메뉴 건너뛰기




Volumn 39, Issue 5, 2014, Pages 1146-1152

Comparison of treadmill exercise stress cardiac MRI to stress echocardiography in healthy volunteers for adequacy of left ventricular endocardial wall visualization: A pilot study

Author keywords

cardiac magnetic resonance imaging; echocardiography; endocardial visualization index; exercise stress

Indexed keywords

ADULT; ARTICLE; CARDIOVASCULAR MAGNETIC RESONANCE; DIASTOLIC BLOOD PRESSURE; ECHOCARDIOGRAPH; ELECTROCARDIOGRAPH; ENDOCARDIUM; FEMALE; HEALTH CARE; HEART LEFT VENTRICLE; HEART RATE; HUMAN; HUMAN EXPERIMENT; IMAGE ANALYSIS; INTERMETHOD COMPARISON; MALE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SCANNER; PILOT STUDY; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; REST; STRESS ECHOCARDIOGRAPHY; SYSTOLIC BLOOD PRESSURE; TIME; TREADMILL EXERCISE; TREADMILL TEST; ULTRASOUND TRANSDUCER; ANATOMY AND HISTOLOGY; COMPARATIVE STUDY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; ECHOCARDIOGRAPHY; ECHOGRAPHY; EXERCISE TEST; HEART LEFT VENTRICLE FUNCTION; HEART VENTRICLE; PHYSIOLOGY; PROCEDURES; REFERENCE VALUE; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY;

EID: 84898411142     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.24263     Document Type: Article
Times cited : (20)

References (33)
  • 1
    • 0032500286 scopus 로고    scopus 로고
    • Exercise echocardiography or exercise SPECT imaging? A meta-analysis of diagnostic test performance
    • Fleischmann KE, Hunink MG, Kuntz KM, Douglas PS,. Exercise echocardiography or exercise SPECT imaging? A meta-analysis of diagnostic test performance. JAMA 1998; 280: 913-920.
    • (1998) JAMA , vol.280 , pp. 913-920
    • Fleischmann, K.E.1    Hunink, M.G.2    Kuntz, K.M.3    Douglas, P.S.4
  • 2
    • 43049148310 scopus 로고    scopus 로고
    • Value of vasodilator stress myocardial contrast echocardiography and magnetic resonance imaging for the differential diagnosis of ischemic versus nonischemic cardiomyopathy
    • Mor-Avi V, Koch R, Holper EM, et al. Value of vasodilator stress myocardial contrast echocardiography and magnetic resonance imaging for the differential diagnosis of ischemic versus nonischemic cardiomyopathy. J Am Soc Echocardiogr 2008; 21: 425-432.
    • (2008) J Am Soc Echocardiogr , vol.21 , pp. 425-432
    • Mor-Avi, V.1    Koch, R.2    Holper, E.M.3
  • 3
    • 0031932407 scopus 로고    scopus 로고
    • Outcome after normal exercise echocardiography and predictors of subsequent cardiac events: Follow-up of 1,325 patients
    • McCully RB, Roger VL, Mahoney DW, et al. Outcome after normal exercise echocardiography and predictors of subsequent cardiac events: follow-up of 1,325 patients. J Am Coll Cardiol 1998; 31: 144-149.
    • (1998) J Am Coll Cardiol , vol.31 , pp. 144-149
    • McCully, R.B.1    Roger, V.L.2    Mahoney, D.W.3
  • 4
    • 84865519649 scopus 로고    scopus 로고
    • Prognostic value of adenosine stress cardiovascular magnetic resonance and dobutamine stress echocardiography in patients with low-risk chest pain
    • Hartlage G, Janik M, Anadiotis A, et al. Prognostic value of adenosine stress cardiovascular magnetic resonance and dobutamine stress echocardiography in patients with low-risk chest pain. Int J Cardiovasc Imaging 2012; 28: 803-812.
    • (2012) Int J Cardiovasc Imaging , vol.28 , pp. 803-812
    • Hartlage, G.1    Janik, M.2    Anadiotis, A.3
  • 5
    • 0025945007 scopus 로고
    • Prognostic value of a treadmill exercise score in outpatients with suspected coronary artery disease
    • Mark DB, Shaw L, Harrell FE Jr, et al. Prognostic value of a treadmill exercise score in outpatients with suspected coronary artery disease. N Engl J Med 1991; 325: 849-853.
    • (1991) N Engl J Med , vol.325 , pp. 849-853
    • Mark, D.B.1    Shaw, L.2    Harrell, Jr.F.E.3
  • 6
    • 55149092326 scopus 로고    scopus 로고
    • American Society of Echocardiography consensus statement on the clinical applications of ultrasonic contrast agents in echocardiography
    • quiz 1281.
    • Mulvagh SL, Rakowski H, Vannan MA, et al. American Society of Echocardiography consensus statement on the clinical applications of ultrasonic contrast agents in echocardiography. J Am Soc Echocardiogr 2008; 21: 1179-1201; quiz 1281.
    • (2008) J Am Soc Echocardiogr , vol.21 , pp. 1179-1201
    • Mulvagh, S.L.1    Rakowski, H.2    Vannan, M.A.3
  • 8
    • 0030060589 scopus 로고    scopus 로고
    • Analysis of interinstitutional observer agreement in interpretation of dobutamine stress echocardiograms
    • Hoffmann R, Lethen H, Marwick T, et al. Analysis of interinstitutional observer agreement in interpretation of dobutamine stress echocardiograms. J Am Coll Cardiol 1996; 27: 330-336.
    • (1996) J Am Coll Cardiol , vol.27 , pp. 330-336
    • Hoffmann, R.1    Lethen, H.2    Marwick, T.3
  • 9
    • 41249084233 scopus 로고    scopus 로고
    • A randomized cross-over study for evaluation of the effect of image optimization with contrast on the diagnostic accuracy of dobutamine echocardiography in coronary artery disease. The OPTIMIZE Trial
    • Plana JC, Mikati IA, Dokainish H, et al. A randomized cross-over study for evaluation of the effect of image optimization with contrast on the diagnostic accuracy of dobutamine echocardiography in coronary artery disease. The OPTIMIZE Trial. JACC Cardiovasc Imaging 2008; 1: 145-152.
    • (2008) JACC Cardiovasc Imaging , vol.1 , pp. 145-152
    • Plana, J.C.1    Mikati, I.A.2    Dokainish, H.3
  • 10
    • 0032862317 scopus 로고    scopus 로고
    • Dobutamine stress echocardiography: Improved endocardial border definition and wall motion analysis with tissue harmonic imaging
    • Zaglavara T, Norton M, Cumberledge B, et al. Dobutamine stress echocardiography: improved endocardial border definition and wall motion analysis with tissue harmonic imaging. J Am Soc Echocardiogr 1999; 12: 706-713.
    • (1999) J Am Soc Echocardiogr , vol.12 , pp. 706-713
    • Zaglavara, T.1    Norton, M.2    Cumberledge, B.3
  • 11
    • 0032948629 scopus 로고    scopus 로고
    • Noninvasive diagnosis of ischemia-induced wall motion abnormalities with the use of high-dose dobutamine stress MRI: Comparison with dobutamine stress echocardiography
    • Nagel E, Lehmkuhl HB, Bocksch W, et al. Noninvasive diagnosis of ischemia-induced wall motion abnormalities with the use of high-dose dobutamine stress MRI: comparison with dobutamine stress echocardiography. Circulation 1999; 99: 763-770.
    • (1999) Circulation , vol.99 , pp. 763-770
    • Nagel, E.1    Lehmkuhl, H.B.2    Bocksch, W.3
  • 12
    • 0032589502 scopus 로고    scopus 로고
    • Influence of image quality on the diagnostic accuracy of dobutamine stress magnetic resonance imaging in comparison with dobutamine stress echocardiography for the noninvasive detection of myocardial ischemia
    • Nagel E, Lehmkuhl HB, Klein C, et al. Influence of image quality on the diagnostic accuracy of dobutamine stress magnetic resonance imaging in comparison with dobutamine stress echocardiography for the noninvasive detection of myocardial ischemia. Z Kardiol 1999; 88: 622-630.
    • (1999) Z Kardiol , vol.88 , pp. 622-630
    • Nagel, E.1    Lehmkuhl, H.B.2    Klein, C.3
  • 13
    • 34247282700 scopus 로고    scopus 로고
    • Prognostic value of cardiac magnetic resonance stress tests: Adenosine stress perfusion and dobutamine stress wall motion imaging
    • Jahnke C, Nagel E, Gebker R, et al. Prognostic value of cardiac magnetic resonance stress tests: adenosine stress perfusion and dobutamine stress wall motion imaging. Circulation 2007; 115: 1769-1776.
    • (2007) Circulation , vol.115 , pp. 1769-1776
    • Jahnke, C.1    Nagel, E.2    Gebker, R.3
  • 14
    • 34548814710 scopus 로고    scopus 로고
    • Diagnostic performance of stress cardiac magnetic resonance imaging in the detection of coronary artery disease: A meta-analysis
    • Nandalur KR, Dwamena BA, Choudhri AF, Nandalur MR, Carlos RC,. Diagnostic performance of stress cardiac magnetic resonance imaging in the detection of coronary artery disease: a meta-analysis. J Am Coll Cardiol 2007; 50: 1343-1353.
    • (2007) J Am Coll Cardiol , vol.50 , pp. 1343-1353
    • Nandalur, K.R.1    Dwamena, B.A.2    Choudhri, A.F.3    Nandalur, M.R.4    Carlos, R.C.5
  • 15
    • 73449103540 scopus 로고    scopus 로고
    • Validation of magnetic resonance myocardial perfusion imaging with fractional flow reserve for the detection of significant coronary heart disease
    • Watkins S, McGeoch R, Lyne J, et al. Validation of magnetic resonance myocardial perfusion imaging with fractional flow reserve for the detection of significant coronary heart disease. Circulation 2009; 120: 2207-2213.
    • (2009) Circulation , vol.120 , pp. 2207-2213
    • Watkins, S.1    McGeoch, R.2    Lyne, J.3
  • 16
    • 84860439743 scopus 로고    scopus 로고
    • Diagnostic performance of noninvasive myocardial perfusion imaging using single-photon emission computed tomography, cardiac magnetic resonance, and positron emission tomography imaging for the detection of obstructive coronary artery disease: A meta-analysis
    • Jaarsma C, Leiner T, Bekkers SC, et al. Diagnostic performance of noninvasive myocardial perfusion imaging using single-photon emission computed tomography, cardiac magnetic resonance, and positron emission tomography imaging for the detection of obstructive coronary artery disease: a meta-analysis. J Am Coll Cardiol 2012; 59: 1719-1728.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 1719-1728
    • Jaarsma, C.1    Leiner, T.2    Bekkers, S.C.3
  • 17
    • 0033925482 scopus 로고    scopus 로고
    • Magnetic resonance pharmacological stress for detecting coronary disease. Comparison with echocardiography
    • Baer FM, Crnac J, Schmidt M, et al. Magnetic resonance pharmacological stress for detecting coronary disease. Comparison with echocardiography. Herz 2000; 25: 400-408.
    • (2000) Herz , vol.25 , pp. 400-408
    • Baer, F.M.1    Crnac, J.2    Schmidt, M.3
  • 18
    • 0032578993 scopus 로고    scopus 로고
    • Prognostic value of treadmill exercise testing: A population-based study in Olmsted County, Minnesota
    • Roger VL, Jacobsen SJ, Pellikka PA, Miller TD, Bailey KR, Gersh BJ,. Prognostic value of treadmill exercise testing: a population-based study in Olmsted County, Minnesota. Circulation 1998; 98: 2836-2841.
    • (1998) Circulation , vol.98 , pp. 2836-2841
    • Roger, V.L.1    Jacobsen, S.J.2    Pellikka, P.A.3    Miller, T.D.4    Bailey, K.R.5    Gersh, B.J.6
  • 19
    • 0035090036 scopus 로고    scopus 로고
    • Stress testing in cardiac evaluation: Current concepts with emphasis on the ECG
    • Tavel ME,. Stress testing in cardiac evaluation: current concepts with emphasis on the ECG. Chest 2001; 119: 907-925.
    • (2001) Chest , vol.119 , pp. 907-925
    • Tavel, M.E.1
  • 20
    • 84858203399 scopus 로고    scopus 로고
    • Design and testing of an MRI-compatible cycle ergometer for non-invasive cardiac assessments during exercise
    • Gusso S, Salvador C, Hofman P, et al. Design and testing of an MRI-compatible cycle ergometer for non-invasive cardiac assessments during exercise. Biomed Eng Online 2012; 11: 13.
    • (2012) Biomed Eng Online , vol.11 , pp. 13
    • Gusso, S.1    Salvador, C.2    Hofman, P.3
  • 21
    • 0041508605 scopus 로고    scopus 로고
    • Feasibility to detect severe coronary artery stenoses with upright treadmill exercise magnetic resonance imaging
    • Rerkpattanapipat P, Gandhi SK, Darty SN, et al. Feasibility to detect severe coronary artery stenoses with upright treadmill exercise magnetic resonance imaging. Am J Cardiol 2003; 92: 603-606.
    • (2003) Am J Cardiol , vol.92 , pp. 603-606
    • Rerkpattanapipat, P.1    Gandhi, S.K.2    Darty, S.N.3
  • 22
    • 40949122448 scopus 로고    scopus 로고
    • Cardiac function and myocardial perfusion immediately following maximal treadmill exercise inside the MRI room
    • Jekic M, Foster EL, Ballinger MR, Raman SV, Simonetti OP,. Cardiac function and myocardial perfusion immediately following maximal treadmill exercise inside the MRI room. J Cardiovasc Magn Reson 2008; 10: 3.
    • (2008) J Cardiovasc Magn Reson , vol.10 , pp. 3
    • Jekic, M.1    Foster, E.L.2    Ballinger, M.R.3    Raman, S.V.4    Simonetti, O.P.5
  • 23
    • 77956159323 scopus 로고    scopus 로고
    • Real-time cine and myocardial perfusion with treadmill exercise stress cardiovascular magnetic resonance in patients referred for stress SPECT
    • Raman SV, Dickerson JA, Jekic M, et al. Real-time cine and myocardial perfusion with treadmill exercise stress cardiovascular magnetic resonance in patients referred for stress SPECT. J Cardiovasc Magn Reson 2010; 12: 41.
    • (2010) J Cardiovasc Magn Reson , vol.12 , pp. 41
    • Raman, S.V.1    Dickerson, J.A.2    Jekic, M.3
  • 24
    • 56349084337 scopus 로고    scopus 로고
    • Treadmill stress cardiac magnetic resonance imaging: First in vivo demonstration of exercise-induced apical ballooning
    • Raman SV, Richards DR, Jekic M, et al. Treadmill stress cardiac magnetic resonance imaging: first in vivo demonstration of exercise-induced apical ballooning. J Am Coll Cardiol 2008; 52: 1884.
    • (2008) J Am Coll Cardiol , vol.52 , pp. 1884
    • Raman, S.V.1    Richards, D.R.2    Jekic, M.3
  • 25
    • 84857366457 scopus 로고    scopus 로고
    • MR-compatible treadmill for exercise stress cardiac magnetic resonance imaging
    • Foster EL, Arnold JW, Jekic M, et al. MR-compatible treadmill for exercise stress cardiac magnetic resonance imaging. Magn Reson Med 2012; 67: 880-889.
    • (2012) Magn Reson Med , vol.67 , pp. 880-889
    • Foster, E.L.1    Arnold, J.W.2    Jekic, M.3
  • 26
    • 33750186300 scopus 로고
    • Exercising testing in adult normal subjects and cardiac patients
    • Bruce RA, Blackmon JR, Jones JW, Strait G,. Exercising testing in adult normal subjects and cardiac patients. Pediatrics 1963; 32 (Suppl): 742-756.
    • (1963) Pediatrics , vol.32 , Issue.SUPPL. , pp. 742-756
    • Bruce, R.A.1    Blackmon, J.R.2    Jones, J.W.3    Strait, G.4
  • 27
    • 0033556412 scopus 로고    scopus 로고
    • Comparison of native and contrast-enhanced harmonic echocardiography for visualization of left ventricular endocardial border
    • Kasprzak JD, Paelinck B, Ten Cate FJ, et al. Comparison of native and contrast-enhanced harmonic echocardiography for visualization of left ventricular endocardial border. Am J Cardiol 1999; 83: 211-217.
    • (1999) Am J Cardiol , vol.83 , pp. 211-217
    • Kasprzak, J.D.1    Paelinck, B.2    Ten Cate, F.J.3
  • 28
    • 0032798499 scopus 로고    scopus 로고
    • Improved endocardial visualization with second harmonic imaging compared with fundamental two-dimensional echocardiographic imaging
    • Senior R, Soman P, Khattar RS, Lahiri A,. Improved endocardial visualization with second harmonic imaging compared with fundamental two-dimensional echocardiographic imaging. Am Heart J 1999; 138 (1 Pt 1): 163-168.
    • (1999) Am Heart J , vol.138 , Issue.1 PART 1 , pp. 163-168
    • Senior, R.1    Soman, P.2    Khattar, R.S.3    Lahiri, A.4
  • 30
    • 0035797845 scopus 로고    scopus 로고
    • Exercise standards for testing and training: A statement for healthcare professionals from the American Heart Association
    • Fletcher GF, Balady GJ, Amsterdam EA, et al. Exercise standards for testing and training: a statement for healthcare professionals from the American Heart Association. Circulation 2001; 104: 1694-1740.
    • (2001) Circulation , vol.104 , pp. 1694-1740
    • Fletcher, G.F.1    Balady, G.J.2    Amsterdam, E.A.3
  • 31
    • 0033819521 scopus 로고    scopus 로고
    • American College of Cardiology/American Heart Association clinical competence statement on stress testing: A report of the American College of Cardiology/American Heart Association/American College of Physicians-American Society of Internal Medicine Task Force on Clinical Competence
    • Rodgers GP, Ayanian JZ, Balady G, et al. American College of Cardiology/American Heart Association clinical competence statement on stress testing: a report of the American College of Cardiology/American Heart Association/American College of Physicians-American Society of Internal Medicine Task Force on Clinical Competence. J Am Coll Cardiol 2000; 36: 1441-1453.
    • (2000) J Am Coll Cardiol , vol.36 , pp. 1441-1453
    • Rodgers, G.P.1    Ayanian, J.Z.2    Balady, G.3
  • 32
    • 79953126968 scopus 로고    scopus 로고
    • Adenosine stress myocardial contrast echocardiography for the detection of coronary artery disease: A comparison with coronary angiography and cardiac magnetic resonance
    • Arnold JR, Karamitsos TD, Pegg TJ, et al. Adenosine stress myocardial contrast echocardiography for the detection of coronary artery disease: a comparison with coronary angiography and cardiac magnetic resonance. JACC Cardiovasc Imaging 2010; 3: 934-943.
    • (2010) JACC Cardiovasc Imaging , vol.3 , pp. 934-943
    • Arnold, J.R.1    Karamitsos, T.D.2    Pegg, T.J.3
  • 33
    • 34548251036 scopus 로고    scopus 로고
    • American Society of Echocardiography recommendations for performance, interpretation, and application of stress echocardiography
    • Pellikka PA, Nagueh SF, Elhendy AA, Kuehl CA, Sawada SG,. American Society of Echocardiography recommendations for performance, interpretation, and application of stress echocardiography. J Am Soc Echocardiogr 2007; 20: 1021-1041.
    • (2007) J Am Soc Echocardiogr , vol.20 , pp. 1021-1041
    • Pellikka, P.A.1    Nagueh, S.F.2    Elhendy, A.A.3    Kuehl, C.A.4    Sawada, S.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.