메뉴 건너뛰기




Volumn 91, Issue 1, 2009, Pages 320-328

In vitro maturation of "biotube" vascular grafts induced by a 2-day pulsatile flow loading

Author keywords

Biotube; In vitro maturation; Pulsatile flow loading; Tissue engineering; Vascular graft

Indexed keywords

B VALUE; BIOTUBE; BODY TISSUES; BURST PRESSURES; CIRCUMFERENTIAL DIRECTION; CIRCUMFERENTIAL STRESS; COLLAGEN FIBER; COLLAGEN STRUCTURE; FEMORAL ARTERY; FUNCTIONAL PROPERTIES; HUMAN ARTERY; HUMAN CORONARY ARTERIES; IN VITRO MATURATION; IN-VITRO; IN-VIVO; NOVEL CONCEPT; REGENERATIVE MEDICINE; SMALL-DIAMETER; VASCULAR GRAFT; VASCULAR GRAFTS; VASCULAR TISSUE; WALL SHEAR STRESS;

EID: 70049111015     PISSN: 15524973     EISSN: 15524981     Source Type: Journal    
DOI: 10.1002/jbm.b.31405     Document Type: Article
Times cited : (11)

References (35)
  • 2
    • 33947504944 scopus 로고    scopus 로고
    • Development of biotube vascular grafts incorporating cuffs for easy implantation
    • DOI 10.1007/s10047-006-0361-0
    • Watanabe T, Kanda K, Ishibashi-Ueda H, Yaku H, Nakayama Y. Development of biotube vascular grafts incorporating cuffs for easy implantation. J Artif Organs 2007;10:10-15. (Pubitemid 46475000)
    • (2007) Journal of Artificial Organs , vol.10 , Issue.1 , pp. 10-15
    • Watanabe, T.1    Kanda, K.2    Ishibashi-Ueda, H.3    Yaku, H.4    Nakayama, Y.5
  • 3
    • 4444245444 scopus 로고    scopus 로고
    • In vivo tissue-engineered small-caliber arterial graft prosthesis consisting of autologous tissue (biotube)
    • Nakayama Y, Ishibashi-Ueda H, Takamizawa K. In vivo tissue-engineered small-caliber arterial graft prosthesis consisting of autologous tissue (biotube). Cell Transplant 2004;13:439-449.
    • (2004) Cell Transplant , vol.13 , pp. 439-449
    • Nakayama, Y.1    Ishibashi-Ueda, H.2    Takamizawa, K.3
  • 5
    • 34250785137 scopus 로고    scopus 로고
    • Development of an in vivo tissue-engineered, autologous heart valve (the biovalve): Preparation of a prototype model
    • DOI 10.1016/j.jtcvs.2007.01.087, PII S002252230700623X
    • Hayashida K, Kanda K, Yaku H, Ando J, Nakayama Y. Development of an in vivo tissue-engineered, autologous heart valve (the biovalve): Preparation of a prototype model. J Thorac Cardiovasc Surg 2007;134:152-159. (Pubitemid 46962064)
    • (2007) Journal of Thoracic and Cardiovascular Surgery , vol.134 , Issue.1 , pp. 152-159
    • Hayashida, K.1    Kanda, K.2    Yaku, H.3    Ando, J.4    Nakayama, Y.5
  • 6
    • 34548572542 scopus 로고    scopus 로고
    • Development of in vivo tissue-engineered autologous tissue-covered stents (biocovered stents)
    • DOI 10.1007/s10047-007-0376-1
    • Nakayama Y, Zhou YM, Ishibashi-Ueda H. Development of in vivo tissue-engineered autologous tissue-covered stents (biocovered stents). J Artif Organs 2007;10:171-176. (Pubitemid 47389643)
    • (2007) Journal of Artificial Organs , vol.10 , Issue.3 , pp. 171-176
    • Nakayama, Y.1    Zhou, Y.-M.2    Ishibashi-Ueda, H.3
  • 7
    • 0014561934 scopus 로고
    • Autogenous grafts made to order
    • Sparks CH. Autogenous grafts made to order. Ann Thorac Surg 1969;8:104-113.
    • (1969) Ann Thorac Surg , vol.8 , pp. 104-113
    • Sparks, C.H.1
  • 8
    • 0031614496 scopus 로고    scopus 로고
    • The ideal small arterial substitute: A search for the Holy Grail?
    • Conte MS. The ideal small arterial substitute: A search for the Holy Grail? FASEB J 1998;12:43-45.
    • (1998) FASEB J , vol.12 , pp. 43-45
    • Conte, M.S.1
  • 9
    • 0033533992 scopus 로고    scopus 로고
    • Novel vascular graft grown within recipient's own peritoneal cavity
    • Campbell JH, Efendy JL, Campbell GR. Novel vascular graft grown within recipient's own peritoneal cavity. Circ Res 1999;85:1173-1178.
    • (1999) Circ Res , vol.85 , pp. 1173-1178
    • Campbell, J.H.1    Efendy, J.L.2    Campbell, G.R.3
  • 10
    • 37249042755 scopus 로고    scopus 로고
    • The recruitment of primitive Lin(-) Sca-1(+), CD34(+), c-kit(+) and CD271(+) cells during the early intraperitoneal foreign body reaction
    • Vranken I, De Visscher G, Lebacq A, Verbeken E, Flameng W. The recruitment of primitive Lin(-) Sca-1(+), CD34(+), c-kit(+) and CD271(+) cells during the early intraperitoneal foreign body reaction. Biomaterials 2008;29:797-808.
    • (2008) Biomaterials , vol.29 , pp. 797-808
    • Vranken, I.1    De Visscher, G.2    Lebacq, A.3    Verbeken, E.4    Flameng, W.5
  • 12
    • 0028796037 scopus 로고
    • A prospective randomized comparison of Dacron and polytetrafluoroethylene aortic bifurcation grafts
    • Friedman SG, Lazzaro RS, Spier LN, Moccio C, Tortolani AJ. A prospective randomized comparison of Dacron and polytetrafluoroethylene aortic bifurcation grafts. Surgery 1995;117:7-10.
    • (1995) Surgery , vol.117 , pp. 7-10
    • Friedman, S.G.1    Lazzaro, R.S.2    Spier, L.N.3    Moccio, C.4    Tortolani, A.J.5
  • 13
    • 0034837690 scopus 로고    scopus 로고
    • Collagen versus gelatin-coated Dacron versus stretch polytetrafluoroethylene in abdominal aortic bifurcation graft surgery: Results of a seven-year prospective, randomized multicenter trial
    • DOI 10.1067/msy.2001.115904
    • Prager M, Polterauer P, Bohmig HJ, Wagner O, Fugl A, Kretschmer G, Plohner M, Nanobashvili J, Huk I. Collagen versus gelatin-coated Dacron versus stretch polytetrafluoroethylene in abdominal aortic bifurcation graft surgery: Results of a seven-year prospective, randomized multicenter trial. Surgery 2001;130:408-414. (Pubitemid 32868449)
    • (2001) Surgery , vol.130 , Issue.3 , pp. 408-414
    • Prager, M.1    Polterauer, P.2    Bohmig, H.-J.3    Wagner, O.4    Fugl, A.5    Kretschmer, G.6    Plohner, M.7    Nanobashvili, J.8    Huk, I.9
  • 14
    • 0026680879 scopus 로고
    • Femoropopliteal reconstruction with knitted, nonvelour Dacron versus expanded polytetrafluoroethylene
    • Pevec WC, Darling RC, L'Italien GJ, Abbott WM. Femoropopliteal reconstruction with knitted, nonvelour Dacron versus expanded polytetrafluoroethylene. J Vasc Surg 1992;16:60-65.
    • (1992) J Vasc Surg , vol.16 , pp. 60-65
    • Pevec, W.C.1    Darling, R.C.2    L'Italien, G.J.3    Abbott, W.M.4
  • 15
    • 0035108808 scopus 로고    scopus 로고
    • Heparin-bonded dacron or polytetrafluoroethylene for femoropopliteal bypass grafting: A multicenter trial
    • DOI 10.1067/mva.2001.113578
    • Devine C, Hons B, McCollum C. Heparin-bonded Dacron or polytetrafluoroethylene for femoropopliteal bypass grafting: A multicenter trial. J Vasc Surg 2001;33:533-539. (Pubitemid 32215603)
    • (2001) Journal of Vascular Surgery , vol.33 , Issue.3 , pp. 533-539
    • Devine, C.1    Hons, B.2    McCollum, C.3
  • 16
    • 0019306348 scopus 로고
    • Compliance: A continuing problem with vascular grafts
    • Kinley CE, Marble AE. Compliance: A continuing problem with vascular grafts. J Cardiovasc Surg 1980;21:163-170.
    • (1980) J Cardiovasc Surg , vol.21 , pp. 163-170
    • Kinley, C.E.1    Marble, A.E.2
  • 17
    • 0023156064 scopus 로고
    • Effect of compliance mismatch on vascular graft patency
    • DOI 10.1067/mva.1987.avs0050376
    • Abbott WM, Megerman J, Hasson JE, L'Italien G, Warnock DF. Effect of compliance mismatch on vascular graft patency. J Vasc Surg 1987;5:376-382. (Pubitemid 17034851)
    • (1987) Journal of Vascular Surgery , vol.5 , Issue.2 , pp. 376-382
    • Abbott, W.M.1    Megerman, J.2    Hasson, J.E.3
  • 18
    • 7344228405 scopus 로고
    • Low compliance and arterial graft occlusion
    • Kidson IG, Abbott WM. Low compliance and arterial graft occlusion. Circulation 1978;58(Suppl):I1-I4.
    • (1978) Circulation , vol.58 , Issue.SUPPL.
    • Kidson, I.G.1    Abbott, W.M.2
  • 19
    • 0030250680 scopus 로고    scopus 로고
    • Computational simulation of flow in the end-to-end anastomosis of a rigid graft and a compliant artery
    • Qiu Y, Tarbell JM. Computational simulation of flow in the end-to-end anastomosis of a rigid graft and a compliant artery. ASAIO J 1996;42:M702-M709. (Pubitemid 26363756)
    • (1996) ASAIO Journal , vol.42 , Issue.5
    • Qiu, Y.1    Tarbell, J.M.2
  • 20
    • 0026832789 scopus 로고
    • Effects of a vascular graft/natural artery compliance mismatch on pulsatile flow
    • Stewart SF, Lyman DJ. Effects of a vascular graft/natural artery compliance mismatch on pulsatile flow. J Biomech 1992;25:297-310.
    • (1992) J Biomech , vol.25 , pp. 297-310
    • Stewart, S.F.1    Lyman, D.J.2
  • 21
    • 0030152429 scopus 로고    scopus 로고
    • Novel compliant and tissue-permeable microporous polyurethane vascular prosthesis fabricated using an excimer laser ablation technique
    • DOI 10.1002/(SICI)1097-4636(199605)31:1<27::AID-JBM4>3.0.CO;2-S
    • Doi K, Nakayama Y, Matsuda T. Novel compliant and tissue-permeable microporous polyurethane vascular prosthesis fabricated using an excimer laser ablation technique. J Biomed Mater Res 1996;31:27-33. (Pubitemid 26125301)
    • (1996) Journal of Biomedical Materials Research , vol.31 , Issue.1 , pp. 27-33
    • Doi, K.1    Nakayama, Y.2    Matsuda, T.3
  • 23
    • 0027376643 scopus 로고
    • Mechanical stress induced cellular orientation and phenotypic modulation of 3-D cultured smooth muscle cells
    • DOI 10.1097/00002480-199307000-00108
    • Kanda K, Matsuda T Oka T. Mechanical stress induced cellular orientation and phenotypic modulation of 3-D cultured smooth muscle cells. ASAIO J 1993;39:M686. (Pubitemid 23311786)
    • (1993) ASAIO Journal , vol.39 , Issue.3
    • Kanda, K.1    Matsuda, T.2    Oka, T.3
  • 24
    • 0032874954 scopus 로고    scopus 로고
    • Cyclic mechanical strain regulates the development of engineered smooth muscle tissue
    • DOI 10.1038/13671
    • Kim BS, Nikolovski J, Bonadio J, Mooney DJ. Cyclic mechanical strain regulates the development of engineered smooth muscle tissue. Nat Biotechnol 1999;17:979-983. (Pubitemid 29474853)
    • (1999) Nature Biotechnology , vol.17 , Issue.10 , pp. 979-983
    • Kim, B.-S.1    Nikolovski, J.2    Bonadio, J.3    Mooney, D.J.4
  • 25
    • 5044226134 scopus 로고    scopus 로고
    • Mechano-active tissue engineering of vascular smooth muscle using pulsatile perfusion bioreactors and elastic PLCL scaffolds
    • DOI 10.1016/j.biomaterials.2004.04.036, PII S0142961204004077
    • Jeong SI, Kwon JH, Lim JI, Cho SW, Jung Y, Sung WJ, Kim SH, Kim YH, Lee YM, Kim BS, Choi CY, Kim SJ. Mechano-active tissue engineering of vascular smooth muscle using pulsatile perfusion bioreactors and elastic PLCL scaffolds. Biomaterials 2005;26:1405-1411. (Pubitemid 39336517)
    • (2005) Biomaterials , vol.26 , Issue.12 , pp. 1405-1411
    • Jeong, S.I.1    Kwon, J.H.2    Lim, J.I.3    Cho, S.-W.4    Jung, Y.5    Sung, W.J.6    Kim, S.H.7    Kim, Y.H.8    Lee, Y.M.9    Kim, B.-S.10    Choi, C.Y.11    Kim, S.-J.12
  • 26
    • 2342529067 scopus 로고    scopus 로고
    • New Multi-cue Bioreactor for Tissue Engineering of Tubular Cardiovascular Samples under Physiological Conditions
    • DOI 10.1089/107632704323061924
    • McCulloch AD, Harris AB, Sarraf CE, Eastwood M. New multi-cue bioreactor for tissue engineering of tubular cardiovascular samples under physiological conditions. Tissue Eng 2004;10:565-573. (Pubitemid 38580277)
    • (2004) Tissue Engineering , vol.10 , Issue.3-4 , pp. 565-573
    • McCulloch, A.D.1    Harris, A.B.2    Sarraf, C.E.3    Eastwood, M.4
  • 27
    • 36849061165 scopus 로고    scopus 로고
    • Bioreactor for application of subatmospheric pressure to three-dimensional cell culture
    • DOI 10.1089/ten.2007.0036
    • Wilkes RP, McNulty AK, Feeley TD, Schmidt MA, Kieswetter K. Bioreactor for application of subatmospheric pressure to three-dimensional cell culture. Tissue Eng 2007;13:3003-3010. (Pubitemid 350233075)
    • (2007) Tissue Engineering , vol.13 , Issue.12 , pp. 3003-3010
    • Wilkes, R.P.1    McNulty, A.K.2    Feeley, T.D.3    Schmidt, M.A.4    Kieswetter, K.5
  • 29
    • 0023157588 scopus 로고
    • Strain energy density function and uniform strain hypothesis for arterial mechanics
    • DOI 10.1016/0021-9290(87)90262-4
    • Takamizawa K, Hayashi K. Stain energy density function and uniform strain hypothesis for arterial mechanics. J Biomech 1987;20:7-17. (Pubitemid 17000562)
    • (1987) Journal of Biomechanics , vol.20 , Issue.1 , pp. 7-17
    • Takamizawa, K.1    Hayashi, K.2
  • 30
    • 0018898430 scopus 로고
    • Stiffness and elastic behavior of human intracranial and extracranial arteries
    • DOI 10.1016/0021-9290(80)90191-8
    • Hayashi K, Handa H, Nagasawa S, Okumura A, Moritake K. Stiffness and elastic behavior of human intercranial and extracranial arteries. J Biomech 1980;13:175-184. (Pubitemid 10176474)
    • (1980) Journal of Biomechanics , vol.13 , Issue.2 , pp. 175-184
    • Hayashi, K.1    Handa, H.2    Nagasawa, S.3
  • 32
    • 0006410113 scopus 로고
    • Mechanical properties and hemodynamics in coronary arteries
    • Kitamura K, Abe H, Sagawa K, editors. Tokyo: Japan Scientific Societies Press
    • Hayashi K, Igarashi Y, Takamizawa K, Mechanical properties and hemodynamics in coronary arteries. In: Kitamura K, Abe H, Sagawa K, editors. New Approaches in Cardiac Mechanics. Tokyo: Japan Scientific Societies Press; 1986. pp 258-294.
    • (1986) New Approaches in Cardiac Mechanics , pp. 258-294
    • Hayashi, K.1    Igarashi, Y.2    Takamizawa, K.3
  • 34
    • 34948849851 scopus 로고    scopus 로고
    • Tissue-engineered blood vessel for adult arterial revascularization [10]
    • DOI 10.1056/NEJMc071536
    • L'Heureux N, McAllister TN, de la Fuente LM. Tissue-engineered blood vessel for adult arterial revascularization. N Engl J Med 2007;4:1451-1453. (Pubitemid 47535609)
    • (2007) New England Journal of Medicine , vol.357 , Issue.14 , pp. 1451-1453
    • L'Heureux, N.1    McAllister, T.N.2    De La Fuente, L.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.