메뉴 건너뛰기




Volumn 26, Issue 6, 2011, Pages 886-892

Locking Compression Plates for the Treatment of Periprosthetic Femoral Fractures Around Well-Fixed Total Hip and Knee Implants

Author keywords

Fracture; Locking plates; Periprosthetic; Total hip arthroplasty; Total knee arthroplasty

Indexed keywords

ADULT; AGED; ARTICLE; BONE GRAFT; BONE PLATE; BONE SCREW; CLINICAL ARTICLE; CORTICAL BONE; FEMALE; FEMUR FRACTURE; HUMAN; INTRAOPERATIVE PERIOD; KNEE PROSTHESIS; KNEE RADIOGRAPHY; MALE; MOBILIZATION; SOFT TISSUE; TOTAL HIP PROSTHESIS; TOTAL KNEE REPLACEMENT; BONE TRANSPLANTATION; COHORT ANALYSIS; HIP ARTHROPLASTY; HIP PROSTHESIS; INSTRUMENTATION; KNEE ARTHROPLASTY; METHODOLOGY; MIDDLE AGED; ORTHOPEDIC SURGERY; OSTEOSYNTHESIS; PERIPROSTHETIC FRACTURE; RADIOGRAPHY; REOPERATION; RETROSPECTIVE STUDY; TREATMENT OUTCOME;

EID: 84856352955     PISSN: 08835403     EISSN: 15328406     Source Type: Journal    
DOI: 10.1016/j.arth.2010.07.002     Document Type: Article
Times cited : (33)

References (17)
  • 1
    • 0033839125 scopus 로고    scopus 로고
    • Percutaneous plate fixation for periprosthetic femoral fractures-a preliminary report
    • Abhaykumar S., Elliott D.S. Percutaneous plate fixation for periprosthetic femoral fractures-a preliminary report. Injury 2000, 3:627.
    • (2000) Injury , vol.3 , pp. 627
    • Abhaykumar, S.1    Elliott, D.S.2
  • 2
    • 0032773191 scopus 로고    scopus 로고
    • Nonunion after periprosthetic femoral fracture associated with total hip arthroplasty
    • Crockarell J.R., Berry D.J., Lewallen D.G. Nonunion after periprosthetic femoral fracture associated with total hip arthroplasty. J Bone Joint Surg Am 1999, 81:1073.
    • (1999) J Bone Joint Surg Am , vol.81 , pp. 1073
    • Crockarell, J.R.1    Berry, D.J.2    Lewallen, D.G.3
  • 3
    • 0034049783 scopus 로고    scopus 로고
    • Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem: a biomechanical study of 5 techniques
    • Dennis M.G., Simon J.A., Kummer F.J., et al. Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem: a biomechanical study of 5 techniques. J Arthroplasty 2000, 15:523.
    • (2000) J Arthroplasty , vol.15 , pp. 523
    • Dennis, M.G.1    Simon, J.A.2    Kummer, F.J.3
  • 4
    • 0142138198 scopus 로고    scopus 로고
    • Guidelines for the clinical application of the LCP
    • Gautier E., Sommer C. Guidelines for the clinical application of the LCP. Injury 2003, 34:B63.
    • (2003) Injury , vol.34
    • Gautier, E.1    Sommer, C.2
  • 5
    • 0242657313 scopus 로고    scopus 로고
    • Development of the locking compression plate
    • Frigg R. Development of the locking compression plate. Injury 2003, 34(suppl 2):6.
    • (2003) Injury , vol.34 , Issue.SUPPL. 2 , pp. 6
    • Frigg, R.1
  • 6
    • 33645666369 scopus 로고    scopus 로고
    • Failure of LCP condylar plate fixation in the distal part of the femur. A report of six cases
    • Vallier H.A., Hennessey T.A., Sontich J.K., et al. Failure of LCP condylar plate fixation in the distal part of the femur. A report of six cases. J Bone Joint Surg Am 2006, 88:853.
    • (2006) J Bone Joint Surg Am , vol.88 , pp. 853
    • Vallier, H.A.1    Hennessey, T.A.2    Sontich, J.K.3
  • 7
    • 0142230911 scopus 로고    scopus 로고
    • First clinical results of the locking compression plate (LCP)
    • Sommer C., Gautier E., Muller M., et al. First clinical results of the locking compression plate (LCP). Injury 2003, 34(suppl 2):B43.
    • (2003) Injury , vol.34 , Issue.SUPPL. 2
    • Sommer, C.1    Gautier, E.2    Muller, M.3
  • 8
    • 35448972107 scopus 로고    scopus 로고
    • Locking compression plate fixation of Vancouver type-B1 periprosthetic femoral fractures
    • Buttaro M.A., Farfalli G., Paredes Nunez M., et al. Locking compression plate fixation of Vancouver type-B1 periprosthetic femoral fractures. J Bone Joint Surg Am 2007, 89:1964.
    • (2007) J Bone Joint Surg Am , vol.89 , pp. 1964
    • Buttaro, M.A.1    Farfalli, G.2    Paredes Nunez, M.3
  • 10
    • 0142168925 scopus 로고    scopus 로고
    • Biomechanical testing of the LCP-how can stability in locked internal fixators be controlled?
    • Stoffel K., Dieter U., Stachowiak G., et al. Biomechanical testing of the LCP-how can stability in locked internal fixators be controlled?. Injury 2003, 34(suppl 2):B11.
    • (2003) Injury , vol.34 , Issue.SUPPL. 2
    • Stoffel, K.1    Dieter, U.2    Stachowiak, G.3
  • 11
    • 34248167043 scopus 로고    scopus 로고
    • Locking plate osteosynthesis for Vancouver Type B1 and Type C periprosthetic fractures of the femur: a report on 12 patients
    • Chakravarthy J., Bansal R., Cooper J. Locking plate osteosynthesis for Vancouver Type B1 and Type C periprosthetic fractures of the femur: a report on 12 patients. Injury 2007, 38:725.
    • (2007) Injury , vol.38 , pp. 725
    • Chakravarthy, J.1    Bansal, R.2    Cooper, J.3
  • 12
    • 33646477698 scopus 로고    scopus 로고
    • Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques
    • Fulkerson E., Egol K.A., Kubiak E.N., et al. Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques. J Trauma 2006, 60:830.
    • (2006) J Trauma , vol.60 , pp. 830
    • Fulkerson, E.1    Egol, K.A.2    Kubiak, E.N.3
  • 13
    • 33744503191 scopus 로고    scopus 로고
    • Fixation of periprosthetic femoral shaft fractures associated with cemented femoral stems: a biomechanical comparison of locked plating and conventional cable plates
    • Fulkerson E., Koval K., Preston C.F., et al. Fixation of periprosthetic femoral shaft fractures associated with cemented femoral stems: a biomechanical comparison of locked plating and conventional cable plates. J Orthop Trauma 2006, 20:89.
    • (2006) J Orthop Trauma , vol.20 , pp. 89
    • Fulkerson, E.1    Koval, K.2    Preston, C.F.3
  • 14
    • 27744465990 scopus 로고    scopus 로고
    • The mechanical behavior of locking compression plates compared with dynamic compression plates in a cadaver radius model
    • Gardner M.J., Brophy R.H., Campbell D., et al. The mechanical behavior of locking compression plates compared with dynamic compression plates in a cadaver radius model. J Orthop Trauma 2005, 19:597.
    • (2005) J Orthop Trauma , vol.19 , pp. 597
    • Gardner, M.J.1    Brophy, R.H.2    Campbell, D.3
  • 15
    • 0036600202 scopus 로고    scopus 로고
    • Periprosthetic femoral fractures around well-fixed implants: use of cortical onlay allografts with or without a plate
    • Haddad F.S., Duncan C.P., Berry D.J., et al. Periprosthetic femoral fractures around well-fixed implants: use of cortical onlay allografts with or without a plate. J Bone Joint Surg Am 2002, 84:945.
    • (2002) J Bone Joint Surg Am , vol.84 , pp. 945
    • Haddad, F.S.1    Duncan, C.P.2    Berry, D.J.3
  • 16
    • 70349416446 scopus 로고    scopus 로고
    • Isolated locked compression plating for Vancouver Type B1 periprosthetic femoral fractures
    • Bryant G.K., Morshed S., Agel J., et al. Isolated locked compression plating for Vancouver Type B1 periprosthetic femoral fractures. Injury 2009, 40:1180.
    • (2009) Injury , vol.40 , pp. 1180
    • Bryant, G.K.1    Morshed, S.2    Agel, J.3
  • 17
    • 33646843548 scopus 로고    scopus 로고
    • Locked plates combined with minimally invasive insertion technique for the treatment of periprosthetic supracondylar femur fractures above a total knee arthroplasty
    • Ricci W.M., Loftus T., Cox C., et al. Locked plates combined with minimally invasive insertion technique for the treatment of periprosthetic supracondylar femur fractures above a total knee arthroplasty. J Orthop Trauma 2006, 20:190.
    • (2006) J Orthop Trauma , vol.20 , pp. 190
    • Ricci, W.M.1    Loftus, T.2    Cox, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.