메뉴 건너뛰기




Volumn 9, Issue 4, 2014, Pages

Effect of passive leg raising on systemic hemodynamics of pregnant women: A dynamic assessment of maternal cardiovascular function at 22-24 weeks of gestation

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; BLOOD PRESSURE MEASUREMENT; CARDIOVASCULAR FUNCTION; CASE CONTROL STUDY; CONTROLLED STUDY; CROSS-SECTIONAL STUDY; FEMALE; GESTATIONAL AGE; HEART FUNCTION; HEART OUTPUT; HEART STROKE VOLUME; HEMODYNAMICS; HUMAN; IMPEDANCE CARDIOGRAPHY; MAJOR CLINICAL STUDY; NON INVASIVE PROCEDURE; PREGNANT WOMAN; PROSPECTIVE STUDY; SYSTEMIC VASCULAR RESISTANCE; BLOOD PRESSURE; BODY POSTURE; LEG; PHYSIOLOGY; PREGNANCY; SAMPLE SIZE; SECOND TRIMESTER PREGNANCY; VASCULAR RESISTANCE;

EID: 84899634146     PISSN: None     EISSN: 19326203     Source Type: Journal    
DOI: 10.1371/journal.pone.0094629     Document Type: Article
Times cited : (16)

References (48)
  • 1
    • 47549096309 scopus 로고    scopus 로고
    • Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares
    • Marik PE, Baram M, Vahid B (2008) Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest 134: 172-178.
    • (2008) Chest , vol.134 , pp. 172-178
    • Marik, P.E.1    Baram, M.2    Vahid, B.3
  • 2
    • 31744438011 scopus 로고    scopus 로고
    • Functional hemodynamic monitoring
    • Pinsky MR, Payen D (2005) Functional hemodynamic monitoring. Crit Care 9: 566-572.
    • (2005) Crit Care , vol.9 , pp. 566-572
    • Pinsky, M.R.1    Payen, D.2
  • 5
    • 33646577770 scopus 로고    scopus 로고
    • Passive leg raising predicts fluid responsiveness in the critically ill
    • Monnet X, Rienzo M, Osman D, Anguel N, Richard C, et al. (2006) Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med 34: 1402-1407.
    • (2006) Crit Care Med , vol.34 , pp. 1402-1407
    • Monnet, X.1    Rienzo, M.2    Osman, D.3    Anguel, N.4    Richard, C.5
  • 6
    • 67949121951 scopus 로고    scopus 로고
    • Non-invasive stroke volume measurement and passive leg raising predict volume responsiveness in medical ICU patients: An observational cohort study
    • Thiel SW, Kollef MH, Isakow W (2009) Non-invasive stroke volume measurement and passive leg raising predict volume responsiveness in medical ICU patients: an observational cohort study. Crit care 13: R111.
    • (2009) Crit Care , vol.13
    • Thiel, S.W.1    Kollef, M.H.2    Isakow, W.3
  • 7
    • 77955925229 scopus 로고    scopus 로고
    • Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: Systematic review and meta-analysis of clinical studies
    • Cavallaro F, Sandroni C, Marano C, La Torre G, Mannocci A, et al. (2010) Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies. Intensive Care Med 36: 1475-1483.
    • (2010) Intensive Care Med , vol.36 , pp. 1475-1483
    • Cavallaro, F.1    Sandroni, C.2    Marano, C.3    La Torre, G.4    Mannocci, A.5
  • 8
    • 0020053103 scopus 로고
    • Passive leg raising does not produce a significant or sustained autotransfusion effect
    • Gaffney FA, Bastian BC, Thal ER, Atkins JM, Blomqvist CG (1982) Passive leg raising does not produce a significant or sustained autotransfusion effect. J Trauma 22: 190-193. (Pubitemid 12133752)
    • (1982) Journal of Trauma , vol.22 , Issue.3 , pp. 190-193
    • Gaffney, F.A.1    Bastian, B.C.2    Thal, E.R.3
  • 11
    • 42449116210 scopus 로고    scopus 로고
    • Ability of pleth variability index to detect hemodynamic changes induced by passive leg raising in spontaneously breathing volunteers
    • Keller G, Cassar E, Desebbe O, Lehot JJ, Cannesson M (2008) Ability of pleth variability index to detect hemodynamic changes induced by passive leg raising in spontaneously breathing volunteers. Crit Care 12: R37.
    • (2008) Crit Care , vol.12
    • Keller, G.1    Cassar, E.2    Desebbe, O.3    Lehot, J.J.4    Cannesson, M.5
  • 13
    • 84984088527 scopus 로고
    • Increase in plasma volume during normal pregnancy
    • Hytten FE, Paintin DB (1963) Increase in plasma volume during normal pregnancy. J Obstet Gynaecol Br Emp 70: 402-407.
    • (1963) J Obstet Gynaecol Br Emp , vol.70 , pp. 402-407
    • Hytten, F.E.1    Paintin, D.B.2
  • 16
    • 0026719380 scopus 로고
    • Adaptation of the maternal heart in pregnancy
    • Hunter S, Robson SC (1992) Adaptation of the maternal heart in pregnancy. Br Heart J 68: 540-543. (Pubitemid 23001727)
    • (1992) British Heart Journal , vol.68 , Issue.6 , pp. 540-543
    • Hunter, S.1    Robson, S.C.2
  • 17
    • 0018123659 scopus 로고
    • Effects of a natural volume overload state (pregnancy) on left ventricular performance in normal human subjects
    • Katz R, Karliner JS, Resnik R (1978) Effects of a natural volume overload state (pregnancy) on left ventricular performance in normal human subjects. Circulation 58: 434-441. (Pubitemid 9006970)
    • (1978) Circulation , vol.58 , Issue.3 , pp. 434-441
    • Katz, R.1    Karliner, J.S.2    Resnik, R.3
  • 19
    • 0015820627 scopus 로고
    • A study of angiotensin II pressor response throughout primigravid pregnancy
    • Gant NF, Daley GL, Chand S, Whalley PJ, MacDonald PC (1973) A study of angiotensin II pressor response throughout primigravid pregnancy. J Clin Invest 52: 2682-2689.
    • (1973) J Clin Invest , vol.52 , pp. 2682-2689
    • Gant, N.F.1    Daley, G.L.2    Chand, S.3    Whalley, P.J.4    Macdonald, P.C.5
  • 21
    • 0023799984 scopus 로고
    • The hemodynamic effects of orthostatic stress during pregnancy
    • Easterling TR, Schmucker BC, Benedetti TJ (1988) The hemodynamic effects of orthostatic stress during pregnancy. Obstet Gynecol 72: 550-552.
    • (1988) Obstet Gynecol , vol.72 , pp. 550-552
    • Easterling, T.R.1    Schmucker, B.C.2    Benedetti, T.J.3
  • 22
    • 0028930714 scopus 로고
    • Relationship between plasma volume, carotid baroreceptor sensitivity and orthostatic tolerance
    • el-Sayed H, Hainsworth R (1995) Relationship between plasma volume, carotid baroreceptor sensitivity and orthostatic tolerance. Clin Sci (Lond) 88: 463-470.
    • (1995) Clin Sci (Lond) , vol.88 , pp. 463-470
    • El-Sayed, H.1    Hainsworth, R.2
  • 23
    • 0024720636 scopus 로고
    • A formula to estimate the approximate surface area if height and weight be known
    • Du Bois, BD, Du Bois EF (1989) A formula to estimate the approximate surface area if height and weight be known. 1916. Nutrition 5: 303-311.
    • (1989) 1916. Nutrition , vol.5 , pp. 303-311
    • Du Bois, B.D.1    Du Bois, E.F.2
  • 24
    • 77952281721 scopus 로고    scopus 로고
    • A longitudinal study of the relationship between maternal cardiac output measured by impedance cardiography and uterine artery blood flow in the second half of pregnancy
    • Flo K, Wilsgaard T, Vartun A , Acharya G (2010) A longitudinal study of the relationship between maternal cardiac output measured by impedance cardiography and uterine artery blood flow in the second half of pregnancy. BJOG 117: 837-844.
    • (2010) BJOG , vol.117 , pp. 837-844
    • Flo, K.1    Wilsgaard, T.2    Acharya, G.3
  • 25
    • 84874059490 scopus 로고    scopus 로고
    • The use of Bioreactance and Carotid Doppler to Determine Volume Responsivenss and Blood Flow Redistribution Following Passive Leg Raising in Hemodynamically Unstable Patients
    • Marik PE, Levitov A, Young A, Andrews L (2013) The use of Bioreactance and Carotid Doppler to Determine Volume Responsivenss and Blood Flow Redistribution Following Passive Leg Raising in Hemodynamically Unstable Patients. Chest 143: 364-370.
    • (2013) Chest , vol.143 , pp. 364-370
    • Marik, P.E.1    Levitov, A.2    Young, A.3    Andrews, L.4
  • 27
    • 0026633544 scopus 로고
    • Maternal and fetal hemodynamic effects of autologous blood donation during pregnancy
    • Droste S, Sorensen T, Price T, Sayers M, Benedetti T, et al. (1992) Maternal and fetal hemodynamic effects of autologous blood donation during pregnancy. Am J Obstet Gynecol 167: 89-93.
    • (1992) Am J Obstet Gynecol , vol.167 , pp. 89-93
    • Droste, S.1    Sorensen, T.2    Price, T.3    Sayers, M.4    Benedetti, T.5
  • 29
    • 0021800622 scopus 로고
    • Blood volume distribution in the Trendelenburg position
    • DOI 10.1016/S0196-0644(85)80878-7
    • Bivins HG, Knopp R, dos Santos PA (1985) Blood volume distribution in the Trendelenburg position. Ann Emerg Med 14: 641-643. (Pubitemid 15071770)
    • (1985) Annals of Emergency Medicine , vol.14 , Issue.7 , pp. 641-643
    • Bivins, H.G.1    Knopp, R.2    Dos Santos, P.A.L.3
  • 30
    • 24944483663 scopus 로고    scopus 로고
    • Use of the trendelenburg position as the resuscitation position: To T or not to T?
    • Bridges N, Jarquin-Valdivia AA (2005) Use of the Trendelenburg position as the resuscitation position: to T or not to T? Am J Crit Care 14: 364-368. (Pubitemid 41330049)
    • (2005) American Journal of Critical Care , vol.14 , Issue.5 , pp. 364-368
    • Bridges, N.1    Jarquin-Valdivia, A.A.2
  • 31
    • 0026900195 scopus 로고
    • Volume loading of the heart by ''leg up'' position and head down tilting (26 degrees) (HDT)
    • Dirschedl P, Gregull A, Lollgen H (1992) Volume loading of the heart by ''leg up'' position and head down tilting (26 degrees) (HDT). Acta Astronaut 27: 41-43.
    • (1992) Acta Astronaut , vol.27 , pp. 41-43
    • Dirschedl, P.1    Gregull, A.2    Lollgen, H.3
  • 33
    • 0019520514 scopus 로고
    • Radionuclide assessment of peripheral intravascular capacity: A technique to measure intravascular volume changes in the capacitance circulation in man
    • Rutlen DL, Wackers FJ, Zaret BL (1981) Radionuclide assessment of peripheral intravascular capacity: a technique to measure intravascular volume changes in the capacitance circulation in man. Circulation 64: 146-152. (Pubitemid 11078901)
    • (1981) Circulation , vol.64 , Issue.1 , pp. 146-152
    • Rutlen, D.L.1    Wackers Th., F.J.2    Zaret, B.L.3
  • 37
    • 80053997333 scopus 로고    scopus 로고
    • Hemodynamic changes during pregnancy and postpartum: A prospective study using thoracic electrical bioimpedance
    • San-Frutos L, Engels V, Zapardiel I, Perez-Medina T, Almagro-Martinez J, et al. (2011) Hemodynamic changes during pregnancy and postpartum: A prospective study using thoracic electrical bioimpedance. J Matern Fetal Neonatal Med 24: 1333-1340.
    • (2011) J Matern Fetal Neonatal Med , vol.24 , pp. 1333-1340
    • San-Frutos, L.1    Engels, V.2    Zapardiel, I.3    Perez-Medina, T.4    Almagro-Martinez, J.5
  • 39
    • 0022640977 scopus 로고
    • The measurement of cardiac output by electrical impedance plethysmography in pregnancy. Are the assumptions valid?
    • de Swiet M, Talbert DG (1986) The measurement of cardiac output by electrical impedance plethysmography in pregnancy. Are the assumptions valid? Br J Obstet Gynaecol 93: 721-726. (Pubitemid 16097497)
    • (1986) British Journal of Obstetrics and Gynaecology , vol.93 , Issue.7 , pp. 721-726
    • De Swiet, M.1    Talbert, D.G.2
  • 41
    • 84872942702 scopus 로고    scopus 로고
    • Transthoracic impedance compared to magnetic resonance imaging in the assessment of cardiac output
    • Villacorta Jr. H, Villacorta AS, Amador F, Hadlich M, Albuquerque DC, et al. (2012) Transthoracic impedance compared to magnetic resonance imaging in the assessment of cardiac output. Arq Bras Cardiol 99: 1149-1155.
    • (2012) Arq Bras Cardiol , vol.99 , pp. 1149-1155
    • Villacorta Jr., H.1    Villacorta, A.S.2    Amador, F.3    Hadlich, M.4    Albuquerque, D.C.5
  • 43
    • 34247465511 scopus 로고    scopus 로고
    • Impedance cardiography: A valuable method of evaluating haemodynamic parameters
    • Sodolski T, Kutarski A (2007) Impedance cardiography: A valuable method of evaluating Hemodynamic parameters. Cardiol J 14: 115-126. (Pubitemid 46656819)
    • (2007) Folia Cardiologica , vol.14 , Issue.2 , pp. 115-126
    • Sodolski, T.1    Kutarski, A.2
  • 44
    • 84866174627 scopus 로고    scopus 로고
    • Impedance cardiography in uncomplicated pregnancy and pre-eclampsia: A reliability study
    • Tomsin K, Mesens T, Molenberghs G, Gyselaers W (2012) Impedance cardiography in uncomplicated pregnancy and pre-eclampsia: a reliability study. J Obstet Gynaecol 32: 630-634.
    • (2012) J Obstet Gynaecol , vol.32 , pp. 630-634
    • Tomsin, K.1    Mesens, T.2    Molenberghs, G.3    Gyselaers, W.4
  • 45
    • 84883462652 scopus 로고    scopus 로고
    • Noninvasive cardiac monitoring in pregnancy: Impedance cardiography versus echocardiography
    • Burlingame J, Ohana P, Aaronoff M, Seto T (2013) Noninvasive cardiac monitoring in pregnancy: impedance cardiography versus echocardiography. Journal of Perinatol 33: 675-680.
    • (2013) Journal of Perinatol , vol.33 , pp. 675-680
    • Burlingame, J.1    Ohana, P.2    Aaronoff, M.3    Seto, T.4
  • 46
    • 84893478957 scopus 로고    scopus 로고
    • Assessing the accuracy of pregnant women in recalling pre-pregnancy weight and gestational weight gain
    • Russell A, Gillespie S, Satay S, Gaudet LM (2013) Assessing the accuracy of pregnant women in recalling pre-pregnancy weight and gestational weight gain. J Obstet Gynaecol Can 35: 802-809.
    • (2013) J Obstet Gynaecol Can , vol.35 , pp. 802-809
    • Russell, A.1    Gillespie, S.2    Satay, S.3    Gaudet, L.M.4
  • 48
    • 58549089484 scopus 로고    scopus 로고
    • Passive leg raising for predicting fluid responsiveness: Importance of the postural change
    • Jabot J, Teboul JL, Richard C, Monnet X (2009) Passive leg raising for predicting fluid responsiveness: importance of the postural change. Intensive Care Med 35: 85-90.
    • (2009) Intensive Care Med , vol.35 , pp. 85-90
    • Jabot, J.1    Teboul, J.L.2    Richard, C.3    Monnet, X.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.