-
1
-
-
0003393654
-
Power system stability and control
-
Palo Alto, CA, USA
-
P. Kundur, "Power system stability and control," EPRI, Palo Alto, CA, USA, 1994.
-
(1994)
EPRI
-
-
Kundur, P.1
-
2
-
-
33947323248
-
A survey of frequency and voltage control ancillary services - Part I: Technical features
-
DOI 10.1109/TPWRS.2006.888963
-
Y. Rebours, D. S. Kirschen, M. Trotignon, and S. Rossignol, "Asurvey of frequency and voltage control ancillary services-Part 1: Technical features," IEEE Trans. Power Syst., vol. 22, no. 1, pp. 350-357, 2007. (Pubitemid 46442142)
-
(2007)
IEEE Transactions on Power Systems
, vol.22
, Issue.1
, pp. 350-357
-
-
Rebours, Y.G.1
Kirschen, D.S.2
Trotignon, M.3
Rossignol, S.4
-
3
-
-
80052363501
-
Provision of load frequency control by PHEVs, controllable loads, and a cogeneration unit
-
M. D. Galus, S. Koch, and G. Andersson, "Provision of load frequency control by PHEVs, controllable loads, and a cogeneration unit," IEEE Trans. Power Syst., vol. 58, no. 10, pp. 4568-4582, 2011.
-
(2011)
IEEE Trans. Power Syst.
, vol.58
, Issue.10
, pp. 4568-4582
-
-
Galus, M.D.1
Koch, S.2
Andersson, G.3
-
4
-
-
79960894543
-
Demand as frequency controlled reserve
-
Z. Xu, J. Østergaard, and M. Togeby, "Demand as frequency controlled reserve," IEEE Trans. Power Syst., vol. 26, no. 3, pp. 1062-1071, 2011.
-
(2011)
IEEE Trans. Power Syst.
, vol.26
, Issue.3
, pp. 1062-1071
-
-
Xu, Z.1
Østergaard, J.2
Togeby, M.3
-
8
-
-
79151479126
-
Decentralized demand-side contribution to primary frequency control
-
A. Molina-García, F. Bouffard, and D. S. Kirschen, "Decentralized demand-side contribution to primary frequency control," IEEE Trans. Power Syst., vol. 26, no. 1, pp. 411-419, 2011.
-
(2011)
IEEE Trans. Power Syst.
, vol.26
, Issue.1
, pp. 411-419
-
-
Molina-García, A.1
Bouffard, F.2
Kirschen, D.S.3
-
9
-
-
34548033512
-
Stabilization of grid frequency through dynamic demand control
-
DOI 10.1109/TPWRS.2007.901489
-
J. A. Short, D. G. Infield, and L. L. Freris, "Stabilization of grid frequency through dynamic demand control," IEEE Trans. Power Syst., vol. 22, no. 3, pp. 1284-1293, 2007. (Pubitemid 47278388)
-
(2007)
IEEE Transactions on Power Systems
, vol.22
, Issue.3
, pp. 1284-1293
-
-
Short, J.A.1
Infield, D.G.2
Freris, L.L.3
-
10
-
-
77951704406
-
Demand side primary frequency response support through smart meter control
-
K. Samarakoon and J. Ekanayake, "Demand side primary frequency response support through smart meter control," in Proc. 44th Int. Univ. Power Eng. Conf., 2009, pp. 1-5.
-
(2009)
Proc. 44th Int. Univ. Power Eng. Conf.
, pp. 1-5
-
-
Samarakoon, K.1
Ekanayake, J.2
-
11
-
-
84865455550
-
Incorporating demand response with spinning reserve to realize an adaptive frequency restoration plan for system contingencies
-
L. R. Chang-Chie, L. N. An, T. W. Lin, and W. J. Lee, "Incorporating demand response with spinning reserve to realize an adaptive frequency restoration plan for system contingencies," IEEE Trans. Smart Grid, vol. 3, no. 3, pp. 1145-1153, 2012.
-
(2012)
IEEE Trans. Smart Grid
, vol.3
, Issue.3
, pp. 1145-1153
-
-
Chang-Chie, L.R.1
An, L.N.2
Lin, T.W.3
Lee, W.J.4
-
12
-
-
84872060550
-
Real-time central demand response for primary frequency regulation in microgrids
-
S. A. Pourmousavi and M. H. Nehrir, "Real-time central demand response for primary frequency regulation in microgrids," IEEE Trans. Smart Grid, vol. 3, no. 4, pp. 1988-1996, 2012.
-
(2012)
IEEE Trans. Smart Grid
, vol.3
, Issue.4
, pp. 1988-1996
-
-
Pourmousavi, S.A.1
Nehrir, M.H.2
-
13
-
-
0025471860
-
A low-order system frequency response model
-
DOI 10.1109/59.65898
-
P. M. Anderson and M. Mirheydar, "A low-order system frequency response model," IEEE Trans. Power Syst., vol. 5, no. 3, pp. 720-729, 1990. (Pubitemid 20739208)
-
(1990)
IEEE Transactions on Power Systems
, vol.5
, Issue.3
, pp. 720-729
-
-
Anderson, P.M.1
Mirheydar, M.2
-
14
-
-
50249166671
-
Voltage control of aggregate electric water heater load for distribution system peak load shaving using field data
-
R. Jia, M. H. Nehrir, and D. A. Pierre, "Voltage control of aggregate electric water heater load for distribution system peak load shaving using field data," in Proc. 39th North Amer. Power Symp., 2007, pp. 492-497.
-
(2007)
Proc. 39th North Amer. Power Symp.
, pp. 492-497
-
-
Jia, R.1
Nehrir, M.H.2
Pierre, D.A.3
-
15
-
-
27144464588
-
Control strategies of thermostatically controlled appliances in a competitive electricity market
-
2005 IEEE Power Engineering Society General Meeting
-
N. Lu and S. Katipamula, "Control strategies of thermostatically controlled appliances in a competitive electricity market," in Proc. IEEE Power Eng. Soc. Gen. Meet., 2005, pp. 202-207. (Pubitemid 41496921)
-
(2005)
2005 IEEE Power Engineering Society General Meeting
, vol.1
, pp. 202-207
-
-
Lu, N.1
Katipamula, S.2
-
16
-
-
37249020840
-
A phase-locked loop for the synchronization of power quality instruments in the presence of stationary and transient disturbances
-
DOI 10.1109/TIM.2007.908350
-
A. Cataliotti, V. Cosentino, and S. Nuccio, "A phase-locked loop for the synchronization of power quality instruments in the presence of stationary and transient disturbances," IEEE Trans. Instrum. Meas., vol. 56, no. 6, pp. 2232-2239, 2007. (Pubitemid 350268454)
-
(2007)
IEEE Transactions on Instrumentation and Measurement
, vol.56
, Issue.6
, pp. 2232-2239
-
-
Cataliotti, A.1
Cosentino, V.2
Nuccio, S.3
-
19
-
-
84869406024
-
A predictor-based compensation for electro-mechanical delay during neuromuscular electrical stimulation-II
-
N. Sharma, "A predictor-based compensation for electro-mechanical delay during neuromuscular electrical stimulation-II," in Proc. Amer. Control Conf., 2012, pp. 5604-5609.
-
(2012)
Proc. Amer. Control Conf.
, pp. 5604-5609
-
-
Sharma, N.1
|