-
1
-
-
34447558140
-
Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography
-
DOI 10.1001/jama.298.3.317
-
A. J. Einstein,M. J. Henzlova, and S. Rajagopalan, "Estimating risk of cancer associated with radiation exposure from 64-slice CT coronary angiography," J. Am. Med. Assoc., vol. 298, pp. 317-323, Jul. 2007. (Pubitemid 47080486)
-
(2007)
Journal of the American Medical Association
, vol.298
, Issue.3
, pp. 317-323
-
-
Einstein, A.J.1
Henzlova, M.J.2
Rajagopalan, S.3
-
2
-
-
36549007486
-
Computed tomography - An increasing source of radiation exposure
-
DOI 10.1056/NEJMra072149
-
D. J. Brenner and E. J. Hall, "CT-An increasing source of radiation exposure," New Eng. J. Med., vol. 357, pp. 2277-2284, Nov. 2007. (Pubitemid 350190758)
-
(2007)
New England Journal of Medicine
, vol.357
, Issue.22
, pp. 2277-2284
-
-
Brenner, D.J.1
Hall, E.J.2
-
3
-
-
0026222041
-
Nonstationary filtering of transmission tomograms in high photon counting noise
-
DOI 10.1109/42.97595
-
K. Sauer and B. Liu, "Non-stationary filtering of transmission tomograms in high photon counting noise," IEEE Trans. Med. Imag., vol. 10, no. 3, pp. 445-452, Sep. 1991. (Pubitemid 21727991)
-
(1991)
IEEE Transactions on Medical Imaging
, vol.10
, Issue.3
, pp. 445-452
-
-
Sauer Ken1
Liu Bede2
-
4
-
-
0035554667
-
Noise properties of low-dose CT projections and noise treatment by scale transformations
-
Nov.
-
H. Lu, I. Hsiao, X. Li, and Z. Liang, "Noise properties of low-dose CT projections and noise treatment by scale transformations," in Nucl. Sci. Symp. Med. Imag. Conf. Rec., Nov. 2001, vol. 3, pp. 1662-1666.
-
(2001)
Nucl. Sci. Symp. Med. Imag. Conf. Rec.
, vol.3
, pp. 1662-1666
-
-
Lu, H.1
Hsiao, I.2
Li, X.3
Liang, Z.4
-
5
-
-
0034839479
-
Reduction of noise and image artifacts in computed tomography by nonlinear filtration of the projection images
-
Jul.
-
K. Demirkaya, "Reduction of noise and image artifacts in computed tomography by nonlinear filtration of the projection images," in Proc. SPIE Med. Imag., Jul. 2001, vol. 4322, pp. 917-923.
-
(2001)
Proc. SPIE Med. Imag.
, vol.4322
, pp. 917-923
-
-
Demirkaya, K.1
-
6
-
-
0036033694
-
Analytical noise treatment for low-dose CT projection data by penalized weighted least-square smoothing in the K-L domain
-
DOI 10.1117/12.465552
-
H. Lu, X. Li, and Z. Liang, "Analytical noise treatment for low-dose CT projection data by penalized weighted least-square smoothing in the K-L domain," in Proc. SPIE Med. Imag., May 2002, vol. 4682, pp. 146-152. (Pubitemid 35237107)
-
(2002)
Proceedings of SPIE - The International Society for Optical Engineering
, vol.4682
, pp. 146-152
-
-
Lu, H.1
Li, X.2
Hsiao, I.-T.3
Liang, Z.4
-
7
-
-
0036462553
-
Statistical image reconstruction for polyenergetic X-ray computed tomography
-
DOI 10.1109/42.993128, PII S0278006202029361
-
I. A. Elbakri and J. A. Fessler, "Statistical image reconstruction for polyenergetic X-ray CT," IEEE Trans. Med. Imag., vol. 21, no. 2, pp. 89-99, Feb. 2002. (Pubitemid 34466423)
-
(2002)
IEEE Transactions on Medical Imaging
, vol.21
, Issue.2
, pp. 89-99
-
-
Elbakri, I.A.1
Fessler, J.A.2
-
8
-
-
0042421775
-
Efficient and accurate likelihood for iterative image reconstruction in X-ray CT
-
Feb
-
I. A. Elbakri and J. A. Fessler, "Efficient and accurate likelihood for iterative image reconstruction in X-ray CT," in Proc. SPIEMed. Imag., Feb, 2003, vol. 5032, pp. 1839-1850.
-
(2003)
Proc. SPIEMed. Imag.
, vol.5032
, pp. 1839-1850
-
-
Elbakri, I.A.1
Fessler, J.A.2
-
9
-
-
8344272167
-
Nonlinear sinogram smoothing for low-dose X-ray CT
-
Oct.
-
T. Li,X. Li, J. Wang, J.Wen,H. Lu, J. Hsieh, and Z. Liang, "Nonlinear sinogram smoothing for low-dose X-ray CT," IEEE Trans. Nucl. Sci., vol. 51, no. 5, pp. 2505-2513, Oct. 2004.
-
(2004)
IEEE Trans. Nucl. Sci.
, vol.51
, Issue.5
, pp. 2505-2513
-
-
Li, T.1
Li, X.2
Wang, J.3
Wen, J.4
Lu, H.5
Hsieh, J.6
Liang, Z.7
-
10
-
-
21144458117
-
Penalized-likelihood sinogram smoothing for lowdose CT
-
P. J. La Riviere, "Penalized-likelihood sinogram smoothing for lowdose CT," Med. Phys., vol. 32, no. 6, pp. 1676-1683, 2005.
-
(2005)
Med. Phys.
, vol.32
, Issue.6
, pp. 1676-1683
-
-
La Riviere, P.J.1
-
11
-
-
33746927954
-
Penalized-likelihood sinogram restoration for CT
-
Aug.
-
P. J. La Rivière, J. Bian, and P. A. Vargas, "Penalized- likelihood sinogram restoration for CT," IEEE Trans. Med. Imag., vol. 25, no. 8, pp. 1022-1036, Aug. 2006.
-
(2006)
IEEE Trans. Med. Imag.
, vol.25
, Issue.8
, pp. 1022-1036
-
-
La Rivière, P.J.1
Bian, J.2
Vargas, P.A.3
-
12
-
-
33947260155
-
Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography
-
DOI 10.1109/TMI.2006.882141
-
J.Wang, T. Li, H. Lu, and Z. Liang, "Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray CT," IEEE Trans. Med. Imag., vol. 25, no. 10, pp. 1272-1283, Oct. 2006. (Pubitemid 46417077)
-
(2006)
IEEE Transactions on Medical Imaging
, vol.25
, Issue.10
, pp. 1272-1283
-
-
Wang, J.1
Li, T.2
Lu, H.3
Liang, Z.4
-
13
-
-
33745162201
-
Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT
-
E. Sidky, C. Kao, and X. Pan, "Accurate image reconstruction from few-views and limited angle data in divergent-beam CT," J. X-Ray Sci. Technol., vol. 14, no. 2, pp. 119-139, 2006. (Pubitemid 43893801)
-
(2006)
Journal of X-Ray Science and Technology
, vol.14
, Issue.2
, pp. 119-139
-
-
Sidky, E.Y.1
Kao, C.-M.2
Pan, X.3
-
14
-
-
42149121465
-
Prior image constrained compressed sensing (PICCS)
-
Mar.
-
G. Chen, J. Tang, and S. Leng, "Prior image constrained compressed sensing (PICCS)," Proc. Soc. Photon Instrum. Eng., vol. 6856, pp. 1-18, Mar. 2008.
-
(2008)
Proc. Soc. Photon Instrum. Eng.
, vol.6856
, pp. 1-18
-
-
Chen, G.1
Tang, J.2
Leng, S.3
-
15
-
-
51849124226
-
Image reconstruction in circular cone-beam CT by constrained, total-variation minimization
-
Aug.
-
E. Sidky and X. Pan, "Image reconstruction in circular cone-beam CT by constrained, total-variation minimization," Phys. Med. Biol., vol. 53, pp. 4777-4807, Aug. 2008.
-
(2008)
Phys. Med. Biol.
, vol.53
, pp. 4777-4807
-
-
Sidky, E.1
Pan, X.2
-
16
-
-
58149141914
-
Iterative image reconstruction for CBCT using edge-preserving prior
-
Jan.
-
J.Wang, T. Li, and L. Xing, "Iterative image reconstruction for CBCT using edge-preserving prior," Med. Phys., vol. 36, no. 1, pp. 252-260, Jan. 2009.
-
(2009)
Med. Phys.
, vol.36
, Issue.1
, pp. 252-260
-
-
Wang, J.1
Li, T.2
Xing, L.3
-
17
-
-
79952136862
-
Algorithm-enabled low-dose micro-CT imaging
-
Mar.
-
X. Han, J. Bian, D. R. Eaker, T. L. Kline, E. Y. Sidky, E. L. Ritman, and X. Pan, "Algorithm-enabled low-dose micro-CT imaging," IEEE Trans. Med. Imag., vol. 30, no. 3, pp. 606-620, Mar. 2011.
-
(2011)
IEEE Trans. Med. Imag.
, vol.30
, Issue.3
, pp. 606-620
-
-
Han, X.1
Bian, J.2
Eaker, D.R.3
Kline, T.L.4
Sidky, E.Y.5
Ritman, E.L.6
Pan, X.7
-
18
-
-
84864264764
-
Variance analysis of X-ray CT sinograms in the presence of electronic noise background
-
Jun.
-
J. Ma, Z. Liang, Y. Fan, Y. Liu, J. Huang, W. Chen, and H. Lu, "Variance analysis of X-ray CT sinograms in the presence of electronic noise background," Med. Phys., vol. 39, no. 7, pp. 4051-4065, Jun. 2012.
-
(2012)
Med. Phys.
, vol.39
, Issue.7
, pp. 4051-4065
-
-
Ma, J.1
Liang, Z.2
Fan, Y.3
Liu, Y.4
Huang, J.5
Chen, W.6
Lu, H.7
-
19
-
-
84896272016
-
Low-dose CT image reconstruction by adaptive-weighted TV-constrained penalized weighted least-squares approach
-
Jun.
-
Y. Liu, J. Ma, H. Zhang, J. Wang, and Z. Liang, "Low-dose CT image reconstruction by adaptive-weighted TV-constrained penalized weighted least-squares approach," in Proc. 2nd Int. Conf. Image Format. X-Ray Comput. Tomogr., Jun. 2012, pp. 41-45.
-
(2012)
Proc. 2nd Int. Conf. Image Format. X-Ray Comput. Tomogr.
, pp. 41-45
-
-
Liu, Y.1
Ma, J.2
Zhang, H.3
Wang, J.4
Liang, Z.5
-
20
-
-
84870337138
-
Adaptive-weighted total variation minimization for sparse data toward low-dose x-ray computed tomography image reconstruction
-
Nov.
-
Y. Liu, J. Ma, Y. Fan, and Z. Liang, "Adaptive-weighted total variation minimization for sparse data toward low-dose x-ray computed tomography image reconstruction," Phys.Med. Biol., vol. 57, pp. 7923-7956, Nov. 2012.
-
(2012)
Phys.Med. Biol.
, vol.57
, pp. 7923-7956
-
-
Liu, Y.1
Ma, J.2
Fan, Y.3
Liang, Z.4
-
21
-
-
84867561335
-
Low-dose X-ray CT reconstruction via dictionary learning
-
Sep.
-
Q. Xu, H. Yu, X. Mou, L. Zhang, J. Hsieh, and G. Wang, "Low-dose X-ray CT reconstruction via dictionary learning," IEEE Trans. Med. Imag., vol. 31, no. 9, pp. 1682-1697, Sep. 2012.
-
(2012)
IEEE Trans. Med. Imag.
, vol.31
, Issue.9
, pp. 1682-1697
-
-
Xu, Q.1
Yu, H.2
Mou, X.3
Zhang, L.4
Hsieh, J.5
Wang, G.6
-
22
-
-
33645712892
-
Compressed sensing
-
Apr.
-
D. Donoho, "Compressed sensing," IEEE Trans. Inf. Theory, vol. 52, no. 4, pp. 1289-1306, Apr. 2006.
-
(2006)
IEEE Trans. Inf. Theory
, vol.52
, Issue.4
, pp. 1289-1306
-
-
Donoho, D.1
-
23
-
-
70350645492
-
Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms
-
Oct.
-
J. Tang, B. E. Nett, and G. Chen, "Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms," Phys. Med. Biol., vol. 54, pp. 5781-5804, Oct. 2009.
-
(2009)
Phys. Med. Biol.
, vol.54
, pp. 5781-5804
-
-
Tang, J.1
Nett, B.E.2
Chen, G.3
-
24
-
-
78649995122
-
Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT
-
Oct.
-
J. Bian, J. H. Siewerdsen, X. Han, E. Y. Sidky, J. L. Prince, C. A. Pelizzari, and X. Pan, "Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT," Phys. Med. Biol., vol. 55, pp. 6575-6898, Oct. 2010.
-
(2010)
Phys. Med. Biol.
, vol.55
, pp. 6575-6898
-
-
Bian, J.1
Siewerdsen, J.H.2
Han, X.3
Sidky, E.Y.4
Prince, J.L.5
Pelizzari, C.A.6
Pan, X.7
-
25
-
-
37249085775
-
A TV-stokes denoising algorithm
-
Scale Space and Variational Methods in Computer Vision, First International Conference, SSVM 2007, Proceedings
-
T. Rahman, X. Tai, and S. Osher, "A TV-stokes denoising algorithm," in Proc. 1st Int. Conf. Scale Space Variat. Methods Comput. Vis., Jun. 2007, pp. 473-483. (Pubitemid 350269819)
-
(2007)
Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)
, vol.4485
, pp. 473-483
-
-
Rahman, T.1
Tai, X.-C.2
Osher, S.3
-
26
-
-
67349227504
-
Image inpainting using a TV-Stokes equation
-
X. Tai, S. Osher, and R. Holm, "Image inpainting using a TV-Stokes equation," Image Process. Based Partial Differential Equations Math. Visualizat., pp. 3-22, 2007.
-
(2007)
Image Process. Based Partial Differential Equations Math. Visualizat.
, pp. 3-22
-
-
Tai, X.1
Osher, S.2
Holm, R.3
-
27
-
-
0035690734
-
Navier-Stokes, fluid dynamics and image and video inpainting
-
Dec.
-
M. Bertalmio, A. L. Bertozzi, and G. Sapiro, "Navier-Stokes, fluid dynamics and image and video inpainting," in Proc. Conf. Comp. Vis. Pattern Recognit., Dec. 2001, pp. 355-362.
-
(2001)
Proc. Conf. Comp. Vis. Pattern Recognit.
, pp. 355-362
-
-
Bertalmio, M.1
Bertozzi, A.L.2
Sapiro, G.3
-
28
-
-
69049118419
-
Augmented Lagrangian method, dual methods and split Bregman iteration for ROF model
-
Jun.
-
X. Tai and C.Wu, "Augmented Lagrangian method, dual methods and split Bregman iteration for ROF model," in Proc. 2nd Int. Conf. Scale Space Variat. Methods Comput. Vis., Jun. 2009, pp. 502-513.
-
(2009)
Proc. 2nd Int. Conf. Scale Space Variat. Methods Comput. Vis.
, pp. 502-513
-
-
Tai, X.1
Wu, C.2
-
29
-
-
0033295350
-
A nonlinear primal-dual method for total variation-based image restoration
-
T. F. Chan, A. Marquina, and P. Mulet, "A nonlinear primal-dual method for total variation-based image restoration," SIAM J. Sci. Comput., vol. 20, no. 6, pp. 1964-1977, 1999.
-
(1999)
SIAM J. Sci. Comput.
, vol.20
, Issue.6
, pp. 1964-1977
-
-
Chan, T.F.1
Marquina, A.2
Mulet, P.3
-
31
-
-
0021344602
-
Simultaneous algebraic reconstruction technique (SART): A superior implementation of the art algorithm
-
A. Andersen and A. Kak, "Simultaneous algebraic reconstruction technique (SART): A superior implementation of ART," Ultrason. Imag., vol. 6, no. 1, pp. 81-94, Jan. 1984. (Pubitemid 14139189)
-
(1984)
Ultrasonic Imaging
, vol.6
, Issue.1
, pp. 81-94
-
-
Andersen, A.H.1
Kak, A.C.2
-
32
-
-
0035573057
-
Convergence of the simultaneous algebraic reconstruction technique (SART)
-
M. Jiang and G. Wang, "Convergence of the simultaneous algebraic reconstruction technique (SART)," in Conf. Rec. 35th Asilomar Conf.n Signal, Syst. Comput., Nov. 2001, vol. 1, pp. 360-364. (Pubitemid 34244661)
-
(2001)
Conference Record of the Asilomar Conference on Signals, Systems and Computers
, vol.1
, pp. 360-364
-
-
Jiang, M.1
Wang, G.2
-
33
-
-
84883792579
-
A new TV-stokes model with augmented Lagrangian method for image denoising and deconvolution
-
Jun.
-
D. Chen, L. Cheng, and F. Su, "A new TV-stokes model with augmented Lagrangian method for image denoising and deconvolution," J. Sci. Comput., vol. 51, no. 3, pp. 505-526, Jun. 2012.
-
(2012)
J. Sci. Comput.
, vol.51
, Issue.3
, pp. 505-526
-
-
Chen, D.1
Cheng, L.2
Su, F.3
-
34
-
-
0036493909
-
A universal image quality index
-
DOI 10.1109/97.995823, PII S1070990802048198
-
Z. Wang and A. C. Bovik, "A universal image quality index," IEEE Signal Process. Lett., vol. 9, no. 3, pp. 81-84, Mar. 2002. (Pubitemid 34554870)
-
(2002)
IEEE Signal Processing Letters
, vol.9
, Issue.3
, pp. 81-84
-
-
Wang, Z.1
Bovik, A.C.2
-
35
-
-
45749103203
-
Dose reduction for kilovotage cone-beam computed tomography in radiation therapy
-
DOI 10.1088/0031-9155/53/11/009, PII S0031915508683785
-
J. Wang, T. Li, Z. Liang, and L. Xing, "Dose reduction for kilovotage cone-beam CT in radiation therapy," Phys. Med. Biol., vol. 53, pp. 2897-2909, May 2008. (Pubitemid 351868612)
-
(2008)
Physics in Medicine and Biology
, vol.53
, Issue.11
, pp. 2897-2909
-
-
Wang, J.1
Li, T.2
Liang, Z.3
Xing, L.4
-
36
-
-
0032912554
-
Single-slice rebinning method for helical cone-beamCT
-
Feb.
-
F. Noo,M. Defrise, and R. Clackdoyle, "Single-slice rebinning method for helical cone-beamCT," Phys.Med. Biol., vol. 44, pp. 561-570, Feb. 1999.
-
(1999)
Phys.Med. Biol.
, vol.44
, pp. 561-570
-
-
Noo, F.1
Defrise, M.2
Clackdoyle, R.3
-
37
-
-
31744440684
-
Robust uncertainty principles: Exact signal reconstruction from highly incomplete frequency information
-
DOI 10.1109/TIT.2005.862083
-
E. Candès, J. Romberg, and T. Tao, "Robust uncertainty principles: Exact signal reconstruction fromhighly incomplete frequency information," IEEE Trans. Inf. Theory, vol. 52, no. 2, pp. 489-509, Feb. 2006. (Pubitemid 43174093)
-
(2006)
IEEE Transactions on Information Theory
, vol.52
, Issue.2
, pp. 489-509
-
-
Candes, E.J.1
Romberg, J.2
Tao, T.3
|