-
1
-
-
0028265272
-
The laryngeal mask airway in pediatric patients: Factors affecting ease of use during insertion and emergence
-
B. O'Neill, J.J. Templeton, L. Caramico, and M.S. Schreiner The laryngeal mask airway in pediatric patients: factors affecting ease of use during insertion and emergence Anesth Analg 78 4 1994 659 662
-
(1994)
Anesth Analg
, vol.78
, Issue.4
, pp. 659-662
-
-
O'Neill, B.1
Templeton, J.J.2
Caramico, L.3
Schreiner, M.S.4
-
2
-
-
49849091610
-
Randomized trial of endotracheal tube versus laryngeal mask airway in simulated prehospital pediatric arrest
-
L. Chen, and A.L. Hsiao Randomized trial of endotracheal tube versus laryngeal mask airway in simulated prehospital pediatric arrest Pediatrics 122 2 2008 e294 e297
-
(2008)
Pediatrics
, vol.122
, Issue.2
-
-
Chen, L.1
Hsiao, A.L.2
-
3
-
-
0742270779
-
Laryngeal mask airway control versus endotracheal intubation by medical personnel wearing protective gear
-
R. Ben-Abraham, and A.A. Weinbroum Laryngeal mask airway control versus endotracheal intubation by medical personnel wearing protective gear Am J Emerg Med 22 1 2004 24 26
-
(2004)
Am J Emerg Med
, vol.22
, Issue.1
, pp. 24-26
-
-
Ben-Abraham, R.1
Weinbroum, A.A.2
-
4
-
-
0028798230
-
Laryngeal mask airway for emergency medicine
-
J. Brimacombe Laryngeal mask airway for emergency medicine Am J Emerg Med 13 1 1995 111 112
-
(1995)
Am J Emerg Med
, vol.13
, Issue.1
, pp. 111-112
-
-
Brimacombe, J.1
-
5
-
-
84873660011
-
Comparison of 2 cuff inflation methods before insertion of laryngeal mask airway for safe use without cuff manometer in children
-
M.S. Kim, S.J. Bai, J.T. Oh, S.M. Youm, and J.R. Lee Comparison of 2 cuff inflation methods before insertion of laryngeal mask airway for safe use without cuff manometer in children Am J Emerg Med 31 2 2013 346 352
-
(2013)
Am J Emerg Med
, vol.31
, Issue.2
, pp. 346-352
-
-
Kim, M.S.1
Bai, S.J.2
Oh, J.T.3
Youm, S.M.4
Lee, J.R.5
-
6
-
-
0035659476
-
Prehospital and resuscitative airway care: Should the gold standard be reassessed?
-
J.D. Nolan Prehospital and resuscitative airway care: should the gold standard be reassessed? Curr Opin Crit Care 7 6 2001 413 421
-
(2001)
Curr Opin Crit Care
, vol.7
, Issue.6
, pp. 413-421
-
-
Nolan, J.D.1
-
7
-
-
12344275881
-
Securing the prehospital airway: A comparison of laryngeal mask insertion and endotracheal intubation by UK paramedics
-
C.D. Deakin, R. Peters, P. Tomlinson, and M. Cassidy Securing the prehospital airway: a comparison of laryngeal mask insertion and endotracheal intubation by UK paramedics Emerg Med J 22 1 2005 64 67
-
(2005)
Emerg Med J
, vol.22
, Issue.1
, pp. 64-67
-
-
Deakin, C.D.1
Peters, R.2
Tomlinson, P.3
Cassidy, M.4
-
8
-
-
52049110288
-
Choosing the correct laryngeal mask airway sizes and cuff inflation volumes in pediatric patients
-
A.M. Ho, M.K. Karmakar, and P.W. Dion Choosing the correct laryngeal mask airway sizes and cuff inflation volumes in pediatric patients J Emerg Med 35 3 2008 299 300
-
(2008)
J Emerg Med
, vol.35
, Issue.3
, pp. 299-300
-
-
Ho, A.M.1
Karmakar, M.K.2
Dion, P.W.3
-
9
-
-
0028934306
-
Laryngeal mask airway: A more successful method of insertion
-
B.F. Matta, D.S. Marsh, and M. Nevin Laryngeal mask airway: a more successful method of insertion J Clin Anesth 7 2 1995 132 135
-
(1995)
J Clin Anesth
, vol.7
, Issue.2
, pp. 132-135
-
-
Matta, B.F.1
Marsh, D.S.2
Nevin, M.3
-
10
-
-
0030066299
-
A more successful method for laryngeal mask airway insertion?
-
J.R. Brimacombe A more successful method for laryngeal mask airway insertion? J Clin Anesth 8 1 1996 82 83
-
(1996)
J Clin Anesth
, vol.8
, Issue.1
, pp. 82-83
-
-
Brimacombe, J.R.1
-
11
-
-
77649165501
-
Use of manometry for laryngeal mask airway reduces postoperative pharyngolaryngeal adverse events: A prospective, randomized trial
-
E. Seet, F. Yousaf, S. Gupta, R. Subramanyam, D.T. Wong, and F. Chung Use of manometry for laryngeal mask airway reduces postoperative pharyngolaryngeal adverse events: a prospective, randomized trial Anesthesiology 112 3 2010 652 657
-
(2010)
Anesthesiology
, vol.112
, Issue.3
, pp. 652-657
-
-
Seet, E.1
Yousaf, F.2
Gupta, S.3
Subramanyam, R.4
Wong, D.T.5
Chung, F.6
-
12
-
-
51349105384
-
Lower cuff pressures improve the seal of pediatric laryngeal mask airways
-
A. Licina, N.A. Chambers, B. Hullett, T.O. Erb, and B.S. von Ungern-Sternberg Lower cuff pressures improve the seal of pediatric laryngeal mask airways Paediatr Anaesth 18 10 2008 952 956
-
(2008)
Paediatr Anaesth
, vol.18
, Issue.10
, pp. 952-956
-
-
Licina, A.1
Chambers, N.A.2
Hullett, B.3
Erb, T.O.4
Von Ungern-Sternberg, B.S.5
-
13
-
-
84856212837
-
Evolution of the extraglottic airway: A review of its history, applications, and practical tips for success
-
M.R. Hernandez, P.A. Klock Jr., and A. Ovassapian Evolution of the extraglottic airway: a review of its history, applications, and practical tips for success Anesth Analg 114 2 2012 349 368
-
(2012)
Anesth Analg
, vol.114
, Issue.2
, pp. 349-368
-
-
Hernandez, M.R.1
Klock, Jr.P.A.2
Ovassapian, A.3
-
14
-
-
77949291302
-
Reduced air leakage by adjusting the cuff pressure in pediatric laryngeal mask airways during spontaneous ventilation
-
L. Hockings, M. Heaney, N.A. Chambers, T.O. Erb, and B.S. von Ungern-Sternberg Reduced air leakage by adjusting the cuff pressure in pediatric laryngeal mask airways during spontaneous ventilation Paediatr Anaesth 20 4 2010 313 317
-
(2010)
Paediatr Anaesth
, vol.20
, Issue.4
, pp. 313-317
-
-
Hockings, L.1
Heaney, M.2
Chambers, N.A.3
Erb, T.O.4
Von Ungern-Sternberg, B.S.5
-
15
-
-
0033029578
-
Calculated vs measured pharyngeal mucosal pressures with the laryngeal mask airway during cuff inflation: Assessment of four locations
-
C. Keller, J. Brimacombe, and A. Benzer Calculated vs measured pharyngeal mucosal pressures with the laryngeal mask airway during cuff inflation: assessment of four locations Br J Anaesth 82 3 1999 399 401
-
(1999)
Br J Anaesth
, vol.82
, Issue.3
, pp. 399-401
-
-
Keller, C.1
Brimacombe, J.2
Benzer, A.3
-
16
-
-
66049087862
-
Pressure volume curves of paediatric laryngeal mask airways
-
C.J. Wallace, N.A. Chambers, T.O. Erb, and B.S. von Ungern-Sternberg Pressure volume curves of paediatric laryngeal mask airways Anaesthesia 64 5 2009 527 531
-
(2009)
Anaesthesia
, vol.64
, Issue.5
, pp. 527-531
-
-
Wallace, C.J.1
Chambers, N.A.2
Erb, T.O.3
Von Ungern-Sternberg, B.S.4
-
17
-
-
0031818717
-
Influence of cuff volume on oropharyngeal leak pressure and fibreoptic position with the laryngeal mask airway
-
C. Keller, F. Puhringer, and J.R. Brimacombe Influence of cuff volume on oropharyngeal leak pressure and fibreoptic position with the laryngeal mask airway Br J Anaesth 81 2 1998 186 187
-
(1998)
Br J Anaesth
, vol.81
, Issue.2
, pp. 186-187
-
-
Keller, C.1
Puhringer, F.2
Brimacombe, J.R.3
-
18
-
-
14644394877
-
Using atmospheric pressure to inflate the cuff of the Portex Laryngeal Mask
-
B. Al-Shaikh, M. George William, and A.A. Van Zundert Using atmospheric pressure to inflate the cuff of the Portex Laryngeal Mask Anaesthesia 60 3 2005 296 297
-
(2005)
Anaesthesia
, vol.60
, Issue.3
, pp. 296-297
-
-
Al-Shaikh, B.1
George William, M.2
Van Zundert, A.A.3
-
19
-
-
84862793214
-
A randomised trial comparing the i-gel (TM) with the LMA Classic (TM) in children
-
J.R. Lee, M.S. Kim, J.T. Kim, H.J. Byon, Y.H. Park, and H.S. Kim et al. A randomised trial comparing the i-gel (TM) with the LMA Classic (TM) in children Anaesthesia 67 6 2012 606 611
-
(2012)
Anaesthesia
, vol.67
, Issue.6
, pp. 606-611
-
-
Lee, J.R.1
Kim, M.S.2
Kim, J.T.3
Byon, H.J.4
Park, Y.H.5
Kim, H.S.6
-
20
-
-
79959491828
-
Performance of the pediatric-sized i-gel compared with the Ambu AuraOnce laryngeal mask in anesthetized and ventilated children
-
L.G. Theiler, M. Kleine-Brueggeney, B. Luepold, F. Stucki, S. Seiler, and N. Urwyler et al. Performance of the pediatric-sized i-gel compared with the Ambu AuraOnce laryngeal mask in anesthetized and ventilated children Anesthesiology 115 1 2011 102 110
-
(2011)
Anesthesiology
, vol.115
, Issue.1
, pp. 102-110
-
-
Theiler, L.G.1
Kleine-Brueggeney, M.2
Luepold, B.3
Stucki, F.4
Seiler, S.5
Urwyler, N.6
-
21
-
-
67649616881
-
Comparison of different techniques of laryngeal mask placement in children
-
B. Ghai, and J. Wig Comparison of different techniques of laryngeal mask placement in children Curr Opin Anaesthesiol 22 3 2009 400 404
-
(2009)
Curr Opin Anaesthesiol
, vol.22
, Issue.3
, pp. 400-404
-
-
Ghai, B.1
Wig, J.2
-
22
-
-
65349195540
-
Impact of laryngeal mask airway cuff pressures on the incidence of sore throat in children
-
J.G. Wong, M. Heaney, N.A. Chambers, T.O. Erb, and B.S. von Ungern-Sternberg Impact of laryngeal mask airway cuff pressures on the incidence of sore throat in children Paediatr Anaesth 19 5 2009 464 469
-
(2009)
Paediatr Anaesth
, vol.19
, Issue.5
, pp. 464-469
-
-
Wong, J.G.1
Heaney, M.2
Chambers, N.A.3
Erb, T.O.4
Von Ungern-Sternberg, B.S.5
-
23
-
-
84863555293
-
A simple method of partial inflation of the LMA cuff before insertion in children to allow cuff pressure without adjustment after insertion
-
B.E. Moon, M.S. Kim, and J.R. Lee A simple method of partial inflation of the LMA cuff before insertion in children to allow cuff pressure without adjustment after insertion Korean J Anesthesiol 62 6 2012 524 528
-
(2012)
Korean J Anesthesiol
, vol.62
, Issue.6
, pp. 524-528
-
-
Moon, B.E.1
Kim, M.S.2
Lee, J.R.3
-
24
-
-
33645234921
-
Cuff filling volumes and pressures in pediatric laryngeal mask airways
-
P. Maino, A. Dullenkopf, C. Keller, V. Bernet-Buettiker, and M. Weiss Cuff filling volumes and pressures in pediatric laryngeal mask airways Paediatr Anaesth 16 1 2006 25 30
-
(2006)
Paediatr Anaesth
, vol.16
, Issue.1
, pp. 25-30
-
-
Maino, P.1
Dullenkopf, A.2
Keller, C.3
Bernet-Buettiker, V.4
Weiss, M.5
-
25
-
-
79960448763
-
Oropharyngeal leak pressure with the laryngeal mask airway Supreme at different intracuff pressures: A randomized controlled trial
-
L. Zhang, E. Seet, V. Mehta, R. Subramanyam, S.P. Ankichetty, and D.T. Wong et al. Oropharyngeal leak pressure with the laryngeal mask airway Supreme at different intracuff pressures: a randomized controlled trial Can J Anaesth 58 7 2011 624 629
-
(2011)
Can J Anaesth
, vol.58
, Issue.7
, pp. 624-629
-
-
Zhang, L.1
Seet, E.2
Mehta, V.3
Subramanyam, R.4
Ankichetty, S.P.5
Wong, D.T.6
|