메뉴 건너뛰기




Volumn 38, Issue 4, 2014, Pages 282-289

In vitro evaluation of a novel autologous aortic valve (biovalve) with a pulsatile circulation circuit

Author keywords

Aortic valve; Autologous tissue; Biovalve; Heart valve; Pulsatile circulation circuit; Tissue engineering

Indexed keywords

BLOOD VESSELS; COLLAGEN; DURABILITY; FUNCTION EVALUATION; MOLDS; TIMING CIRCUITS; TISSUE; TISSUE ENGINEERING;

EID: 84897576041     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/aor.12173     Document Type: Article
Times cited : (9)

References (16)
  • 1
    • 77956472975 scopus 로고    scopus 로고
    • Artificial valves "up to date" in Japan
    • Tokunaga S, Tominaga R. Artificial valves "up to date" in Japan. J Artif Organs 2010;13:77-87.
    • (2010) J Artif Organs , vol.13 , pp. 77-87
    • Tokunaga, S.1    Tominaga, R.2
  • 2
    • 33751103663 scopus 로고    scopus 로고
    • Heart valve tissue engineering: concepts, approaches, progress, and challenges
    • Mendelson K, Schoen FJ. Heart valve tissue engineering: concepts, approaches, progress, and challenges. Ann Biomed Eng 2006;34:1799-1819.
    • (2006) Ann Biomed Eng , vol.34 , pp. 1799-1819
    • Mendelson, K.1    Schoen, F.J.2
  • 3
    • 71649090435 scopus 로고    scopus 로고
    • Preparation of a completely autologous trileaflet valve-shaped construct by in-body tissue architecture technology
    • Nakayama Y, Yamanami M, Yahata Y, etal. Preparation of a completely autologous trileaflet valve-shaped construct by in-body tissue architecture technology. J Biomed Mater Res B Appl Biomater 2009;91:813-818.
    • (2009) J Biomed Mater Res B Appl Biomater , vol.91 , pp. 813-818
    • Nakayama, Y.1    Yamanami, M.2    Yahata, Y.3
  • 4
    • 77956467144 scopus 로고    scopus 로고
    • Preparation of in-vivo tissue-engineered valved conduit with the sinus of Valsalva (type IV biovalve)
    • Yamanami M, Yahata Y, Tajikawa T, etal. Preparation of in-vivo tissue-engineered valved conduit with the sinus of Valsalva (type IV biovalve). J Artif Organs 2010;13:106-112.
    • (2010) J Artif Organs , vol.13 , pp. 106-112
    • Yamanami, M.1    Yahata, Y.2    Tajikawa, T.3
  • 5
    • 77956475423 scopus 로고    scopus 로고
    • Development of a completely autologous valved conduit with the sinus of Valsalva using in-body tissue architecture technology: a pilot study in pulmonary valve replacement in a beagle model
    • Yamanami M, Yahata Y, Uechi M, etal. Development of a completely autologous valved conduit with the sinus of Valsalva using in-body tissue architecture technology: a pilot study in pulmonary valve replacement in a beagle model. Circulation 2010;122(11 Suppl.):S100-106.
    • (2010) Circulation , vol.122 , Issue.11 SUPPL.
    • Yamanami, M.1    Yahata, Y.2    Uechi, M.3
  • 6
    • 80052332468 scopus 로고    scopus 로고
    • A completely autologous valved conduit prepared in the open form of trileaflets (type VI biovalve): mold design and valve function in vitro
    • Nakayama Y, Yahata Y, Yamanami M, etal. A completely autologous valved conduit prepared in the open form of trileaflets (type VI biovalve): mold design and valve function in vitro. J Biomed Mater Res B Appl Biomater 2011;99:135-141.
    • (2011) J Biomed Mater Res B Appl Biomater , vol.99 , pp. 135-141
    • Nakayama, Y.1    Yahata, Y.2    Yamanami, M.3
  • 7
    • 84879421204 scopus 로고    scopus 로고
    • In vivo evaluation of an in-body, tissue-engineered, completely autologous valved conduit (biovalve type VI) as an aortic valve in a goat model
    • Takewa Y, Yamanami M, Kishimoto Y, etal. In vivo evaluation of an in-body, tissue-engineered, completely autologous valved conduit (biovalve type VI) as an aortic valve in a goat model. J Artif Organs 2013 16:176-184.
    • (2013) J Artif Organs , vol.16 , pp. 176-184
    • Takewa, Y.1    Yamanami, M.2    Kishimoto, Y.3
  • 8
    • 85081454371 scopus 로고    scopus 로고
    • In vitro and in vivo performance of a completely autologous aortic valved conduit (BIOVALVE Type VII) prepared by in body tissue architecture technology using a novel separable mold
    • Nakayama Y, Takewa Y, Sumikura H, etal. In vitro and in vivo performance of a completely autologous aortic valved conduit (BIOVALVE Type VII) prepared by in body tissue architecture technology using a novel separable mold. Circulation 2012;126:A8910.
    • (2012) Circulation , vol.126
    • Nakayama, Y.1    Takewa, Y.2    Sumikura, H.3
  • 9
    • 84879417983 scopus 로고    scopus 로고
    • Development and evaluation of endurance test system for ventricular assist devices
    • Sumikura H, Homma A, Ohnuma K, etal. Development and evaluation of endurance test system for ventricular assist devices. J Artif Organs 2013 16:138-148.
    • (2013) J Artif Organs , vol.16 , pp. 138-148
    • Sumikura, H.1    Homma, A.2    Ohnuma, K.3
  • 10
    • 84858702495 scopus 로고    scopus 로고
    • Engineering analysis of the effects of bulging sinuses in a newly designed pediatric pulmonary heart valve on hemodynamic function
    • Suzuki I, Shiraishi Y, Yabe S, etal. Engineering analysis of the effects of bulging sinuses in a newly designed pediatric pulmonary heart valve on hemodynamic function. J Artif Organs 2012;15:49-56.
    • (2012) J Artif Organs , vol.15 , pp. 49-56
    • Suzuki, I.1    Shiraishi, Y.2    Yabe, S.3
  • 11
    • 77954956601 scopus 로고    scopus 로고
    • A novel approach to the in vitro hydrodynamic study of the aortic valve: mock loop development and test
    • Vismara R, Fiore GB, Mangini A, etal. A novel approach to the in vitro hydrodynamic study of the aortic valve: mock loop development and test. ASAIO J 2010;56:279-284.
    • (2010) ASAIO J , vol.56 , pp. 279-284
    • Vismara, R.1    Fiore, G.B.2    Mangini, A.3
  • 12
    • 84859586934 scopus 로고    scopus 로고
    • Manufacturing and hydrodynamic assessment of a novel aortic valve made of a new nanocomposite polymer
    • Rahmani B, Tzamtzis S, Ghanbari H, Burriesci G, Seifalian AM. Manufacturing and hydrodynamic assessment of a novel aortic valve made of a new nanocomposite polymer. J Biomech 2012;45:1205-1211.
    • (2012) J Biomech , vol.45 , pp. 1205-1211
    • Rahmani, B.1    Tzamtzis, S.2    Ghanbari, H.3    Burriesci, G.4    Seifalian, A.M.5
  • 15
    • 0034017795 scopus 로고    scopus 로고
    • Effect of the sinus of Valsalva on the closing motion of bileaflet prosthetic heart valves
    • Ohta Y, Kikuta Y, Shimooka T, Mitamura Y, Yuhta T, Dohi T. Effect of the sinus of Valsalva on the closing motion of bileaflet prosthetic heart valves. Artif Organs 2000;24:309-312.
    • (2000) Artif Organs , vol.24 , pp. 309-312
    • Ohta, Y.1    Kikuta, Y.2    Shimooka, T.3    Mitamura, Y.4    Yuhta, T.5    Dohi, T.6
  • 16
    • 70049111015 scopus 로고    scopus 로고
    • In vitro maturation of "biotube" vascular grafts induced by a 2-day pulsatile flow loading
    • Huang H, Zhou YM, Ishibashi-Ueda H, etal. In vitro maturation of "biotube" vascular grafts induced by a 2-day pulsatile flow loading. J Biomed Mater Res B Appl Biomater 2009;91:320-328.
    • (2009) J Biomed Mater Res B Appl Biomater , vol.91 , pp. 320-328
    • Huang, H.1    Zhou, Y.M.2    Ishibashi-Ueda, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.