메뉴 건너뛰기




Volumn 3, Issue 1, 2013, Pages 107-121

An appropriate wind model for wind integrated power systems reliability evaluation considering wind speed correlations

Author keywords

Analytical technique; Correlation; Probabilistic model; Reliability; Wind penetration; Wind power

Indexed keywords


EID: 84898018833     PISSN: None     EISSN: 20763417     Source Type: Journal    
DOI: 10.3390/app3010107     Document Type: Article
Times cited : (39)

References (18)
  • 1
    • 85107084631 scopus 로고    scopus 로고
    • (accessed on 29 December 2012)
    • Wind by the Numbers: Economic Benefits of Wind Energy. Canadian Wind Energy Association Web Site. Available online: http://www.canwea.ca/images/uploads/File/NRCan_-_Fact_Sheets/canwea-factsheet-economic-web.pdf (accessed on 29 December 2012)
    • Canadian Wind Energy Association Web Site
  • 3
    • 0020497503 scopus 로고
    • Development of a new procedure for reliability modeling of wind turbine generators
    • Giorsetto, P.; Utsurogi, K.F. Development of a new procedure for reliability modeling of wind turbine generators. IEEE Trans. Power Appar. Syst. 1983, 1, 134-143
    • (1983) IEEE Trans. Power Appar. Syst , vol.1 , pp. 134-143
    • Giorsetto, P.1    Utsurogi, K.F.2
  • 4
    • 0036969703 scopus 로고    scopus 로고
    • Probabilistic model of a two-site wind energy conversion system
    • Karaki, S.H.; Salim, B.A.; Chedid, R.B. Probabilistic model of a two-site wind energy conversion system. IEEE Trans. Energy Convers. 2002, 17, 530-536
    • (2002) IEEE Trans. Energy Convers , vol.17 , pp. 530-536
    • Karaki, S.H.1    Salim, B.A.2    Chedid, R.B.3
  • 6
    • 33947319093 scopus 로고    scopus 로고
    • Considering load-carrying capability and wind speed correlation of WECS in generation adequacy assessment
    • Wangdee, W.; Billinton, R. Considering load-carrying capability and wind speed correlation of WECS in generation adequacy assessment. IEEE Trans. Energy Convers. 2006, 21, 734-741
    • (2006) IEEE Trans. Energy Convers , vol.21 , pp. 734-741
    • Wangdee, W.1    Billinton, R.2
  • 7
    • 65349132534 scopus 로고    scopus 로고
    • Adequacy assessment of generating systems containing wind power considering wind speed correlation
    • Gao, Y.; Billinton, R. Adequacy assessment of generating systems containing wind power considering wind speed correlation. IET Renewable Power Generation 2009, 3, 217-226
    • (2009) IET Renewable Power Generation , vol.3 , pp. 217-226
    • Gao, Y.1    Billinton, R.2
  • 8
    • 84951821441 scopus 로고    scopus 로고
    • Adequacy Assessment of Wind-Integrated Composite Generation and Transmission Systems
    • Anders, G., Vaccaro, A., Eds.; Springer: London, UK
    • Billinton, R.; Gao, Y.; Huang, D.; Karki, R. Adequacy Assessment of Wind-Integrated Composite Generation and Transmission Systems. In Innovations in Power Systems Reliability; Anders, G., Vaccaro, A., Eds.; Springer: London, UK, 2011; pp. 141-167
    • (2011) Innovations in Power Systems Reliability , pp. 141-167
    • Billinton, R.1    Gao, Y.2    Huang, D.3    Karki, R.4
  • 9
    • 42549086105 scopus 로고    scopus 로고
    • Spatially Correlated Wind Speed Modeling for Generation Adequacy Studies in the UK
    • Tampa, FL, USA, June
    • Miranda, M.S.; Dunn, R.W. Spatially Correlated Wind Speed Modeling for Generation Adequacy Studies in the UK. In Proceedings of the Power Engineering Society General Meeting, Tampa, FL, USA, June 2007; pp. 1-6
    • (2007) Proceedings of the Power Engineering Society General Meeting , pp. 1-6
    • Miranda, M.S.1    Dunn, R.W.2
  • 12
    • 0030241740 scopus 로고    scopus 로고
    • Time-series models for reliability evaluation of power systems including wind energy
    • Billinton, R.; Chen, H.; Ghajar, R. Time-series models for reliability evaluation of power systems including wind energy. Microelectron. Reliab. 1996, 36, 1253-1261
    • (1996) Microelectron. Reliab , vol.36 , pp. 1253-1261
    • Billinton, R.1    Chen, H.2    Ghajar, R.3
  • 13
    • 40849098849 scopus 로고    scopus 로고
    • Multistate wind energy conversion system models for adequacy assessment of generating systems incorporating wind energy
    • Billinton, R.; Gao, Y. Multistate wind energy conversion system models for adequacy assessment of generating systems incorporating wind energy. IEEE Trans. Energy Convers. 2008, 23, 163-170
    • (2008) IEEE Trans. Energy Convers , vol.23 , pp. 163-170
    • Billinton, R.1    Gao, Y.2
  • 14
    • 84941185462 scopus 로고
    • The choice of a class interval
    • Sturges, H.A. The choice of a class interval. J. Am. Stat. Assoc. 1926, 21, 65-66
    • (1926) J. Am. Stat. Assoc , vol.21 , pp. 65-66
    • Sturges, H.A.1
  • 17
    • 84919901718 scopus 로고    scopus 로고
    • Power System Research Group, University of Saskatchewan: Saskatoon, SK, Canada
    • Karki, R.; Billinton, R. SIPSIREL User's Manual; Power System Research Group, University of Saskatchewan: Saskatoon, SK, Canada, 1997
    • (1997) SIPSIREL User's Manual
    • Karki, R.1    Billinton, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.