Audiovisual feedback device use by health care professionals during CPR: A systematic review and meta-analysis of randomised and non-randomised trials

Author keywords

Cardiac arrest; Cardiopulmonary resuscitation; Feedback device

Indexed keywords

AUDIOVISUAL EQUIPMENT; CINAHL; COMPRESSION; CPR FEEDBACK DEVICE; CPR MANIKIN; HEALTH CARE PERSONNEL; HEALTH CARE QUALITY; HEART ARREST; HOSPITAL DISCHARGE; HUMAN; INTERVENTION STUDY; MEDLINE; META ANALYSIS (TOPIC); OUTCOME ASSESSMENT; PRIORITY JOURNAL; QUALITY CONTROL; RANDOMIZED CONTROLLED TRIAL (TOPIC); RESUSCITATION; REVIEW; SURVIVAL; SYSTEMATIC REVIEW; TREATMENT OUTCOME; CLINICAL TRIAL (TOPIC); DEVICES; META ANALYSIS; MORTALITY; SENSORY FEEDBACK;

EID: 84895923112     PISSN: 03009572     EISSN: 18731570     Source Type: Journal    
DOI: 10.1016/j.resuscitation.2013.12.012     Document Type: Review
Times cited : (144)

References (51)
  • 1
    • 79851476464 scopus 로고    scopus 로고
    • Systematic review of the incidence of sudden cardiac death in the United States
    • Kong M.H., Fonarow G.C., Peterson E.D., et al. Systematic review of the incidence of sudden cardiac death in the United States. J Am Coll Cardiol 2011, 57:794-801.
    • (2011) J Am Coll Cardiol , vol.57 , pp. 794-801
    • Kong, M.H.1    Fonarow, G.C.2    Peterson, E.D.3
  • 2
    • 78149413588 scopus 로고    scopus 로고
    • Global incidences of out-of-hospital cardiac arrest and survival rates: systematic review of 67 prospective studies
    • Berdowski J., Berg R.A., Tijssen J.G.P., Koster R.W. Global incidences of out-of-hospital cardiac arrest and survival rates: systematic review of 67 prospective studies. Resuscitation 2010, 81:1479-1487.
    • (2010) Resuscitation , vol.81 , pp. 1479-1487
    • Berdowski, J.1    Berg, R.A.2    Tijssen, J.G.P.3    Koster, R.W.4
  • 3
    • 52449090787 scopus 로고    scopus 로고
    • Regional variation in out-of-hospital cardiac arrest incidence and outcome
    • Nichol G., Thomas E., Callaway C.W., et al. Regional variation in out-of-hospital cardiac arrest incidence and outcome. JAMA: J Am Med Assoc 2008, 300:1423-1431.
    • (2008) JAMA: J Am Med Assoc , vol.300 , pp. 1423-1431
    • Nichol, G.1    Thomas, E.2    Callaway, C.W.3
  • 4
    • 79952277951 scopus 로고    scopus 로고
    • Part 1: Executive summary: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations
    • Nolan J.P., Hazinski M.F., Billi J.E., et al. Part 1: Executive summary: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations. Resuscitation 2010, 81:e1-e25.
    • (2010) Resuscitation , vol.81
    • Nolan, J.P.1    Hazinski, M.F.2    Billi, J.E.3
  • 5
    • 0025805613 scopus 로고
    • Improving survival from sudden cardiac arrest: the "chain of survival" concept. A statement for health professionals from the Advanced Cardiac Life Support Subcommittee and the Emergency Cardiac Care Committee, American Heart Association
    • Cummins R.O., Ornato J.P., Thies W.H., Pepe P.E. Improving survival from sudden cardiac arrest: the "chain of survival" concept. A statement for health professionals from the Advanced Cardiac Life Support Subcommittee and the Emergency Cardiac Care Committee, American Heart Association. Circulation 1991, 83:1832-1847.
    • (1991) Circulation , vol.83 , pp. 1832-1847
    • Cummins, R.O.1    Ornato, J.P.2    Thies, W.H.3    Pepe, P.E.4
  • 6
  • 7
    • 0035856551 scopus 로고    scopus 로고
    • Adverse hemodynamic effects of interrupting chest compressions for rescue breathing during cardiopulmonary resuscitation for ventricular fibrillation cardiac arrest
    • Berg R.A., Sanders A.B., Kern K.B., et al. Adverse hemodynamic effects of interrupting chest compressions for rescue breathing during cardiopulmonary resuscitation for ventricular fibrillation cardiac arrest. Circulation 2001, 104:2465-2470.
    • (2001) Circulation , vol.104 , pp. 2465-2470
    • Berg, R.A.1    Sanders, A.B.2    Kern, K.B.3
  • 8
    • 0037022212 scopus 로고    scopus 로고
    • Importance of continuous chest compressions during cardiopulmonary resuscitation
    • Kern K.B., Hilwig R.W., Berg R.A., Sanders A.B., Ewy G.A. Importance of continuous chest compressions during cardiopulmonary resuscitation. Circulation 2002, 105:645-649.
    • (2002) Circulation , vol.105 , pp. 645-649
    • Kern, K.B.1    Hilwig, R.W.2    Berg, R.A.3    Sanders, A.B.4    Ewy, G.A.5
  • 9
    • 0037076435 scopus 로고    scopus 로고
    • Effects of interrupting precordial compressions on the calculated probability of defibrillation success during out-of-hospital cardiac arrest
    • Eftestøl T., Sunde K., Steen P.A. Effects of interrupting precordial compressions on the calculated probability of defibrillation success during out-of-hospital cardiac arrest. Circulation 2002, 105:2270-2273.
    • (2002) Circulation , vol.105 , pp. 2270-2273
    • Eftestøl, T.1    Sunde, K.2    Steen, P.A.3
  • 10
    • 33751254313 scopus 로고    scopus 로고
    • Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: a prospective interventional study
    • Kramer-Johansen J., Myklebust H., Wik L., et al. Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: a prospective interventional study. Resuscitation 2006, 71:283-292.
    • (2006) Resuscitation , vol.71 , pp. 283-292
    • Kramer-Johansen, J.1    Myklebust, H.2    Wik, L.3
  • 11
    • 70349673319 scopus 로고    scopus 로고
    • Chest compression fraction determines survival in patients with out-of-hospital ventricular fibrillation
    • Christenson J., Andrusiek D., Everson-Stewart S., et al. Chest compression fraction determines survival in patients with out-of-hospital ventricular fibrillation. Circulation 2009, 120:1241-1247.
    • (2009) Circulation , vol.120 , pp. 1241-1247
    • Christenson, J.1    Andrusiek, D.2    Everson-Stewart, S.3
  • 12
    • 12244295495 scopus 로고    scopus 로고
    • Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest
    • Wik L., Kramer-Johansen J., Myklebust H., et al. Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest. JAMA 2005, 293:299-304.
    • (2005) JAMA , vol.293 , pp. 299-304
    • Wik, L.1    Kramer-Johansen, J.2    Myklebust, H.3
  • 13
    • 67349166152 scopus 로고    scopus 로고
    • The use of CPR feedback/prompt devices during training and CPR performance: a systematic review
    • Yeung J., Meeks R., Edelson D., Gao F., Soar J., Perkins G.D. The use of CPR feedback/prompt devices during training and CPR performance: a systematic review. Resuscitation 2009, 80:743-751.
    • (2009) Resuscitation , vol.80 , pp. 743-751
    • Yeung, J.1    Meeks, R.2    Edelson, D.3    Gao, F.4    Soar, J.5    Perkins, G.D.6
  • 14
    • 79751531242 scopus 로고    scopus 로고
    • The addition of voice prompts to audiovisual feedback and debriefing does not modify CPR quality or outcomes in out of hospital cardiac arrest-a prospective, randomized trial
    • Bohn A., Weber T.P., Wecker S., et al. The addition of voice prompts to audiovisual feedback and debriefing does not modify CPR quality or outcomes in out of hospital cardiac arrest-a prospective, randomized trial. Resuscitation 2011, 82:257-262.
    • (2011) Resuscitation , vol.82 , pp. 257-262
    • Bohn, A.1    Weber, T.P.2    Wecker, S.3
  • 15
    • 34848914317 scopus 로고    scopus 로고
    • A failed attempt to improve quality of out-of-hospital CPR through performance evaluation
    • [Date of Publication: October 2007]
    • Olasveengen T.M., Tomlinson A.E., Wik L., et al. A failed attempt to improve quality of out-of-hospital CPR through performance evaluation. Prehosp Emerg Care 2007, 11:427-433. [Date of Publication: October 2007].
    • (2007) Prehosp Emerg Care , vol.11 , pp. 427-433
    • Olasveengen, T.M.1    Tomlinson, A.E.2    Wik, L.3
  • 16
    • 79951663161 scopus 로고    scopus 로고
    • Effect of real-time feedback during cardiopulmonary resuscitation outside hospital: prospective, cluster-randomised trial
    • Hostler D., Everson-Stewart S., Rea T.D., et al. Effect of real-time feedback during cardiopulmonary resuscitation outside hospital: prospective, cluster-randomised trial. BMJ 2011, 2011.
    • (2011) BMJ , pp. 2011
    • Hostler, D.1    Everson-Stewart, S.2    Rea, T.D.3
  • 17
    • 84895923428 scopus 로고    scopus 로고
    • Effect of real-time automated and delayed summative feedback on CPR quality in adult out-of-hospital cardiac arrest: a prospective multicenter controlled clinical trial
    • Chandra S., Hess E.P., Kolb L., Myers L., White R.D. Effect of real-time automated and delayed summative feedback on CPR quality in adult out-of-hospital cardiac arrest: a prospective multicenter controlled clinical trial. Acad Emerg Med 2011, 15:S6-S145.
    • (2011) Acad Emerg Med , vol.15
    • Chandra, S.1    Hess, E.P.2    Kolb, L.3    Myers, L.4    White, R.D.5
  • 18
    • 84895922624 scopus 로고    scopus 로고
    • A randomised controlled trial of prompt and feedback devices and its impact on quality of chest compressions in Immediate Life Support (ILS) training
    • Yeung J., Perkins G. A randomised controlled trial of prompt and feedback devices and its impact on quality of chest compressions in Immediate Life Support (ILS) training. Resuscitation 2011, 82:S11.
    • (2011) Resuscitation , vol.82
    • Yeung, J.1    Perkins, G.2
  • 19
    • 79957843047 scopus 로고    scopus 로고
    • Effects and limitations of an AED with audiovisual feedback for cardiopulmonary resuscitation: a randomized manikin study
    • Fischer H., Gruber J., Neuhold S., et al. Effects and limitations of an AED with audiovisual feedback for cardiopulmonary resuscitation: a randomized manikin study. Resuscitation 2011, 82:902-907.
    • (2011) Resuscitation , vol.82 , pp. 902-907
    • Fischer, H.1    Gruber, J.2    Neuhold, S.3
  • 20
    • 84857408653 scopus 로고    scopus 로고
    • Effect of feedback on delaying deterioration in quality of compressions during 2minutes of continuous chest compressions: a randomized manikin study investigating performance with and without feedback
    • Lyngeraa T.S., Hjortrup P.B., Wulff N.B., Aagaard T., Lippert A. Effect of feedback on delaying deterioration in quality of compressions during 2minutes of continuous chest compressions: a randomized manikin study investigating performance with and without feedback. Scand J Trauma Resusc Emerg Med 2012, 20:16.
    • (2012) Scand J Trauma Resusc Emerg Med , vol.20 , pp. 16
    • Lyngeraa, T.S.1    Hjortrup, P.B.2    Wulff, N.B.3    Aagaard, T.4    Lippert, A.5
  • 21
    • 79959469301 scopus 로고    scopus 로고
    • Cardiopulmonary resuscitation feedback improves the quality of chest compression provided by hospital health care professionals
    • Pozner C.N., Almozlino A., Elmer J., Poole S., McNamara D., Barash D. Cardiopulmonary resuscitation feedback improves the quality of chest compression provided by hospital health care professionals. Am J Emerg Med 2011, 29:618-625.
    • (2011) Am J Emerg Med , vol.29 , pp. 618-625
    • Pozner, C.N.1    Almozlino, A.2    Elmer, J.3    Poole, S.4    McNamara, D.5    Barash, D.6
  • 22
    • 72049110223 scopus 로고    scopus 로고
    • New visual feedback device improves performance of chest compressions by professionals in simulated cardiac arrest
    • Skorning M., Beckers S.K., Brokmann J.C., et al. New visual feedback device improves performance of chest compressions by professionals in simulated cardiac arrest. Resuscitation 2010, 81:53-58.
    • (2010) Resuscitation , vol.81 , pp. 53-58
    • Skorning, M.1    Beckers, S.K.2    Brokmann, J.C.3
  • 23
    • 72149114592 scopus 로고    scopus 로고
    • Quality of closed chest compression on a manikin in ambulance vehicles and flying helicopters with a real time automated feedback
    • Havel C., Schreiber W., Trimmel H., et al. Quality of closed chest compression on a manikin in ambulance vehicles and flying helicopters with a real time automated feedback. Resuscitation 2010, 81:59-64.
    • (2010) Resuscitation , vol.81 , pp. 59-64
    • Havel, C.1    Schreiber, W.2    Trimmel, H.3
  • 25
    • 67349162964 scopus 로고    scopus 로고
    • Strengthening the reporting of observational studies in epidemiology (STROBE): explanation and elaboration
    • Vandenbroucke J.P., Von Elm E., Altman D.G., et al. Strengthening the reporting of observational studies in epidemiology (STROBE): explanation and elaboration. Gac Sanit 2009, 23:26.
    • (2009) Gac Sanit , vol.23 , pp. 26
    • Vandenbroucke, J.P.1    Von Elm, E.2    Altman, D.G.3
  • 29
    • 68049137869 scopus 로고    scopus 로고
    • The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration
    • Liberati A., Altman D.G., Tetzlaff J., et al. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. PLoS Med 2009, 6:e1000100.
    • (2009) PLoS Med , vol.6
    • Liberati, A.1    Altman, D.G.2    Tetzlaff, J.3
  • 31
    • 33847383005 scopus 로고    scopus 로고
    • CPR quality improvement during in-hospital cardiac arrest using a real-time audiovisual feedback system
    • Abella B.S., Edelson D.P., Kim S., et al. CPR quality improvement during in-hospital cardiac arrest using a real-time audiovisual feedback system. Resuscitation 2007, 73:54-61.
    • (2007) Resuscitation , vol.73 , pp. 54-61
    • Abella, B.S.1    Edelson, D.P.2    Kim, S.3
  • 32
    • 33845415871 scopus 로고    scopus 로고
    • CPREzy improves performance of external chest compressions in simulated cardiac arrest
    • Beckers S.K., Skorning M.H., Fries M., et al. CPREzy improves performance of external chest compressions in simulated cardiac arrest. Resuscitation 2007, 72:100-107.
    • (2007) Resuscitation , vol.72 , pp. 100-107
    • Beckers, S.K.1    Skorning, M.H.2    Fries, M.3
  • 33
    • 0036296601 scopus 로고    scopus 로고
    • Improvement in timing and effectiveness of external cardiac compressions with a new non-invasive device: the CPR-Ezy
    • Boyle A.J., Wilson A.M., Connelly K., McGuigan L., Wilson J., Whitbourn R. Improvement in timing and effectiveness of external cardiac compressions with a new non-invasive device: the CPR-Ezy. Resuscitation 2002, 54:63-67.
    • (2002) Resuscitation , vol.54 , pp. 63-67
    • Boyle, A.J.1    Wilson, A.M.2    Connelly, K.3    McGuigan, L.4    Wilson, J.5    Whitbourn, R.6
  • 34
    • 33646154863 scopus 로고    scopus 로고
    • The quality of chest compressions by trained personnel: the effect of feedback, via the CPREzy, in a randomized controlled trial using a manikin model
    • Noordergraaf G.J., Drinkwaard B.W.P.M., van Berkom P.F.J., et al. The quality of chest compressions by trained personnel: the effect of feedback, via the CPREzy, in a randomized controlled trial using a manikin model. Resuscitation 2006, 69:241-252.
    • (2006) Resuscitation , vol.69 , pp. 241-252
    • Noordergraaf, G.J.1    Drinkwaard, B.W.P.M.2    van Berkom, P.F.J.3
  • 35
    • 11144332045 scopus 로고    scopus 로고
    • CPREzy™: an evaluation during simulated cardiac arrest on a hospital bed
    • Perkins G.D., Augré C., Rogers H., Allan M., Thickett D.R. CPREzy™: an evaluation during simulated cardiac arrest on a hospital bed. Resuscitation 2005, 64:103-108.
    • (2005) Resuscitation , vol.64 , pp. 103-108
    • Perkins, G.D.1    Augré, C.2    Rogers, H.3    Allan, M.4    Thickett, D.R.5
  • 36
    • 80054759037 scopus 로고    scopus 로고
    • External chest compressions using a mechanical feedback device: cross-over simulation study
    • Skorning M., Derwall M., Brokmann J.C., et al. External chest compressions using a mechanical feedback device: cross-over simulation study. Anaesthesist 2011, 60:717-722.
    • (2011) Anaesthesist , vol.60 , pp. 717-722
    • Skorning, M.1    Derwall, M.2    Brokmann, J.C.3
  • 37
    • 54549102434 scopus 로고    scopus 로고
    • Improving cardiopulmonary resuscitation quality and resuscitation training by combining audiovisual feedback and debriefing
    • Dine C.J., Gersh R.E., Leary M., Riegel B.J., Bellini L.M., Abella B.S. Improving cardiopulmonary resuscitation quality and resuscitation training by combining audiovisual feedback and debriefing. Crit Care Med 2008, 36:2817-2822.
    • (2008) Crit Care Med , vol.36 , pp. 2817-2822
    • Dine, C.J.1    Gersh, R.E.2    Leary, M.3    Riegel, B.J.4    Bellini, L.M.5    Abella, B.S.6
  • 38
    • 0032031072 scopus 로고    scopus 로고
    • The study of the effectiveness of chest compressions using the CPR-plus
    • Elding C., Baskett P., Hughes A. The study of the effectiveness of chest compressions using the CPR-plus. Resuscitation 1998, 36:169-173.
    • (1998) Resuscitation , vol.36 , pp. 169-173
    • Elding, C.1    Baskett, P.2    Hughes, A.3
  • 39
    • 0037381977 scopus 로고    scopus 로고
    • Improving CPR performance using an audible feedback system suitable for incorporation into an automated external defibrillator
    • Handley A.J., Handley S.A. Improving CPR performance using an audible feedback system suitable for incorporation into an automated external defibrillator. Resuscitation 2003, 57:57-62.
    • (2003) Resuscitation , vol.57 , pp. 57-62
    • Handley, A.J.1    Handley, S.A.2
  • 40
    • 23244447043 scopus 로고    scopus 로고
    • The effect of a voice assist manikin (VAM) system on CPR quality among prehospital providers
    • Hostler D., Wang H., Parrish K., Platt T.E., Guimond G. The effect of a voice assist manikin (VAM) system on CPR quality among prehospital providers. Prehosp Emerg Care 2005, 9:53-60.
    • (2005) Prehosp Emerg Care , vol.9 , pp. 53-60
    • Hostler, D.1    Wang, H.2    Parrish, K.3    Platt, T.E.4    Guimond, G.5
  • 41
    • 0034839402 scopus 로고    scopus 로고
    • An automated voice advisory manikin system for training in basic life support without an instructor. A novel approach to CPR training
    • Wik L., Thowsen J., Andreas Steen P. An automated voice advisory manikin system for training in basic life support without an instructor. A novel approach to CPR training. Resuscitation 2001, 50:167-172.
    • (2001) Resuscitation , vol.50 , pp. 167-172
    • Wik, L.1    Thowsen, J.2    Andreas Steen, P.3
  • 42
    • 80051964741 scopus 로고    scopus 로고
    • Randomized crossover trial comparing physical strain on advanced life support providers during transportation using real-time automated feedback
    • Havel C., van Tulder R., Schreiber W., et al. Randomized crossover trial comparing physical strain on advanced life support providers during transportation using real-time automated feedback. Acad Emerg Med 2011, 18:860-867.
    • (2011) Acad Emerg Med , vol.18 , pp. 860-867
    • Havel, C.1    van Tulder, R.2    Schreiber, W.3
  • 43
    • 0028964538 scopus 로고
    • Utilization of a pressure-sensing monitor to improve in-flight chest compressions
    • Thomas S.H., Stone C.K., Austin P.E., March J.A., Brinkley S. Utilization of a pressure-sensing monitor to improve in-flight chest compressions. Am J Emerg Med 1995, 13:155-157.
    • (1995) Am J Emerg Med , vol.13 , pp. 155-157
    • Thomas, S.H.1    Stone, C.K.2    Austin, P.E.3    March, J.A.4    Brinkley, S.5
  • 44
    • 44349178712 scopus 로고    scopus 로고
    • Improving in-hospital cardiac arrest process and outcomes with performance debriefing
    • Edelson D.P., Litzinger B., Arora V., et al. Improving in-hospital cardiac arrest process and outcomes with performance debriefing. Arch Intern Med 2008, 168:1063-1069.
    • (2008) Arch Intern Med , vol.168 , pp. 1063-1069
    • Edelson, D.P.1    Litzinger, B.2    Arora, V.3
  • 45
    • 0021266585 scopus 로고
    • The physiology of external cardiac massage: high-impulse cardiopulmonary resuscitation
    • Maier G.W., Tyson G.S., Olsen C.O., et al. The physiology of external cardiac massage: high-impulse cardiopulmonary resuscitation. Circulation 1984, 70:86-101.
    • (1984) Circulation , vol.70 , pp. 86-101
    • Maier, G.W.1    Tyson, G.S.2    Olsen, C.O.3
  • 46
    • 0026599640 scopus 로고
    • A study of chest compression rates during cardiopulmonary resuscitation in humans: the importance of rate-directed chest compressions
    • Kern K.B., Sanders A.B., Raife J., Milander M.M., Otto C.W., Ewy G.A. A study of chest compression rates during cardiopulmonary resuscitation in humans: the importance of rate-directed chest compressions. Arch Intern Med 1992, 152:145-149.
    • (1992) Arch Intern Med , vol.152 , pp. 145-149
    • Kern, K.B.1    Sanders, A.B.2    Raife, J.3    Milander, M.M.4    Otto, C.W.5    Ewy, G.A.6
  • 47
    • 84862584937 scopus 로고    scopus 로고
    • Relationship between chest compression rates and outcomes from cardiac arrest
    • Idris A.H., Guffey D., Aufderheide T.P., et al. Relationship between chest compression rates and outcomes from cardiac arrest. Circulation 2012, 125:3004-3012.
    • (2012) Circulation , vol.125 , pp. 3004-3012
    • Idris, A.H.1    Guffey, D.2    Aufderheide, T.P.3
  • 48
    • 80054109572 scopus 로고    scopus 로고
    • The effect of real-time CPR feedback and post event debriefing on patient and processes focused outcomes: a cohort study: trial protocol
    • Perkins G.D., Davies R.P., Quinton S., et al. The effect of real-time CPR feedback and post event debriefing on patient and processes focused outcomes: a cohort study: trial protocol. Scand J Trauma Resusc Emerg Med 2011, 19:58.
    • (2011) Scand J Trauma Resusc Emerg Med , vol.19 , pp. 58
    • Perkins, G.D.1    Davies, R.P.2    Quinton, S.3
  • 50
    • 84875255624 scopus 로고    scopus 로고
    • Motion detection technology as a tool for cardiopulmonary resuscitation (CPR) quality training: a randomised crossover mannequin pilot study
    • Semeraro F., Frisoli A., Loconsole C., et al. Motion detection technology as a tool for cardiopulmonary resuscitation (CPR) quality training: a randomised crossover mannequin pilot study. Resuscitation 2013, 84:501-507.
    • (2013) Resuscitation , vol.84 , pp. 501-507
    • Semeraro, F.1    Frisoli, A.2    Loconsole, C.3
  • 51
    • 84870427629 scopus 로고    scopus 로고
    • The specific effect of metronome guidance on the quality of one-person cardiopulmonary resuscitation and rescuer fatigue
    • Chung T.N., Kim S.W., You J.S., et al. The specific effect of metronome guidance on the quality of one-person cardiopulmonary resuscitation and rescuer fatigue. J Emerg Med 2012, 43:1049-1054.
    • (2012) J Emerg Med , vol.43 , pp. 1049-1054
    • Chung, T.N.1    Kim, S.W.2    You, J.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.