메뉴 건너뛰기




Volumn 55, Issue , 2012, Pages 126-127

A CMOS 10kpixel baseline-free magnetic bead detector with column-parallel readout for miniaturized immunoassays

Author keywords

[No Author keywords available]

Indexed keywords

BIOLOGICAL VARIATION; DETECTION SYSTEM; MAGNETIC BEADS; MAGNETIC RESPONSE; MEASUREMENT TIME; POINT OF CARE; POINT-OF-CARE SYSTEMS; POLARIZATION FIELD; PRACTICAL SYSTEMS; REFERENCE SENSORS; SENSING AREAS; SPECIFIC DETECTION; TECHNOLOGICAL CHALLENGES; TEMPERATURE STABILIZATION;

EID: 84860681192     PISSN: 01936530     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISSCC.2012.6176948     Document Type: Conference Paper
Times cited : (22)

References (8)
  • 4
    • 80052648067 scopus 로고    scopus 로고
    • Magnetic Relaxation Detector for Microbead Labels in Bio-Medical Assays
    • June
    • P. Liu, et al., "Magnetic Relaxation Detector for Microbead Labels in Bio-Medical Assays," IEEE Symp. VLSI Circuits, pp.176-177, June 2011.
    • (2011) IEEE Symp. VLSI Circuits , pp. 176-177
    • Liu, P.1
  • 5
    • 70349268229 scopus 로고    scopus 로고
    • A Frequency-Shift CMOS Magnetic Biosensor Array with Single-Bead Sensitivity and No External Magnet
    • Feb.
    • H. Wang, Y. Chen, A. Hassibi, A. Scherer, and A. Hajimiri, "A Frequency-Shift CMOS Magnetic Biosensor Array with Single-Bead Sensitivity and No External Magnet," ISSCC Dig. Tech. Papers, pp. 438-439, Feb. 2009.
    • (2009) ISSCC Dig. Tech. Papers , pp. 438-439
    • Wang, H.1    Chen, Y.2    Hassibi, A.3    Scherer, A.4    Hajimiri, A.5
  • 6
    • 21444438484 scopus 로고    scopus 로고
    • Biological Shot-Noise and Quantum-Limited Signal-to-Noise Ratio in Affinity-Based Biosensors
    • Apr.
    • A. Hassibi, Z. Sina, R. Navid, R. Dutton, and T.H. Lee, "Biological Shot-Noise and Quantum-Limited Signal-to-Noise Ratio in Affinity-Based Biosensors,"Journal of Applied Physics, vol. 97, no. 8, Apr. 2005.
    • (2005) Journal of Applied Physics , vol.97 , Issue.8
    • Hassibi, A.1    Sina, Z.2    Navid, R.3    Dutton, R.4    Lee, T.H.5
  • 7
    • 49549112712 scopus 로고    scopus 로고
    • A Mode-Matching ΔΣ Closed-Loop Vibratory-Gyroscope Readout Interface with a 0.004 deg/s/rt(Hz) Noise Floor over a 50 Hz Band
    • Feb.
    • C. Ezekwe and B. Boser, "A Mode-Matching ΔΣ Closed-Loop Vibratory-Gyroscope Readout Interface with a 0.004 deg/s/rt(Hz) Noise Floor Over a 50 Hz Band," ISSCC Dig. Tech. Papers, pp. 580-581, Feb. 2008.
    • (2008) ISSCC Dig. Tech. Papers , pp. 580-581
    • Ezekwe, C.1    Boser, B.2
  • 8
    • 80052253331 scopus 로고    scopus 로고
    • Microfluidic Bio-Processor for Solid State Capture Immunoassays
    • J. Kim, E. Jensen, M. Megens, R. Mathies, and B. Boser, "Microfluidic Bio-Processor for Solid State Capture Immunoassays," Lab Chip, vol. 11, pp. 3106-3112, 2011.
    • (2011) Lab Chip , vol.11 , pp. 3106-3112
    • Kim, J.1    Jensen, E.2    Megens, M.3    Mathies, R.4    Boser, B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.