메뉴 건너뛰기




Volumn 44, Issue 1, 2012, Pages 104-113

Using cluster and multivariate analyses to appraise the operating performance of a chiller system serving an institutional building

Author keywords

Multiple linear regression; Two step cluster; Water cooled chiller

Indexed keywords

CHILLED WATER; CHILLER SYSTEM; DEGREE OF CORRELATIONS; INSTITUTIONAL BUILDING; MAXIMUM COP; MULTI VARIATE ANALYSIS; MULTIPLE LINEAR REGRESSIONS; OPERATING CHARACTERISTICS; OPERATING CONDITION; OPERATING PERFORMANCE; OPERATING PROBLEMS; OPERATING VARIABLES; OPTIMAL CONTROLS; STATISTICAL TOOLS; SYSTEM COEFFICIENT OF PERFORMANCE; SYSTEM LOADS; SYSTEMATIC METHOD; TWO-STEP CLUSTER; WATER PUMP; WATER-COOLED CHILLER; WEATHER PARAMETERS;

EID: 81855207441     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2011.10.026     Document Type: Article
Times cited : (23)

References (12)
  • 1
    • 70649098222 scopus 로고    scopus 로고
    • Online sensor fault diagnosis for robust chiller sequencing control
    • Y. Sun, S. Wang, and G. Huang Online sensor fault diagnosis for robust chiller sequencing control International Journal of Thermal Sciences 49 2010 589 602
    • (2010) International Journal of Thermal Sciences , vol.49 , pp. 589-602
    • Sun, Y.1    Wang, S.2    Huang, G.3
  • 2
    • 0037382315 scopus 로고    scopus 로고
    • A comparison of empirically based steady-state models for vapor-compression liquid chillers
    • D.J. Swider A comparison of empirically based steady-state models for vapor-compression liquid chillers Applied Thermal Engineering 23 2003 539 556
    • (2003) Applied Thermal Engineering , vol.23 , pp. 539-556
    • Swider, D.J.1
  • 4
    • 35348865601 scopus 로고    scopus 로고
    • Enhanced chiller sensor fault detection, diagnosis and estimation using wavelet analysis and principal component analysis methods
    • DOI 10.1016/j.applthermaleng.2007.03.021, PII S135943110700107X
    • X. Xu, X. Fu, and S. Wang S Enhanced chiller sensor fault detection, diagnosis and estimation using wavelet analysis and principal component analysis methods Applied Thermal Engineering 28 2008 226 237 (Pubitemid 47576718)
    • (2008) Applied Thermal Engineering , vol.28 , Issue.2-3 , pp. 226-237
    • Xu, X.1    Xiao, F.2    Wang, S.3
  • 5
    • 10444225302 scopus 로고    scopus 로고
    • Analysis of the component characteristics of air-cooled chillers for modelling floating condensing temperature control
    • K.T. Chan, and F.W. Yu Analysis of the component characteristics of air-cooled chillers for modelling floating condensing temperature control Energy Conversion and Management 46 6 2005 927 939
    • (2005) Energy Conversion and Management , vol.46 , Issue.6 , pp. 927-939
    • Chan, K.T.1    Yu, F.W.2
  • 6
    • 0035441048 scopus 로고    scopus 로고
    • All-variable speed centrifugal chiller plants
    • T. Hartman All-variable speed centrifugal chiller plants ASHRAE Journal 43 9 2001 43 53 (Pubitemid 32990975)
    • (2001) ASHRAE Journal , vol.43 , Issue.9 , pp. 43-53
    • Hartman, T.1
  • 7
    • 60549112393 scopus 로고    scopus 로고
    • An analysis of climatic influences on chiller plant electricity consumption
    • J.C. Lam, K.K.W. Wan, and K.L. Cheung An analysis of climatic influences on chiller plant electricity consumption Applied Energy 86 2009 933 940
    • (2009) Applied Energy , vol.86 , pp. 933-940
    • Lam, J.C.1    Wan, K.K.W.2    Cheung, K.L.3
  • 8
    • 38549176301 scopus 로고    scopus 로고
    • Principal component analysis of electricity use in office buildings
    • DOI 10.1016/j.enbuild.2007.06.001, PII S0378778807001764
    • J.C. Lam, K.K.W. Wan, K.L. Cheung, and Y. Liu Principal component analysis of electricity use in office buildings Energy and buildings 40 2008 828 836 (Pubitemid 351163003)
    • (2008) Energy and Buildings , vol.40 , Issue.5 , pp. 828-836
    • Lam, J.C.1    Wan, K.K.W.2    Cheung, K.L.3    Yang, L.4
  • 9
    • 55549112845 scopus 로고    scopus 로고
    • Building energy parameter investigations based on multivariate analysis
    • T. Olofsson, S. Andersson, and J.U. Sjögren Building energy parameter investigations based on multivariate analysis Energy and Buildings 41 2009 71 80
    • (2009) Energy and Buildings , vol.41 , pp. 71-80
    • Olofsson, T.1    Andersson, S.2    Sjögren, J.U.3
  • 10
    • 84918498484 scopus 로고    scopus 로고
    • SPSS, SPSS for Windows Documentation, Available at http://support.spss. com/ProductsExt/SPSS/Documentation/SPSSforWindows/index.html#16.
    • SPSS, SPSS for Windows Documentation
  • 11
    • 4043115470 scopus 로고    scopus 로고
    • Optimizing chillers and towers
    • H. Crowther, and J. Furlong Optimizing chillers and towers ASHRAE Journal 46 7 2004 34 40
    • (2004) ASHRAE Journal , vol.46 , Issue.7 , pp. 34-40
    • Crowther, H.1    Furlong, J.2
  • 12
    • 71649114479 scopus 로고    scopus 로고
    • Economic benefits of optimal control for water-cooled chiller systems serving hotels in a subtropical climate
    • F.W. Yu, and K.T. Chan Economic benefits of optimal control for water-cooled chiller systems serving hotels in a subtropical climate Energy and Buildings 42 2010 203 209
    • (2010) Energy and Buildings , vol.42 , pp. 203-209
    • Yu, F.W.1    Chan, K.T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.