메뉴 건너뛰기




Volumn 29, Issue 2, 2014, Pages 765-774

Frequency estimation of distorted and noisy signals in power systems by FFT-based approach

Author keywords

Discrete Fourier transform (DFT); frequency estimation; interpolation; spectral leakage; window

Indexed keywords

ANALYTICAL EXPRESSIONS; INTERPOLATION FFT ALGORITHMS; MEASUREMENT CHANNELS; NOISE CONTRIBUTIONS; OPTIMAL PARAMETER; POWER QUALITY ANALYZER; SAMPLING FREQUENCIES; SPECTRAL LEAKAGE;

EID: 84897598209     PISSN: 08858950     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRS.2013.2283273     Document Type: Article
Times cited : (77)

References (29)
  • 1
    • 84860231462 scopus 로고    scopus 로고
    • Dynamic phasor and frequency estimators considering decaying DC components
    • May
    • M.R.Kun, F. Ling,D.Zhao-Yang,W.K. Po, B. Z.Qian, andX. H. Bo, "Dynamic phasor and frequency estimators considering decaying DC components," IEEE Trans. Power Syst., vol. 27, no. 2, pp. 671-681, May 2012.
    • (2012) IEEE Trans. Power Syst. , vol.27 , Issue.2 , pp. 671-681
    • Kun, M.R.1    Ling, F.2    Zhao-Yang, D.3    Po, W.K.4    Qian, B.Z.5    Bo, X.H.6
  • 2
    • 49249105233 scopus 로고    scopus 로고
    • A novel algorithm for accurate frequency measurement using transformed consecutive points of DFT
    • Aug.
    • Y. Rengang and X. Hui, "A novel algorithm for accurate frequency measurement using transformed consecutive points of DFT," IEEE Trans. Power Syst., vol. 23, no. 3, pp. 1057-1062, Aug. 2008.
    • (2008) IEEE Trans. Power Syst. , vol.23 , Issue.3 , pp. 1057-1062
    • Rengang, Y.1    Hui, X.2
  • 3
    • 84873634473 scopus 로고    scopus 로고
    • Real-time power system phasors and harmonics estimation using a new decoupled recursive-least-squares technique for DSP implementation
    • Jun.
    • I. Sadinezhad and V. Agelidis, "Real-time power system phasors and harmonics estimation using a new decoupled recursive-least-squares technique for DSP implementation," IEEE Trans. Ind. Electron., vol. 60, no. 6, pp. 2295-2308, Jun. 2013.
    • (2013) IEEE Trans. Ind. Electron. , vol.60 , Issue.6 , pp. 2295-2308
    • Sadinezhad, I.1    Agelidis, V.2
  • 4
    • 9244221652 scopus 로고    scopus 로고
    • Estimation of power system parameters
    • Nov.
    • D. Jones, "Estimation of power system parameters," IEEE Trans. Power Syst., vol. 19, no. 4, pp. 1980-1989, Nov. 2004.
    • (2004) IEEE Trans. Power Syst. , vol.19 , Issue.4 , pp. 1980-1989
    • Jones, D.1
  • 5
    • 0027590292 scopus 로고
    • Dynamicmodeling and parameter estimation of a radial and loop type distribution system network
    • May
    • Q. Jun, H. Chen, and A. A. Girgis, "Dynamicmodeling and parameter estimation of a radial and loop type distribution system network," IEEE Trans. Power Syst., vol. 8, no. 2, pp. 483-490, May 1993.
    • (1993) IEEE Trans. Power Syst. , vol.8 , Issue.2 , pp. 483-490
    • Jun, Q.1    Chen, H.2    Girgis, A.A.3
  • 6
    • 79953213707 scopus 로고    scopus 로고
    • Adaptive phasor and frequency-tracking schemes for wide-area protection and control
    • Apr.
    • I. Kamwa, A. K. Pradhan, and G. Joos, "Adaptive phasor and frequency-tracking schemes for wide-area protection and control," IEEE Trans. Power Del., vol. 26, no. 2, pp. 744-753, Apr. 2011.
    • (2011) IEEE Trans. Power Del. , vol.26 , Issue.2 , pp. 744-753
    • Kamwa, I.1    Pradhan, A.K.2    Joos, G.3
  • 7
    • 80054948739 scopus 로고    scopus 로고
    • Instantaneous oscillating phasor estimates with Taylor K-Kalman filters
    • Nov.
    • J. A. de la O Serna and J. Rodriguez-Maldonado, "Instantaneous oscillating phasor estimates with Taylor K-Kalman filters," IEEE Trans. Power Syst., vol. 26, no. 4, pp. 2336-2344, Nov. 2011.
    • (2011) IEEE Trans. Power Syst. , vol.26 , Issue.4 , pp. 2336-2344
    • Serna O De La, J.A.1    Rodriguez-Maldonado, J.2
  • 9
    • 79151470042 scopus 로고    scopus 로고
    • A phasordata-based state estimator incorporating phase bias correction
    • Feb.
    • L. Vanfretti, J. H. Chow, S. Sarawgi, and B. Fardanesh, "A phasordata-based state estimator incorporating phase bias correction," IEEE Trans. Power Syst., vol. 26, no. 1, pp. 111-119, Feb. 2011.
    • (2011) IEEE Trans. Power Syst. , vol.26 , Issue.1 , pp. 111-119
    • Vanfretti, L.1    Chow, J.H.2    Sarawgi, S.3    Fardanesh, B.4
  • 10
    • 79960391878 scopus 로고    scopus 로고
    • Improved method for frequency estimation of sampled sinusoidal signals without iteration
    • Aug.
    • S. Y. Park, Y. S. Song, H. J. Kim, and J. Park, "Improved method for frequency estimation of sampled sinusoidal signals without iteration," IEEE Trans. Instrum. Meas., vol. 60, no. 8, pp. 2828-2834, Aug. 2011.
    • (2011) IEEE Trans. Instrum. Meas. , vol.60 , Issue.8 , pp. 2828-2834
    • Park, S.Y.1    Song, Y.S.2    Kim, H.J.3    Park, J.4
  • 11
    • 80054060625 scopus 로고    scopus 로고
    • Frequency and power components estimation from instantaneous power signal
    • Nov.
    • V. Terzija, D. Cai, V. Stanojevic, and G. Strbac, "Frequency and power components estimation from instantaneous power signal," IEEE Trans. Instrum. Meas., vol. 60, no. 11, pp. 3640-3649, Nov. 2011.
    • (2011) IEEE Trans. Instrum. Meas. , vol.60 , Issue.11 , pp. 3640-3649
    • Terzija, V.1    Cai, D.2    Stanojevic, V.3    Strbac, G.4
  • 12
    • 84863000959 scopus 로고    scopus 로고
    • A hybrid method for power system frequency estimation
    • Mar.
    • J. Ren and M. Kezunovic, "A hybrid method for power system frequency estimation," IEEE Trans. Power Del., vol. 27, no. 3, pp. 1252-1259, Mar. 2012.
    • (2012) IEEE Trans. Power Del. , vol.27 , Issue.3 , pp. 1252-1259
    • Ren, J.1    Kezunovic, M.2
  • 13
    • 84859711061 scopus 로고    scopus 로고
    • Virtual multifunction power quality analyzer based on adaptive linear neural network
    • Aug.
    • I. C. Cheng, "Virtual multifunction power quality analyzer based on adaptive linear neural network," IEEE Trans. Ind. Electron., vol. 59, no. 8, pp. 3321-3329, Aug. 2012.
    • (2012) IEEE Trans. Ind. Electron. , vol.59 , Issue.8 , pp. 3321-3329
    • Cheng, I.C.1
  • 14
    • 0025519493 scopus 로고
    • Harmonic source monitoring and identification using neural networks
    • Nov.
    • R. K. Hartana and G. G. Richards, "Harmonic source monitoring and identification using neural networks," IEEE Trans. Power Syst., vol. 5, no. 4, pp. 1098-1104, Nov. 1990.
    • (1990) IEEE Trans. Power Syst. , vol.5 , Issue.4 , pp. 1098-1104
    • Hartana, R.K.1    Richards, G.G.2
  • 15
    • 84868131401 scopus 로고    scopus 로고
    • Spectral correction approach based on desirable sidelobe window for harmonic analysis of industrial power system
    • Aug.
    • H. Wen, Z. S. Teng, Y. Wang, and X. G. Hu, "Spectral correction approach based on desirable sidelobe window for harmonic analysis of industrial power system," IEEE Trans. Ind. Electron., vol. 60, no. 3, pp. 1001-1010, Aug. 2013.
    • (2013) IEEE Trans. Ind. Electron. , vol.60 , Issue.3 , pp. 1001-1010
    • Wen, H.1    Teng, Z.S.2    Wang, Y.3    Hu, X.G.4
  • 16
    • 84860243490 scopus 로고    scopus 로고
    • A frequency domain approach to characterize and analyze load profiles
    • May
    • Z. Shiyin and K. Tam, "A frequency domain approach to characterize and analyze load profiles," IEEE Trans. Power Syst., vol. 27, no. 2, pp. 857-865, May 2012.
    • (2012) IEEE Trans. Power Syst. , vol.27 , Issue.2 , pp. 857-865
    • Shiyin, Z.1    Tam, K.2
  • 17
    • 0035306423 scopus 로고    scopus 로고
    • The algorithmof interpolating windowed FFT for harmonic analysis of electric power system
    • May
    • Z. Fusheng, G. Zhongxing, and Y.Wei, "The algorithmof interpolating windowed FFT for harmonic analysis of electric power system," IEEE Trans. Power Del., vol. 16, no. 2, pp. 160-164, May 2001.
    • (2001) IEEE Trans. Power Del. , vol.16 , Issue.2 , pp. 160-164
    • Fusheng, Z.1    Zhongxing, G.2    Wei, Y.3
  • 18
    • 77957990788 scopus 로고    scopus 로고
    • Accuracy of sine wave frequency estimation by multipoint interpolated DFT approach
    • Nov.
    • D. Belega, D. Dallet, and D. Petri, "Accuracy of sine wave frequency estimation by multipoint interpolated DFT approach," IEEE Trans. Instrum. Meas., vol. 59, no. 11, pp. 2808-2815, Nov. 2010.
    • (2010) IEEE Trans. Instrum. Meas. , vol.59 , Issue.11 , pp. 2808-2815
    • Belega, D.1    Dallet, D.2    Petri, D.3
  • 19
    • 77951666914 scopus 로고    scopus 로고
    • Single-phase phase anglemeasurements in electric power systems
    • May
    • X. Tao and L.Yilu, "Single-phase phase anglemeasurements in electric power systems," IEEE Trans. Power Syst., vol. 25, no. 2, pp. 844-852, May 2010.
    • (2010) IEEE Trans. Power Syst. , vol.25 , Issue.2 , pp. 844-852
    • Tao, X.1    Yilu, L.2
  • 20
    • 0017851927 scopus 로고
    • On the use of windows for harmonic analysis with the discrete Fourier transform
    • F. J. Harris, "On the use of windows for harmonic analysis with the discrete Fourier transform," Proc. IEEE, vol. 66, no. 1, pp. 51-83, Jan. 1978. (Pubitemid 8338069)
    • (1978) Proceedings of the IEEE , vol.66 , Issue.1 , pp. 51-83
    • Harris, F.J.1
  • 23
    • 34249068840 scopus 로고    scopus 로고
    • Extremely flat-top windows for harmonic analysis
    • DOI 10.1109/TIM.2007.894889, 2006 Advanced Methods for Uncertainty Estimation in Measurement Workshop
    • I. S. Reljin, B. D. Reljin, and V. D. Papic, "Extremely flat-top windows for harmonic analysis," IEEE Trans. Instrum. Meas., vol. 56, no. 3, pp. 1025-1041, Aug. 2007. (Pubitemid 46784575)
    • (2007) IEEE Transactions on Instrumentation and Measurement , vol.56 , Issue.3 , pp. 1025-1041
    • Reljin, I.S.1    Reljin, B.D.2    Papic, V.D.3
  • 24
    • 80053197569 scopus 로고    scopus 로고
    • Simple interpolated FFT algorithm based on minimize sidelobe windows for power-harmonic analysis
    • Sep.
    • H. Wen, Z. S. Teng, Y. Wang, B. Zeng, and X. G. Hu, "Simple interpolated FFT algorithm based on minimize sidelobe windows for power-harmonic analysis," IEEE Trans. Power Electron., vol. 26, no. 9, pp. 2570-2579, Sep. 2011.
    • (2011) IEEE Trans. Power Electron. , vol.26 , Issue.9 , pp. 2570-2579
    • Wen, H.1    Teng, Z.S.2    Wang, Y.3    Zeng, B.4    Hu, X.G.5
  • 25
    • 81855201726 scopus 로고    scopus 로고
    • Statistical description of the sinewave frequency estimator provided by the interpolated DFT method
    • Jan.
    • D. Belega, D. Dallet, and D. Petri, "Statistical description of the sinewave frequency estimator provided by the interpolated DFT method," Measurement, vol. 45, no. 1, pp. 109-117, Jan. 2012.
    • (2012) Measurement , vol.45 , Issue.1 , pp. 109-117
    • Belega, D.1    Dallet, D.2    Petri, D.3
  • 26
    • 0026850997 scopus 로고
    • The influence of windowing on the accuracy of multifrequency signal parameter estimation
    • Feb.
    • C. Offelli and D. Petri, "The influence of windowing on the accuracy of multifrequency signal parameter estimation," IEEE Trans. Instrum. Meas., vol. 41, no. 2, pp. 256-261, Feb. 1992.
    • (1992) IEEE Trans. Instrum. Meas. , vol.41 , Issue.2 , pp. 256-261
    • Offelli, C.1    Petri, D.2
  • 27
    • 37249066119 scopus 로고    scopus 로고
    • Dynamics of frequency estimation in the frequency domain
    • DOI 10.1109/TIM.2007.908240
    • D. Agrez, "Dynamics of frequency estimation in the frequency domain," IEEE Trans. Instrum. Meas., vol. 56, no. 6, pp. 2111-2118, Jun. 2007. (Pubitemid 350268438)
    • (2007) IEEE Transactions on Instrumentation and Measurement , vol.56 , Issue.6 , pp. 2111-2118
    • Agrez, D.1
  • 28
    • 76849094307 scopus 로고    scopus 로고
    • Triangular self-convolution window with desirable sidelobe behaviors for harmonic analysis of power system
    • Mar.
    • H. Wen, Z. S. Teng, and S. Y. Guo, "Triangular self-convolution window with desirable sidelobe behaviors for harmonic analysis of power system," IEEE Trans. Instrum. Meas., vol. 59, no. 3, pp. 543-552, Mar. 2010.
    • (2010) IEEE Trans. Instrum. Meas. , vol.59 , Issue.3 , pp. 543-552
    • Wen, H.1    Teng, Z.S.2    Guo, S.Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.