메뉴 건너뛰기




Volumn 97, Issue , 2014, Pages 23-33

Modeling MIC copper release from drinking water pipes

Author keywords

Biofilm modeling; Cellular automata; Copper; Hydrodynamics; MIC

Indexed keywords

BIOFILMS; CELLULAR AUTOMATA; COPPER PIPE; CORROSION; HYDRODYNAMICS; MATHEMATICAL MODELS; MODELS; RESERVOIRS (WATER); WATER PIPELINES;

EID: 84895924139     PISSN: 15675394     EISSN: 1878562X     Source Type: Journal    
DOI: 10.1016/j.bioelechem.2013.12.004     Document Type: Article
Times cited : (16)

References (60)
  • 2
    • 0018001151 scopus 로고
    • Pitting Corrosion of Copper Tubes and Carbon Deposits: ESCS Studies
    • Callot P., Jaegle A., Kalt A., Nanse G. Pitting Corrosion of Copper Tubes and Carbon Deposits: ESCS Studies. Werkst. Korros. 1987, 29:519-522.
    • (1987) Werkst. Korros. , vol.29 , pp. 519-522
    • Callot, P.1    Jaegle, A.2    Kalt, A.3    Nanse, G.4
  • 5
    • 0035255252 scopus 로고    scopus 로고
    • Role of temperature, chlorine, and organic matter in copper corrosion by-product release in soft water
    • Boulay N., Edwards M. Role of temperature, chlorine, and organic matter in copper corrosion by-product release in soft water. Water Res. 2001, 35:683-690.
    • (2001) Water Res. , vol.35 , pp. 683-690
    • Boulay, N.1    Edwards, M.2
  • 7
  • 8
    • 1342305475 scopus 로고    scopus 로고
    • The physico-chemistry of biofilm-mediated pitting corrosion of copper pipe supplying potable water
    • Keevil C.W. The physico-chemistry of biofilm-mediated pitting corrosion of copper pipe supplying potable water. Water Sci. Technol. 2004, 49:91-98.
    • (2004) Water Sci. Technol. , vol.49 , pp. 91-98
    • Keevil, C.W.1
  • 9
    • 0036473085 scopus 로고    scopus 로고
    • Effect of specific water quality parameters on copper corrosion
    • Pehkonen S.O., Palit A., Zhang X. Effect of specific water quality parameters on copper corrosion. Corrosion 2002, 58:156-165.
    • (2002) Corrosion , vol.58 , pp. 156-165
    • Pehkonen, S.O.1    Palit, A.2    Zhang, X.3
  • 12
    • 77955515008 scopus 로고    scopus 로고
    • Increase of the concentration of dissolved copper in drinking water systems due to flow-induced nanoparticle release from surface corrosion by-products
    • Vargas I.T., Pavissich J.P., Olivares T.E., Jeria G.A., Cienfuegos R.A., Pasten P.A., Pizarro G.E. Increase of the concentration of dissolved copper in drinking water systems due to flow-induced nanoparticle release from surface corrosion by-products. Corros. Sci. 2010, 52:3492-3503.
    • (2010) Corros. Sci. , vol.52 , pp. 3492-3503
    • Vargas, I.T.1    Pavissich, J.P.2    Olivares, T.E.3    Jeria, G.A.4    Cienfuegos, R.A.5    Pasten, P.A.6    Pizarro, G.E.7
  • 13
    • 0029195567 scopus 로고
    • Indicators for microbiologically induced corrosion of copper pipes in a cold water plumbing system
    • Arens P., Tuschewitzki G.J., Wollmann H., Follner H., Jacobi H. Indicators for microbiologically induced corrosion of copper pipes in a cold water plumbing system. Int. J. Hyg. Environ. Health 1995, 196:444-454.
    • (1995) Int. J. Hyg. Environ. Health , vol.196 , pp. 444-454
    • Arens, P.1    Tuschewitzki, G.J.2    Wollmann, H.3    Follner, H.4    Jacobi, H.5
  • 14
  • 16
    • 0029767164 scopus 로고    scopus 로고
    • Experiments for stimulating microbiologically induced corrosion of copper pipes in a cold-water plumbing system
    • Arens P., Tuschewitzki G.J., Follner M., Jacobi H., Leuner S. Experiments for stimulating microbiologically induced corrosion of copper pipes in a cold-water plumbing system. Mater. Corros. 1996, 47:96-102.
    • (1996) Mater. Corros. , vol.47 , pp. 96-102
    • Arens, P.1    Tuschewitzki, G.J.2    Follner, M.3    Jacobi, H.4    Leuner, S.5
  • 17
    • 0030671353 scopus 로고    scopus 로고
    • Microbiologically influenced copper corrosion in potable water with emphasis on practical relevance
    • Wagner D., Chamberlain A.H.L. Microbiologically influenced copper corrosion in potable water with emphasis on practical relevance. Biodegradation 1997, 8:177-187.
    • (1997) Biodegradation , vol.8 , pp. 177-187
    • Wagner, D.1    Chamberlain, A.H.L.2
  • 18
    • 77955509493 scopus 로고    scopus 로고
    • Culture dependent and independent analyses of bacterial communities involved in copper plumbing corrosion
    • Pavissich J.P., Vargas I.T., Gonzalez B., Pasten P.A., Pizarro G.E. Culture dependent and independent analyses of bacterial communities involved in copper plumbing corrosion. J. Appl. Microbiol. 2010, 109:771-782.
    • (2010) J. Appl. Microbiol. , vol.109 , pp. 771-782
    • Pavissich, J.P.1    Vargas, I.T.2    Gonzalez, B.3    Pasten, P.A.4    Pizarro, G.E.5
  • 19
    • 0022660407 scopus 로고
    • Role of bacterial exopolymers in the deterioration of metallic copper surfaces
    • Geesey G.G., Mittelman M.W., Iwaoka T., Griffiths P.R. Role of bacterial exopolymers in the deterioration of metallic copper surfaces. Mater. Perform. 1986, 25:37.
    • (1986) Mater. Perform. , vol.25 , pp. 37
    • Geesey, G.G.1    Mittelman, M.W.2    Iwaoka, T.3    Griffiths, P.R.4
  • 20
    • 0037223385 scopus 로고    scopus 로고
    • The influence of the chemical composition of drinking water on cuprosolvency by biofilm bacteria
    • Critchley M.M., Cromar N.J., McClure N.C., Fallowfield H.J. The influence of the chemical composition of drinking water on cuprosolvency by biofilm bacteria. J. Appl. Microbiol. 2003, 94:501-507.
    • (2003) J. Appl. Microbiol. , vol.94 , pp. 501-507
    • Critchley, M.M.1    Cromar, N.J.2    McClure, N.C.3    Fallowfield, H.J.4
  • 21
    • 0031656927 scopus 로고    scopus 로고
    • Assessment of microbial involvement in the elevation of copper levels in drinking water
    • Dutkiewicz C., Fallowfield H.J. Assessment of microbial involvement in the elevation of copper levels in drinking water. J. Appl. Microbiol. 1998, 85:597-602.
    • (1998) J. Appl. Microbiol. , vol.85 , pp. 597-602
    • Dutkiewicz, C.1    Fallowfield, H.J.2
  • 22
    • 77954865769 scopus 로고    scopus 로고
    • Empirical model for dissolved oxygen depletion during corrosion of drinking water copper pipes
    • Vargas I.T., Pasten P.A., Pizarro G.E. Empirical model for dissolved oxygen depletion during corrosion of drinking water copper pipes. Corros. Sci. 2010, 52:2250-2257.
    • (2010) Corros. Sci. , vol.52 , pp. 2250-2257
    • Vargas, I.T.1    Pasten, P.A.2    Pizarro, G.E.3
  • 23
    • 33845583889 scopus 로고    scopus 로고
    • General corrosion of copper in domestic drinking water installations: scientific background and mechanistic understanding
    • Merkel T.H., Pehkonen S.O. General corrosion of copper in domestic drinking water installations: scientific background and mechanistic understanding. Corros. Eng. Sci. Technol. 2006, 41:21-37.
    • (2006) Corros. Eng. Sci. Technol. , vol.41 , pp. 21-37
    • Merkel, T.H.1    Pehkonen, S.O.2
  • 24
    • 1342326760 scopus 로고    scopus 로고
    • Copper corrosion: understanding and modelling general corrosion
    • Merkel T.H. Copper corrosion: understanding and modelling general corrosion. Water Sci. Technol. 2004, 49:63-71.
    • (2004) Water Sci. Technol. , vol.49 , pp. 63-71
    • Merkel, T.H.1
  • 25
    • 19744369761 scopus 로고    scopus 로고
    • Pitting corrosion of copper tubes in soft drinking waters: corrosion mechanism
    • Harrison D.B., Nicholas D.M., Evans G.M. Pitting corrosion of copper tubes in soft drinking waters: corrosion mechanism. J. Am. Water Works Ass. 2004, 96:67-76.
    • (2004) J. Am. Water Works Ass. , vol.96 , pp. 67-76
    • Harrison, D.B.1    Nicholas, D.M.2    Evans, G.M.3
  • 26
    • 0034746488 scopus 로고    scopus 로고
    • Organic matter and copper corrosion by-product release: a mechanistic study
    • Edwards M., Sprague N. Organic matter and copper corrosion by-product release: a mechanistic study. Corros. Sci. 2001, 43:1-18.
    • (2001) Corros. Sci. , vol.43 , pp. 1-18
    • Edwards, M.1    Sprague, N.2
  • 27
    • 0006428267 scopus 로고
    • Copper corrosion II. Kinetic studies
    • Ives D.J.G., Rawson A.E. Copper corrosion II. Kinetic studies. J. Electrochem. Soc. 1962, 109:452-457.
    • (1962) J. Electrochem. Soc. , vol.109 , pp. 452-457
    • Ives, D.J.G.1    Rawson, A.E.2
  • 28
    • 0038654717 scopus 로고
    • Copper corrosion III. Electrochemical theory of general corrosion
    • Ives D.J.G., Rawson A.E. Copper corrosion III. Electrochemical theory of general corrosion. J. Electrochem. Soc. 1962, 109:458-462.
    • (1962) J. Electrochem. Soc. , vol.109 , pp. 458-462
    • Ives, D.J.G.1    Rawson, A.E.2
  • 29
    • 4344701045 scopus 로고    scopus 로고
    • Modeling biofilms
    • ASM Press, Washington D.C. M.A. Ghannoum, G.A. O'Toole (Eds.)
    • Noguera D.R., Pizarro G.E., Regan J.M. Modeling biofilms. Microbial Biofilms 2004, 222-249. ASM Press, Washington D.C. M.A. Ghannoum, G.A. O'Toole (Eds.).
    • (2004) Microbial Biofilms , pp. 222-249
    • Noguera, D.R.1    Pizarro, G.E.2    Regan, J.M.3
  • 30
    • 22744458324 scopus 로고    scopus 로고
    • A framework for multidimensional modelling of activity and structure of multispecies biofilms
    • Xavier J.B., Picioreanu C., van Loosdrecht M.C.M. A framework for multidimensional modelling of activity and structure of multispecies biofilms. Environ. Microbiol. 2005, 7:1085-1103.
    • (2005) Environ. Microbiol. , vol.7 , pp. 1085-1103
    • Xavier, J.B.1    Picioreanu, C.2    van Loosdrecht, M.C.M.3
  • 32
    • 0142011070 scopus 로고    scopus 로고
    • A three-dimensional, stochastic simulation of biofilm growth and transport-related factors that affect structure
    • Chang I., Gilbert E.S., Eliashberg N., Keasling J.D. A three-dimensional, stochastic simulation of biofilm growth and transport-related factors that affect structure. Microbiology (SGM) 2003, 149:2859-2871.
    • (2003) Microbiology (SGM) , vol.149 , pp. 2859-2871
    • Chang, I.1    Gilbert, E.S.2    Eliashberg, N.3    Keasling, J.D.4
  • 34
  • 35
    • 0028439536 scopus 로고
    • Effects of biofilm structures on oxygen distribution and mass transport
    • de Beer D., Stoodley P., Roe F., Lewandowski Z. Effects of biofilm structures on oxygen distribution and mass transport. Biotechnol. Bioeng. 1994, 43:1131-1138.
    • (1994) Biotechnol. Bioeng. , vol.43 , pp. 1131-1138
    • de Beer, D.1    Stoodley, P.2    Roe, F.3    Lewandowski, Z.4
  • 36
    • 0347065238 scopus 로고    scopus 로고
    • Relation between extracellular polymers' composition and its ability to complex Cd, Cu and Pb
    • Guibaud G., Tixier N., Bouju A., Baudu M. Relation between extracellular polymers' composition and its ability to complex Cd, Cu and Pb. Chemosphere 2003, 52:1701-1710.
    • (2003) Chemosphere , vol.52 , pp. 1701-1710
    • Guibaud, G.1    Tixier, N.2    Bouju, A.3    Baudu, M.4
  • 37
  • 38
    • 0010066917 scopus 로고
    • Copper corrosion I. Thermodynamic aspects
    • Ives D.J.G., Rawson A.E. Copper corrosion I. Thermodynamic aspects. J. Electrochem. Soc. 1962, 109:447-451.
    • (1962) J. Electrochem. Soc. , vol.109 , pp. 447-451
    • Ives, D.J.G.1    Rawson, A.E.2
  • 43
    • 0032485575 scopus 로고    scopus 로고
    • Mathematical modeling of biofilm structure with a hybrid differential-discrete cellular automaton approach
    • Picioreanu C., van Loosdrecht M.C.M., Heijnen J.J. Mathematical modeling of biofilm structure with a hybrid differential-discrete cellular automaton approach. Biotechnol. Bioeng. 1998, 58:101-116.
    • (1998) Biotechnol. Bioeng. , vol.58 , pp. 101-116
    • Picioreanu, C.1    van Loosdrecht, M.C.M.2    Heijnen, J.J.3
  • 44
    • 0000870032 scopus 로고
    • The fantastic combinations of John Conway's new solitaire game "Life"
    • Gardner M. The fantastic combinations of John Conway's new solitaire game "Life". Sci. Am. 1970, 223:120-123.
    • (1970) Sci. Am. , vol.223 , pp. 120-123
    • Gardner, M.1
  • 45
    • 23244442896 scopus 로고    scopus 로고
    • Bitwise implementation of a two-dimensional cellular automata biofilm model
    • Pizarro G.E., Teixeira J., Sepulveda M., Noguera D.R. Bitwise implementation of a two-dimensional cellular automata biofilm model. J. Comput. Civ. Eng. 2005, 19:258-268.
    • (2005) J. Comput. Civ. Eng. , vol.19 , pp. 258-268
    • Pizarro, G.E.1    Teixeira, J.2    Sepulveda, M.3    Noguera, D.R.4
  • 46
    • 37248999314 scopus 로고    scopus 로고
    • Distributed simulation with cellular automata using the multispin coding technique
    • Sepulveda M., Moreno R., Pizarro G.E. Distributed simulation with cellular automata using the multispin coding technique. J. Comput. Civ. Eng. 2008, 22:50-57.
    • (2008) J. Comput. Civ. Eng. , vol.22 , pp. 50-57
    • Sepulveda, M.1    Moreno, R.2    Pizarro, G.E.3
  • 48
    • 4544302864 scopus 로고    scopus 로고
    • In situ X-ray absorption study of copper-surface complexes: microbial influenced oxidation of metallic copper
    • Paradies H., Thies M., Ulroke H. In situ X-ray absorption study of copper-surface complexes: microbial influenced oxidation of metallic copper. Rigaku J. 1996, 13:16-22.
    • (1996) Rigaku J. , vol.13 , pp. 16-22
    • Paradies, H.1    Thies, M.2    Ulroke, H.3
  • 54
    • 2442611890 scopus 로고    scopus 로고
    • Dielectric Constant and Density of Water as a Function of Pressure at Constant Temperature
    • Floriano W.B., Chaer M.A. Dielectric Constant and Density of Water as a Function of Pressure at Constant Temperature. Braz. J. Phys. 2004, 34:38-41.
    • (2004) Braz. J. Phys. , vol.34 , pp. 38-41
    • Floriano, W.B.1    Chaer, M.A.2
  • 57
    • 0019209729 scopus 로고
    • Model of steady-state-biofilm kinetics
    • Rittmann B.E., McCarty P.L. Model of steady-state-biofilm kinetics. Biotechnol. Bioeng. 1980, 22:2343-2357.
    • (1980) Biotechnol. Bioeng. , vol.22 , pp. 2343-2357
    • Rittmann, B.E.1    McCarty, P.L.2
  • 59
    • 0036832851 scopus 로고    scopus 로고
    • Copper corrosion in mildly alkaline water with the disinfectant monochloramine
    • Zhang X., Pehkonen S.O., Kocherginsky N., Andrew Ellis G. Copper corrosion in mildly alkaline water with the disinfectant monochloramine. Corros. Sci. 2002, 44:2507.
    • (2002) Corros. Sci. , vol.44 , pp. 2507
    • Zhang, X.1    Pehkonen, S.O.2    Kocherginsky, N.3    Andrew Ellis, G.4
  • 60
    • 0031171983 scopus 로고    scopus 로고
    • Copper corrosion in drinking water distribution systems-the influence of water quality
    • Broo A.E., Berghult B., Hedberg T. Copper corrosion in drinking water distribution systems-the influence of water quality. Corros. Sci. 1997, 39:1119-1132.
    • (1997) Corros. Sci. , vol.39 , pp. 1119-1132
    • Broo, A.E.1    Berghult, B.2    Hedberg, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.