메뉴 건너뛰기




Volumn 57, Issue 23, 2012, Pages 7923-7956

Adaptive-weighted total variation minimization for sparse data toward low-dose x-ray computed tomography image reconstruction

Author keywords

[No Author keywords available]

Indexed keywords

EDGE PROPERTIES; IMAGE VOXELS; LOW DOSE; MINIMIZATION ALGORITHMS; PHANTOM EXPERIMENT; PIECEWISE CONSTANT; PROJECTION DATA; PROJECTION ONTO CONVEX SETS; QUANTITATIVE STUDY; SPARSE DATA; TOTAL VARIATION; TOTAL VARIATION MINIMIZATION; X-RAY COMPUTED TOMOGRAPHY;

EID: 84870337138     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/57/23/7923     Document Type: Article
Times cited : (317)

References (46)
  • 1
    • 0021344602 scopus 로고
    • Simultaneous algebraic reconstruction technique (SART): A superior implementation of the art algorithm
    • Andersen A and Kak A 1984 Simultaneous algebraic reconstruction technique (SART): asuperior implementation of ART Ultrason. Imaging 6 81-94 (Pubitemid 14139189)
    • (1984) Ultrasonic Imaging , vol.6 , Issue.1 , pp. 81-94
    • Andersen, A.H.1    Kak, A.C.2
  • 3
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography - An increasing source of radiation exposure
    • DOI 10.1056/NEJMra072149
    • Brenner D J and Hall E J 2007 CT - an increasing source of radiation exposure New England J. Med. 357 2277-84 (Pubitemid 350190758)
    • (2007) New England Journal of Medicine , vol.357 , Issue.22 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 4
    • 31744440684 scopus 로고    scopus 로고
    • Robust uncertainty principles: Exact signal reconstruction from highly incomplete frequency information
    • DOI 10.1109/TIT.2005.862083
    • Candès E, Romberg J and Tao T 2006 Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information IEEE Trans. Inform. Theory 52 489-509 (Pubitemid 43174093)
    • (2006) IEEE Transactions on Information Theory , vol.52 , Issue.2 , pp. 489-509
    • Candes, E.J.1    Romberg, J.2    Tao, T.3
  • 5
    • 85032750937 scopus 로고    scopus 로고
    • An introduction to compressive sampling: A sensing/sampling paradigm that goes against the common knowledge in data acquisition
    • DOI 10.1109/MSP.2007.914731
    • Candès E and Wakin M 2008 An introduction to compressive sampling IEEE Signal Process. Mag. 25 21-30 (Pubitemid 351513062)
    • (2008) IEEE Signal Processing Magazine , vol.25 , Issue.2 , pp. 21-30
    • Candes, E.J.1    Wakin, M.B.2
  • 6
    • 38049054399 scopus 로고    scopus 로고
    • Nonlocal prior Bayesian tomographic reconstruction
    • 10.1007/s10851-007-0042-5 0924-9907
    • Chen Y, Ma J, Feng Q, Luo L, Shi P and Chen W 2007 Nonlocal prior Bayesian tomographic reconstruction J. Math. Imaging Vis. 30 133-46
    • (2007) J. Math. Imaging Vis. , vol.30 , Issue.2 , pp. 133-146
    • Chen, Y.1    Ma, J.2    Feng, Q.3    Luo, L.4    Shi, P.5    Chen, W.6
  • 8
    • 79957968770 scopus 로고    scopus 로고
    • An algorithm for total variation regularization in high-dimensional linear problems
    • 065002
    • Dfrise M, Vanhove C and Liu X 2011 An algorithm for total variation regularization in high-dimensional linear problems Inverse Problems 6 065002
    • (2011) Inverse Problems , vol.6
    • Dfrise, M.1    Vanhove, C.2    Liu, X.3
  • 9
    • 33645712892 scopus 로고    scopus 로고
    • Compressed sensing
    • 10.1109/TIT.2006.871582 0018-9448
    • Donoho D 2006 Compressed sensing IEEE Trans. Inform. Theory 52 1289-306
    • (2006) IEEE Trans. Inform. Theory , vol.52 , Issue.4 , pp. 1289-1306
    • Donoho, D.1
  • 10
    • 34447558140 scopus 로고    scopus 로고
    • Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography
    • DOI 10.1001/jama.298.3.317
    • Einstein A J, Henzlova M J and Rajagopalan S 2007 Estimating risk of cancer associated with radiation exposure from 64-slice CT coronary angiography J. Am. Med. Assoc. 298 317-23 (Pubitemid 47080486)
    • (2007) Journal of the American Medical Association , vol.298 , Issue.3 , pp. 317-323
    • Einstein, A.J.1    Henzlova, M.J.2    Rajagopalan, S.3
  • 11
    • 0036462553 scopus 로고    scopus 로고
    • Statistical image reconstruction for polyenergetic X-ray computed tomography
    • DOI 10.1109/42.993128, PII S0278006202029361
    • Elbakri I A and Fessler J A 2002 Statistical image reconstruction for polyenergetic x-ray CT IEEE Trans. Med. Imaging 21 89-99 (Pubitemid 34466423)
    • (2002) IEEE Transactions on Medical Imaging , vol.21 , Issue.2 , pp. 89-99
    • Elbakri, I.A.1    Fessler, J.A.2
  • 12
    • 0042421775 scopus 로고    scopus 로고
    • Efficient and accurate likelihood for iterative image reconstruction in x-ray CT
    • 10.1117/12.480302 0277-786X
    • Elbakri I A and Fessler J A 2003 Efficient and accurate likelihood for iterative image reconstruction in x-ray CT Proc. SPIE 5032 1839-50
    • (2003) Proc. SPIE , vol.5032 , pp. 1839-1850
    • Elbakri, I.A.1    Fessler, J.A.2
  • 13
    • 84862527511 scopus 로고    scopus 로고
    • Implementation of an optimal first-order method for strongly convex total variation regularization
    • 10.1007/s10543-011-0359-8 0006-3835
    • Jensen T L, Jorgensen J H, Hansen P C and Jensen S H 2012 Implementation of an optimal first-order method for strongly convex total variation regularization BIT Numer. Math. 52 329-56
    • (2012) BIT Numer. Math. , vol.52 , Issue.2 , pp. 329-356
    • Jensen, T.L.1    Jorgensen, J.H.2    Hansen, P.C.3    Jensen, S.H.4
  • 15
    • 0020204372 scopus 로고
    • An improved algorithm for reprojecting rays through pixel images
    • 10.1109/TMI.1982.4307572 0278-0062
    • Joseph P M 1982 An improved algorithm for reprojecting rays through pixel images IEEE Trans. Med. Imaging 1 192-6
    • (1982) IEEE Trans. Med. Imaging , vol.1 , Issue.3 , pp. 192-196
    • Joseph, P.M.1
  • 18
    • 33746927954 scopus 로고    scopus 로고
    • Penalized-likelihood sinogram restoration for computed tomography
    • DOI 10.1109/TMI.2006.875429, 1661697
    • La Rivière P J, Bian J and Vargas P A 2006 Penalized-likelihood sinogram restoration for CT IEEE Trans. Med. Imaging 25 1022-36 (Pubitemid 44192174)
    • (2006) IEEE Transactions on Medical Imaging , vol.25 , Issue.8 , pp. 1022-1036
    • La Riviere, P.J.1    Bian, J.2    Vargas, P.A.3
  • 19
    • 34147138229 scopus 로고    scopus 로고
    • Statistical reconstruction for x-ray computed tomography using energy-integrating detectors
    • DOI 10.1088/0031-9155/52/8/014, PII S0031915507341602, 014
    • Lasio G M, Whiting B R and Williamson J F 2007 Statistical reconstruction for x-ray CT using energy-integration detectors Phys. Med. Biol. 52 2247-66 (Pubitemid 46553649)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.8 , pp. 2247-2266
    • Lasio, G.M.1    Whiting, B.R.2    Williamson, J.F.3
  • 21
  • 22
    • 84863391282 scopus 로고    scopus 로고
    • An investigation on CT image reconstruction with compressed sensing by l1 norm prior image constraints
    • Liu Y, Ma J, Fan Y and Liang Z 2011 An investigation on CT image reconstruction with compressed sensing by l1 norm prior image constraints IEEE Nucl. Sci. Symp. and Medical Imaging Conf. Rec. pp 2682-7
    • (2011) IEEE Nucl. Sci. Symp. and Medical Imaging Conf. Rec. , pp. 2682-2687
    • Liu, Y.1    Ma, J.2    Fan, Y.3    Liang, Z.4
  • 24
    • 77953579668 scopus 로고    scopus 로고
    • Generalized Gibbs priors based positron emission tomography reconstruction
    • 10.1016/j.compbiomed.2010.03.012 0010-4825
    • Ma J, Feng Q, Feng Y, Huang J and Chen W 2010 Generalized Gibbs priors based positron emission tomography reconstruction Comput. Biol. Med. 40 565-71
    • (2010) Comput. Biol. Med. , vol.40 , Issue.6 , pp. 565-571
    • Ma, J.1    Feng, Q.2    Feng, Y.3    Huang, J.4    Chen, W.5
  • 25
    • 80053609557 scopus 로고    scopus 로고
    • Low-dose computed tomography image restoration using previous normal-dose scan
    • 10.1118/1.3638125 0094-2405
    • Ma J, Huang J, Feng Q, Zhang H, Lu H, Liang Z and Chen W 2011 Low-dose computed tomography image restoration using previous normal-dose scan Med. Phys. 38 5714-31
    • (2011) Med. Phys. , vol.38 , Issue.10 , pp. 5713-5731
    • Ma, J.1    Huang, J.2    Feng, Q.3    Zhang, H.4    Lu, H.5    Liang, Z.6    Chen, W.7
  • 26
    • 84864264764 scopus 로고    scopus 로고
    • Variance analysis of x-ray CT sonograms in the presence of electronic noise background
    • 10.1118/1.4722751 0094-2405
    • Ma J, Liang Z, Fan Y, Liu Y, Huang J, Chen W and Lu H 2012 Variance analysis of x-ray CT sonograms in the presence of electronic noise background Med. Phys. 39 4051-65
    • (2012) Med. Phys. , vol.39 , Issue.7 , pp. 4051-4065
    • Ma, J.1    Liang, Z.2    Fan, Y.3    Liu, Y.4    Huang, J.5    Chen, W.6    Lu, H.7
  • 29
    • 0023502720 scopus 로고
    • Addition of a channel mechanism to the ideal-observer model
    • 10.1364/JOSAA.4.002447 1084-7529
    • Myers K J and Barrett H H 1987 Addition of a channel mechanism to the ideal-observer model Opt. Soc. Am. 4 2447-57
    • (1987) Opt. Soc. Am. , vol.4 , Issue.12 , pp. 2447-2457
    • Myers, K.J.1    Barrett, H.H.2
  • 30
    • 84864198269 scopus 로고    scopus 로고
    • Accelerated barrier optimization compressed sensing (ABOCS) reconstruction for cone-beam CT: Phantom studies
    • 10.1118/1.4729837 0094-2405
    • Niu T and Zhu L 2012 Accelerated barrier optimization compressed sensing (ABOCS) reconstruction for cone-beam CT: phantom studies Med. Phys. 39 4588-98
    • (2012) Med. Phys. , vol.39 , Issue.7 , pp. 4588-4598
    • Niu, T.1    Zhu, L.2
  • 31
    • 33847771633 scopus 로고    scopus 로고
    • Alternating minimization algorithms for transmission tomography
    • DOI 10.1109/TMI.2006.886806
    • O'Sullivan J A and Benac J 2007 Alternating minimization algorithms for transmission tomography IEEE Trans. Med. Imaging 26 283-97 (Pubitemid 46392338)
    • (2007) IEEE Transactions on Medical Imaging , vol.26 , Issue.3 , pp. 283-297
    • O'Sullivan, J.A.1    Benac, J.2
  • 32
    • 84863229305 scopus 로고    scopus 로고
    • Fast compressed sensing-based CBCT reconstruction using Barzilai-Borwein formulation for application to on-line IGRT
    • 10.1118/1.3679865 0094-2405
    • Park J C, Song B, Kim J S, Liu Z, Suh T S and Song W Y 2012 Fast compressed sensing-based CBCT reconstruction using Barzilai-Borwein formulation for application to on-line IGRT Med. Phys. 39 1207-17
    • (2012) Med. Phys. , vol.39 , Issue.3 , pp. 1207-1217
    • Park, J.C.1    Song, B.2    Kim, J.S.3    Liu, Z.4    Suh, T.S.5    Song, W.Y.6
  • 33
    • 78149449856 scopus 로고    scopus 로고
    • Total variation superiorization schemes in proton CT image reconstruction
    • 10.1118/1.3504603 0094-2405
    • Penfold S, Schulte R, Censor Y and Rosenfeld A 2010 Total variation superiorization schemes in proton CT image reconstruction Med. Phys. 37 5887-95
    • (2010) Med. Phys. , vol.37 , Issue.11 , pp. 5887-5895
    • Penfold, S.1    Schulte, R.2    Censor, Y.3    Rosenfeld, A.4
  • 35
    • 44049111982 scopus 로고
    • Nonlinear total variation based noise removal algorithms
    • 10.1016/0167-2789(92)90242-F 0167-2789 D
    • Ruding L I, Osher S and Fatemi E 1992 Nonlinear total variation based noise removal algorithms Physica D 60 259-68
    • (1992) Physica , vol.60 , Issue.1-4 , pp. 259-268
    • Ruding, L.I.1    Osher, S.2    Fatemi, E.3
  • 36
    • 33745162201 scopus 로고    scopus 로고
    • Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT
    • Sidky E, Kao C and Pan X 2006 Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT J. X-Ray Sci. Technol. 14 119-39 (Pubitemid 43893801)
    • (2006) Journal of X-Ray Science and Technology , vol.14 , Issue.2 , pp. 119-139
    • Sidky, E.Y.1    Kao, C.-M.2    Pan, X.3
  • 37
    • 51849124226 scopus 로고    scopus 로고
    • Image reconstruction in circular cone-beam CT by constrained, total-variation minimization
    • 10.1088/0031-9155/53/17/021 0031-9155
    • Sidky E and Pan X 2008 Image reconstruction in circular cone-beam CT by constrained, total-variation minimization Phys. Med. Biol. 53 4777-807
    • (2008) Phys. Med. Biol. , vol.53 , Issue.17 , pp. 4777-4807
    • Sidky, E.1    Pan, X.2
  • 39
    • 80052667571 scopus 로고    scopus 로고
    • Low-dose CT reconstruction via edge-preserving total variation regularization
    • 10.1088/0031-9155/56/18/011 0031-9155
    • Tian Z, Jia X, Yuan K, Pan T and Jiang S 2011 Low-dose CT reconstruction via edge-preserving total variation regularization Phys. Med. Biol. 56 5949-67
    • (2011) Phys. Med. Biol. , vol.56 , Issue.18 , pp. 5949-5967
    • Tian, Z.1    Jia, X.2    Yuan, K.3    Pan, T.4    Jiang, S.5
  • 40
    • 45749103203 scopus 로고    scopus 로고
    • Dose reduction for kilovotage cone-beam computed tomography in radiation therapy
    • DOI 10.1088/0031-9155/53/11/009, PII S0031915508683785
    • Wang J, Li T, Liang Z and Xing L 2008 Dose reduction for kilovotage cone-beam CT in radiation therapy Phys. Med. Biol. 53 2897-909 (Pubitemid 351868612)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.11 , pp. 2897-2909
    • Wang, J.1    Li, T.2    Liang, Z.3    Xing, L.4
  • 41
    • 33947260155 scopus 로고    scopus 로고
    • Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography
    • DOI 10.1109/TMI.2006.882141
    • Wang J, Li T, Lu H and Liang Z 2006 Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose x-ray CT IEEE Trans. Med. Imaging 25 1272-83 (Pubitemid 46417077)
    • (2006) IEEE Transactions on Medical Imaging , vol.25 , Issue.10 , pp. 1272-1283
    • Wang, J.1    Li, T.2    Lu, H.3    Liang, Z.4
  • 42
    • 0032587718 scopus 로고    scopus 로고
    • Fast spatio-temporal image reconstruction for dynamic PET
    • 10.1109/42.764885 0278-0062
    • Wernick M N, Infusino E J and Milošević M 1999 Fast spatio-temporal image reconstruction for dynamic PET IEEE Trans. Med. Imaging 18 185-95
    • (1999) IEEE Trans. Med. Imaging , vol.18 , Issue.3 , pp. 185-195
    • Wernick, M.N.1    Infusino, E.J.2    Milošević, M.3
  • 44
    • 67349264710 scopus 로고    scopus 로고
    • Electronic noise modeling in statistical iterative reconstruction
    • 10.1109/TIP.2009.2017139 1057-7149
    • Xu J and Tsui B W 2009 Electronic noise modeling in statistical iterative reconstruction IEEE Trans. Image Process. 18 1228-38
    • (2009) IEEE Trans. Image Process. , vol.18 , Issue.6 , pp. 1228-1238
    • Xu, J.1    Tsui, B.W.2
  • 45
    • 84867561335 scopus 로고    scopus 로고
    • Low-dose x-ray CT reconstruction via dictionary learning
    • 10.1109/TMI.2012.2195669 0278-0062
    • Xu Q, Yu H, Mou X, Zhang L, Hsieh J and Wang G 2012 Low-dose x-ray CT reconstruction via dictionary learning IEEE Trans. Med. Imaging 31 1682-97
    • (2012) IEEE Trans. Med. Imaging , vol.31 , Issue.9 , pp. 1682-1697
    • Xu, Q.1    Yu, H.2    Mou, X.3    Zhang, L.4    Hsieh, J.5    Wang, G.6
  • 46
    • 67649892573 scopus 로고    scopus 로고
    • Compressed sensing based interior tomography
    • 10.1088/0031-9155/54/9/014 0031-9155
    • Yu H and Wang G 2009 Compressed sensing based interior tomography Phys. Med. Biol. 54 2791-805
    • (2009) Phys. Med. Biol. , vol.54 , Issue.9 , pp. 2791-2805
    • Yu, H.1    Wang, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.