Volumn 489, Issue 1, 2014, Pages

The influence of Monte Carlo source parameters on detector design and dose perturbation in small field dosimetry

Author keywords

[No Author keywords available]

Indexed keywords

C++ (PROGRAMMING LANGUAGE); COMPUTER SOFTWARE; DISSOCIATION; DOSIMETRY; ELECTRON ENERGY LEVELS; INTELLIGENT SYSTEMS; RADIOTHERAPY;

EID: 84899543486     PISSN: 17426588     EISSN: 17426596     Source Type: Conference Proceeding    
DOI: 10.1088/1742-6596/489/1/012006     Document Type: Conference Paper
Times cited : (3)

References (16)
  • 3
    • 37549052531 scopus 로고    scopus 로고
    • Small fields: Nonequilibrium radiation dosimetry
    • 10.1118/1.2815356 0094-2405
    • Das, I J, Ding G X and Ahnesjö A 2008 Small fields: Nonequilibrium radiation dosimetry. Medical Phys. 35 (1) 206
    • (2008) Medical Phys. , vol.35 , Issue.1 , pp. 206
    • Das, I.J.1    Ding, G.X.2    Ahnesjö, A.3
  • 5
    • 79955590055 scopus 로고    scopus 로고
    • A contemporary review of stereotactic radiotherapy: Inherent dosimetric complexities and the potential for detriment
    • 10.3109/0284186X.2010.551665 0284-186X
    • Taylor, M L, Kron T and Franich R D 2011 A contemporary review of stereotactic radiotherapy: inherent dosimetric complexities and the potential for detriment. Acta Oncol 50 (4) 483-508
    • (2011) Acta Oncol , vol.50 , Issue.4 , pp. 483-508
    • Taylor, M.L.1    Kron, T.2    Franich, R.D.3
  • 6
    • 82755181817 scopus 로고    scopus 로고
    • Implementing a newly proposed Monte Carlo based small field dosimetry formalism for a comprehensive set of diode detectors
    • 10.1118/1.3658572 0094-2405
    • Cranmer-Sargison G, Weston S, Evans J A, Sidhu N P and Thwaites D I 2011 Implementing a newly proposed Monte Carlo based small field dosimetry formalism for a comprehensive set of diode detectors. Medical Phys. 38 (12) 6592-6602
    • (2011) Medical Phys. , vol.38 , Issue.12 , pp. 6592-6602
    • Cranmer-Sargison, G.1    Weston, S.2    Evans, J.A.3    Sidhu, N.P.4    Thwaites, D.I.5
  • 7
    • 82755163844 scopus 로고    scopus 로고
    • Calculation of k(Q(clin),Q(msr)) (f(clin),f(msr)) for several small detectors and for two linear accelerators using Monte Carlo simulations
    • 10.1118/1.3660770 0094-2405
    • Francescon P, Cora S and Satariano N 2011 Calculation of k(Q(clin),Q(msr)) (f(clin),f(msr)) for several small detectors and for two linear accelerators using Monte Carlo simulations. Medical Phys. 38 (12) 6513-6527
    • (2011) Medical Phys. , vol.38 , Issue.12 , pp. 6513-6527
    • Francescon, P.1    Cora, S.2    Satariano, N.3
  • 8
    • 84862001085 scopus 로고    scopus 로고
    • Monte Carlo simulated correction factors for machine specific reference field dose calibration and output factor measurement using fixed and iris collimators on the CyberKnife system
    • 0031-9155 3741
    • Francescon P, Kilby W, Satariano N and Cora S 2012 Monte Carlo simulated correction factors for machine specific reference field dose calibration and output factor measurement using fixed and iris collimators on the CyberKnife system. Phys Med Biol 57 (12) 3741-3758
    • (2012) Phys Med Biol , vol.57 , Issue.12 , pp. 3741-3758
    • Francescon, P.1    Kilby, W.2    Satariano, N.3    Cora, S.4
  • 9
    • 84875927409 scopus 로고    scopus 로고
    • Monte Carlo calculated correction factors for diodes and ion chambers in small photon fields
    • 0031-9155 2431
    • Czarnecki D and Zink K 2013 Monte Carlo calculated correction factors for diodes and ion chambers in small photon fields. Phys Med Biol 58 (8) 2431-2444
    • (2013) Phys Med Biol , vol.58 , Issue.8 , pp. 2431-2444
    • Czarnecki, D.1    Zink, K.2
  • 10
    • 84864428287 scopus 로고    scopus 로고
    • Monte Carlo modelling of diode detectors for small field MV photon dosimetry: Detector model simplification and the sensitivity of correction factors to source parameterization
    • 0031-9155 5141
    • Cranmer-Sargison G, Weston S, Evans J A, Sidhu N P and Thwaites D I 2012 Monte Carlo modelling of diode detectors for small field MV photon dosimetry: detector model simplification and the sensitivity of correction factors to source parameterization. Phys Med Biol 57 (16) 5141-5153
    • (2012) Phys Med Biol , vol.57 , Issue.16 , pp. 5141-5153
    • Cranmer-Sargison, G.1    Weston, S.2    Evans, J.A.3    Sidhu, N.P.4    Thwaites, D.I.5
  • 11
    • 84863524239 scopus 로고    scopus 로고
    • Characterizing the influence of detector density on dosimeter response in non-equilibrium small photon fields
    • 0031-9155 4461
    • Scott, A J, Kumar S, Nahum A E and Fenwick J D 2012 Characterizing the influence of detector density on dosimeter response in non-equilibrium small photon fields. Phys Med Biol 57 (14) 4461-4476
    • (2012) Phys Med Biol , vol.57 , Issue.14 , pp. 4461-4476
    • Scott, A.J.1    Kumar, S.2    Nahum, A.E.3    Fenwick, J.D.4
  • 12
    • 84876503686 scopus 로고    scopus 로고
    • Using cavity theory to describe the dependence on detector density of dosimeter response in non-equilibrium small fields
    • 0031-9155 2901
    • Fenwick, J D, Kumar S, Scott A J and Nahum A E 2013 Using cavity theory to describe the dependence on detector density of dosimeter response in non-equilibrium small fields. Phys Med Biol 58 (9) 2901-2923
    • (2013) Phys Med Biol , vol.58 , Issue.9 , pp. 2901-2923
    • Fenwick, J.D.1    Kumar, S.2    Scott, A.J.3    Nahum, A.E.4
  • 13
    • 0029035150 scopus 로고
    • BEAM: A Monte Carlo code to simulate radiotherapy treatment units
    • 10.1118/1.597552 0094-2405
    • Rogers D W O, Faddegon B A, Ding G X, Ma C M and We J 1995 BEAM: A Monte Carlo code to simulate radiotherapy treatment units. Medical Phys. 22 (5) 503-524
    • (1995) Medical Phys. , vol.22 , Issue.5 , pp. 503-524
    • Rogers, D.W.O.1    Faddegon, B.A.2    Ding, G.X.3    Ma, C.M.4    We, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.