메뉴 건너뛰기




Volumn 23, Issue 3, 2008, Pages 1057-1062

A novel algorithm for accurate frequency measurement using transformed consecutive points of DFT

Author keywords

Discrete Fourier transform (DFT); Frequency domain analysis; Frequency measurement

Indexed keywords

DISCRETE FOURIER TRANSFORM (DFT); DYNAMIC STATES; FREQUENCY DEVIATIONS; FREQUENCY DOMAIN ANALYSIS; FREQUENCY MEASUREMENT; FREQUENCY MEASUREMENTS; HIGH-PRECISION; INTER-HARMONICS; LEAKAGE COMPONENTS; NOVEL ALGORITHMS; POWER SYSTEM FREQUENCIES; POWER SYSTEMS; SIMULATION EXPERIMENTS; VOLTAGE SIGNALING;

EID: 49249105233     PISSN: 08858950     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRS.2008.922539     Document Type: Article
Times cited : (41)

References (14)
  • 1
    • 0035400257 scopus 로고    scopus 로고
    • A precise calculation of power system frequency
    • Jul
    • J. Z. Yang and C. W. Liu, "A precise calculation of power system frequency," IEEE Trans. Power Del., vol. 16, no. 3, pp. 361-366, Jul. 2001.
    • (2001) IEEE Trans. Power Del , vol.16 , Issue.3 , pp. 361-366
    • Yang, J.Z.1    Liu, C.W.2
  • 2
    • 0027577309 scopus 로고
    • Frequency tracking in power networks in the presence of harmonics
    • Apr
    • M. M. Begovic, P. M. Djunric, S. Dulap, and A. G. Phadke, "Frequency tracking in power networks in the presence of harmonics," IEEE Trans. Power Del., vol. 8, no. 2, pp. 480-486, Apr. 1993.
    • (1993) IEEE Trans. Power Del , vol.8 , Issue.2 , pp. 480-486
    • Begovic, M.M.1    Djunric, P.M.2    Dulap, S.3    Phadke, A.G.4
  • 3
    • 0021479083 scopus 로고
    • A new technique for rapid tracking of frequency deviations based on level crossing
    • Aug
    • C. T. Nguyen and K. Srinivasan, "A new technique for rapid tracking of frequency deviations based on level crossing," IEEE Trans Power App. Syst., vol. PAS-103, no. 8, pp. 2230-2236, Aug. 1984.
    • (1984) IEEE Trans Power App. Syst , vol.PAS-103 , Issue.8 , pp. 2230-2236
    • Nguyen, C.T.1    Srinivasan, K.2
  • 4
    • 0026853731 scopus 로고
    • Fast adaptive schemes for tracking voltage phasor and local frequency in power transmission and distribution systems
    • Apr
    • I. Kamwa and R. Grondin, "Fast adaptive schemes for tracking voltage phasor and local frequency in power transmission and distribution systems," IEEE Trans. Power Del., vol. 7, no. 2, pp. 789-795, Apr. 1992.
    • (1992) IEEE Trans. Power Del , vol.7 , Issue.2 , pp. 789-795
    • Kamwa, I.1    Grondin, R.2
  • 5
    • 0022011618 scopus 로고
    • A least error squares technique for determining power system frequency
    • Feb
    • M. S. Sachdev and M. M. Giray, "A least error squares technique for determining power system frequency," IEEE Trans. Power App. Syst. vol. PAS-104, no. 2, pp. 437-443, Feb. 1985.
    • (1985) IEEE Trans. Power App. Syst , vol.PAS-104 , Issue.2 , pp. 437-443
    • Sachdev, M.S.1    Giray, M.M.2
  • 6
    • 0024704302 scopus 로고
    • Off-nominal frequency measurements in electric power system
    • Jul
    • M. M. Giray and M. S. Sachdev, "Off-nominal frequency measurements in electric power system," IEEE Trans Power Del., vol. 4, no. 3, pp. 1573-1578, Jul. 1989.
    • (1989) IEEE Trans Power Del , vol.4 , Issue.3 , pp. 1573-1578
    • Giray, M.M.1    Sachdev, M.S.2
  • 7
    • 0028462778 scopus 로고
    • Voltage phasor and local system frequency estimation using newton type algorithm
    • Jul
    • V. V. Terzjia, M. B. Djuric, and B. D. Kovacevic, "Voltage phasor and local system frequency estimation using newton type algorithm," IEEE Trans. Power Del., vol. 9, no. 3, pp. 1368-1374, Jul. 1994.
    • (1994) IEEE Trans. Power Del , vol.9 , Issue.3 , pp. 1368-1374
    • Terzjia, V.V.1    Djuric, M.B.2    Kovacevic, B.D.3
  • 8
    • 0022252346 scopus 로고
    • Kalman filtering applied to power system measurement for relaying
    • Dec
    • M. S. Sachdev, H. C. Wood, and N. G. Johnson, "Kalman filtering applied to power system measurement for relaying," IEEE Trans. Power App. Syst., vol. PAS-104, no. 12, pp. 3565-3573, Dec. 1985.
    • (1985) IEEE Trans. Power App. Syst , vol.PAS-104 , Issue.12 , pp. 3565-3573
    • Sachdev, M.S.1    Wood, H.C.2    Johnson, N.G.3
  • 9
    • 0021510454 scopus 로고
    • Optimal estimation of voltage phasors and frequency deviation using linear and nonlinear Kalman filter. Theory and limitations
    • Oct
    • A. A. Girgis and T. L. D. Hwang, "Optimal estimation of voltage phasors and frequency deviation using linear and nonlinear Kalman filter. Theory and limitations," IEEE Trans. Power App. Syst., vol. PAS-103, no. 10, pp. 2943-2949, Oct. 1984.
    • (1984) IEEE Trans. Power App. Syst , vol.PAS-103 , Issue.10 , pp. 2943-2949
    • Girgis, A.A.1    Hwang, T.L.D.2
  • 10
    • 0025411286 scopus 로고
    • Adaptive estimation of power system frequency deviation and its rates of change for calculating sudden power system overloads
    • Apr
    • A. A. Girgis and W. L. Peterson, "Adaptive estimation of power system frequency deviation and its rates of change for calculating sudden power system overloads," IEEE Trans. Power Del., vol. 5, no. 2, pp. 585-594, Apr. 1990.
    • (1990) IEEE Trans. Power Del , vol.5 , Issue.2 , pp. 585-594
    • Girgis, A.A.1    Peterson, W.L.2
  • 11
    • 0031199020 scopus 로고    scopus 로고
    • Real-time determination of power system frequency
    • Aug
    • T. Lobos and J. Rezmer, "Real-time determination of power system frequency," IEEE Trans. Instrum. Meas., vol. 46, no. 4, pp. 877-881, Aug. 1997.
    • (1997) IEEE Trans. Instrum. Meas , vol.46 , Issue.4 , pp. 877-881
    • Lobos, T.1    Rezmer, J.2
  • 12
    • 0020749811 scopus 로고
    • A new measurement technique for tracking voltage phasors, local system frequency, and rate of change of frequency
    • May
    • A. G. Phadke, J. S. Thorp, and M. G. Adamiak, "A new measurement technique for tracking voltage phasors, local system frequency, and rate of change of frequency," IEEE Trans. Power App. Syst., vol. PAS-102, no. 5, pp. 1025-1038, May 1983.
    • (1983) IEEE Trans. Power App. Syst , vol.PAS-102 , Issue.5 , pp. 1025-1038
    • Phadke, A.G.1    Thorp, J.S.2    Adamiak, M.G.3
  • 13
    • 0018907856 scopus 로고
    • A quantitative study of pitfalls in the FFT
    • Jul
    • A. A. Girgis and F. M. Ham, "A quantitative study of pitfalls in the FFT," IEEE Trans. Aerosp. Electron. Syst., vol. AES-16, no. 4, pp. 434-439, Jul. 1980.
    • (1980) IEEE Trans. Aerosp. Electron. Syst , vol.AES-16 , Issue.4 , pp. 434-439
    • Girgis, A.A.1    Ham, F.M.2
  • 14
    • 0035306423 scopus 로고    scopus 로고
    • The algorithm of interpolating windowed FFT for harmonic analysis of electric power system
    • Jan
    • F. S. Zhang, Z. X. Geng, and W. Yuan, "The algorithm of interpolating windowed FFT for harmonic analysis of electric power system," IEEE Trans. Power Del., vol. 16, no. 1, pp. 160-164, Jan. 2001.
    • (2001) IEEE Trans. Power Del , vol.16 , Issue.1 , pp. 160-164
    • Zhang, F.S.1    Geng, Z.X.2    Yuan, W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.