메뉴 건너뛰기




Volumn 36, Issue 4, 2012, Pages 873-880

Patient-to-patient variation of susceptibility-induced B0 field in bilateral breast MRI

Author keywords

B0 mapping; breast shimming; susceptibility

Indexed keywords

ARTICLE; ECHOMAMMOGRAPHY; FOURIER TRANSFORMATION; HUMAN; IMAGE RECONSTRUCTION; IN VIVO STUDY; MAGNETIC FIELD; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; SIMULATION; THICKNESS;

EID: 84866377205     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.23715     Document Type: Article
Times cited : (15)

References (13)
  • 4
    • 20144364751 scopus 로고    scopus 로고
    • Application of a fourier-based method for rapid calculation of field inhomogeneity due to spatial variation of magnetic susceptibility
    • DOI 10.1002/cmr.b.20034
    • Marques JP, Bowtell R,. Application of a Fourier-based method for rapid calculation of field inhomogeneity due to spatial variation of magnetic susceptibility. Concepts Magn Reson 2005; 25B: 65-78. (Pubitemid 40776540)
    • (2005) Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering , vol.25 , Issue.1 , pp. 65-78
    • Marques, J.P.1    Bowtell, R.2
  • 5
    • 33846873463 scopus 로고    scopus 로고
    • Rapid calculations of susceptibility-induced magnetostatic field perturbations for in vivo magnetic resonance
    • DOI 10.1088/0031-9155/51/24/007, PII S0031915506334008, 007
    • Koch KM, Papademetris X, Rothman DL, de Graaf RA,. Rapid calculations of susceptibility-induced magnetostatic field perturbations for in vivo magnetic resonance. Phys Med Biol 2006; 51: 6381-6402. (Pubitemid 46217628)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.24 , pp. 6381-6402
    • Koch, K.M.1    Papademetris, X.2    Rothman, D.L.3    De Graaf, R.A.4
  • 8
    • 0035088714 scopus 로고    scopus 로고
    • 1 distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model
    • DOI 10.1002/mrm.1092
    • 1 distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model. Magn Reson Med 2001; 45: 692-699. (Pubitemid 32260092)
    • (2001) Magnetic Resonance in Medicine , vol.45 , Issue.4 , pp. 692-699
    • Collins, C.M.1    Smith, M.B.2
  • 13
    • 84874788079 scopus 로고    scopus 로고
    • SAR monitoring and pulse design workflow in parallel transmission at 7 Tesla
    • Stockholm; (abstract 3872)
    • Makhoul K, Hue Y-K, Kini L, et al. SAR monitoring and pulse design workflow in parallel transmission at 7 Tesla. In: Proc ISMRM 18th Scientific Meeting, Stockholm; 2010 (abstract 3872).
    • (2010) Proc ISMRM 18th Scientific Meeting
    • Makhoul, K.1    Hue, Y.-K.2    Kini, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.