Volumn 75, Issue , 2014, Pages 181-188

Water flow rate models based on the pipe resistance and pressure difference in multiple parallel chiller systems

Author keywords

Model; Multiple parallel chillers; Pipe resistance coefficient; Pressure difference; Water flow rate

Indexed keywords

MODEL COEFFICIENT; MULTIPLE PARALLEL CHILLERS; PARTIAL FLOW RATE; PIPE RESISTANCE; PRESSURE DIFFERENCES; PROTOTYPE SYSTEM; RESISTANCE COEFFICIENTS; WATER FLOW RATE;

EID: 84896802968     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2014.02.017     Document Type: Article
Times cited : (21)

References (24)
  • 1
    • 0344826836 scopus 로고    scopus 로고
    • Evaluation of the suitability of different chiller performance models for on-line training applied to automated fault detection and diagnosis
    • T.A. Reddy, D. Niebur, K.K. Andersen, P.P. Pericolo, and G. Cabrera Evaluation of the suitability of different chiller performance models for on-line training applied to automated fault detection and diagnosis HVAC Research 9 4 2003 385 414
    • (2003) HVAC Research , vol.9 , Issue.4 , pp. 385-414
    • Reddy, T.A.1    Niebur, D.2    Andersen, K.K.3    Pericolo, P.P.4    Cabrera, G.5
  • 2
    • 84964609875 scopus 로고    scopus 로고
    • Evaluation of the simple thermodynamic model (Gordon and NG universal chiller model) as a fault detection and diagnosis tool for on-site centrifugal chillers
    • J. Saththasivam, G. Tang, and K.C. Ng Evaluation of the simple thermodynamic model (Gordon and NG universal chiller model) as a fault detection and diagnosis tool for on-site centrifugal chillers International Journal of Air-Conditioning and Refrigeration 18 1 2010 55 60
    • (2010) International Journal of Air-Conditioning and Refrigeration , vol.18 , Issue.1 , pp. 55-60
    • Saththasivam, J.1    Tang, G.2    Ng, K.C.3
  • 5
    • 78649587931 scopus 로고    scopus 로고
    • A steady-state model for the design and optimization of a centralized cooling system
    • A.H. Beitelmal, and C.D. Patel A steady-state model for the design and optimization of a centralized cooling system International Journal of Energy Research 34 2010 1239 1248
    • (2010) International Journal of Energy Research , vol.34 , pp. 1239-1248
    • Beitelmal, A.H.1    Patel, C.D.2
  • 6
    • 0029306202 scopus 로고
    • Centrifugal chillers: Thermodynamic modelling and a diagnostic case study
    • J.M. Gordon, K.C. Ng, and H.T. Chua Centrifugal chillers: thermodynamic modelling and a diagnostic case study International Journal of Refrigeration 18 4 1995 253 257
    • (1995) International Journal of Refrigeration , vol.18 , Issue.4 , pp. 253-257
    • Gordon, J.M.1    Ng, K.C.2    Chua, H.T.3
  • 7
    • 77955176108 scopus 로고    scopus 로고
    • An evaluation of empirically-based models for predicting energy performance of vapor-compression water chillers
    • T.S. Lee, and W.C. Lu An evaluation of empirically-based models for predicting energy performance of vapor-compression water chillers Applied Energy 87 2010 3486 3493
    • (2010) Applied Energy , vol.87 , pp. 3486-3493
    • Lee, T.S.1    Lu, W.C.2
  • 8
    • 0037382315 scopus 로고    scopus 로고
    • A comparison of empirically based steady-state models for vapor compression liquid chillers
    • D.J. Swider A comparison of empirically based steady-state models for vapor compression liquid chillers Applied Thermal Engineering 23 5 2003 539 556
    • (2003) Applied Thermal Engineering , vol.23 , Issue.5 , pp. 539-556
    • Swider, D.J.1
  • 9
    • 0036165722 scopus 로고    scopus 로고
    • An evaluation of classical steady-state off-line linear parameter estimation methods applied to chiller performance data
    • T.A. Reddy, and K.K. Andersen An evaluation of classical steady-state off-line linear parameter estimation methods applied to chiller performance data HVAC Research 8 1 2002 101 124
    • (2002) HVAC Research , vol.8 , Issue.1 , pp. 101-124
    • Reddy, T.A.1    Andersen, K.K.2
  • 10
    • 0031103961 scopus 로고    scopus 로고
    • Diagnostics and optimization of reciprocating chillers: Theory and experiment
    • K.C. Ng, H.T. Chua, W. Ong, S.S. Lee, and J.M. Gordon Diagnostics and optimization of reciprocating chillers: theory and experiment Applied Thermal Engineering 17 3 1996 263 276
    • (1996) Applied Thermal Engineering , vol.17 , Issue.3 , pp. 263-276
    • Ng, K.C.1    Chua, H.T.2    Ong, W.3    Lee, S.S.4    Gordon, J.M.5
  • 11
    • 2442454790 scopus 로고    scopus 로고
    • Thermodynamic modeling and experimental validation of screw liquid chillers
    • T.S. Lee Thermodynamic modeling and experimental validation of screw liquid chillers ASHRAE Transactions 110 1 2004 206 216
    • (2004) ASHRAE Transactions , vol.110 , Issue.1 , pp. 206-216
    • Lee, T.S.1
  • 12
    • 84866422510 scopus 로고    scopus 로고
    • Chiller system performance benchmark by data envelopment analysis
    • F.W. Yu, and K.T. Chan Chiller system performance benchmark by data envelopment analysis International Journal of Refrigeration 35 2012 1815 1823
    • (2012) International Journal of Refrigeration , vol.35 , pp. 1815-1823
    • Yu, F.W.1    Chan, K.T.2
  • 13
    • 82155186706 scopus 로고    scopus 로고
    • Improved energy management of chiller systems by multivariate and data envelopment analyses
    • F.W. Yu, and K.T. Chan Improved energy management of chiller systems by multivariate and data envelopment analyses Applied Energy 92 2012 168 174
    • (2012) Applied Energy , vol.92 , pp. 168-174
    • Yu, F.W.1    Chan, K.T.2
  • 14
    • 81855207441 scopus 로고    scopus 로고
    • Using cluster and multivariate analyses to appraise the operating performance of a chiller system serving an institutional building
    • F.W. Yu, and K.T. Chan Using cluster and multivariate analyses to appraise the operating performance of a chiller system serving an institutional building Energy and Buildings 44 2012 104 113
    • (2012) Energy and Buildings , vol.44 , pp. 104-113
    • Yu, F.W.1    Chan, K.T.2
  • 15
    • 84873126742 scopus 로고    scopus 로고
    • Optimal chiller loading in a district cooling system with thermal energy storage
    • K.M. Powell, W.J. Cole, U.F. Ekarika, and T.F. Edgar Optimal chiller loading in a district cooling system with thermal energy storage Energy 50 2013 445 453
    • (2013) Energy , vol.50 , pp. 445-453
    • Powell, K.M.1    Cole, W.J.2    Ekarika, U.F.3    Edgar, T.F.4
  • 16
    • 17144445859 scopus 로고    scopus 로고
    • Reevaluation of the Gordon-Ng performance models for water-cooled chillers
    • W. Jiang, and T.A. Reddy Reevaluation of the Gordon-Ng performance models for water-cooled chillers ASHRAE transactions 109 2 2003 272 287
    • (2003) ASHRAE Transactions , vol.109 , Issue.2 , pp. 272-287
    • Jiang, W.1    Reddy, T.A.2
  • 17
    • 1342281360 scopus 로고    scopus 로고
    • A novel energy conservation method-optimal chiller loading
    • Y.C. Chang A novel energy conservation method-optimal chiller loading Electric Power Systems Research 69 2004 221 226
    • (2004) Electric Power Systems Research , vol.69 , pp. 221-226
    • Chang, Y.C.1
  • 19
    • 71649114479 scopus 로고    scopus 로고
    • Economic benefits of optimal control for water-cooled chiller systems serving hotels in a subtropical climate
    • F.W. Yu, and K.T. Chan Economic benefits of optimal control for water-cooled chiller systems serving hotels in a subtropical climate Energy and Buildings 42 2010 203 209
    • (2010) Energy and Buildings , vol.42 , pp. 203-209
    • Yu, F.W.1    Chan, K.T.2
  • 20
    • 33744519423 scopus 로고    scopus 로고
    • An outstanding method for saving energy - Optimal chiller operation
    • Y.C. Chang An outstanding method for saving energy - optimal chiller operation IEEE Transactions on Energy Conversion 21 2 2006 527 532
    • (2006) IEEE Transactions on Energy Conversion , vol.21 , Issue.2 , pp. 527-532
    • Chang, Y.C.1
  • 23
    • 69249241730 scopus 로고    scopus 로고
    • Chiller sequencing control with enhanced robustness for energy efficient operation
    • Y. Sun, S.W. Wang, and G.S. Huang Chiller sequencing control with enhanced robustness for energy efficient operation Energy and Buildings 41 2009 1246 1255
    • (2009) Energy and Buildings , vol.41 , pp. 1246-1255
    • Sun, Y.1    Wang, S.W.2    Huang, G.S.3
  • 24


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.