메뉴 건너뛰기




Volumn 15, Issue 2, 2014, Pages 181-190

Clinical evaluation of an anatomy-based patient specific quality assurance system

Author keywords

DVH based QA; Patient specific quality assurance; Volumetric modulated arc therapy

Indexed keywords


EID: 84896338863     PISSN: None     EISSN: 15269914     Source Type: Journal    
DOI: 10.1120/jacmp.v15i2.4647     Document Type: Article
Times cited : (21)

References (22)
  • 1
    • 0141520680 scopus 로고    scopus 로고
    • Evaluation of the gamma dose distribution comparison method
    • Low DA and Dempsey JF. Evaluation of the gamma dose distribution comparison method. Med Phys. 2003;30(9):2455-64.
    • (2003) Med Phys , vol.30 , Issue.9 , pp. 2455-2464
    • Low, D.A.1    Dempsey, J.F.2
  • 3
    • 84859746236 scopus 로고    scopus 로고
    • Evaluation of PTW Seven29 for tomotherapy patient-specific quality assurance and comparison with ScandiDos Delta4
    • Myers P, Stathakis S, Gutiérrez AN, Esquivel C, Mavroidis P, Papanikolaou N. Evaluation of PTW Seven29 for tomotherapy patient-specific quality assurance and comparison with ScandiDos Delta4. Med Phys. 2012;37(2):72-80.
    • (2012) Med Phys , vol.37 , Issue.2 , pp. 72-80
    • Myers, P.1    Stathakis, S.2    Gutiérrez, A.N.3    Esquivel, C.4    Mavroidis, P.5    Papanikolaou, N.6
  • 4
    • 77749339334 scopus 로고    scopus 로고
    • Characterization, commissioning and evaluation of DELTA4 IMRT QA system [abstract]
    • Sadagopan R, BenComo J, Martin R, Balter P, Vedam S, Nilsson G. Characterization, commissioning and evaluation of DELTA4 IMRT QA system [abstract]. Med Phys. 2007;34(6):2560.
    • (2007) Med Phys , vol.34 , Issue.6 , pp. 2560
    • Sadagopan, R.1    BenComo, J.2    Martin, R.3    Balter, P.4    Vedam, S.5    Nilsson, G.6
  • 5
    • 79551672470 scopus 로고    scopus 로고
    • Per-beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors
    • Nelms BE, Zhen H, Tomé WA. Per-beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors. Med Phys. 2011;38(2):1037-44.
    • (2011) Med Phys , vol.38 , Issue.2 , pp. 1037-1044
    • Nelms, B.E.1    Zhen, H.2    Tomé, W.A.3
  • 6
    • 80255134521 scopus 로고    scopus 로고
    • Patient-specific 3D pretreatment and potential 3D online dose verification of Monte Carlo-calculated IMRT prostate treatment plans
    • Boggula R, Jahnke L, Wertz H, Lohr F, Wenz F. Patient-specific 3D pretreatment and potential 3D online dose verification of Monte Carlo-calculated IMRT prostate treatment plans. Int J Radiat Oncol Biol Phys. 2011;81(4):1168-75.
    • (2011) Int J Radiat Oncol Biol Phys , vol.81 , Issue.4 , pp. 1168-1175
    • Boggula, R.1    Jahnke, L.2    Wertz, H.3    Lohr, F.4    Wenz, F.5
  • 7
    • 80053595703 scopus 로고    scopus 로고
    • Moving from gamma passing rates to patient DVH-based QA metrics in pretreatment dose QA
    • Zhen H, Nelms BE, Tomé WA. Moving from gamma passing rates to patient DVH-based QA metrics in pretreatment dose QA. Med Phys. 2011;38(10):5477-89.
    • (2011) Med Phys , vol.38 , Issue.10 , pp. 5477-5489
    • Zhen, H.1    Nelms, B.E.2    Tomé, W.A.3
  • 8
    • 85024385726 scopus 로고    scopus 로고
    • Comparing measurement derived (3DVH) and machine log file derived dose reconstruction methods for VMAT QA in heterogeneous patient geometries [abstract]
    • Tyagi N, Yang K, Yan D. Comparing measurement derived (3DVH) and machine log file derived dose reconstruction methods for VMAT QA in heterogeneous patient geometries [abstract]. Med Phys. 2013;40:241.
    • (2013) Med Phys , vol.40 , pp. 241
    • Tyagi, N.1    Yang, K.2    Yan, D.3
  • 9
    • 33750573370 scopus 로고    scopus 로고
    • AAA photon dose calculation model in eclipse. Varian RandD 7170B
    • Palo Alto, CA: Varian Medical Systems;
    • Sievinen J, Ulmers W, Kaissl W. AAA photon dose calculation model in eclipse. Varian RandD #7170B. Palo Alto, CA: Varian Medical Systems; 2005.
    • (2005)
    • Sievinen, J.1    Ulmers, W.2    Kaissl, W.3
  • 10
    • 79959344605 scopus 로고    scopus 로고
    • Commissioning of photon beams of a flattening filter-free linear accelerator and the accuracy of beam modeling using an anisotropic analytical algorithm
    • Hrbacek J, Lang S, Klöck S. Commissioning of photon beams of a flattening filter-free linear accelerator and the accuracy of beam modeling using an anisotropic analytical algorithm. Int J Radiat Oncol Biol Phys. 2011;80(4):1228-37.
    • (2011) Int J Radiat Oncol Biol Phys , vol.80 , Issue.4 , pp. 1228-1237
    • Hrbacek, J.1    Lang, S.2    Klöck, S.3
  • 12
    • 34748872532 scopus 로고    scopus 로고
    • On-line quality assurance of rotational radiotherapy treatment delivery by means of a 2D ion chamber array and the Octavius phantom
    • Van Esch A, Clermont C, Devillers M, Iori M, Huyskens DP. On-line quality assurance of rotational radiotherapy treatment delivery by means of a 2D ion chamber array and the Octavius phantom. Med Phys. 2007;34(10):3825-37.
    • (2007) Med Phys , vol.34 , Issue.10 , pp. 3825-3837
    • Van Esch, A.1    Clermont, C.2    Devillers, M.3    Iori, M.4    Huyskens, D.P.5
  • 13
    • 48849108249 scopus 로고    scopus 로고
    • Evaluation of the water equivalence of solid phantoms using gamma ray transmission measurements
    • Hill RF, Brown S, Baldock C. Evaluation of the water equivalence of solid phantoms using gamma ray transmission measurements. Radiat Meas. 2008;43(7):1258-64.
    • (2008) Radiat Meas , vol.43 , Issue.7 , pp. 1258-1264
    • Hill, R.F.1    Brown, S.2    Baldock, C.3
  • 14
    • 84896333257 scopus 로고    scopus 로고
    • ScandiDos. Scandidos interactive user's guide
    • Uppsala, Sweden: ScandiDos. Received Jan
    • ScandiDos. Scandidos interactive user's guide. Uppsala, Sweden: ScandiDos. Received Jan. 2013.
    • (2013)
  • 15
    • 84873601763 scopus 로고    scopus 로고
    • Efficient and reliable 3D dose quality assurance for IMRT by combining independent dose calculations with measurements
    • Visser R, Wauben DJL, de Groot M, et al. Efficient and reliable 3D dose quality assurance for IMRT by combining independent dose calculations with measurements. Med Phys. 2013;40(2):021710.
    • (2013) Med Phys , vol.40 , Issue.2 , pp. 021710
    • Visser, R.1    Wauben, D.J.L.2    de Groot, M.3
  • 16
    • 85024390277 scopus 로고    scopus 로고
    • 3D dosimetry for volumetric modulated arc stereotactic delivery using Compass [abstract]
    • 4-8 Aug, 2013, Indianapolis, IN
    • Vikraman S, Manigandan D, Mohanraj U, et al. 3D dosimetry for volumetric modulated arc stereotactic delivery using Compass [abstract]. Present at the AAPM 55th Annual Meeting, 4-8 Aug, 2013, Indianapolis, IN.
    • Present at the AAPM 55th Annual Meeting
    • Vikraman, S.1    Manigandan, D.2    Mohanraj, U.3
  • 17
    • 84855420749 scopus 로고    scopus 로고
    • Evaluation of IMRT QA using 3DVH, a 3D patient dose and verifcation analysis software [abstract]
    • Martin GD, Lemire M, Ayles M, Pater P. Evaluation of IMRT QA using 3DVH, a 3D patient dose and verifcation analysis software [abstract]. Med Phys. 2011;38(5):3581.
    • (2011) Med Phys , vol.38 , Issue.5 , pp. 3581
    • Martin, G.D.1    Lemire, M.2    Ayles, M.3    Pater, P.4
  • 18
    • 82555195582 scopus 로고    scopus 로고
    • Evaluation of pencil beam convolution and anisotropic analytical algorithms in stereotactic lung irradiation
    • De La Fuente Herman T, Hibbitts K, Herman T, Ahmad S. Evaluation of pencil beam convolution and anisotropic analytical algorithms in stereotactic lung irradiation. Med Phys. 2011;36(4):234-38.
    • (2011) Med Phys , vol.36 , Issue.4 , pp. 234-238
    • De La Fuente Herman, T.1    Hibbitts, K.2    Herman, T.3    Ahmad, S.4
  • 19
  • 20
    • 0037962451 scopus 로고    scopus 로고
    • Comparison of IMRT optimization based on a pencil beam and a superposition algorithm
    • Scholz C, Nill S, Oelfke U. Comparison of IMRT optimization based on a pencil beam and a superposition algorithm. Med Phys. 2003;30(7):1909-13.
    • (2003) Med Phys , vol.30 , Issue.7 , pp. 1909-1913
    • Scholz, C.1    Nill, S.2    Oelfke, U.3
  • 21
    • 85024379754 scopus 로고    scopus 로고
    • Verifcation of volumetric modulated arc therapy plans with independent three dimensional dose computation algorithm [abstract]
    • Kathirvel M, Shanmuga S, Arun G, et al. Verifcation of volumetric modulated arc therapy plans with independent three dimensional dose computation algorithm [abstract]. Med Phys. 2001;38(6):3667.
    • (2001) Med Phys , vol.38 , Issue.6 , pp. 3667
    • Kathirvel, M.1    Shanmuga, S.2    Arun, G.3
  • 22
    • 85024362604 scopus 로고    scopus 로고
    • SunNuclear. 3DVH: On the accuracy of the planned dose perturbation algorithm
    • Melbourne, FL: Sun Nuclear; [n d]. Available from
    • SunNuclear. 3DVH: On the accuracy of the planned dose perturbation algorithm. Melbourne, FL: Sun Nuclear; [n d]. Available from: http://www.sunnuclear.com/documents/1212W05062010.pdf


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.