메뉴 건너뛰기




Volumn 19, Issue 2, 2014, Pages 72-75

Relationship between noninvasive and invasive blood pressure values in end-stage renal disease patients on dialysis

Author keywords

Accuracy; Invasive blood pressure; Mechanism; Noninvasive blood pressure; Uremia

Indexed keywords

ADULT; ARTERIAL WALL THICKNESS; ARTERIOGRAPHY; ARTERY CATHETERIZATION; ARTICLE; BLOOD FLOW; BLOOD PRESSURE MEASUREMENT; BLOOD PRESSURE MONITOR; CARDIOVASCULAR PARAMETERS; CAROTID ENDDIASTOLIC VELOCITY; CAROTID PEAK SYSTOLIC VELOCITY; CAROTID PULSATING INDEX; CAROTID RESISTIVE INDEX; CLINICAL ARTICLE; DIASTOLIC BLOOD PRESSURE; ECHOARTERIOGRAPHY; ECHOGRAPHY; END STAGE RENAL DISEASE; FEMALE; HEMODYNAMICS; HUMAN; INTERMETHOD COMPARISON; INVASIVE PROCEDURE; MALE; MIDDLE AGED; NON INVASIVE PROCEDURE; OSCILLOMETER; OSCILLOMETRY; PERIPHERAL VENOUS CATHETER; PRIORITY JOURNAL; RADIAL ARTERY; RADIAL ARTERY CATHETERIZATION; RENAL REPLACEMENT THERAPY; SYSTOLIC BLOOD PRESSURE;

EID: 84896903132     PISSN: 13595237     EISSN: 14735725     Source Type: Journal    
DOI: 10.1097/MBP.0000000000000026     Document Type: Article
Times cited : (5)

References (19)
  • 3
    • 0035134192 scopus 로고    scopus 로고
    • End-stage renal disease, atherosclerosis, and cardiovascular mortality: Is C-reactive protein the missing link?
    • Arici M, Walls J. End-stage renal disease, atherosclerosis, and cardiovascular mortality: Is C-reactive protein the missing link? Kidney Int 2001; 59: 407-414.
    • (2001) Kidney Int , vol.59 , pp. 407-414
    • Arici, M.1    Walls, J.2
  • 4
    • 0035315782 scopus 로고    scopus 로고
    • Pseudohypertension in a patient with diffuse scleroderma
    • Rosner MH, Okusa MD. Pseudohypertension in a patient with diffuse scleroderma. Am J Kidney Dis 2001; 37: 32-32.
    • (2001) Am J Kidney Dis , vol.37 , pp. 32-32
    • Rosner, M.H.1    Okusa, M.D.2
  • 8
    • 0028242927 scopus 로고
    • Direct and indirect blood pressure in normotensive and hypertensive subjects
    • Fagher B, Magnússon J, Thulin T. Direct and indirect blood pressure in normotensive and hypertensive subjects. J Intern Med 1994; 236: 85-90.
    • (1994) J Intern Med , vol.236 , pp. 85-90
    • Fagher, B.1    Magnússon, J.2    Thulin, T.3
  • 9
    • 34248369753 scopus 로고    scopus 로고
    • Comparison of noninvasive oscillometric and intra-arterial blood pressure measurements in hyperacute stroke
    • Manios E, Vemmos K, Tsivgoulis G, Barlas G, Koroboki E, Spengos K, et al. Comparison of noninvasive oscillometric and intra-arterial blood pressure measurements in hyperacute stroke. Blood Press Monit 2007; 12: 149-156.
    • (2007) Blood Press Monit , vol.12 , pp. 149-156
    • Manios, E.1    Vemmos, K.2    Tsivgoulis, G.3    Barlas, G.4    Koroboki, E.5    Spengos, K.6
  • 10
    • 0037466925 scopus 로고    scopus 로고
    • Measuring blood pressure accurately. New and persistent changes
    • Jones DW, Appel LJ, Sheps SG, Roccella EJ, Lenfant C. Measuring blood pressure accurately. New and persistent changes. JAMA 2003; 289: 1027-1030.
    • (2003) JAMA , vol.289 , pp. 1027-1030
    • Jones, D.W.1    Appel, L.J.2    Sheps, S.G.3    Roccella, E.J.4    Lenfant, C.5
  • 11
    • 0034051418 scopus 로고    scopus 로고
    • Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients
    • Bur A, Hirschl MM, Herkner H, Oschatz E, Kofler J, Woisetschläger C, et al. Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients. Crit Care Med 2000; 28: 371-376.
    • (2000) Crit Care Med , vol.28 , pp. 371-376
    • Bur, A.1    Hirschl, M.M.2    Herkner, H.3    Oschatz, E.4    Kofler, J.5    Woisetschläger, C.6
  • 12
    • 67349105014 scopus 로고    scopus 로고
    • A poor correlation exists between oscillometric and radial arterial blood pressure as measured by the Philips MP90 monitor
    • Mireles SA, Jaffe RA, Drover DR, Brock-Utne JG. A poor correlation exists between oscillometric and radial arterial blood pressure as measured by the Philips MP90 monitor. J Clin Monit Comput 2009; 23: 169-174.
    • (2009) J Clin Monit Comput , vol.23 , pp. 169-174
    • Mireles, S.A.1    Jaffe, R.A.2    Drover, D.R.3    Brock-Utne, J.G.4
  • 13
    • 0037351948 scopus 로고    scopus 로고
    • Factors influencing the accuracy of oscillometric blood pressure measurement in critically ill patients
    • Bur A, Herkner H, Vlcek M, Woisetschläger C, Derhaschnig U, Delle Karth G, et al. Factors influencing the accuracy of oscillometric blood pressure measurement in critically ill patients. Crit Care Med 2003; 31: 793-799.
    • (2003) Crit Care Med , vol.31 , pp. 793-799
    • Bur, A.1    Herkner, H.2    Vlcek, M.3    Woisetschläger, C.4    Derhaschnig, U.5    Delle Karth, G.6
  • 14
    • 0034531946 scopus 로고    scopus 로고
    • An evaluation of a new continuous blood pressure monitoring system in critically ill patients
    • Heard SO, Lisbon A, Toth I, Ramasubramanian R. An evaluation of a new continuous blood pressure monitoring system in critically ill patients. J Clin Anesth 2000; 12: 509-518.
    • (2000) J Clin Anesth , vol.12 , pp. 509-518
    • Heard, S.O.1    Lisbon, A.2    Toth, I.3    Ramasubramanian, R.4
  • 15
    • 13444255966 scopus 로고    scopus 로고
    • Recommendations for blood pressure measurements in humans and experimental animals: Part 1: Blood pressure management in humans: A statement for professionals from the Subcomittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research
    • Pickering TG, Hall JE, Appel LJ, Falkner BE, Graves J, Hill MN, et al. Recommendations for blood pressure measurements in humans and experimental animals: part 1: blood pressure management in humans: a statement for professionals from the Subcomittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Circulation 2005; 111: 697-716.
    • (2005) Circulation , vol.111 , pp. 697-716
    • Pickering, T.G.1    Hall, J.E.2    Appel, L.J.3    Falkner, B.E.4    Graves, J.5    Hill, M.N.6
  • 16
    • 0037301090 scopus 로고    scopus 로고
    • What will replace the mercury sphygmomanometer?
    • Pickering TG. What will replace the mercury sphygmomanometer? Blood Press Monit 2003; 8: 23-25.
    • (2003) Blood Press Monit , vol.8 , pp. 23-25
    • Pickering, T.G.1
  • 17
    • 0024335341 scopus 로고
    • Determination of blood pressure level and changes in physiological situations: Comparison of the standard cuff method with direct intra-arterial recording
    • Turjanmaa V. Determination of blood pressure level and changes in physiological situations: comparison of the standard cuff method with direct intra-arterial recording. Clin Physiol 1989; 9: 373-387.
    • (1989) Clin Physiol , vol.9 , pp. 373-387
    • Turjanmaa, V.1
  • 18
    • 0036843885 scopus 로고    scopus 로고
    • Discrepancies between direct and indirect blood pressure measurement using various recommendations for arm cuff selection
    • Clark JA, Lieh-Lai MW. Discrepancies between direct and indirect blood pressure measurement using various recommendations for arm cuff selection. Pediatrics 2002; 110: 920-923.
    • (2002) Pediatrics , vol.110 , pp. 920-923
    • Clark, J.A.1    Lieh-Lai, M.W.2
  • 19
    • 0033841467 scopus 로고    scopus 로고
    • Optimizing cuff width for noninvasive measurement of blood pressure
    • Marks LA, Groeh A. Optimizing cuff width for noninvasive measurement of blood pressure. Blood 2000; 5: 153-158.
    • (2000) Blood , vol.5 , pp. 153-158
    • Marks, L.A.1    Groeh, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.