Volumn 85, Issue 4, 2014, Pages 332-338

Quantitative absorption cytometry for measuring red blood cell hemoglobin mass and volume

Author keywords

Cell volume; Hemoglobin mass; Microfluidics; Quantitative absorption cytometry; Red blood cells

Indexed keywords

HEMOGLOBIN;

EID: 84897113255     PISSN: 15524922     EISSN: 15524930     Source Type: Journal    
DOI: 10.1002/cyto.a.22450     Document Type: Article
Times cited : (41)

References (26)
  • 2
    • 78650531287 scopus 로고    scopus 로고
    • Physiological and pathological population dynamics of circulating human red blood cells
    • Higgins JM, Mahadevan L. Physiological and pathological population dynamics of circulating human red blood cells. Proc Natl Acad Sci USA 2010;107:20587-20592.
    • (2010) Proc Natl Acad Sci USA , vol.107 , pp. 20587-20592
    • Higgins, J.M.1    Mahadevan, L.2
  • 3
    • 84975646227 scopus 로고
    • Flow-cytometric light scattering measurement of red blood cell volume and hemoglobin concentration
    • Tycko DH, Metz MH, Epstein EA, Grinbaum A. Flow-cytometric light scattering measurement of red blood cell volume and hemoglobin concentration. App Opt 1985;24:1355-1365.
    • (1985) App Opt , vol.24 , pp. 1355-1365
    • Tycko, D.H.1    Metz, M.H.2    Epstein, E.A.3    Grinbaum, A.4
  • 5
    • 53049110086 scopus 로고    scopus 로고
    • Comparative study of human erythrocytes by digital holographic microscopy, confocal microscopy, and impedence volume analyzer
    • Rappaz B, Barbul A, Emery Y, Korenstein R, Depeursinge C, Magistretti PF, Marquet P. Comparative study of human erythrocytes by digital holographic microscopy, confocal microscopy, and impedence volume analyzer. Cytometry A 2008;73A:895-903.
    • (2008) Cytometry A , vol.73 A , pp. 895-903
    • Rappaz, B.1    Barbul, A.2    Emery, Y.3    Korenstein, R.4    Depeursinge, C.5    Magistretti, P.F.6    Marquet, P.7
  • 6
    • 0020966869 scopus 로고
    • Isovolumetric sphering of erythrocytes for more accurate and precise cell volume measurement by flow cytometry
    • Kim YR, Ornstein L. Isovolumetric sphering of erythrocytes for more accurate and precise cell volume measurement by flow cytometry. Cytometry 1983;3:419-427.
    • (1983) Cytometry , vol.3 , pp. 419-427
    • Kim, Y.R.1    Ornstein, L.2
  • 7
    • 84897108807 scopus 로고    scopus 로고
    • Disorders of Hemoglobin: Genetics, Pathophysiology, and Clinical Management. Cambridge, UK: Cambridge University Press
    • Steinberg MH, Forget BG, Higgs DR, Nagel RL, Franklin Bunn H. Disorders of Hemoglobin: Genetics, Pathophysiology, and Clinical Management. Cambridge, UK: Cambridge University Press; 2000.
    • (2000)
    • Steinberg, M.H.1    Forget, B.G.2    Higgs, D.R.3    Nagel, R.L.4    Franklin Bunn, H.5
  • 8
    • 71849119430 scopus 로고    scopus 로고
    • Spectroscopic phase microscopy for quantifying hemoglobin concentrations in intact red blood cells
    • Park Y, Yamauchi T, Choi W, Dasari R, Feld MS. Spectroscopic phase microscopy for quantifying hemoglobin concentrations in intact red blood cells. Opt Lett 2009;34:3668-3670.
    • (2009) Opt Lett , vol.34 , pp. 3668-3670
    • Park, Y.1    Yamauchi, T.2    Choi, W.3    Dasari, R.4    Feld, M.S.5
  • 9
    • 84861180712 scopus 로고    scopus 로고
    • Blood testing at the single cell level using quantitative phase and amplitude microscopy
    • Mir M, Tangella K, Popescu G. Blood testing at the single cell level using quantitative phase and amplitude microscopy. Opt Exp 2011;2:3259-3266.
    • (2011) Opt Exp , vol.2 , pp. 3259-3266
    • Mir, M.1    Tangella, K.2    Popescu, G.3
  • 10
    • 84857354555 scopus 로고    scopus 로고
    • Phase imaging flow cytometry using a focus-stack collecting microscope
    • Gorthi SS, Schonbrun E. Phase imaging flow cytometry using a focus-stack collecting microscope. Opt Lett 2012;37:707-709.
    • (2012) Opt Lett , vol.37 , pp. 707-709
    • Gorthi, S.S.1    Schonbrun, E.2
  • 11
    • 0020966191 scopus 로고
    • A new method for cell volume measurement based on volume exclusion of a fluorescence dye
    • Gray ML, Hoffman RA, Hansen WP. A new method for cell volume measurement based on volume exclusion of a fluorescence dye. Cytometry 1983;3:428-434.
    • (1983) Cytometry , vol.3 , pp. 428-434
    • Gray, M.L.1    Hoffman, R.A.2    Hansen, W.P.3
  • 12
    • 46749096804 scopus 로고    scopus 로고
    • Measurement of the absorption of concentrated dyes and their use for quantitative imaging of surface topography
    • Model MA, Khitrin AK, Blank JL. Measurement of the absorption of concentrated dyes and their use for quantitative imaging of surface topography. J Micro 2008;231:156-167.
    • (2008) J Micro , vol.231 , pp. 156-167
    • Model, M.A.1    Khitrin, A.K.2    Blank, J.L.3
  • 13
    • 84875987594 scopus 로고    scopus 로고
    • Dye exclusion microfluidic microscopy
    • Schonbrun E, DiCaprio G, Schaak D. Dye exclusion microfluidic microscopy. Opt Exp 2013;21:8793-8798.
    • (2013) Opt Exp , vol.21 , pp. 8793-8798
    • Schonbrun, E.1    Dicaprio, G.2    Schaak, D.3
  • 14
    • 84897115188 scopus 로고    scopus 로고
    • Tabulated molar extinction coefficient for hemoglobin in water. Available at:
    • Prahl S. Tabulated molar extinction coefficient for hemoglobin in water. Available at: http://omlc.ogi.edu/spectra/hemoglobin/summary.html, 1998.
    • (1998)
    • Prahl, S.1
  • 15
    • 34548041671 scopus 로고    scopus 로고
    • Measurement of the refractive index of distilled water from the near-infrared region to the ultraviolet region
    • Daimon M, Masumura A. Measurement of the refractive index of distilled water from the near-infrared region to the ultraviolet region. App Opt 2007;46:3811-3820.
    • (2007) App Opt , vol.46 , pp. 3811-3820
    • Daimon, M.1    Masumura, A.2
  • 16
    • 84897110221 scopus 로고
    • An ultracentrifugal investigation of the serum proteins
    • McFarlane AS. An ultracentrifugal investigation of the serum proteins. Biochem J 1935;29:407-429.
    • (1935) Biochem J , vol.29 , pp. 407-429
    • Mcfarlane, A.S.1
  • 17
    • 33745159952 scopus 로고    scopus 로고
    • Model function to calculate the refractive index of native hemoglobin in the wavelength range of 250-1100 nm dependent on concentration
    • Friebel M, Meinke M. Model function to calculate the refractive index of native hemoglobin in the wavelength range of 250-1100 nm dependent on concentration. App Opt 2006;12:2838-2842.
    • (2006) App Opt , vol.12 , pp. 2838-2842
    • Friebel, M.1    Meinke, M.2
  • 18
    • 34447557968 scopus 로고
    • Refractive index of concentrated protein solutions
    • Barer R, Tkaczyk S. Refractive index of concentrated protein solutions. Nature 1954;173:821-822.
    • (1954) Nature , vol.173 , pp. 821-822
    • Barer, R.1    Tkaczyk, S.2
  • 19
    • 78549269076 scopus 로고    scopus 로고
    • Measurement of the thickness and volume of adherent cells using transmission-through-dye microscopy
    • Gregg JL, McGuire KM, Focht DC, Model MA. Measurement of the thickness and volume of adherent cells using transmission-through-dye microscopy. Pflugers Arch 2010;460:1097-1104.
    • (2010) Pflugers Arch , vol.460 , pp. 1097-1104
    • Gregg, J.L.1    Mcguire, K.M.2    Focht, D.C.3    Model, M.A.4
  • 20
    • 0036290221 scopus 로고    scopus 로고
    • Pixels to pictograms: A beginners' guide to genome quantification by Feulgen image analysis densitometry
    • Hardie DC, Gregory TR, Hebert PDN. Pixels to pictograms: A beginners' guide to genome quantification by Feulgen image analysis densitometry. Histochem Cytochem 2002;50:735-749.
    • (2002) Histochem Cytochem , vol.50 , pp. 735-749
    • Hardie, D.C.1    Gregory, T.R.2    Hebert, P.D.N.3
  • 21
    • 80054924515 scopus 로고    scopus 로고
    • Deep ultraviolet mapping of intracellular protein and nucleic acid in femtograms per pixel
    • Cheung MC, Evans JG, McKenna B, Ehrlich DJ. Deep ultraviolet mapping of intracellular protein and nucleic acid in femtograms per pixel. Cytometry A 2011;79A:920-932.
    • (2011) Cytometry A , vol.79 A , pp. 920-932
    • Cheung, M.C.1    Evans, J.G.2    Mckenna, B.3    Ehrlich, D.J.4
  • 22
    • 0015411265 scopus 로고
    • Improved measurement of the erythrocyte geometry
    • Evans E, Fung YC. Improved measurement of the erythrocyte geometry. Microvasc Res 1972;4:335-347.
    • (1972) Microvasc Res , vol.4 , pp. 335-347
    • Evans, E.1    Fung, Y.C.2
  • 23
    • 0014668756 scopus 로고
    • Deformation of red blood cells in capillaries
    • Skalak R, Branemark PI. Deformation of red blood cells in capillaries. Science 1969;164:717-719.
    • (1969) Science , vol.164 , pp. 717-719
    • Skalak, R.1    Branemark, P.I.2
  • 25
    • 84055182561 scopus 로고    scopus 로고
    • Microfabricated multiple field of view imaging flow cytometry
    • Schonbrun E, Gorthi SS, Schaak D. Microfabricated multiple field of view imaging flow cytometry. Lab Chip 2012;12:268-273.
    • (2012) Lab Chip , vol.12 , pp. 268-273
    • Schonbrun, E.1    Gorthi, S.S.2    Schaak, D.3
  • 26
    • 58149158216 scopus 로고    scopus 로고
    • Red cell membrane: Past, present, and future
    • Mohandes N, Gallagher PG. Red cell membrane: Past, present, and future. Blood 2008;15:3939-3948.
    • (2008) Blood , vol.15 , pp. 3939-3948
    • Mohandes, N.1    Gallagher, P.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.