메뉴 건너뛰기




Volumn 100, Issue 9, 2014, Pages 691-695

Transcutaneous aortic valve replacement with the edwards SAPIEN XT and medtronic corevalve prosthesis under fluoroscopic guidance and local anaesthesia only

Author keywords

[No Author keywords available]

Indexed keywords

DIMENHYDRINATE; INOTROPIC AGENT; LIDOCAINE; METOCLOPRAMIDE; MIDAZOLAM; PIRITRAMIDE;

EID: 84898489106     PISSN: 13556037     EISSN: 1468201X     Source Type: Journal    
DOI: 10.1136/heartjnl-2013-304918     Document Type: Article
Times cited : (57)

References (13)
  • 1
    • 84898479121 scopus 로고    scopus 로고
    • Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
    • Leon MB, Smith CR, Mack M, et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 2010;21:363.
    • (2010) N Engl J Med , vol.21 , pp. 363
    • Leon, M.B.1    Smith, C.R.2    Mack, M.3
  • 2
    • 79958204372 scopus 로고    scopus 로고
    • Transcatheter versus surgical aortic-valve replacement in high-risk patients
    • Smith CR, Leon MB, Mack MJ, et al. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med 2011;9:2187-98.
    • (2011) N Engl J Med , vol.9 , pp. 2187-2198
    • Smith, C.R.1    Leon, M.B.2    Mack, M.J.3
  • 3
    • 84861577475 scopus 로고    scopus 로고
    • Transfemoral aortic valve replacement with the Edwards SAPIEN and Edwards SAPIEN XT prosthesis using exclusively local anesthesia and fluoroscopic guidance: Feasibility and 30-day outcomes
    • Durand E, Borz B, Godin M, et al. Transfemoral aortic valve replacement with the Edwards SAPIEN and Edwards SAPIEN XT prosthesis using exclusively local anesthesia and fluoroscopic guidance: feasibility and 30-day outcomes. JACC Cardiovasc Interv 2012;5:461-7.
    • (2012) JACC Cardiovasc Interv , vol.5 , pp. 461-467
    • Durand, E.1    Borz, B.2    Godin, M.3
  • 4
    • 84870993083 scopus 로고    scopus 로고
    • Effect of local anesthetic management with conscious sedation in patients undergoing transcatheter aortic valve implantation
    • Yamamoto M, Meguro K, Mouillet G, et al. Effect of local anesthetic management with conscious sedation in patients undergoing transcatheter aortic valve implantation. Am J Cardiol 2013;111:94-9.
    • Am J Cardiol 2013 , vol.111 , pp. 94-99
    • Yamamoto, M.1    Meguro, K.2    Mouillet, G.3
  • 5
    • 84856264422 scopus 로고    scopus 로고
    • Local versus general anesthesia for transfemoral aortic valve implantation
    • Motloch LJ, Rottlaender D, Reda S, et al. Local versus general anesthesia for transfemoral aortic valve implantation. Clin Res Cardiol 2012;101:45-53.
    • (2012) Clin Res Cardiol , vol.101 , pp. 45-53
    • Motloch, L.J.1    Rottlaender, D.2    Reda, S.3
  • 9
    • 78651489907 scopus 로고    scopus 로고
    • Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: A consensus report from the Valve Academic Research Consortium
    • Leon MB, Piazza N, Nikolsky E, et al. Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: A consensus report from the Valve Academic Research Consortium. Eur Heart J 2011;32:205-17.
    • (2011) Eur Heart J , vol.32 , pp. 205-217
    • Leon, M.B.1    Piazza, N.2    Nikolsky, E.3
  • 10
    • 49749212248 scopus 로고
    • Left retrograde cardioangiography in acquired cardiac disease: Technique, indications and interpretations in 700 cases
    • Sellers RD, Levy MJ, Mplatz K, et al. Left retrograde cardioangiography in acquired cardiac disease: Technique, indications and interpretations in 700 cases. Am J Cardiol 1964;14:437-47.
    • (1964) Am J Cardiol , vol.14 , pp. 437-447
    • Sellers, R.D.1    Levy, M.J.2    Mplatz, K.3
  • 11
    • 80051751721 scopus 로고    scopus 로고
    • Outcomes and complications of transcatheter aortic valve replacement using a balloon expandable valve according to the valve academic research consortium (VARC) guidelines
    • Gurvitch R, Toggweiler S, Willson AB, et al. Outcomes and complications of transcatheter aortic valve replacement using a balloon expandable valve according to the valve academic research consortium (VARC) guidelines. Euro Intervention 2011;7:41-8.
    • (2011) Euro Intervention , vol.7 , pp. 41-48
    • Gurvitch, R.1    Toggweiler, S.2    Willson, A.B.3
  • 12
    • 84903695761 scopus 로고    scopus 로고
    • The German Aortic Valve Registry (GARY): In-hospital outcome
    • Sep 10. doi:10.1093/eurheartj/eht381
    • Hamm CW, Möllmann H, Holzhey D, et al. The German Aortic Valve Registry (GARY): in-hospital outcome. Eur Heart J 2013 Sep 10. doi:10.1093/eurheartj/eht381.
    • (2013) Eur Heart J
    • Hamm, C.W.1    Möllmann, H.2    Holzhey, D.3
  • 13
    • 84860436228 scopus 로고    scopus 로고
    • Registry of transcatheter aortic-valve implantation in high-risk patients
    • Gilard M, Eltchaninoff H, Iung B, et al. Registry of transcatheter aortic-valve implantation in high-risk patients. N Engl J Med 2012;366:1705-15.
    • (2012) N Engl J Med , vol.366 , pp. 1705-1715
    • Gilard, M.1    Eltchaninoff, H.2    Iung, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.