메뉴 건너뛰기




Volumn 22, Issue 6, 2013, Pages 1327-1338

Design considerations for CMOS-integrated hall-effect magnetic bead detectors for biosensor applications

Author keywords

Assay; Biosensor; CMOS; Hall effect; Magnetic bead; Magnetic particle

Indexed keywords

BIOLOGICAL ASSAYS; BIOSENSOR APPLICATIONS; DESIGN CONSIDERATIONS; DESIGN METHODOLOGY; HALL SENSOR ARRAY; HALL-EFFECT SENSORS; MAGNETIC BEADS; MAGNETIC PARTICLE;

EID: 84896736657     PISSN: 10577157     EISSN: None     Source Type: Journal    
DOI: 10.1109/JMEMS.2013.2259615     Document Type: Article
Times cited : (28)

References (31)
  • 1
    • 56549083018 scopus 로고    scopus 로고
    • Innovations in optical microfluidic technologies for point-of-care diagnostics
    • Dec.
    • F. Myers and L. Lee, "Innovations in optical microfluidic technologies for point-of-care diagnostics," Lab Chip, vol. 8, no. 12, pp. 2015-2031, Dec. 2008.
    • (2008) Lab Chip , vol.8 , Issue.12 , pp. 2015-2031
    • Myers, F.1    Lee, L.2
  • 3
    • 77949716981 scopus 로고    scopus 로고
    • On-chip magnetic separation of superparamagnetic beads for integrated molecular analysis
    • Mar.
    • O. Florescu, K. Wang, P. Au, J. Tang, E. Harris, P. R. Beatty, and B. E. Boser, "On-chip magnetic separation of superparamagnetic beads for integrated molecular analysis," J. Appl. Phys., vol. 107, no. 5, p. 054702, Mar. 2010.
    • (2010) J. Appl. Phys. , vol.107 , Issue.5 , pp. 054702
    • Florescu, O.1    Wang, K.2    Au, P.3    Tang, J.4    Harris, E.5    Beatty, P.R.6    Boser, B.E.7
  • 4
    • 80052253331 scopus 로고    scopus 로고
    • Integrated microfluidic processor for solid phase capture immunoassays
    • Jul.
    • J. Kim, E. Jensen, M. Megens, B. E. Boser, and R. Mathies, "Integrated microfluidic processor for solid phase capture immunoassays," Lab Chip, vol. 11, no. 18, pp. 3106-3112, Jul. 2011.
    • (2011) Lab Chip , vol.11 , Issue.18 , pp. 3106-3112
    • Kim, J.1    Jensen, E.2    Megens, M.3    Boser, B.E.4    Mathies, R.5
  • 6
    • 0038313051 scopus 로고    scopus 로고
    • Biodetection using magnetically labeled biomolecules and arrays of spin valve sensors
    • May
    • H. Ferreira, D. Graham, P. Freitas, and J. Cabral, "Biodetection using magnetically labeled biomolecules and arrays of spin valve sensors," J. Appl. Phys., vol. 93, no. 10, pp. 7281-7286, May 2003.
    • (2003) J. Appl. Phys. , vol.93 , Issue.10 , pp. 7281-7286
    • Ferreira, H.1    Graham, D.2    Freitas, P.3    Cabral, J.4
  • 7
    • 0242364773 scopus 로고    scopus 로고
    • Design and performance of GMR sensors for the detection of magnetic microbeads in biosensors
    • Nov.
    • J. Rife, M. Miller, P. Sheehan, C. Tamanaha, M. Tondra, and L. Whitman, "Design and performance of GMR sensors for the detection of magnetic microbeads in biosensors," Sensor Actuators A-, Phys., vol. 107, no. 3, pp. 209-218, Nov. 2003.
    • (2003) Sensor Actuators A-, Phys. , vol.107 , Issue.3 , pp. 209-218
    • Rife, J.1    Miller, M.2    Sheehan, P.3    Tamanaha, C.4    Tondra, M.5    Whitman, L.6
  • 9
    • 70349268229 scopus 로고    scopus 로고
    • A frequency-shift CMOS magnetic biosensor array with single-bead sensitivity and no external magnet
    • Feb.
    • H. Wang, Y. Chen, A. Hassibi, A. Scherer, and A. Hajimiri, "A frequency-shift CMOS magnetic biosensor array with single-bead sensitivity and no external magnet," in Proc. ISSCC Dig. Tech. Papers, Feb. 2009, p. 438.
    • (2009) Proc. ISSCC Dig. Tech. Papers , pp. 438
    • Wang, H.1    Chen, Y.2    Hassibi, A.3    Scherer, A.4    Hajimiri, A.5
  • 10
    • 79956052903 scopus 로고    scopus 로고
    • Detection of a single magnetic microbead using a miniaturized silicon Hall sensor
    • Jun.
    • P. Besse, G. Boero, M. Demierre, V. Pott, and R. Popovic, "Detection of a single magnetic microbead using a miniaturized silicon Hall sensor," Appl. Phys. Lett. vol. 80, no. 22, pp. 4199-4201, Jun. 2002.
    • (2002) Appl. Phys. Lett. , vol.80 , Issue.22 , pp. 4199-4201
    • Besse, P.1    Boero, G.2    Demierre, M.3    Pott, V.4    Popovic, R.5
  • 11
    • 24944480817 scopus 로고    scopus 로고
    • Detection of single magnetic bead for biological applications using an InAs quantum-well micro-Hall sensor
    • May
    • G. Mihajlovic, P. Xiong, S. von Molnár, K. Ohtani, H. Ohno, M. Field, and G. Sullivan, "Detection of single magnetic bead for biological applications using an InAs quantum-well micro-Hall sensor," Appl. Phys. Lett., vol. 87, no. 11, p. 112502, May 2009.
    • (2009) Appl. Phys. Lett. , vol.87 , Issue.11 , pp. 112502
    • Mihajlovic, G.1    Xiong, P.2    Von Molnár, S.3    Ohtani, K.4    Ohno, H.5    Field, M.6    Sullivan, G.7
  • 12
    • 33847367032 scopus 로고    scopus 로고
    • High efficiency Hall effect micro-biosensor platform for detection of magnetically labeled biomolecules
    • DOI 10.1016/j.bios.2006.09.021, PII S0956566306004544, Selected Papers from the Ninth World Congress On Biosensors
    • A. Sandhu, Y. Kumagai, A. Lapicki, S. Sakamoto, M. Abe, and H. Handa. "High efficiency Hall effect micro-biosensor platform for detection of magnetically labeled biomolecules," Biosens. Bioelectron., vol. 22, no. 9, pp. 2115-2120, Sep. 2006. (Pubitemid 46349655)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.9-10 , pp. 2115-2120
    • Sandhu, A.1    Kumagai, Y.2    Lapicki, A.3    Sakamoto, S.4    Abe, M.5    Handa, H.6
  • 13
    • 33746889824 scopus 로고    scopus 로고
    • A novel magnetic bead bioassay platform using a microchip-based sensor for infectious disease diagnosis
    • DOI 10.1016/j.jim.2006.05.006, PII S0022175906001372
    • T. Aytur, J. Foley, M. Anwar, B. E. Boser, E. Harris, and P. R. Beatty, "A novel magnetic bead bioassay platform using microchip-based sensors for infectious disease diagnosis," J. Immunol Meth., vol. 314, no. 1-2, pp. 21-29, Jul. 2006. (Pubitemid 44189423)
    • (2006) Journal of Immunological Methods , vol.314 , Issue.1-2 , pp. 21-29
    • Aytur, T.1    Foley, J.2    Anwar, M.3    Boser, B.4    Harris, E.5    Beatty, P.R.6
  • 14
    • 40149100163 scopus 로고    scopus 로고
    • Fully integrated detection of single magnetic beads in complementary metal-oxide-semiconductor
    • Feb.
    • O. Florescu, M. Mattman, and B. E. Boser, "Fully integrated detection of single magnetic beads in complementary metal-oxide-semiconductor, " J. Appl. Phys., vol. 103, no. 4, p. 046101, Feb. 2008.
    • (2008) J. Appl. Phys. , vol.103 , Issue.4 , pp. 046101
    • Florescu, O.1    Mattman, M.2    Boser, B.E.3
  • 16
    • 80053509292 scopus 로고    scopus 로고
    • A CMOS Hall-Effect sensor for the characterization and detection of magnetic nanoparticles for biomedical applications
    • Oct.
    • P. Liu, K. Skucha, M. Megens, and B. E. Boser, "A CMOS Hall-Effect sensor for the characterization and detection of magnetic nanoparticles for biomedical applications," IEEE Trans. Magn.,vol. 47, no. 10, pp. 3449-3451, Oct. 2011.
    • (2011) IEEE Trans. Magn. , vol.47 , Issue.10 , pp. 3449-3451
    • Liu, P.1    Skucha, K.2    Megens, M.3    Boser, B.E.4
  • 19
    • 84872102776 scopus 로고    scopus 로고
    • A 10K pixel CMOS Hall sensor array with baseline suppression and parallel readout for immunoassays
    • Jan.
    • S. Gambini, K. Skucha, P. Liu, J. Kim, and R. Krigel, "A 10K pixel CMOS Hall sensor array with baseline suppression and parallel readout for immunoassays," IEEE J. Solid-State Circuits, vol. 48, no. 1, pp. 302-317, Jan. 2013.
    • (2013) IEEE J. Solid-State Circuits , vol.48 , Issue.1 , pp. 302-317
    • Gambini, S.1    Skucha, K.2    Liu, P.3    Kim, J.4    Krigel, R.5
  • 21
    • 33644952039 scopus 로고    scopus 로고
    • Solid-phase and bead-based cytokine immunoassay: A comparison
    • Mar.
    • W. Jager, G. T. Rijkers, "Solid-phase and bead-based cytokine immunoassay: A comparison," Methods, vol. 38, no. 4, pp. 294-303, Mar. 2006.
    • (2006) Methods , vol.38 , Issue.4 , pp. 294-303
    • Jager, W.1    Rijkers, G.T.2
  • 23
    • 21444438484 scopus 로고    scopus 로고
    • Biological shot-noise and quantum-limited signal-to-noise ratio in affinity-based biosensors
    • Apr.
    • A. Hassibi, S. Zahedi, R. Navid, R. W. Dutton, and T. H. Lee, "Biological shot-noise and quantum-limited signal-to-noise ratio in affinity-based biosensors," J. Appl. Phys., vol. 97, no. 8, p. 084701, Apr. 2005.
    • (2005) J. Appl. Phys. , vol.97 , Issue.8 , pp. 084701
    • Hassibi, A.1    Zahedi, S.2    Navid, R.3    Dutton, R.W.4    Lee, T.H.5
  • 24
    • 1842422553 scopus 로고    scopus 로고
    • Incorporating fluorescent dyes and quantum dots into magnetic microbeads for immunoassays
    • S. P. Mulvaney, H.Mattoussi, and L. J. Whitman, "Incorporating fluorescent dyes and quantum dots into magnetic microbeads for immunoassays," BioTechnology, vol. 36, no. 4, pp. 602-609, Apr. 2004. (Pubitemid 38451644)
    • (2004) BioTechniques , vol.36 , Issue.4 , pp. 602-609
    • Mulvaney, S.P.1    Mattoussi, H.M.2    Whitman, L.J.3
  • 25
    • 0033180138 scopus 로고    scopus 로고
    • High sensitivity immunoassays using particulate fluorescent labels
    • DOI 10.1006/abio.1999.4155
    • M. Hall, I. Kazakova, and Y. Yao, "High sensitivity immunoassays using particulate fluorescent labels," Anal. Biochem., vol. 272, no. 2, pp. 165-170, Aug. 1999. (Pubitemid 29364979)
    • (1999) Analytical Biochemistry , vol.272 , Issue.2 , pp. 165-170
    • Hall, M.1    Kazakova, I.2    Yao, Y.-M.3
  • 26
    • 33744810647 scopus 로고    scopus 로고
    • Uniformly colorized beads for multiplex immunoassay
    • DOI 10.1021/cm060283f
    • X. Zhao, Z. Liu, H. Yang, K. Nagai, Y. Zhao, and Z. Gu, "Uniformly Colorized Beads for Multiplex Immunoassay," Chem. Mater., vol. 18, no. 9, pp. 2443-2449, Apr. 2006. (Pubitemid 43836594)
    • (2006) Chemistry of Materials , vol.18 , Issue.9 , pp. 2443-2449
    • Zhao, X.-W.1    Liu, Z.-B.2    Yang, H.3    Nagai, K.4    Zhao, Y.-H.5    Gu, Z.-Z.6
  • 27
    • 79952265731 scopus 로고    scopus 로고
    • NanoLAB: An ultraportable, handheld diagnostic laboratory for global health
    • Jan.
    • R. S. Gaster, D. H. Hall, and S. X. Wang, "nanoLAB: An ultraportable, handheld diagnostic laboratory for global health," Lab Chip. vol. 11, no. 5, pp. 950-956, Jan. 2011.
    • (2011) Lab Chip. Vol. 11 , Issue.5 , pp. 950-956
    • Gaster, R.S.1    Hall, D.H.2    Wang, S.X.3
  • 29
    • 18144383483 scopus 로고    scopus 로고
    • ® by magnetization measurements and Mossbauer spectroscopy
    • DOI 10.1016/j.jmmm.2005.01.041, PII S030488530500106X
    • G. Fonnum, C. Johansson, A. Molteberg, S. Morup, and E. Aksnes, "Characterization of Dynabeads® by magnetization measurements and Mössbauer spectroscopy," J. Magn. Magn. Mater. vol. 293, no. 1, pp. 41-47, May 2005. (Pubitemid 40608908)
    • (2005) Journal of Magnetism and Magnetic Materials , vol.293 , Issue.1 , pp. 41-47
    • Fonnum, G.1    Johansson, C.2    Molteberg, A.3    Morup, S.4    Aksnes, E.5
  • 30
    • 0034076282 scopus 로고    scopus 로고
    • The thermal stability of immunoglobulin: Unfolding and aggregation of a multi-domain protein
    • A. W. Vermeer and W. Norde, "The thermal stability of immunoglobulin: Unfolding and aggregation of a multi-domain protein," Biophys. J. vol. 78, no. 1, pp. 394-404, Jan. 2000 (Pubitemid 30207148)
    • (2000) Biophysical Journal , vol.78 , Issue.1 , pp. 394-404
    • Vermeer, A.W.P.1    Norde, W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.