메뉴 건너뛰기




Volumn 112, Issue , 2014, Pages 37-47

Future template numerical interpretation techniques for PD pulse location in transformer windings

Author keywords

Condition monitoring; Hypothesis test; Partial discharge location; Statistical methods; Transformers

Indexed keywords

CONDITION MONITORING; ELECTRIC TRANSFORMER TESTING; ELECTRIC TRANSFORMERS; PARTIAL DISCHARGES; STATISTICAL METHODS; TRANSFORMER WINDINGS;

EID: 84897398494     PISSN: 03787796     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.epsr.2014.02.030     Document Type: Article
Times cited : (10)

References (28)
  • 5
    • 84876137493 scopus 로고    scopus 로고
    • Partial discharge location using a hybrid transformer winding model with morphology-based noise removal, Science Direct
    • T.Y. Ji, W.H. Tang, and Q.H. Wu Partial discharge location using a hybrid transformer winding model with morphology-based noise removal, Science Direct Electr. Power Syst. Res. 101 2013 9 16
    • (2013) Electr. Power Syst. Res. , vol.101 , pp. 9-16
    • Ji, T.Y.1    Tang, W.H.2    Wu, Q.H.3
  • 8
    • 70249145136 scopus 로고    scopus 로고
    • Frequency domain correlation techniques for PD location in transformer windings
    • V. Jeyabalan, and S. Usa Frequency domain correlation techniques for PD location in transformer windings IEEE Trans. Dielectr. Electr. Insul. 16 4 2009 1160 1167
    • (2009) IEEE Trans. Dielectr. Electr. Insul. , vol.16 , Issue.4 , pp. 1160-1167
    • Jeyabalan, V.1    Usa, S.2
  • 9
    • 0242468131 scopus 로고    scopus 로고
    • The application of matched filters to PD detection and localization
    • J. Veen, and M. Van der Wielen The application of matched filters to PD detection and localization IEEE Electr. Insul. Mag. 19 5 2003 20 26
    • (2003) IEEE Electr. Insul. Mag. , vol.19 , Issue.5 , pp. 20-26
    • Veen, J.1    Van Der Wielen, M.2
  • 11
    • 33244493940 scopus 로고    scopus 로고
    • A correlation method for detection of partial discharges in transformers
    • DOI 10.1109/TPWRD.2005.852340
    • S. Jayalalitha, and V. Jayashankar A correlation method for detection of partial discharges in transformers IEEE Trans. Power Deliv. 21 1 2006 531 532 (Pubitemid 43279852)
    • (2006) IEEE Transactions on Power Delivery , vol.21 , Issue.1 , pp. 531-532
    • Jayalalitha, S.1    Jayashankar, V.2
  • 12
    • 37249042043 scopus 로고    scopus 로고
    • Virtual instrument for lightning impulse test
    • A. Palani, and V. Jayashankar Virtual instrument for lightning impulse test IEEE Trans. Power Deliv. 22 3 2007 1309 1317
    • (2007) IEEE Trans. Power Deliv. , vol.22 , Issue.3 , pp. 1309-1317
    • Palani, A.1    Jayashankar, V.2
  • 19
    • 0033148863 scopus 로고    scopus 로고
    • Nonlinear matched filters for differences analysis
    • I. Yan Nonlinear matched filters for differences analysis Radio Electron. Commun. Syst. 46 6 1999 51 54
    • (1999) Radio Electron. Commun. Syst. , vol.46 , Issue.6 , pp. 51-54
    • Yan, I.1
  • 20
    • 42449151862 scopus 로고    scopus 로고
    • Normalization of a reference signal with constant quantization step
    • A.D. Melnyk, and A.I. Rybin Normalization of a reference signal with constant quantization step Radio Electron. Commun. Syst. 51 3 2008 173 175
    • (2008) Radio Electron. Commun. Syst. , vol.51 , Issue.3 , pp. 173-175
    • Melnyk, A.D.1    Rybin, A.I.2
  • 25
    • 79959768116 scopus 로고    scopus 로고
    • Statistical techniques for partial-discharge location in transformer windings
    • V. Jeyabalan, and S. Usa Statistical techniques for partial-discharge location in transformer windings IEEE Trans. Power Deliv. 26 3 2011 2064 2065
    • (2011) IEEE Trans. Power Deliv. , vol.26 , Issue.3 , pp. 2064-2065
    • Jeyabalan, V.1    Usa, S.2
  • 26
    • 50249181070 scopus 로고    scopus 로고
    • Application of numerical evaluation techniques for interpreting frequency responses measurements in power transformers
    • P.M. Nirgude, D. Ashokraju, A.D. Rajkumar, and B.P. Singh Application of numerical evaluation techniques for interpreting frequency responses measurements in power transformers IEE Proc. Sci. Meas. Technol. 2 5 2007 275 285
    • (2007) IEE Proc. Sci. Meas. Technol. , vol.2 , Issue.5 , pp. 275-285
    • Nirgude, P.M.1    Ashokraju, D.2    Rajkumar, A.D.3    Singh, B.P.4
  • 27
    • 12544255076 scopus 로고    scopus 로고
    • Fault diagnosis of a power transformer using an improved frequency-response analysis
    • DOI 10.1109/TPWRD.2004.835428
    • J. Kim, B. Park, S.C. Jeong, S.W. Kim, and P.G. Park Fault diagnosis of a power transformer using an improved frequency-response analysis IEEE Trans. Power Deliv. 20 1 2005 169 178 (Pubitemid 40152047)
    • (2005) IEEE Transactions on Power Delivery , vol.20 , Issue.1 , pp. 169-178
    • Kim, J.-W.1    Park, B.K.2    Jeong, S.C.3    Kim, S.W.4    Park, P.G.5
  • 28
    • 40849097595 scopus 로고    scopus 로고
    • Sweep frequency response analysis (SFRA) for the assessment of winding displacements and deformation in power transformers
    • DOI 10.1016/j.epsr.2007.08.005, PII S037877960700171X
    • J.R. Secue, and E. Mombello Sweep frequency response analysis (SFRA) for the assessment of winding displacements and deformation in power transformers, Science Direct Electr. Power Syst. Res. 78 2008 1119 1128 (Pubitemid 351400335)
    • (2008) Electric Power Systems Research , vol.78 , Issue.6 , pp. 1119-1128
    • Secue, J.R.1    Mombello, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.