-
1
-
-
0032090927
-
Strengthening IAEA safeguards through environmental sampling and analysis
-
D.L. Donohue Strengthening IAEA safeguards through environmental sampling and analysis J. Alloy Comp. 271-273 1998 11 18
-
(1998)
J. Alloy Comp.
, vol.271-273
, pp. 11-18
-
-
Donohue, D.L.1
-
2
-
-
0036139305
-
Strengthened nuclear safeguards
-
D.L. Donohue Strengthened nuclear safeguards Anal. Chem. 74 2002 28A 35A
-
(2002)
Anal. Chem.
, vol.74
-
-
Donohue, D.L.1
-
3
-
-
37249035712
-
Assessment of plutonium measurement in the femtogram range by ICP-MS; Correction from interferring polyatomic species
-
F. Pointurier, P. Hémet, and A. Hubert Assessment of plutonium measurement in the femtogram range by ICP-MS; correction from interferring polyatomic species J. Anal. At. Spectrom. 23 2008 94 102
-
(2008)
J. Anal. At. Spectrom.
, vol.23
, pp. 94-102
-
-
Pointurier, F.1
Hémet, P.2
Hubert, A.3
-
4
-
-
34047131163
-
Development in fission track-thermal ionization mass spectrometry for particle analysis of safeguards environmental samples
-
C.G. Lee, K. Iguchi, J. Inagawa, D. Suzuki, F. Esaka, M. Magara, S. Sakurai, K. Watanabe, and S. Usuda Development in fission track-thermal ionization mass spectrometry for particle analysis of safeguards environmental samples J. Radioanal. Nucl. Chem. 272 2007 299 302
-
(2007)
J. Radioanal. Nucl. Chem.
, vol.272
, pp. 299-302
-
-
Lee, C.G.1
Iguchi, K.2
Inagawa, J.3
Suzuki, D.4
Esaka, F.5
Magara, M.6
Sakurai, S.7
Watanabe, K.8
Usuda, S.9
-
5
-
-
48549084984
-
Study on analysis of isotopic ratio of uranium-bearing particle in swipe samples by FT-TIMS
-
Y. Shen, Y. Zhao, S.L. Guo, J. Cui, Y. Liu, J. Li, J. Xu, and H. Zhang Study on analysis of isotopic ratio of uranium-bearing particle in swipe samples by FT-TIMS Radiat. Meas. 43 2008 S299 S302
-
(2008)
Radiat. Meas.
, vol.43
-
-
Shen, Y.1
Zhao, Y.2
Guo, S.L.3
Cui, J.4
Liu, Y.5
Li, J.6
Xu, J.7
Zhang, H.8
-
6
-
-
0032139247
-
Application of secondary ion mass spectrometry to the identification of single particles of uranium and their isotopic measurement
-
G. Tamborini, M. Betti, V. Forcina, T. Hiernaut, B. Giovannone, and L. Koch Application of secondary ion mass spectrometry to the identification of single particles of uranium and their isotopic measurement Spectrochim. Acta B 53 1998 1289 1302
-
(1998)
Spectrochim. Acta B
, vol.53
, pp. 1289-1302
-
-
Tamborini, G.1
Betti, M.2
Forcina, V.3
Hiernaut, T.4
Giovannone, B.5
Koch, L.6
-
7
-
-
0001333809
-
Characterisation of radioactive particles by SIMS
-
G. Tamborini, and M. Betti Characterisation of radioactive particles by SIMS Mikrochim. Acta 132 2000 411 417
-
(2000)
Mikrochim. Acta
, vol.132
, pp. 411-417
-
-
Tamborini, G.1
Betti, M.2
-
8
-
-
33846476626
-
Particle isolation for analysis of uranium minor isotopes in individual particles by secondary ion mass spectrometry
-
F. Esaka, K.T. Esaka, C.G. Lee, M. Magara, S. Sakurai, S. Usuda, and K. Watanabe Particle isolation for analysis of uranium minor isotopes in individual particles by secondary ion mass spectrometry Talanta 71 2007 1011 1015
-
(2007)
Talanta
, vol.71
, pp. 1011-1015
-
-
Esaka, F.1
Esaka, K.T.2
Lee, C.G.3
Magara, M.4
Sakurai, S.5
Usuda, S.6
Watanabe, K.7
-
9
-
-
61349176011
-
Improved isotopic SIMS measurements of uranium particles for nuclear safeguards purposes
-
Y. Ranebo, P.M.L. Hedberg, M.J. Whitehouse, K. Ingeneri, and S. Littman Improved isotopic SIMS measurements of uranium particles for nuclear safeguards purposes J. Anal. At. Spectrom. 24 2009 277 287
-
(2009)
J. Anal. At. Spectrom.
, vol.24
, pp. 277-287
-
-
Ranebo, Y.1
Hedberg, P.M.L.2
Whitehouse, M.J.3
Ingeneri, K.4
Littman, S.5
-
10
-
-
37749011359
-
Determining the isotopic compositions of uranium and fission products in radioactive environmental microsamples using laser ablation ICP-MS with multiple ion counters
-
S.F. Boulyga, and T. Prohaska Determining the isotopic compositions of uranium and fission products in radioactive environmental microsamples using laser ablation ICP-MS with multiple ion counters Anal. Bioanal. Chem. 390 2008 531 539
-
(2008)
Anal. Bioanal. Chem.
, vol.390
, pp. 531-539
-
-
Boulyga, S.F.1
Prohaska, T.2
-
11
-
-
38149133601
-
Recent applications on isotope ratio measurements by ICP-MS and LA-ICP-MS on biological samples and single particles
-
S.J. Becker, H. Sela, J. Dobrowolska, M. Zoriy, and S.J. Becker Recent applications on isotope ratio measurements by ICP-MS and LA-ICP-MS on biological samples and single particles Int. J. Mass Spectrom. 270 2008 1 7
-
(2008)
Int. J. Mass Spectrom.
, vol.270
, pp. 1-7
-
-
Becker, S.J.1
Sela, H.2
Dobrowolska, J.3
Zoriy, M.4
Becker, S.J.5
-
12
-
-
49449115442
-
Application of laser ablation inductively coupled plasma mass spectrometry for the isotopic analysis of single uranium particles
-
Z. Varga Application of laser ablation inductively coupled plasma mass spectrometry for the isotopic analysis of single uranium particles Anal. Chim. Acta. 625 2008 1 7
-
(2008)
Anal. Chim. Acta.
, vol.625
, pp. 1-7
-
-
Varga, Z.1
-
13
-
-
71749096571
-
Precise and accurate isotopic analysis of microscopic uranium-oxide grains using LA-MC-ICP-MS
-
N.S. Lloyd, R.R. Parrish, M.S.A. Horstwood, and S.R.N. Chenery Precise and accurate isotopic analysis of microscopic uranium-oxide grains using LA-MC-ICP-MS J. Anal. At. Spectrom. 24 2009 752 758
-
(2009)
J. Anal. At. Spectrom.
, vol.24
, pp. 752-758
-
-
Lloyd, N.S.1
Parrish, R.R.2
Horstwood, M.S.A.3
Chenery, S.R.N.4
-
14
-
-
84860996707
-
Direct uranium isotope ratio analysis of single micrometer-sized glass particles
-
S. Kappel, S.F. Boulyga, and T. Prohaska Direct uranium isotope ratio analysis of single micrometer-sized glass particles J. Environ. Radioact. 113 2012 8 15
-
(2012)
J. Environ. Radioact.
, vol.113
, pp. 8-15
-
-
Kappel, S.1
Boulyga, S.F.2
Prohaska, T.3
-
15
-
-
84877987014
-
Faesibility study of isotope ratio analysis of individual uranium-plutonium mixed oxide particles with SIMS and ICP-MS
-
F. Esaka, M. Magara, D. Suzuki, Y. Miyamoto, C.-G. Lee, and T. Kimura Faesibility study of isotope ratio analysis of individual uranium-plutonium mixed oxide particles with SIMS and ICP-MS Mass Spectrom. Lett. 2 2011 80 83
-
(2011)
Mass Spectrom. Lett.
, vol.2
, pp. 80-83
-
-
Esaka, F.1
Magara, M.2
Suzuki, D.3
Miyamoto, Y.4
Lee, C.-G.5
Kimura, T.6
-
16
-
-
80054714443
-
Application of nanosecond-UV laser ablation-inductively coupled plasma mass spectrometry for the isotopic analysis of single submicrometer-size uranium particles
-
F. Pointurier, A.C. Pottin, and A. Hubert Application of nanosecond-UV laser ablation-inductively coupled plasma mass spectrometry for the isotopic analysis of single submicrometer-size uranium particles Anal. Chem. 83 2011 7841 7848
-
(2011)
Anal. Chem.
, vol.83
, pp. 7841-7848
-
-
Pointurier, F.1
Pottin, A.C.2
Hubert, A.3
-
17
-
-
39749118781
-
Solid-spiking isotope dilution laser ablation ICP-MS for the direct and simultaneaous determination of trace elements in soils and sediments
-
B. Fernández, F. Claverie, C. Pécheyran, and O.F.X. Donard Solid-spiking isotope dilution laser ablation ICP-MS for the direct and simultaneaous determination of trace elements in soils and sediments J. Anal. At. Spectrom. 23 2008 367 377
-
(2008)
J. Anal. At. Spectrom.
, vol.23
, pp. 367-377
-
-
Fernández, B.1
Claverie, F.2
Pécheyran, C.3
Donard, O.F.X.4
-
18
-
-
33847384738
-
Ablation laser femtoseconde à haute cadence de tir et basse énergie couplée à une détection ICP-MS: Résultats prélliminaires
-
C. Pécheyran, S. Cany, and O.F.X. Donard Ablation laser femtoseconde à haute cadence de tir et basse énergie couplée à une détection ICP-MS: résultats prélliminaires Can. J. Anal. Sci. Spectrosc. 50 2005 272 283
-
(2005)
Can. J. Anal. Sci. Spectrosc.
, vol.50
, pp. 272-283
-
-
Pécheyran, C.1
Cany, S.2
Donard, O.F.X.3
-
19
-
-
36049012224
-
Direct analysis of solid samples by fs-LA-ICP-MS
-
B. Fernandez, F. Claverie, C. Pécheyran, O.F.X. Donard, and F. Claverie Direct analysis of solid samples by fs-LA-ICP-MS TrAC Trends Anal. Chem. 26 2007 951 966
-
(2007)
TrAC Trends Anal. Chem.
, vol.26
, pp. 951-966
-
-
Fernandez, B.1
Claverie, F.2
Pécheyran, C.3
Donard, O.F.X.4
Claverie, F.5
-
20
-
-
51949100711
-
Direct determination of trace elements in powdered samples by in-cell isotope dilution femtosecond laser ablation ICP-MS
-
B. Fernández, F. Claverie, C. Pécheyran, J. Alexis, and O.F.X. Donard Direct determination of trace elements in powdered samples by in-cell isotope dilution femtosecond laser ablation ICP-MS Anal. Chem. 80 2008 6981 6994
-
(2008)
Anal. Chem.
, vol.80
, pp. 6981-6994
-
-
Fernández, B.1
Claverie, F.2
Pécheyran, C.3
Alexis, J.4
Donard, O.F.X.5
-
21
-
-
67649703225
-
Elemental fractionation effects in high repetition rate IR femtosecond laser ablation ICP-MS analysis of glasses
-
F. Claverie, B. Fernandez, C. Pecheyran, J. Alexis, and O.F.X. Donard Elemental fractionation effects in high repetition rate IR femtosecond laser ablation ICP-MS analysis of glasses J. Anal. At. Spectrom. 24 2009 891 902
-
(2009)
J. Anal. At. Spectrom.
, vol.24
, pp. 891-902
-
-
Claverie, F.1
Fernandez, B.2
Pecheyran, C.3
Alexis, J.4
Donard, O.F.X.5
-
22
-
-
34547355646
-
High repetition rate and Row energy femtosecond laser ablation coupled to ICP-MS detection: A new analytical approach for trace element determination in solid samples
-
C. Pécheyran, S. Cany, P. Chabassier, E. Mottay, and O.F.X. Donard High repetition rate and Row energy femtosecond laser ablation coupled to ICP-MS detection: a new analytical approach for trace element determination in solid samples J. Phys. Conf. Ser. 59 2007 112 117
-
(2007)
J. Phys. Conf. Ser.
, vol.59
, pp. 112-117
-
-
Pécheyran, C.1
Cany, S.2
Chabassier, P.3
Mottay, E.4
Donard, O.F.X.5
-
23
-
-
84872841185
-
Nuclear safeguards applications using LG-SIMS with automated screening capabilities
-
P. Peres, P.M.L. Hedberg, S. Walton, N. Montgomery, J.B. Cliff, F. Rabemananjara, and M. Schuhmacher Nuclear safeguards applications using LG-SIMS with automated screening capabilities Surf. Interface Anal. 45 2013 561 565
-
(2013)
Surf. Interface Anal.
, vol.45
, pp. 561-565
-
-
Peres, P.1
Hedberg, P.M.L.2
Walton, S.3
Montgomery, N.4
Cliff, J.B.5
Rabemananjara, F.6
Schuhmacher, M.7
-
24
-
-
33747847404
-
Performance characteristics of ultraviolet femtosecond laser ablation inductively coupled plasma mass spectrometry at 265 and 200 nm
-
J. Koch, M. Wälle, J. Pisonero, and D. Günther Performance characteristics of ultraviolet femtosecond laser ablation inductively coupled plasma mass spectrometry at 265 and 200 nm J. Anal. At. Spectrom. 21 2006 932 940
-
(2006)
J. Anal. At. Spectrom.
, vol.21
, pp. 932-940
-
-
Koch, J.1
Wälle, M.2
Pisonero, J.3
Günther, D.4
-
25
-
-
44449128966
-
Femtosecond laser ablation: Experimental study of the repetition rate influence on inductively coupled plasma mass spectrometry performance
-
J.J. Gonzalez, A. Fernandez, D. Oropeza, X. Mao, and R.E. Russo Femtosecond laser ablation: experimental study of the repetition rate influence on inductively coupled plasma mass spectrometry performance Spectrochim. Acta B 63 2008 277 286
-
(2008)
Spectrochim. Acta B
, vol.63
, pp. 277-286
-
-
Gonzalez, J.J.1
Fernandez, A.2
Oropeza, D.3
Mao, X.4
Russo, R.E.5
-
26
-
-
58149177259
-
Detection efficiencies in nano- and femtosecond laser ablation inductively coupled plasma mass spectrometry
-
M. Wälle, J. Koch, L. Flamigni, S. Heiroth, T. Lippert, W. Hartung, and D. Günther Detection efficiencies in nano- and femtosecond laser ablation inductively coupled plasma mass spectrometry Spectrochim. Acta B 64 2009 109 112
-
(2009)
Spectrochim. Acta B
, vol.64
, pp. 109-112
-
-
Wälle, M.1
Koch, J.2
Flamigni, L.3
Heiroth, S.4
Lippert, T.5
Hartung, W.6
Günther, D.7
-
27
-
-
79960343313
-
Multi-element model for the simulation of inductively coupled plasmas: Effects of helium addition to the central gas stream
-
H. Lindner, and A. Bogaerts Multi-element model for the simulation of inductively coupled plasmas: effects of helium addition to the central gas stream Spectrochim. Acta B 66 2011 421 431
-
(2011)
Spectrochim. Acta B
, vol.66
, pp. 421-431
-
-
Lindner, H.1
Bogaerts, A.2
-
28
-
-
84867379974
-
Considerations about the detection efficiency in inductively coupled plasma mass spectrometry
-
K. Niemax Considerations about the detection efficiency in inductively coupled plasma mass spectrometry Spectrochim. Acta B 76 2012 65 69
-
(2012)
Spectrochim. Acta B
, vol.76
, pp. 65-69
-
-
Niemax, K.1
-
30
-
-
79956059785
-
Comparison of heat-affected zones due to nanosecond and femtosecond laser pulses using transmission electronic microscopy
-
R. Le Harzic, N. Huot, E. Audouard, C. Jonin, P. Laporte, S. Valette, A. Fraczkiewicz, and R. Fortunier Comparison of heat-affected zones due to nanosecond and femtosecond laser pulses using transmission electronic microscopy Appl. Phys. Lett. 80 2002 3886
-
(2002)
Appl. Phys. Lett.
, vol.80
, pp. 3886
-
-
Le Harzic, R.1
Huot, N.2
Audouard, E.3
Jonin, C.4
Laporte, P.5
Valette, S.6
Fraczkiewicz, A.7
Fortunier, R.8
-
31
-
-
0037470431
-
The influence of ablation carrier gasses Ar, He and Ne on the particle size distribution and transport efficiencies of laser ablation-induced aerosols: Implications for LA-ICP-MS
-
I. Horn, and D. Günther The influence of ablation carrier gasses Ar, He and Ne on the particle size distribution and transport efficiencies of laser ablation-induced aerosols: implications for LA-ICP-MS Appl. Surf. Sci. 207 2003 144 157
-
(2003)
Appl. Surf. Sci.
, vol.207
, pp. 144-157
-
-
Horn, I.1
Günther, D.2
-
32
-
-
0032070169
-
Deposition and element fractionation processes during atmospheric pressure laser sampling for analysis by ICP-MS
-
S.M. Eggins, L.P.J. Kinsley, and J.M.G. Shelley Deposition and element fractionation processes during atmospheric pressure laser sampling for analysis by ICP-MS Appl. Surf. Sci. 127-129 1998 278 286
-
(1998)
Appl. Surf. Sci.
, vol.127-129
, pp. 278-286
-
-
Eggins, S.M.1
Kinsley, L.P.J.2
Shelley, J.M.G.3
-
33
-
-
0041912444
-
Enhanced sensitivity in laser ablation-ICP mass spectrometry using helium-argon mixtures as aerosol carrier
-
D. Günther, and C.A. Heinrich Enhanced sensitivity in laser ablation-ICP mass spectrometry using helium-argon mixtures as aerosol carrier J. Anal. At. Spectrom. 14 1999 1363 1368
-
(1999)
J. Anal. At. Spectrom.
, vol.14
, pp. 1363-1368
-
-
Günther, D.1
Heinrich, C.A.2
-
34
-
-
33744812707
-
On-line additions of aqueous standards for calibration of laser ablation inductively coupled plasma mass spectrometry. Theory and comparison of wet and dry plasma conditions
-
O'Connor, B.L. Sharp, and P. Evans On-line additions of aqueous standards for calibration of laser ablation inductively coupled plasma mass spectrometry. Theory and comparison of wet and dry plasma conditions J. Anal. At. Spectrom. 21 2006 556 565
-
(2006)
J. Anal. At. Spectrom.
, vol.21
, pp. 556-565
-
-
Oconnor1
Sharp, B.L.2
Evans, P.3
|