메뉴 건너뛰기




Volumn 71, Issue 5, 2014, Pages 1813-1818

Dynamic slice-dependent shim and center frequency update in 3 T breast diffusion weighted imaging

Author keywords

breast; DWI; dynamic shim; EPI; susceptibility

Indexed keywords

IMAGE ENHANCEMENT; IMAGE REGISTRATION; MAGNETIC SUSCEPTIBILITY; PIXELS; SHIMS; SURFACE DIFFUSION;

EID: 84899433672     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24824     Document Type: Article
Times cited : (27)

References (17)
  • 1
    • 73449130199 scopus 로고    scopus 로고
    • Quantitative diffusion-weighted imaging as an adjunct to conventional breast MRI for improved positive predictive value
    • Partridge SC, DeMartini WB, Kurland BF, Eby PR, White SW, Lehman CD,. Quantitative diffusion-weighted imaging as an adjunct to conventional breast MRI for improved positive predictive value. Am J Roentgenol 2009; 193: 1716-1722.
    • (2009) Am J Roentgenol , vol.193 , pp. 1716-1722
    • Partridge, S.C.1    Demartini, W.B.2    Kurland, B.F.3    Eby, P.R.4    White, S.W.5    Lehman, C.D.6
  • 2
    • 0025298010 scopus 로고
    • 2 limitations and off-resonance effects on spatial resolution and artifacts in echo-planar imaging
    • 2 limitations and off-resonance effects on spatial resolution and artifacts in echo-planar imaging. Magn Reson Med 1990; 14: 123-139.
    • (1990) Magn Reson Med , vol.14 , pp. 123-139
    • Farzaneh, F.1    Riederer, S.J.2    Pelc, N.J.3
  • 8
    • 73349100610 scopus 로고    scopus 로고
    • Magnetic field homogenization of the human prefrontal cortex with a set of localized electrical coils
    • Juchem C, Nixon TW, McIntyre S, Rothman DL, de Graaf RA,. Magnetic field homogenization of the human prefrontal cortex with a set of localized electrical coils. Magn Reson Med 2010; 63: 171-180.
    • (2010) Magn Reson Med , vol.63 , pp. 171-180
    • Juchem, C.1    Nixon, T.W.2    McIntyre, S.3    Rothman, D.L.4    De Graaf, R.A.5
  • 10
    • 0030983944 scopus 로고    scopus 로고
    • Dynamic shimming for multi-slice magnetic resonance imaging
    • Morrell G, Spielman D,. Dynamic shimming for multi-slice magnetic resonance imaging. Magn Reson Med 1997; 38: 477-483.
    • (1997) Magn Reson Med , vol.38 , pp. 477-483
    • Morrell, G.1    Spielman, D.2
  • 11
    • 0030013913 scopus 로고    scopus 로고
    • Dynamic shim updating: A new approach towards optimized whole brain shimming
    • Blamire AM, Rothman DL, Nixon T,. Dynamic shim updating: a new approach towards optimized whole brain shimming. Magn Reson Med 1996; 36: 159-165.
    • (1996) Magn Reson Med , vol.36 , pp. 159-165
    • Blamire, A.M.1    Rothman, D.L.2    Nixon, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.