issue.6 , pp. 1436-1443
    • Pouleur, A.-C.1    De Waroux, J.-B.L.P.2    Pasquet, A.3    Vancraeynest, D.4    Vanoverschelde, J.-L.J.5    Gerber, B.L.6
  • 20
    • 76649123667 scopus 로고    scopus 로고
    • Correlation of Device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self-expanding CoreValve prosthesis
    • John D, Buellesfeld L, Yuecel S, Mueller R, Latsios G, Beucher H, Gerckens U, Grube E. Correlation of Device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self-expanding CoreValve prosthesis. JACC Cardiovasc Interv 2010;3:233-243.
    • (2010) JACC Cardiovasc Interv , vol.3 , pp. 233-243
    • John, D.1    Buellesfeld, L.2    Yuecel, S.3    Mueller, R.4    Latsios, G.5    Beucher, H.6    Gerckens, U.7    Grube, E.8
  • 24
    • 69949174862 scopus 로고    scopus 로고
    • Three-dimensional imaging of the aortic valve and aortic root with computed tomography: New standards in an era of transcatheter valve repair/implantation
    • Schoenhagen P, Tuzcu EM, Kapadia SR, Desai MY, Svensson LG. Three-dimensional imaging of the aortic valve and aortic root with computed tomography: new standards in an era of transcatheter valve repair/implantation. Eur Heart J 2009;30:2079-2086.
    • (2009) Eur Heart J , vol.30 , pp. 2079-2086
    • Schoenhagen, P.1    Tuzcu, E.M.2    Kapadia, S.R.3    Desai, M.Y.4    Svensson, L.G.5
  • 28
  • 29
    • 70350437284 scopus 로고    scopus 로고
    • Aortic root measurement by cardiovascular magnetic resonance: Specification of planes and lines of measurement, and corresponding normal values
    • Burman E, Keegan J, Kilner P. Aortic root measurement by cardiovascular magnetic resonance: specification of planes and lines of measurement, and corresponding normal values. Circ Cardiovasc Imaging 2008;1:104-113.
    • (2008) Circ Cardiovasc Imaging , vol.1 , pp. 104-113
    • Burman, E.1    Keegan, J.2    Kilner, P.3
  • 30
    • 74049098326 scopus 로고    scopus 로고
    • Pre-procedural imaging of aortic root orientation and dimensions: Comparison between X-ray angiographic planar imaging and 3-dimensional multidetector row computed tomography
    • Kurra V, Kapadia SR, Tuzcu EM, Halliburton SS, Svensson L, Roselli EE, Schoenhagen P. Pre-procedural imaging of aortic root orientation and dimensions: comparison between X-ray angiographic planar imaging and 3-dimensional multidetector row computed tomography. JACC Cardiovasc Interv 2010;3:105-113.
    • (2010) JACC Cardiovasc Interv , vol.3 , pp. 105-113
    • Kurra, V.1    Kapadia, S.R.2    Tuzcu, E.M.3    Halliburton, S.S.4    Svensson, L.5    Roselli, E.E.6    Schoenhagen, P.7
  • 31
    • 58649088446 scopus 로고    scopus 로고
    • Echocardiography for transcatheter aortic valve implantation
    • Chin D. Echocardiography for transcatheter aortic valve implantation. Eur J Echocardiogr 2009;10:i21-i29.
    • (2009) Eur J Echocardiogr , vol.10
    • Chin, D.1
  • 33
    • 77950503224 scopus 로고    scopus 로고
    • Aorto-iliac angiography as a screening tool in selecting patients for transfemoral aortic valve implantation with the Edwards SAPIEN bioprosthesis
    • Eltchaninoff H, Kerkeni M, Zajarias A, Tron C, Godin M, Sanchez GC, Baala B, Cribier A. Aorto-iliac angiography as a screening tool in selecting patients for transfemoral aortic valve implantation with the Edwards SAPIEN bioprosthesis. EuroIntervention 2009;5:438-442.
    • (2009) EuroIntervention , vol.5 , pp. 438-442
    • Eltchaninoff, H.1    Kerkeni, M.2    Zajarias, A.3    Tron, C.4    Godin, M.5    Sanchez, G.C.6    Baala, B.7    Cribier, A.8
  • 35
    • 31344456264 scopus 로고    scopus 로고
    • Meta-analysis of comparative diagnostic performance of magnetic resonance imaging and multislice computed tomography for noninvasive coronary angiography
    • DOI 10.1016/j.ahj.2005.03.022, PII S0002870305003170
    • Schuijf JD, Bax JJ, Shaw LJ, de RA, Lamb HJ, van der Wall EE, Wijns W. Meta-analysis of comparative diagnostic performance of magnetic resonance imaging and multislice computed tomography for noninvasive coronary angiography. Am Heart J 2006;151:404-411. (Pubitemid 43144743)
    • (2006) American Heart Journal , vol.151 , Issue.2 , pp. 404-411
    • Schuijf, J.D.1    Bax, J.J.2    Shaw, L.J.3    De Roos, A.4    Lamb, H.J.5    Van Der, W.E.E.6    Wijns, W.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.