메뉴 건너뛰기




Volumn 121, Issue 4, 2014, Pages 849-854

Diagnostic performance of optical coherence tomography ganglion cell-inner plexiform layer thickness measurements in early glaucoma

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; CROSS-SECTIONAL STUDY; DIAGNOSTIC TEST ACCURACY STUDY; FEMALE; GANGLION CELL INNER PLEXIFORM LAYER; GLAUCOMA; HUMAN; MALE; MIDDLE AGED; NEGATIVE LIKELIHOOD RATIO; OPTIC NERVE; OPTIC NERVE HEAD; OPTICAL COHERENCE TOMOGRAPHY; OPTICAL COHERENCE TOMOGRAPHY DEVICE; POSITIVE LIKELIHOOD RATIO; PRIORITY JOURNAL; PROSPECTIVE STUDY; RETINAL NERVE FIBER LAYER THICKNESS; SENSITIVITY AND SPECIFICITY; STATISTICAL ANALYSIS; VERY ELDERLY; VISUAL SYSTEM PARAMETERS;

EID: 84897954451     PISSN: 01616420     EISSN: 15494713     Source Type: Journal    
DOI: 10.1016/j.ophtha.2013.10.044     Document Type: Article
Times cited : (89)

References (22)
  • 1
    • 84890561950 scopus 로고    scopus 로고
    • The applicability of ganglion cell complex parameters determined from SD-OCT images to detect glaucomatous eyes [report online]
    • Accessed September 26, 2013
    • Arintawati P, Sone T, Akita T, et al. The applicability of ganglion cell complex parameters determined from SD-OCT images to detect glaucomatous eyes [report online]. J Glaucoma. Available at: http://ovidsp.tx.ovid.com. Accessed September 26, 2013.
    • J Glaucoma
    • Arintawati, P.1    Sone, T.2    Akita, T.3
  • 2
    • 84879159525 scopus 로고    scopus 로고
    • Comparison of macular ganglion cell complex thickness by Fourier-domain OCT in normal tension glaucoma and primary open-angle glaucoma
    • N.R. Kim, S. Hong, and J.H. Kim et al. Comparison of macular ganglion cell complex thickness by Fourier-domain OCT in normal tension glaucoma and primary open-angle glaucoma J Glaucoma 22 2013 133 139
    • (2013) J Glaucoma , vol.22 , pp. 133-139
    • Kim, N.R.1    Hong, S.2    Kim, J.H.3
  • 3
    • 79960638234 scopus 로고    scopus 로고
    • Comparing the ganglion cell complex and retinal nerve fibre layer measurements by Fourier domain OCT to detect glaucoma in high myopia
    • N.R. Kim, E.S. Lee, and G.J. Seong et al. Comparing the ganglion cell complex and retinal nerve fibre layer measurements by Fourier domain OCT to detect glaucoma in high myopia Br J Ophthalmol 55 2011 1115 1121
    • (2011) Br J Ophthalmol , vol.55 , pp. 1115-1121
    • Kim, N.R.1    Lee, E.S.2    Seong, G.J.3
  • 4
    • 84861914229 scopus 로고    scopus 로고
    • Glaucoma diagnostic accuracy of ganglion cell-inner plexiform layer thickness: Comparison with nerve fiber layer and optic nerve head
    • J.C. Mwanza, M.K. Durbin, and D.L. Budenz et al. Glaucoma diagnostic accuracy of ganglion cell-inner plexiform layer thickness: comparison with nerve fiber layer and optic nerve head Ophthalmology 119 2012 1151 1158
    • (2012) Ophthalmology , vol.119 , pp. 1151-1158
    • Mwanza, J.C.1    Durbin, M.K.2    Budenz, D.L.3
  • 5
    • 79551570246 scopus 로고    scopus 로고
    • Ability of Cirrus HD-OCT optic nerve head parameters to discriminate normal from glaucomatous eyes
    • J.C. Mwanza, J.D. Oakley, D.L. Budenz, D.R. Anderson, and Cirrus Optical Coherence Tomography Normative Database Study Group Ability of Cirrus HD-OCT optic nerve head parameters to discriminate normal from glaucomatous eyes Ophthalmology 118 2011 241 248
    • (2011) Ophthalmology , vol.118 , pp. 241-248
    • Mwanza, J.C.1    Oakley, J.D.2    Budenz, D.L.3    Anderson, D.R.4
  • 6
    • 79959701337 scopus 로고    scopus 로고
    • Diagnostic ability of retinal ganglion cell complex, retinal nerve fiber layer, and optic nerve head measurements by Fourier-domain optical coherence tomography
    • A. Schulze, J. Lamparter, and N. Pfeiffer et al. Diagnostic ability of retinal ganglion cell complex, retinal nerve fiber layer, and optic nerve head measurements by Fourier-domain optical coherence tomography Graefes Arch Clin Exp Ophthalmol 249 2011 1039 1045
    • (2011) Graefes Arch Clin Exp Ophthalmol , vol.249 , pp. 1039-1045
    • Schulze, A.1    Lamparter, J.2    Pfeiffer, N.3
  • 7
    • 0025011140 scopus 로고
    • Topography of ganglion cells in human retina
    • C.A. Curcio, and K.A. Allen Topography of ganglion cells in human retina J Comp Neurol 300 1990 1 25
    • (1990) J Comp Neurol , vol.300 , pp. 1-25
    • Curcio, C.A.1    Allen, K.A.2
  • 8
    • 84868112058 scopus 로고    scopus 로고
    • Glaucoma discrimination of segmented Cirrus spectral domain optical coherence tomography (SD-OCT) macular scans
    • J. Kotowski, L.S. Folio, and G. Wollstein et al. Glaucoma discrimination of segmented Cirrus spectral domain optical coherence tomography (SD-OCT) macular scans Br J Ophthalmol 96 2012 1420 1425
    • (2012) Br J Ophthalmol , vol.96 , pp. 1420-1425
    • Kotowski, J.1    Folio, L.S.2    Wollstein, G.3
  • 9
    • 84872031816 scopus 로고    scopus 로고
    • A novel method to detect local ganglion cell loss in early glaucoma using spectral-domain optical coherence tomography
    • K. Takayama, M. Hangai, and M. Durbin et al. A novel method to detect local ganglion cell loss in early glaucoma using spectral-domain optical coherence tomography Invest Ophthalmol Vis Sci 53 2012 6904 6913
    • (2012) Invest Ophthalmol Vis Sci , vol.53 , pp. 6904-6913
    • Takayama, K.1    Hangai, M.2    Durbin, M.3
  • 10
    • 11344261778 scopus 로고    scopus 로고
    • Sensitivity and specificity of the StratusOCT for perimetric glaucoma
    • D.L. Budenz, A. Michael, and R.T. Chang et al. Sensitivity and specificity of the StratusOCT for perimetric glaucoma Ophthalmology 112 2005 3 9
    • (2005) Ophthalmology , vol.112 , pp. 3-9
    • Budenz, D.L.1    Michael, A.2    Chang, R.T.3
  • 11
    • 70649094280 scopus 로고    scopus 로고
    • Sensitivity and specificity of time-domain versus spectral-domain optical coherence tomography in diagnosing early to moderate glaucoma
    • R.T. Chang, O.J. Knight, W.J. Feuer, and D.L. Budenz Sensitivity and specificity of time-domain versus spectral-domain optical coherence tomography in diagnosing early to moderate glaucoma Ophthalmology 116 2009 2294 2299
    • (2009) Ophthalmology , vol.116 , pp. 2294-2299
    • Chang, R.T.1    Knight, O.J.2    Feuer, W.J.3    Budenz, D.L.4
  • 12
    • 78651374030 scopus 로고    scopus 로고
    • Diagnostic accuracy of nerve fibre layer, macular thickness and optic disc measurements made with the RTVue-100 optical coherence tomograph to detect glaucoma
    • A. Garas, P. Vargha, and G. Hollo Diagnostic accuracy of nerve fibre layer, macular thickness and optic disc measurements made with the RTVue-100 optical coherence tomograph to detect glaucoma Eye (Lond) 25 2011 57 65
    • (2011) Eye (Lond) , vol.25 , pp. 57-65
    • Garas, A.1    Vargha, P.2    Hollo, G.3
  • 14
    • 79951950723 scopus 로고    scopus 로고
    • Reproducibility of peripapillary retinal nerve fiber layer thickness and optic nerve head parameters measured with Cirrus HD-OCT in glaucomatous eyes
    • J.C. Mwanza, R.T. Chang, and D.L. Budenz et al. Reproducibility of peripapillary retinal nerve fiber layer thickness and optic nerve head parameters measured with Cirrus HD-OCT in glaucomatous eyes Invest Ophthalmol Vis Sci 51 2010 5724 5730
    • (2010) Invest Ophthalmol Vis Sci , vol.51 , pp. 5724-5730
    • Mwanza, J.C.1    Chang, R.T.2    Budenz, D.L.3
  • 15
    • 84856374427 scopus 로고    scopus 로고
    • Macular ganglion cell-inner plexiform layer: Automated detection and thickness reproducibility with spectral domain-optical coherence tomography in glaucoma
    • J.C. Mwanza, J.D. Oakley, and D.L. Budenz et al. Macular ganglion cell-inner plexiform layer: automated detection and thickness reproducibility with spectral domain-optical coherence tomography in glaucoma Invest Ophthalmol Vis Sci 52 2011 8323 8329
    • (2011) Invest Ophthalmol Vis Sci , vol.52 , pp. 8323-8329
    • Mwanza, J.C.1    Oakley, J.D.2    Budenz, D.L.3
  • 16
    • 0036042766 scopus 로고    scopus 로고
    • Simplifying likelihood ratios
    • S. McGee Simplifying likelihood ratios J Gen Intern Med 17 2002 646 649
    • (2002) J Gen Intern Med , vol.17 , pp. 646-649
    • McGee, S.1
  • 17
    • 80052814870 scopus 로고    scopus 로고
    • Novel software strategy for glaucoma diagnosis: Asymmetry analysis of retinal thickness
    • S. Asrani, J.A. Rosdahl, and R.R. Allingham Novel software strategy for glaucoma diagnosis: asymmetry analysis of retinal thickness Arch Ophthalmol 129 2011 1205 1211
    • (2011) Arch Ophthalmol , vol.129 , pp. 1205-1211
    • Asrani, S.1    Rosdahl, J.A.2    Allingham, R.R.3
  • 18
    • 70649100329 scopus 로고    scopus 로고
    • Detection of macular ganglion cell loss in glaucoma by Fourier-domain optical coherence tomography
    • O. Tan, V. Chopra, and A.T. Lu et al. Detection of macular ganglion cell loss in glaucoma by Fourier-domain optical coherence tomography Ophthalmology 116 2009 2305 2314
    • (2009) Ophthalmology , vol.116 , pp. 2305-2314
    • Tan, O.1    Chopra, V.2    Lu, A.T.3
  • 19
    • 84880069613 scopus 로고    scopus 로고
    • Comparative assessment for the ability of Cirrus, RTVue and 3D-OCT to diagnose glaucoma
    • A. Akashi, A. Kanamori, and M. Nakamura et al. Comparative assessment for the ability of Cirrus, RTVue and 3D-OCT to diagnose glaucoma Invest Ophthalmol Vis Sci 54 2013 4478 4484
    • (2013) Invest Ophthalmol Vis Sci , vol.54 , pp. 4478-4484
    • Akashi, A.1    Kanamori, A.2    Nakamura, M.3
  • 20
    • 84879560365 scopus 로고    scopus 로고
    • Macular ganglion cell imaging study: Glaucoma diagnostic accuracy of spectral-domain optical coherence tomography
    • J.W. Jeoung, Y.J. Choi, K.H. Park, and D.M. Kim Macular ganglion cell imaging study: glaucoma diagnostic accuracy of spectral-domain optical coherence tomography Invest Ophthalmol Vis Sci 54 2013 4422 4429
    • (2013) Invest Ophthalmol Vis Sci , vol.54 , pp. 4422-4429
    • Jeoung, J.W.1    Choi, Y.J.2    Park, K.H.3    Kim, D.M.4
  • 21
    • 84876281426 scopus 로고    scopus 로고
    • Rates of abnormal retinal nerve fiber layer and ganglion cell layer OCT scans in healthy myopic eyes: Cirrus versus RTVue
    • J.C. Mwanza, F.E. Sayyad, A.A. Aref, and D.L. Budenz Rates of abnormal retinal nerve fiber layer and ganglion cell layer OCT scans in healthy myopic eyes: Cirrus versus RTVue Ophthalmic Surg Lasers Imaging 43 suppl 2012 S67 S74
    • (2012) Ophthalmic Surg Lasers Imaging , vol.43 , Issue.SUPPL.
    • Mwanza, J.C.1    Sayyad, F.E.2    Aref, A.A.3    Budenz, D.L.4
  • 22
    • 34249671717 scopus 로고    scopus 로고
    • Determinants of normal retinal nerve fiber layer thickness measured by Stratus OCT
    • D.L. Budenz, D.R. Anderson, and R. Varma et al. Determinants of normal retinal nerve fiber layer thickness measured by Stratus OCT Ophthalmology 114 2007 1046 1052
    • (2007) Ophthalmology , vol.114 , pp. 1046-1052
    • Budenz, D.L.1    Anderson, D.R.2    Varma, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.