메뉴 건너뛰기




Volumn 23, Issue 4, 2013, Pages 437-441

Comparison of therapeutic outcomes of periprosthetic femoral fracture between treatments employing locking and conventional plates

Author keywords

Conventional plate; Locking plate; Periprosthetic femoral fracture; Vancouver classification

Indexed keywords

ADULT; AGED; ARTICLE; BONE RADIOGRAPHY; CLINICAL ARTICLE; COMPARATIVE STUDY; CONTROLLED STUDY; DALL MILES PLATE SYSTEM; FEMALE; FEMUR FRACTURE; FOLLOW UP; FRACTURE NONUNION; HUMAN; INTERMETHOD COMPARISON; LOCKING COMPRESSION PLATE; MALE; MERLE D AUBIGNE HIP SCORE; MIDDLE AGED; OPERATION DURATION; OPERATIVE BLOOD LOSS; OSTEOSYNTHESIS; OSTEOSYNTHESIS MATERIAL; OUTCOME ASSESSMENT; PERIPROSTHETIC FRACTURE; POSTEL HIP SCORE; PRIORITY JOURNAL; RANGE OF MOTION; SCORING SYSTEM; VERY ELDERLY; WALKING; BONE PLATE; CONVALESCENCE; EQUIPMENT; FRACTURE HEALING; FRAGILITY FRACTURE; HIP ARTHROPLASTY; JAPAN; MATERIALS TESTING; METHODOLOGY; PATHOPHYSIOLOGY; POSTOPERATIVE COMPLICATION; RADIOGRAPHY; RETROSPECTIVE STUDY; STANDARD; TREATMENT OUTCOME; WEIGHT BEARING; OSTEOPOROTIC FRACTURES; PERIPROSTHETIC FRACTURES; POSTOPERATIVE COMPLICATIONS; PROCEDURES;

EID: 84897118132     PISSN: 16338065     EISSN: 14321068     Source Type: Journal    
DOI: 10.1007/s00590-012-1005-0     Document Type: Article
Times cited : (9)

References (18)
  • 1
    • 1642504433 scopus 로고    scopus 로고
    • Aspects of current management. The management of periprosthetic fractures around the femoral stem
    • Learmonth ID (2004) Aspects of current management. The management of periprosthetic fractures around the femoral stem. J Bone Joint Surg Br 86:13-19
    • (2004) J Bone Joint Surg Br , vol.86 , pp. 13-19
    • Learmonth, I.D.1
  • 3
    • 0026715865 scopus 로고
    • Femoral fracture associated with total hip arthroplasty
    • Kavanagh BF (1992) Femoral fracture associated with total hip arthroplasty. Orthop Clin North Am 23:249-257
    • (1992) Orthop Clin North Am , vol.23 , pp. 249-257
    • Kavanagh, B.F.1
  • 4
    • 0037852062 scopus 로고    scopus 로고
    • Principle of management and results of treating the fractured femur during and after total hip arthroplasty
    • Greidanus NV, Mitchell PA, Masri BA et al (2003) Principle of management and results of treating the fractured femur during and after total hip arthroplasty. AAOS instructional course lecture 52:309-322
    • (2003) AAOS Instructional Course Lecture , vol.52 , pp. 309-322
    • Greidanus, N.V.1    Mitchell, P.A.2    Masri, B.A.3
  • 5
    • 34848841807 scopus 로고    scopus 로고
    • Periprosthetic fractures of the femur after hip arthroplasty: An analysis of 99 patients
    • Holley K, Zelken J, Padgett D et al (2007) Periprosthetic fractures of the femur after hip arthroplasty: an analysis of 99 patients. HSS J 3:190-197
    • (2007) HSS J , vol.3 , pp. 190-197
    • Holley, K.1    Zelken, J.2    Padgett, D.3
  • 6
    • 0142138198 scopus 로고    scopus 로고
    • Guidelines for the clinical application of the LCP
    • Gautier E, Sommer C (2003) Guidelines for the clinical application of the LCP. Injury 34:63-76
    • (2003) Injury , vol.34 , pp. 63-76
    • Gautier, E.1    Sommer, C.2
  • 7
    • 84856352955 scopus 로고    scopus 로고
    • Locking compression plates for the treatment of periprosthetic femoral fractures around well-fixed total hip and knee implants
    • Wood GC, Naudie DR, Mcauley J, McCalden RW (2011) Locking compression plates for the treatment of periprosthetic femoral fractures around well-fixed total hip and knee implants. J Arthroplasty 26:886-892
    • (2011) J Arthroplasty , vol.26 , pp. 886-892
    • Wood, G.C.1    Naudie, D.R.2    Mcauley, J.3    McCalden, R.W.4
  • 8
    • 70349416446 scopus 로고    scopus 로고
    • Isolated locked compression plating for Vancouver type B1 periprosthetic femoral fracture
    • Ginger KB, Saam M, Julie AM et al (2009) Isolated locked compression plating for Vancouver type B1 periprosthetic femoral fracture. Injury 40:1180-1186
    • (2009) Injury , vol.40 , pp. 1180-1186
    • Ginger, K.B.1    Saam, M.2    Julie, A.M.3
  • 10
    • 33645666369 scopus 로고    scopus 로고
    • Failure of LCP condylar plate fixation in distal part of the femur. A report of six cases
    • Vallier HA, Hennessey TA, Sontich JK et al (2006) Failure of LCP condylar plate fixation in distal part of the femur. A report of six cases. J Bone Joint Surg Am 88:846-853
    • (2006) J Bone Joint Surg Am , vol.88 , pp. 846-853
    • Vallier, H.A.1    Hennessey, T.A.2    Sontich, J.K.3
  • 11
    • 0029187931 scopus 로고
    • Fracture of the femur after hip replacement
    • Duncan CP, Masri BA (1995) Fracture of the femur after hip replacement. Instr Course Lect 44:293-304
    • (1995) Instr Course Lect , vol.44 , pp. 293-304
    • Duncan, C.P.1    Masri, B.A.2
  • 12
    • 77049159486 scopus 로고
    • Functional result of hip arthroplasty with acrylic prosthesis
    • d'Aubigné RM, Postel M (1954) Functional result of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am 36:451-475
    • (1954) J Bone Joint Surg Am , vol.36 , pp. 451-475
    • D'Aubigné, R.M.1    Postel, M.2
  • 13
    • 0036183538 scopus 로고    scopus 로고
    • The Mennen femoral plate for fixation of periprosthetic femoral fractures following hip arthroplasty
    • PII S0020138301001127
    • Ahuja S, Chatterji S (2002) The Mennen femoral plate for fixation of periprosthetic femoral fractures following hip arthroplasty. Injury 33:47-50 (Pubitemid 34173661)
    • (2002) Injury , vol.33 , Issue.1 , pp. 47-50
    • Ahuja, S.1    Chatterji, S.2
  • 14
    • 0024346439 scopus 로고
    • Treatment of proximal femur fractures associated with total hip arthroplasty
    • Montijo H, Ebert FR, Lennox DA (1989) Treatment of proximal femur fractures associated with total hip arthroplasty. J Arthroplasty 4:115-123
    • (1989) J Arthroplasty , vol.4 , pp. 115-123
    • Montijo, H.1    Ebert, F.R.2    Lennox, D.A.3
  • 15
    • 12244268605 scopus 로고    scopus 로고
    • Dall-Miles plates for periprosthetic femoral fractures: A critical review of 16 cases
    • DOI 10.1016/S0020-1383(02)00161-4, PII S0020138302001614
    • Tsiridis E, Haddad FS, Gie GA (2003) Dall-Miles plates for periprosthetic femoral fractures A critical review of 16 cases. Injury 34:107-110 (Pubitemid 36143631)
    • (2003) Injury , vol.34 , Issue.2 , pp. 107-110
    • Tsiridis, E.1    Haddad, F.S.2    Gie, G.A.3
  • 16
    • 26044432463 scopus 로고    scopus 로고
    • Indirect reduction and plate fixation, without grafting, for periprosthetic femoral shaft fractures about a stable intramedullary implant
    • DOI 10.2106/JBJS.D.01911
    • Ricci WM, Bolhofner BR, Loftus T et al (2005) Indirect reduction and plate fixation, without grafting, for periprosthetic femoral shaft fractures about a stable intramedullary implant. J Bone Joint Surg Am 87:2240-2245 (Pubitemid 41407549)
    • (2005) Journal of Bone and Joint Surgery - Series A , vol.87 , Issue.10 , pp. 2240-2245
    • Ricci, W.M.1    Bolhofner, B.R.2    Loftus, T.3    Cox, C.4    Mitchell, S.5    Borrelli Jr., J.6
  • 17
    • 34248167043 scopus 로고    scopus 로고
    • Locking plate osteosynthesis for Vancouver Type B1 and Type C periprosthetic fractures of femur: A report on 12 patients
    • DOI 10.1016/j.injury.2007.02.038, PII S0020138307000897, Periprosthetic Femoral Fractures
    • Chakravarthy J, Bansal R, Cooper J (2007) Locking plate osteosynthesis for Vancouver type B1 and type C periprosthetic fractures of femur: a report on 12 patients. Injury 38:725-733 (Pubitemid 46726310)
    • (2007) Injury , vol.38 , Issue.6 , pp. 725-733
    • Chakravarthy, J.1    Bansal, R.2    Cooper, J.3
  • 18
    • 34447344840 scopus 로고    scopus 로고
    • Management of periprosthetic femur fractures with a first generation locking plate
    • DOI 10.1016/j.injury.2007.02.026, PII S0020138307000691
    • Fulkerson E, Tejwani N, Stuchin S et al (2007) Management of periprosthetic femur fractures with a first generation locking plate. Injury 38:965-972 (Pubitemid 47058490)
    • (2007) Injury , vol.38 , Issue.8 , pp. 965-972
    • Fulkerson, E.1    Tejwani, N.2    Stuchin, S.3    Egol, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.