메뉴 건너뛰기




Volumn 228, Issue 1, 2014, Pages 107-113

Biomechanical analysis using infrared thermography of a traditional metal plate versus a carbon fibre/epoxy plate for Vancouver B1 femur fractures

Author keywords

Biomechanics; Composite plate; Femur fracture; Metal plate; Thermography

Indexed keywords

BIOMECHANICAL ANALYSIS; BONE RESORPTION; COMPOSITE PLATES; IMPLANT LOOSENING; MECHANICAL STIFFNESS; METAL PLATES; STRESS SHIELDING; TOTAL HIP REPLACEMENT (THR);

EID: 84896742232     PISSN: 09544119     EISSN: 20413033     Source Type: Journal    
DOI: 10.1177/0954411913501489     Document Type: Article
Times cited : (18)

References (56)
  • 1
    • 84896786903 scopus 로고    scopus 로고
    • (accessed 10 December 2012)
    • American Academy of Orthopaedic Surgeons. Femur shaft fractures (broken thighbone), http://www.orthoinfo. aaos.org/topic.cfm?topic=A00521 (accessed 10 December 2012).
    • Femur Shaft Fractures (Broken Thighbone)
  • 2
    • 84863833135 scopus 로고    scopus 로고
    • US Department of Transportation, accessed 10 December 2012
    • US Department of Transportation. Transportation statistics annual report, http://www.bts.gov (2010, accessed 10 December 2012)
    • (2010) Transportation Statistics Annual Report
  • 3
    • 0034049783 scopus 로고    scopus 로고
    • Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem: A biomechanical study of 5 techniques
    • Dennis MG, Simon JA, Kummer FJ, et al. Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem: a biomechanical study of 5 techniques. J Arthroplasty 2000; 15: 523-528.
    • (2000) J Arthroplasty , vol.15 , pp. 523-528
    • Dennis, M.G.1    Simon, J.A.2    Kummer, F.J.3
  • 4
    • 0016832358 scopus 로고
    • Femoral fractures in conjunction with total hip replacement
    • Scott R, Turner R, Leitzes S, et al. Femoral fractures in conjunction with total hip replacement. J Bone Joint Surg Am 1975; 57: 494-501.
    • (1975) J Bone Joint Surg Am , vol.57 , pp. 494-501
    • Scott, R.1    Turner, R.2    Leitzes, S.3
  • 5
    • 0002111683 scopus 로고
    • Fractures beneath hip prostheses: A special indication for Parham bands and plating
    • Ogden WS and Rendall JF. Fractures beneath hip prostheses: a special indication for Parham bands and plating. Orthop Trans 1978; 2: 70-73.
    • (1978) Orthop Trans , vol.2 , pp. 70-73
    • Ogden, W.S.1    Rendall, J.F.2
  • 6
    • 43049099294 scopus 로고    scopus 로고
    • Biomechanical evaluation of periprosthetic femoral fracture fixation
    • Zdero R, Walker R, Waddell JP, et al. Biomechanical evaluation of periprosthetic femoral fracture fixation. J Bone Joint Surg Am 2008; 90: 1068-1077.
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 1068-1077
    • Zdero, R.1    Walker, R.2    Waddell, J.P.3
  • 8
    • 0019478398 scopus 로고
    • Toward a quantitative formulation of Wolff's law in trabecular bone
    • Cowin SC (ed.), New York: American Society of Mechanical Engineering
    • Hayes WC and Snyder BD. Toward a quantitative formulation of Wolff's law in trabecular bone. In: Cowin SC (ed.) Mechanical properties of bone. New York: American Society of Mechanical Engineering, 1981, pp.45-68.
    • (1981) Mechanical Properties of Bone , pp. 45-68
    • Hayes, W.C.1    Snyder, B.D.2
  • 9
    • 27644493651 scopus 로고    scopus 로고
    • Femoral strain changes after total hip arthroplasty patient-specific finite element analyses 12 years after operation
    • Lengsfeld M, Burchard R, Gunther D, et al. Femoral strain changes after total hip arthroplasty patient-specific finite element analyses 12 years after operation. Med Eng Phys 2005; 27: 649-654.
    • (2005) Med Eng Phys , vol.27 , pp. 649-654
    • Lengsfeld, M.1    Burchard, R.2    Gunther, D.3
  • 10
    • 0033062388 scopus 로고    scopus 로고
    • The merit of sintered PDLLA/TCP composites in management of bone fracture internal fixation
    • Lin FH, Chen TM, Lin CP, et al. The merit of sintered PDLLA/TCP composites in management of bone fracture internal fixation. Artif Organs 1999; 23: 186-194.
    • (1999) Artif Organs , vol.23 , pp. 186-194
    • Lin, F.H.1    Chen, T.M.2    Lin, C.P.3
  • 11
    • 0026512121 scopus 로고
    • Fixation of diaphyseal femoral osteotomy with self-reinforced biodegradable intramedullary implants: An experimental study on growing dogs
    • Miettinen H, MäkeläA, Rokkanen P, et al. Fixation of diaphyseal femoral osteotomy with self-reinforced biodegradable intramedullary implants: an experimental study on growing dogs. Clin Mater 1992; 9: 31-36.
    • (1992) Clin Mater , vol.9 , pp. 31-36
    • Miettinen, H.1    Mäkeläa Rokkanen, P.2
  • 13
    • 0025314925 scopus 로고
    • Carbon fibre composite bone plates: Development, evaluation, and early clinical experience
    • Ali MS, French TA, Hastings GW, et al. Carbon fibre composite bone plates: development, evaluation, and early clinical experience. J Bone Joint Surg Br 1990; 72: 586-591.
    • (1990) J Bone Joint Surg Br , vol.72 , pp. 586-591
    • Ali, M.S.1    French, T.A.2    Hastings, G.W.3
  • 14
    • 0020585520 scopus 로고
    • How stiff should semi-rigid fixation of the human tibia be? A clue to the answer
    • Tayton K and Bradley J. How stiff should semi-rigid fixation of the human tibia be? A clue to the answer. J Bone Joint Surg Br 1983; 65: 312-315.
    • (1983) J Bone Joint Surg Br , vol.65 , pp. 312-315
    • Tayton, K.1    Bradley, J.2
  • 15
    • 0019982649 scopus 로고
    • The use of semi-rigid carbon-fibre-reinforced plastic plates for fixation of human fractures. Results of preliminary trials
    • Tayton K, Johnson-Nurse C, McKibbin B, et al. The use of semi-rigid carbon-fibre-reinforced plastic plates for fixation of human fractures. Results of preliminary trials. J Bone Joint Surg Br 1982; 64: 105-111.
    • (1982) J Bone Joint Surg Br , vol.64 , pp. 105-111
    • Tayton, K.1    Johnson-Nurse, C.2    McKibbin, B.3
  • 16
    • 0028501057 scopus 로고
    • Aramidepoxy composite internal fixation plates: A pilot study
    • Cochran GVB, Palmieri VR and Zickel RE. Aramidepoxy composite internal fixation plates: a pilot study. Clin Biomech 1994; 9: 315-322.
    • (1994) Clin Biomech , vol.9 , pp. 315-322
    • Cochran, G.V.B.1    Palmieri, V.R.2    Zickel, R.E.3
  • 17
    • 0037411445 scopus 로고    scopus 로고
    • Performance study of braided carbon/PEEK composite compression bone plates
    • Fujihara K, Huang Z-M, Ramakrishna S, et al. Performance study of braided carbon/PEEK composite compression bone plates. Biomaterials 2003; 24: 2661-2667.
    • (2003) Biomaterials , vol.24 , pp. 2661-2667
    • Fujihara, K.1    Huang, Z.-M.2    Ramakrishna, S.3
  • 18
    • 1542268366 scopus 로고    scopus 로고
    • Feasibility of knitted carbon/PEEK composites for orthopedic bone plates
    • Fujihara K, Huang Z-M, Ramakrishna S, et al. Feasibility of knitted carbon/PEEK composites for orthopedic bone plates. Biomaterials 2004; 25: 3877-3885.
    • (2004) Biomaterials , vol.25 , pp. 3877-3885
    • Fujihara, K.1    Huang, Z.-M.2    Ramakrishna, S.3
  • 19
    • 13644281327 scopus 로고    scopus 로고
    • Stiffness and strength design of composite bone plates
    • Huang Z-M and Fujihara K. Stiffness and strength design of composite bone plates. Compos Sci Technol 2005; 65: 73-85.
    • (2005) Compos Sci Technol , vol.65 , pp. 73-85
    • Huang, Z.-M.1    Fujihara, K.2
  • 20
    • 0017289065 scopus 로고
    • Protection from stress in bone and its effects. Experiments with stainless steel and plastic plates in dogs
    • Tonino AJ, Davidson CL, Klopper PJ, et al. Protection from stress in bone and its effects. Experiments with stainless steel and plastic plates in dogs. J Bone Joint Surg Br 1976; 58: 107-113.
    • (1976) J Bone Joint Surg Br , vol.58 , pp. 107-113
    • Tonino, A.J.1    Davidson, C.L.2    Klopper, P.J.3
  • 21
    • 27744467587 scopus 로고    scopus 로고
    • Biomechanics of bone-fracture fixation by stiffness-graded plates in comparison with stainless-steel plates
    • Ganesh VK, Ramakrishna K and Ghista DN. Biomechanics of bone-fracture fixation by stiffness-graded plates in comparison with stainless-steel plates. Biomed Eng Online 2005; 4: 46.
    • (2005) Biomed Eng Online , vol.4 , pp. 46
    • Ganesh, V.K.1    Ramakrishna, K.2    Ghista, D.N.3
  • 22
    • 33746074064 scopus 로고    scopus 로고
    • Assessment of carbon fibre composite fracture fixation plate using finite element analysis
    • Saidpour SH. Assessment of carbon fibre composite fracture fixation plate using finite element analysis. Ann Biomed Eng 2006; 34: 1157-1163.
    • (2006) Ann Biomed Eng , vol.34 , pp. 1157-1163
    • Saidpour, S.H.1
  • 23
    • 73549123225 scopus 로고    scopus 로고
    • Bone remodeling in a new biomimetic polymer composite hip stem
    • Bougherara H, Bureau MN and Yahia LH. Bone remodeling in a new biomimetic polymer composite hip stem. J Biomed Mater Res A 2010; 92: 164-174.
    • (2010) J Biomed Mater Res A , vol.92 , pp. 164-174
    • Bougherara, H.1    Bureau, M.N.2    Yahia, L.H.3
  • 24
    • 84872677950 scopus 로고    scopus 로고
    • Biomechanical properties of an intact, injured, repaired, and healed femur: An experimental and computational study
    • Ebrahimi H, Rabinovich M, Vuleta V, et al. Biomechanical properties of an intact, injured, repaired, and healed femur: an experimental and computational study. J Mech Behav Biomed Mater 2012; 16: 121-135.
    • (2012) J Mech Behav Biomed Mater , vol.16 , pp. 121-135
    • Ebrahimi, H.1    Rabinovich, M.2    Vuleta, V.3
  • 25
    • 0035286601 scopus 로고    scopus 로고
    • Fixation of periprosthetic femoral shaft fractures: A biomechanical comparison of two techniques
    • Dennis MG, Simon JA, Kummer FJ, et al. Fixation of periprosthetic femoral shaft fractures: a biomechanical comparison of two techniques. J Orthop Trauma 2001; 15: 177-180.
    • (2001) J Orthop Trauma , vol.15 , pp. 177-180
    • Dennis, M.G.1    Simon, J.A.2    Kummer, F.J.3
  • 26
    • 80051856327 scopus 로고    scopus 로고
    • The biomechanics of plate repair of periprosthetic femur fractures near the tip of a total hip implant: The effect of cable-screw position
    • Dubov A, Kim SYR, Shah S, et al. The biomechanics of plate repair of periprosthetic femur fractures near the tip of a total hip implant: the effect of cable-screw position. Proc IMechE, Part H: J Engineering in Medicine 2011; 225: 857-865.
    • (2011) Proc IMechE, Part H: J Engineering in Medicine , vol.225 , pp. 857-865
    • Dubov, A.1    Kim, S.Y.R.2    Shah, S.3
  • 27
    • 33744503191 scopus 로고    scopus 로고
    • Fixation of periprosthetic femoral shaft fractures associated with cemented femoral stems: A biomechanical comparison of locked plating and conventional cable plates
    • Fulkerson E, Koval K, Preston CF, et al. Fixation of periprosthetic femoral shaft fractures associated with cemented femoral stems: a biomechanical comparison of locked plating and conventional cable plates. J Orthop Trauma 2006; 20: 89-93.
    • (2006) J Orthop Trauma , vol.20 , pp. 89-93
    • Fulkerson, E.1    Koval, K.2    Preston, C.F.3
  • 28
    • 80051848718 scopus 로고    scopus 로고
    • The biomechanics of plate fixation of periprosthetic femoral fractures near the tip of a total hip implant: Cables, screws, or both?
    • Shah S, Kim SYR, Dubov A, et al. The biomechanics of plate fixation of periprosthetic femoral fractures near the tip of a total hip implant: cables, screws, or both? Proc IMechE, Part H: J Engineering in Medicine 2011; 225: 845-856.
    • (2011) Proc IMechE, Part H: J Engineering in Medicine , vol.225 , pp. 845-856
    • Shah, S.1    Kim, S.Y.R.2    Dubov, A.3
  • 29
    • 84869498994 scopus 로고    scopus 로고
    • Biomechanical stress maps of an artificial femur obtained using a new infrared thermography technique validated by strain gages
    • Shah S, Bougherara H, Schemitsch EH, et al. Biomechanical stress maps of an artificial femur obtained using a new infrared thermography technique validated by strain gages. Med Eng Phys 2012; 34: 1496-1502.
    • (2012) Med Eng Phys , vol.34 , pp. 1496-1502
    • Shah, S.1    Bougherara, H.2    Schemitsch, E.H.3
  • 30
    • 34548281756 scopus 로고    scopus 로고
    • Biomechanics of bone
    • Mow VC and Huiskes R (eds), 3rd ed. Philadelphia, PA: Lippincott Williams and Wilkins
    • Huiskes R and van Rietbergen B. Biomechanics of bone. In: Mow VC and Huiskes R (eds) Basic orthopaedic biomechanics and mechano-biology. 3rd ed. Philadelphia, PA: Lippincott Williams and Wilkins, 2005, pp.123-179.
    • (2005) Basic Orthopaedic Biomechanics and Mechano-biology , pp. 123-179
    • Huiskes, R.1    Van Rietbergen, B.2
  • 32
    • 0002668116 scopus 로고
    • Introduction
    • Hench LL and Wilson J (eds), Singapore: World Scientific
    • Hench LL and Wilson J. Introduction. In: Hench LL and Wilson J (eds) An introduction to bioceramics. Singapore: World Scientific, 1993, pp.1-24.
    • (1993) An Introduction to Bioceramics , pp. 1-24
    • Hench, L.L.1    Wilson, J.2
  • 33
    • 0023869835 scopus 로고
    • Telemetric force measurements across the hip after total arthroplasty
    • Davy DT, Kotzar GM, Brown RH, et al. Telemetric force measurements across the hip after total arthroplasty. J Bone Joint Surg Am 1988; 70: 45-50.
    • (1988) J Bone Joint Surg Am , vol.70 , pp. 45-50
    • Davy, D.T.1    Kotzar, G.M.2    Brown, R.H.3
  • 34
    • 0030951051 scopus 로고    scopus 로고
    • Composition and mechanical properties of cancellous bone from the femoral head of patients with osteoporosis or osteoarthritis
    • Li B and Aspden RM. Composition and mechanical properties of cancellous bone from the femoral head of patients with osteoporosis or osteoarthritis. J Bone Miner Res 1997; 12: 641-651.
    • (1997) J Bone Miner Res , vol.12 , pp. 641-651
    • Li, B.1    Aspden, R.M.2
  • 35
    • 34248189246 scopus 로고    scopus 로고
    • The biomechanics of human femurs in axial and torsional loading: Comparison of finite element analysis, human cadaveric femurs, and synthetic femurs
    • Papini M, Zdero R, Schemitsch EH, et al. The biomechanics of human femurs in axial and torsional loading: comparison of finite element analysis, human cadaveric femurs, and synthetic femurs. J Biomech Eng 2007; 129: 12-19.
    • (2007) J Biomech Eng , vol.129 , pp. 12-19
    • Papini, M.1    Zdero, R.2    Schemitsch, E.H.3
  • 36
    • 55549101580 scopus 로고    scopus 로고
    • Femoral neck fracture following hip resurfacing: The effect of alignment of the femoral component
    • Davis ET, Olsen M, Zdero R, et al. Femoral neck fracture following hip resurfacing: the effect of alignment of the femoral component. J Bone Joint Surg Br 2008; 90: 1522-1527.
    • (2008) J Bone Joint Surg Br , vol.90 , pp. 1522-1527
    • Davis, E.T.1    Olsen, M.2    Zdero, R.3
  • 37
    • 67049161248 scopus 로고    scopus 로고
    • A biomechanical and finite element analysis of femoral neck notching during hip resurfacing
    • Davis ET, Olsen M, Zdero R, et al. A biomechanical and finite element analysis of femoral neck notching during hip resurfacing. J Biomech Eng 2009; 131: 041002-1-041002-8.
    • (2009) J Biomech Eng , vol.131 , pp. 0410021-0410028
    • Davis, E.T.1    Olsen, M.2    Zdero, R.3
  • 38
    • 0035719080 scopus 로고    scopus 로고
    • Thermoelastic femoral stress imaging for experimental evaluation of hip prosthesis design
    • Hyodo K, Inomoto M, Ma WW, et al. Thermoelastic femoral stress imaging for experimental evaluation of hip prosthesis design. JSME Int J C: Mech Sy 2001; 44: 1065-1071.
    • (2001) JSME Int J C: Mech Sy , vol.44 , pp. 1065-1071
    • Hyodo, K.1    Inomoto, M.2    Ma, W.W.3
  • 39
    • 84896764436 scopus 로고    scopus 로고
    • Vashon, WA
    • Johnson A. Sawbones, Vashon, WA, http://www.sawbones. com, 2011.
    • (2011) Sawbones
    • Johnson, A.1
  • 41
    • 0025786787 scopus 로고
    • Thermographic stress analysis in cortical bone
    • Vanderby R Jr and Kohles SS. Thermographic stress analysis in cortical bone. J Biomech Eng 1991; 113: 418-422.
    • (1991) J Biomech Eng , vol.113 , pp. 418-422
    • Vanderby Jr., R.1    Kohles, S.S.2
  • 42
    • 84896751502 scopus 로고    scopus 로고
    • (accessed 10 July 2013)
    • MatWeb. 316L Stainless Steel, http://www.matweb.com/ search/DataSheet. aspx?MatGUID= 66a15d609a3f4c829cb6ad08f0dafc01&ckck=1 (accessed 10 July 2013).
    • 316L Stainless Steel
  • 43
    • 33244486341 scopus 로고    scopus 로고
    • A critical review of infrared thermography as a method for non-destructive evaluation of FRP rehabilitated structures
    • Ghosh KK and Karbhari VM. A critical review of infrared thermography as a method for non-destructive evaluation of FRP rehabilitated structures. Int J Mater Prod Tec 2006; 25: 241-266.
    • (2006) Int J Mater Prod Tec , vol.25 , pp. 241-266
    • Ghosh, K.K.1    Karbhari, V.M.2
  • 44
    • 43449132407 scopus 로고    scopus 로고
    • Cyclic loading of periprosthetic fracture fixation constructs
    • Talbot M, Zdero R and Schemitsch EH. Cyclic loading of periprosthetic fracture fixation constructs. J Trauma 2008; 64: 1308-1312.
    • (2008) J Trauma , vol.64 , pp. 1308-1312
    • Talbot, M.1    Zdero, R.2    Schemitsch, E.H.3
  • 45
    • 0026864111 scopus 로고
    • Finite-element modelling of femoral shaft fracture fixation techniques post total hip arthroplasty
    • Mihalko WM, Beaudoin AJ, Cardea JA, et al. Finite-element modelling of femoral shaft fracture fixation techniques post total hip arthroplasty. J Biomech 1992; 25: 469-476.
    • (1992) J Biomech , vol.25 , pp. 469-476
    • Mihalko, W.M.1    Beaudoin, A.J.2    Cardea, J.A.3
  • 46
    • 33947603532 scopus 로고    scopus 로고
    • Thermoelastic stress analysis by means of a standard thermocamera
    • Zanetti EM, Musso SS and Audenino AL. Thermoelastic stress analysis by means of a standard thermocamera. Exp Techniques 2007; 31(2): 42-50.
    • (2007) Exp Techniques , vol.31 , Issue.2 , pp. 42-50
    • Zanetti, E.M.1    Musso, S.S.2    Audenino, A.L.3
  • 47
    • 0031126508 scopus 로고    scopus 로고
    • Thermographic strain analysis of the proximal canine femur
    • Kohles SS and Vanderby R Jr. Thermographic strain analysis of the proximal canine femur. Med Eng Phys 1997; 19: 262-266.
    • (1997) Med Eng Phys , vol.19 , pp. 262-266
    • Kohles, S.S.1    Vanderby Jr., R.2
  • 48
    • 79960898876 scopus 로고    scopus 로고
    • A preliminary biomechanical assessment of a polymer composite hip implant using an infrared thermography technique validated by strain gage measurements
    • Bougherara H, Rahim E, Shah S, et al. A preliminary biomechanical assessment of a polymer composite hip implant using an infrared thermography technique validated by strain gage measurements. J Biomech Eng 2011; 133: 074503-1-074503-6.
    • (2011) J Biomech Eng , vol.133 , pp. 0745031-0745036
    • Bougherara, H.1    Rahim, E.2    Shah, S.3
  • 49
    • 0022661701 scopus 로고
    • Applications of thermoelastic stress analysis
    • Harwood N and Cummings WM. Applications of thermoelastic stress analysis. Strain 1986; 22(1): 7-12.
    • (1986) Strain , vol.22 , Issue.1 , pp. 7-12
    • Harwood, N.1    Cummings, W.M.2
  • 50
    • 0023510231 scopus 로고
    • Adaptive bone-remodeling theory applied to prosthetic-design analysis
    • Huiskes R, Weinans H, Grootenboer HJ, et al. Adaptive bone-remodeling theory applied to prosthetic-design analysis. J Biomech 1987; 20: 1135-1150.
    • (1987) J Biomech , vol.20 , pp. 1135-1150
    • Huiskes, R.1    Weinans, H.2    Grootenboer, H.J.3
  • 51
    • 65249127992 scopus 로고    scopus 로고
    • The biomechanics of the T2 femoral nailing system: A comparison of synthetic femurs with finite element analysis
    • Bougherara H, Zdero R, Miric M, et al. The biomechanics of the T2 femoral nailing system: a comparison of synthetic femurs with finite element analysis. Proc IMechE, Part H: J Engineering in Medicine 2009; 223: 303-314.
    • (2009) Proc IMechE, Part H: J Engineering in Medicine , vol.223 , pp. 303-314
    • Bougherara, H.1    Zdero, R.2    Miric, M.3
  • 52
    • 38749090538 scopus 로고    scopus 로고
    • Fixation of long bone segmental defects: A biomechanical study
    • Talbot M, Zdero R, Garneau D, et al. Fixation of long bone segmental defects: a biomechanical study. Injury 2008; 39: 181-186.
    • (2008) Injury , vol.39 , pp. 181-186
    • Talbot, M.1    Zdero, R.2    Garneau, D.3
  • 53
    • 78650929785 scopus 로고    scopus 로고
    • A preliminary biomechanical study of a novel carbon-fibre hip implant versus standard metallic hip implants
    • Bougherara H, Zdero R, Dubov A, et al. A preliminary biomechanical study of a novel carbon-fibre hip implant versus standard metallic hip implants. Med Eng Phys 2011; 33: 121-128.
    • (2011) Med Eng Phys , vol.33 , pp. 121-128
    • Bougherara, H.1    Zdero, R.2    Dubov, A.3
  • 54
    • 55549093737 scopus 로고    scopus 로고
    • Evaluation of bone plate with low-stiffness material in terms of stress distribution
    • Benli S, Aksoy S, Havitcioglu H, et al. Evaluation of bone plate with low-stiffness material in terms of stress distribution. J Biomech 2008; 41: 3229-3235.
    • (2008) J Biomech , vol.41 , pp. 3229-3235
    • Benli, S.1    Aksoy, S.2    Havitcioglu, H.3
  • 55
    • 78049486565 scopus 로고    scopus 로고
    • The biomechanics of a validated finite element model of stress shielding in a novel hybrid total knee replacement
    • Bougherara H, Zdero R, Mahboob Z, et al. The biomechanics of a validated finite element model of stress shielding in a novel hybrid total knee replacement. Proc IMechE, Part H: J Engineering in Medicine 2010; 224: 1209-1219.
    • (2010) Proc IMechE, Part H: J Engineering in Medicine , vol.224 , pp. 1209-1219
    • Bougherara, H.1    Zdero, R.2    Mahboob, Z.3
  • 56
    • 34247152954 scopus 로고    scopus 로고
    • Methods of operative fixation of the acromioclavicular joint: A biomechanical comparison
    • McConnell AJ, Yoo DJ, Zdero R, et al. Methods of operative fixation of the acromioclavicular joint: a biomechanical comparison. J Orthop Trauma 2007; 21: 248-253.
    • (2007) J Orthop Trauma , vol.21 , pp. 248-253
    • McConnell, A.J.1    Yoo, D.J.2    Zdero, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.