메뉴 건너뛰기




Volumn 92, Issue 2, 2014, Pages 126-132

Retinal and choroidal intravascular spectral-domain optical coherence tomography

Author keywords

blood flow imaging; central retinal artery occlusion; choroidal blood flow; in vivo; ocular ischemic syndrome; optical coherence tomography; red blood cell alignment; retinal blood flow; shear rate

Indexed keywords

ADULT; AGED; ARTICLE; CASE STUDY; CENTRAL RETINA ARTERY OCCLUSION; CHILD; CHOROID VASCULARIZATION; CLINICAL ARTICLE; CONTROLLED STUDY; EYE BLOOD FLOW; FEMALE; HEMATOCRIT; HUMAN; MALE; OCULAR ISCHEMIC SYNDROME; OPHTHALMIC ULTRASOUND SCANNER; OPTICAL DENSITY; ORGAN PERFUSION; PRIORITY JOURNAL; RETINA BLOOD VESSEL; RETROSPECTIVE STUDY; SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY;

EID: 84896723226     PISSN: 1755375X     EISSN: 17553768     Source Type: Journal    
DOI: 10.1111/aos.12048     Document Type: Article
Times cited : (16)

References (28)
  • 1
    • 74049112013 scopus 로고    scopus 로고
    • Photometric measurements of red blood cell aggregation: Light transmission versus light reflectance
    • Baskurt OK, Uyuklu M, Hardeman MR, &, Meiselman HJ, (2009): Photometric measurements of red blood cell aggregation: light transmission versus light reflectance. J Biomed Opt 14: 054044.
    • (2009) J Biomed Opt , vol.14 , pp. 054044
    • Baskurt, O.K.1    Uyuklu, M.2    Hardeman, M.R.3    Meiselman, H.J.4
  • 2
    • 0022508788 scopus 로고
    • Red blood cell orientation in orbit C = 0
    • Bitbol M, (1986): Red blood cell orientation in orbit C = 0. Biophys J 49: 1055-1068.
    • (1986) Biophys J , vol.49 , pp. 1055-1068
    • Bitbol, M.1
  • 3
    • 0022964126 scopus 로고
    • The light reflex on retinal arteries and veins. A theoretical study and a new technique for measuring width and intensity profiles across retinal vessels
    • Brinchmann-Hansen O, (1986): The light reflex on retinal arteries and veins. A theoretical study and a new technique for measuring width and intensity profiles across retinal vessels. Acta Ophthalmol Suppl 179: 1-53.
    • (1986) Acta Ophthalmol Suppl , vol.179 , pp. 1-53
    • Brinchmann-Hansen, O.1
  • 4
    • 0022884998 scopus 로고
    • Theoretical relations between light streak characteristics and optical properties of retinal vessels
    • Brinchmann-Hansen O, &, Heier H, (1986): Theoretical relations between light streak characteristics and optical properties of retinal vessels. Acta Ophthalmol (Copenh) 64: 33-37.
    • (1986) Acta Ophthalmol (Copenh) , vol.64 , pp. 33-37
    • Brinchmann-Hansen, O.1    Heier, H.2
  • 5
    • 0022527060 scopus 로고
    • The intensity of the light reflex on retinal arteries and veins
    • Brinchmann-Hansen O, &, Sandvik L, (1986a): The intensity of the light reflex on retinal arteries and veins. Acta Ophthalmol (Copenh) 64: 547-552.
    • (1986) Acta Ophthalmol (Copenh) , vol.64 , pp. 547-552
    • Brinchmann-Hansen, O.1    Sandvik, L.2
  • 6
    • 0022512641 scopus 로고
    • The width of the light reflex on retinal arteries and veins
    • Brinchmann-Hansen O, &, Sandvik L, (1986b): The width of the light reflex on retinal arteries and veins. Acta Ophthalmol (Copenh) 64: 433-438.
    • (1986) Acta Ophthalmol (Copenh) , vol.64 , pp. 433-438
    • Brinchmann-Hansen, O.1    Sandvik, L.2
  • 7
    • 0035019802 scopus 로고    scopus 로고
    • The "black hole" phenomenon in ultrasonic backscattering measurement under pulsatile flow with porcine whole blood in a rigid tube
    • Cao PJ, Paeng DG, &, Shung KK, (2001): The "black hole" phenomenon in ultrasonic backscattering measurement under pulsatile flow with porcine whole blood in a rigid tube. Biorheology 38: 15-26.
    • (2001) Biorheology , vol.38 , pp. 15-26
    • Cao, P.J.1    Paeng, D.G.2    Shung, K.K.3
  • 8
    • 80655143460 scopus 로고    scopus 로고
    • Shear flow-induced optical inhomogeneity of blood assessed in vivo and in vitro by spectral domain optical coherence tomography in the 1.3 mum wavelength range
    • Cimalla P, Walther J, Mittasch M, &, Koch E, (2011): Shear flow-induced optical inhomogeneity of blood assessed in vivo and in vitro by spectral domain optical coherence tomography in the 1.3 mum wavelength range. J Biomed Opt 16: 116020.
    • (2011) J Biomed Opt , vol.16 , pp. 116020
    • Cimalla, P.1    Walther, J.2    Mittasch, M.3    Koch, E.4
  • 9
    • 0031263394 scopus 로고    scopus 로고
    • Ultrasound backscattering from non-aggregating and aggregating erythrocytes - A review
    • Cloutier G, &, Qin Z, (1997): Ultrasound backscattering from non-aggregating and aggregating erythrocytes-a review. Biorheology 34: 443-470.
    • (1997) Biorheology , vol.34 , pp. 443-470
    • Cloutier, G.1    Qin, Z.2
  • 10
    • 84896738257 scopus 로고
    • Microscopic laser Doppler velocimeter for blood velocity measurement
    • Eiju T, Nagai M, Matsuda K, Ohtsubo J, Homma K, &, Shimizu K, (1993): Microscopic laser Doppler velocimeter for blood velocity measurement. Circulation 1996: 3257-3262.
    • (1993) Circulation , vol.1996 , pp. 3257-3262
    • Eiju, T.1    Nagai, M.2    Matsuda, K.3    Ohtsubo, J.4    Homma, K.5    Shimizu, K.6
  • 11
    • 0037363747 scopus 로고    scopus 로고
    • Influence of cell shape and aggregate formation on the optical properties of flowing whole blood
    • Enejder AM, Swartling J, Aruna P, &, Andersson-Engels S, (2003): Influence of cell shape and aggregate formation on the optical properties of flowing whole blood. Appl Opt 42: 1384-1394.
    • (2003) Appl Opt , vol.42 , pp. 1384-1394
    • Enejder, A.M.1    Swartling, J.2    Aruna, P.3    Andersson-Engels, S.4
  • 12
    • 38449103270 scopus 로고    scopus 로고
    • Influence of shear rate on the optical properties of human blood in the spectral range 250 to 1100 nm
    • Friebel M, Helfmann J, Muller G, &, Meinke M, (2007): Influence of shear rate on the optical properties of human blood in the spectral range 250 to 1100 nm. J Biomed Opt 12: 054005.
    • (2007) J Biomed Opt , vol.12 , pp. 054005
    • Friebel, M.1    Helfmann, J.2    Muller, G.3    Meinke, M.4
  • 13
    • 0032988038 scopus 로고    scopus 로고
    • Orientation and deformation of erythrocytes in flowing blood
    • Fujii M, Nakajima K, Sakamoto K, &, Kanai H, (1999): Orientation and deformation of erythrocytes in flowing blood. Ann N Y Acad Sci 873: 245-261.
    • (1999) Ann N y Acad Sci , vol.873 , pp. 245-261
    • Fujii, M.1    Nakajima, K.2    Sakamoto, K.3    Kanai, H.4
  • 14
    • 80052597258 scopus 로고    scopus 로고
    • Doppler velocity detection limitations in spectrometer-based versus swept-source optical coherence tomography
    • Hendargo HC, McNabb RP, Dhalla AH, Shepherd N, &, Izatt JA, (2011): Doppler velocity detection limitations in spectrometer-based versus swept-source optical coherence tomography. Biomed Opt Express 2: 2175-2188.
    • (2011) Biomed Opt Express , vol.2 , pp. 2175-2188
    • Hendargo, H.C.1    McNabb, R.P.2    Dhalla, A.H.3    Shepherd, N.4    Izatt, J.A.5
  • 15
    • 0029026664 scopus 로고
    • Noninvasive determination of shear-rate distribution across the arterial lumen
    • Hoeks AP, Samijo SK, Brands PJ, &, Reneman RS, (1995): Noninvasive determination of shear-rate distribution across the arterial lumen. Hypertension 26: 26-33.
    • (1995) Hypertension , vol.26 , pp. 26-33
    • Hoeks, A.P.1    Samijo, S.K.2    Brands, P.J.3    Reneman, R.S.4
  • 16
    • 0037284198 scopus 로고    scopus 로고
    • Velocity profile of red blood cells in human retinal vessels using confocal scanning laser doppler velocimetry
    • Logean L, Schmetterer L, &, Riva CE, (2003): Velocity profile of red blood cells in human retinal vessels using confocal scanning laser doppler velocimetry. Laser Phys 13: 45-51.
    • (2003) Laser Phys , vol.13 , pp. 45-51
    • Logean, L.1    Schmetterer, L.2    Riva, C.E.3
  • 17
    • 79951835647 scopus 로고    scopus 로고
    • MRI of retinal and choroidal blood flow with laminar resolution
    • Muir ER, &, Duong TQ, (2011): MRI of retinal and choroidal blood flow with laminar resolution. NMR Biomed 24: 216-223.
    • (2011) NMR Biomed , vol.24 , pp. 216-223
    • Muir, E.R.1    Duong, T.Q.2
  • 18
    • 33645404162 scopus 로고    scopus 로고
    • Noninvasive evaluation of wall shear stress on retinal microcirculation in humans
    • Nagaoka T, &, Yoshida A, (2006): Noninvasive evaluation of wall shear stress on retinal microcirculation in humans. Invest Ophthalmol Vis Sci 47: 1113-1119.
    • (2006) Invest Ophthalmol Vis Sci , vol.47 , pp. 1113-1119
    • Nagaoka, T.1    Yoshida, A.2
  • 20
    • 84894297516 scopus 로고    scopus 로고
    • Measurement of anisotropic reflection of flowing blood using optical coherence tomography
    • Nam K-H, Jeong B, Jung IO, Ha H, Kim KH, &, Lee SJ, (2011): Measurement of anisotropic reflection of flowing blood using optical coherence tomography. J Biomed Opt 16: 120502.
    • (2011) J Biomed Opt , vol.16 , pp. 120502
    • Nam, K.-H.1    Jeong, B.2    Jung, I.O.3    Ha, H.4    Kim, K.H.5    Lee, S.J.6
  • 21
  • 24
    • 0014683236 scopus 로고
    • Fluid drop-like transition of erythrocytes under shear
    • Schmid-Schoenbein H, &, Wells R, (1969): Fluid drop-like transition of erythrocytes under shear. Science 165: 288-291.
    • (1969) Science , vol.165 , pp. 288-291
    • Schmid-Schoenbein, H.1    Wells, R.2
  • 25
    • 80655143450 scopus 로고    scopus 로고
    • Wavelength selection in measuring red blood cell aggregation based on light transmittance
    • Uyuklu M, Canpolat M, Meiselman HJ, &, Baskurt OK, (2011): Wavelength selection in measuring red blood cell aggregation based on light transmittance. J Biomed Opt 16: 117006.
    • (2011) J Biomed Opt , vol.16 , pp. 117006
    • Uyuklu, M.1    Canpolat, M.2    Meiselman, H.J.3    Baskurt, O.K.4
  • 26
    • 59049096490 scopus 로고    scopus 로고
    • Effects of axial, transverse, and oblique sample motion in FD OCT in systems with global or rolling shutter line detector
    • Walther J, Kruger A, Cuevas M, &, Koch E, (2008): Effects of axial, transverse, and oblique sample motion in FD OCT in systems with global or rolling shutter line detector. J Opt Soc Am A Opt Image Sci Vis 25: 2791-2802.
    • (2008) J Opt Soc Am A Opt Image Sci Vis , vol.25 , pp. 2791-2802
    • Walther, J.1    Kruger, A.2    Cuevas, M.3    Koch, E.4
  • 27
    • 79955020364 scopus 로고    scopus 로고
    • Effect of tempol on diabetes-induced decreases in retinal blood flow in the mouse
    • Yadav AS, &, Harris NR, (2011): Effect of tempol on diabetes-induced decreases in retinal blood flow in the mouse. Curr Eye Res 36: 456-461.
    • (2011) Curr Eye Res , vol.36 , pp. 456-461
    • Yadav, A.S.1    Harris, N.R.2
  • 28
    • 4644298765 scopus 로고    scopus 로고
    • Motion artifacts in optical coherence tomography with frequency-domain ranging
    • Yun SH, Tearney G, de BJ, &, Bouma B, (2004): Motion artifacts in optical coherence tomography with frequency-domain ranging. Opt Express 12: 2977-2998.
    • (2004) Opt Express , vol.12 , pp. 2977-2998
    • Yun, S.H.1    Tearney, G.2    De, B.J.3    Bouma, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.