메뉴 건너뛰기




Volumn , Issue , 2011, Pages 196-200

Locating partial discharge sources in high voltage transformer windings

Author keywords

condition monitoring; partial discharge; transformer

Indexed keywords

BUSHING TAP; DISCHARGE CURRENTS; EARTH CONNECTION; HIGH VOLTAGE; HIGH VOLTAGE TRANSFORMERS; MEASUREMENT POINTS; ONLINE CONDITION MONITORING; PARTIAL DISCHARGE MEASUREMENTS; PARTIAL DISCHARGE SOURCES; PD MEASUREMENTS; RADIO FREQUENCY CURRENT TRANSDUCER; SIMULATION DATA; SOURCE LOCATION; TRANSFORMER; UNKNOWN COEFFICIENTS;

EID: 80052737723     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/EIC.2011.5996145     Document Type: Conference Paper
Times cited : (10)

References (10)
  • 1
    • 0036880503 scopus 로고    scopus 로고
    • Review of condition assessment of power transformers in service
    • December
    • M Wang, A Vandermaar and K Srivastava 'Review of Condition Assessment of Power Transformers in Service,' in IEEE Electrical Insulation Magazine, 18(6), pp12-25, December 2002.
    • (2002) IEEE Electrical Insulation Magazine , vol.18 , Issue.6 , pp. 12-25
    • Wang, M.1    Vandermaar, A.2    Srivastava, K.3
  • 2
    • 0030193908 scopus 로고    scopus 로고
    • Status and trends in transformer monitoring'
    • July
    • C Bengstsson 'Status and Trends in Transformer Monitoring' IEEE Transactions on Power Delivery, 11(3), pp1379-1384, July 1996.
    • (1996) IEEE Transactions on Power Delivery , vol.11 , Issue.3 , pp. 1379-1384
    • Bengstsson, C.1
  • 3
    • 0344465271 scopus 로고    scopus 로고
    • Review of modern diagnostic techniques for assessing insulation condition in aged transformers'
    • October
    • T K Saha 'Review of Modern Diagnostic Techniques for Assessing Insulation Condition in Aged Transformers' IEEE Transactions on Dielectrics and Electrical Insulation, 10(5), pp903-917, October 2003.
    • (2003) IEEE Transactions on Dielectrics and Electrical Insulation , vol.10 , Issue.5 , pp. 903-917
    • Saha, T.K.1
  • 5
    • 70449638136 scopus 로고    scopus 로고
    • Partial discharge location in high voltage transformers
    • Montreal, QC, Canada, 31 May-3 June
    • R Mohamed and P L Lewin 'Partial Discharge Location in High Voltage Transformers' 2009 IEEE Electrical Insulation Conference, Montreal, QC, Canada, 31 May-3 June 2009, pp200-204
    • (2009) 2009 IEEE Electrical Insulation Conference , pp. 200-204
    • Mohamed, R.1    Lewin, P.L.2
  • 6
    • 17644409075 scopus 로고    scopus 로고
    • Partial Discharge Monitoring of Power Transformers using UHF Sensors. Part 2: Field Experience'
    • June
    • M Judd, L Yang and I Hunter, 'Partial Discharge Monitoring of Power Transformers using UHF Sensors. Part 2: Field Experience' IEEE Electrical Insulation Magazine, 21(3), pp5-13, June 2005
    • (2005) IEEE Electrical Insulation Magazine , vol.21 , Issue.3 , pp. 5-13
    • Judd, M.1    Yang, L.2    Hunter, I.3
  • 10
    • 0024717933 scopus 로고
    • Application of digital filtering techniques to determination of partial discharge location in transformers
    • August
    • R E James, B T Phung and Q Su 'Application of Digital Filtering Techniques to Determination of Partial Discharge Location in Transformers', IEEE Transactions on Dielectrics and Electrical Insulation, 24(4), pp657-668, August 1989
    • (1989) IEEE Transactions on Dielectrics and Electrical Insulation , vol.24 , Issue.4 , pp. 657-668
    • James, R.E.1    Phung, B.T.2    Su, Q.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.