Volumn 5, Issue 3, 2014, Pages 675-689

Diffuse reflectance spectroscopy of epithelial tissue with a smart fiber-optic probe

Author keywords

[No Author keywords available]

Indexed keywords

FIBER OPTICS; HISTOLOGY; OPTICAL SYSTEMS; PERSONNEL TRAINING; PROBES; SPECTROSCOPY;

EID: 84895743481     PISSN: None     EISSN: 21567085     Source Type: Journal    
DOI: 10.1364/BOE.5.000675     Document Type: Article
Times cited : (65)

References (60)
  • 2
    • 20444420193 scopus 로고    scopus 로고
    • Effect of screening on oral cancer mortality in Kerala, India: A clusterrandomised controlled trial
    • Trivandrum Oral Cancer Screening Study Group
    • R. Sankaranarayanan, K. Ramadas, G. Thomas, R. Muwonge, S. Thara, B. Mathew, and B. Rajan; Trivandrum Oral Cancer Screening Study Group, "Effect of screening on oral cancer mortality in Kerala, India: a clusterrandomised controlled trial, " Lancet 365(9475), 1927-1933 (2005).
    • (2005) Lancet , vol.365 , Issue.9475 , pp. 1927-1933
    • Sankaranarayanan, R.1    Ramadas, K.2    Thomas, G.3    Muwonge, R.4    Thara, S.5    Mathew, B.6    Rajan, B.7
  • 5
    • 33846265284 scopus 로고    scopus 로고
    • Impact of the National Breast and Cervical Cancer Early Detection Program on mammography and Pap test utilization among white, Hispanic, and African American women: 1996-2000
    • E. K. Adams, N. Breen, and P. J. Joski, "Impact of the National Breast and Cervical Cancer Early Detection Program on mammography and Pap test utilization among white, Hispanic, and African American women: 1996-2000, " Cancer 109(S2), 348-358 (2007).
    • (2007) Cancer , vol.109 , Issue.S2 , pp. 348-358
    • Adams, E.K.1    Breen, N.2    Joski, P.J.3
  • 7
    • 16544392809 scopus 로고    scopus 로고
    • Implementing recommendations for the early detection of breast and cervical cancer among low-income women
    • H. W. Lawson, R. Henson, J. K. Bobo, and M. K. Kaeser, "Implementing recommendations for the early detection of breast and cervical cancer among low-income women, " MMWR Recomm. Rep. 49(RR-2), 37-55 (2000).
    • (2000) MMWR Recomm. Rep. , vol.49 , Issue.RR-2 , pp. 37-55
    • Lawson, H.W.1    Henson, R.2    Bobo, J.K.3    Kaeser, M.K.4
  • 8
    • 0034786826 scopus 로고    scopus 로고
    • Cervical cancer in the developing world
    • J. Sherris, C. Herdman, and C. Elias, "Cervical cancer in the developing world, " West. J. Med. 175(4), 231-233 (2001).
    • (2001) West. J. Med. , vol.175 , Issue.4 , pp. 231-233
    • Sherris, J.1    Herdman, C.2    Elias, C.3
  • 9
    • 34250205253 scopus 로고    scopus 로고
    • Comparison of a physical model and principal component analysis for the diagnosis of epithelial neoplasias in vivo using diffuse reflectance spectroscopy
    • M. C. Skala, G. M. Palmer, K. M. Vrotsos, A. Gendron-Fitzpatrick, and N. Ramanujam, "Comparison of a physical model and principal component analysis for the diagnosis of epithelial neoplasias in vivo using diffuse reflectance spectroscopy, " Opt. Express 15(12), 7863-7875 (2007).
    • (2007) Opt. Express , vol.15 , Issue.12 , pp. 7863-7875
    • Skala, M.C.1    Palmer, G.M.2    Vrotsos, K.M.3    Gendron-Fitzpatrick, A.4    Ramanujam, N.5
  • 10
    • 65549088023 scopus 로고    scopus 로고
    • Quantitative physiology of the precancerous cervix in vivo through optical spectroscopy
    • V. T. Chang, P. S. Cartwright, S. M. Bean, G. M. Palmer, R. C. Bentley, and N. Ramanujam, "Quantitative physiology of the precancerous cervix in vivo through optical spectroscopy, " Neoplasia 11(4), 325-332 (2009).
    • (2009) Neoplasia , vol.11 , Issue.4 , pp. 325-332
    • Chang, V.T.1    Cartwright, P.S.2    Bean, S.M.3    Palmer, G.M.4    Bentley, R.C.5    Ramanujam, N.6
  • 14
    • 33744496072 scopus 로고    scopus 로고
    • Oral cancer detection using diffuse reflectance spectral ratio R540/R575 of oxygenated hemoglobin bands
    • N. Subhash, J. R. Mallia, S. S. Thomas, A. Mathews, P. Sebastian, and J. Madhavan, "Oral cancer detection using diffuse reflectance spectral ratio R540/R575 of oxygenated hemoglobin bands, " J. Biomed. Opt. 11(1), 014018 (2006).
    • (2006) J. Biomed. Opt. , vol.11 , Issue.1 , pp. 014018
    • Subhash, N.1    Mallia, J.R.2    Thomas, S.S.3    Mathews, A.4    Sebastian, P.5    Madhavan, J.6
  • 15
    • 37049024947 scopus 로고    scopus 로고
    • Noninvasive measurement of the morphology and physiology of oral mucosa by use of optical spectroscopy
    • A. Amelink, O. P. Kaspers, H. J. Sterenborg, J. E. van der Wal, J. L. Roodenburg, and M. J. Witjes, "Noninvasive measurement of the morphology and physiology of oral mucosa by use of optical spectroscopy, " Oral Oncol. 44(1), 65-71 (2008).
    • (2008) Oral Oncol. , vol.44 , Issue.1 , pp. 65-71
    • Amelink, A.1    Kaspers, O.P.2    Sterenborg, H.J.3    van der Wal, J.E.4    Roodenburg, J.L.5    Witjes, M.J.6
  • 16
    • 51649096672 scopus 로고    scopus 로고
    • Low-cost, multimodal, portable screening system for early detection of oral cancer
    • M. Rahman, P. Chaturvedi, A. M. Gillenwater, and R. Richards-Kortum, "Low-cost, multimodal, portable screening system for early detection of oral cancer, " J. Biomed. Opt. 13(3), 030502 (2008).
    • (2008) J. Biomed. Opt. , vol.13 , Issue.3 , pp. 030502
    • Rahman, M.1    Chaturvedi, P.2    Gillenwater, A.M.3    Richards-Kortum, R.4
  • 17
    • 43049116511 scopus 로고    scopus 로고
    • Autofluorescence and diffuse reflectance spectroscopy of oral epithelial tissue using a depth-sensitive fiberoptic probe
    • R. A. Schwarz, W. Gao, D. Daye, M. D. Williams, R. Richards-Kortum, and A. M. Gillenwater, "Autofluorescence and diffuse reflectance spectroscopy of oral epithelial tissue using a depth-sensitive fiberoptic probe, " Appl. Opt. 47(6), 825-834 (2008).
    • (2008) Appl. Opt. , vol.47 , Issue.6 , pp. 825-834
    • Schwarz, R.A.1    Gao, W.2    Daye, D.3    Williams, M.D.4    Richards-Kortum, R.5    Gillenwater, A.M.6
  • 22
    • 33847257298 scopus 로고    scopus 로고
    • Spatially resolved reflectance spectroscopy for diagnosis of cervical precancer: Monte Carlo modeling and comparison to clinical measurements
    • D. Arifler, C. MacAulay, M. Follen, and R. Richards-Kortum, "Spatially resolved reflectance spectroscopy for diagnosis of cervical precancer: Monte Carlo modeling and comparison to clinical measurements, " J. Biomed. Opt. 11(6), 064027 (2006).
    • (2006) J. Biomed. Opt. , vol.11 , Issue.6 , pp. 064027
    • Arifler, D.1    McAulay, C.2    Follen, M.3    Richards-Kortum, R.4
  • 24
    • 34748925205 scopus 로고    scopus 로고
    • The performance of fluorescence and reflectance spectroscopy for the in vivo diagnosis of cervical neoplasia; point probe versus multispectral approaches
    • J. A. Freeberg, J. L. Benedet, C. MacAulay, L. A. West, and M. Follen, "The performance of fluorescence and reflectance spectroscopy for the in vivo diagnosis of cervical neoplasia; point probe versus multispectral approaches, " Gynecol. Oncol. 107(1 Suppl 1), S248-S255 (2007).
    • (2007) Gynecol. Oncol. , vol.107 , Issue.1 SUPPL. 1
    • Freeberg, J.A.1    Benedet, J.L.2    McAulay, C.3    West, L.A.4    Follen, M.5
  • 25
    • 35948931808 scopus 로고    scopus 로고
    • Targeting spectral signatures of progressively dysplastic stratified epithelia using angularly variable fiber geometry in reflectance Monte Carlo simulations
    • A. Wang, V. Nammalavar, and R. Drezek, "Targeting spectral signatures of progressively dysplastic stratified epithelia using angularly variable fiber geometry in reflectance Monte Carlo simulations, " J. Biomed. Opt. 12(4), 044012 (2007).
    • (2007) J. Biomed. Opt. , vol.12 , Issue.4 , pp. 044012
    • Wang, A.1    Nammalavar, V.2    Drezek, R.3
  • 26
    • 22944476457 scopus 로고    scopus 로고
    • Reflectance spectroscopy for diagnosis of epithelial precancer: Model-based analysis of fiber-optic probe designs to resolve spectral information from epithelium and stroma
    • D. Arifler, R. A. Schwarz, S. K. Chang, and R. Richards-Kortum, "Reflectance spectroscopy for diagnosis of epithelial precancer: model-based analysis of fiber-optic probe designs to resolve spectral information from epithelium and stroma, " Appl. Opt. 44(20), 4291-4305 (2005).
    • (2005) Appl. Opt. , vol.44 , Issue.20 , pp. 4291-4305
    • Arifler, D.1    Schwarz, R.A.2    Chang, S.K.3    Richards-Kortum, R.4
  • 28
  • 29
    • 0035515902 scopus 로고    scopus 로고
    • Angiogenesis in oral cancer
    • R. Hasina and M. W. Lingen, "Angiogenesis in oral cancer, " J. Dent. Educ. 65(11), 1282-1290 (2001).
    • (2001) J. Dent. Educ. , vol.65 , Issue.11 , pp. 1282-1290
    • Hasina, R.1    Lingen, M.W.2
  • 31
    • 33746154212 scopus 로고    scopus 로고
    • Sequential estimation of optical properties of a two-layered epithelial tissue model from depth-resolved ultraviolet-visible diffuse reflectance spectra
    • Q. Liu and N. Ramanujam, "Sequential estimation of optical properties of a two-layered epithelial tissue model from depth-resolved ultraviolet-visible diffuse reflectance spectra, " Appl. Opt. 45(19), 4776-4790 (2006).
    • (2006) Appl. Opt. , vol.45 , Issue.19 , pp. 4776-4790
    • Liu, Q.1    Ramanujam, N.2
  • 32
    • 24744465656 scopus 로고    scopus 로고
    • Use of a multiseparation fiber optic probe for the optical diagnosis of breast cancer
    • C. Zhu, G. M. Palmer, T. M. Breslin, F. Xu, and N. Ramanujam, "Use of a multiseparation fiber optic probe for the optical diagnosis of breast cancer, " J. Biomed. Opt. 10(2), 024032 (2005).
    • (2005) J. Biomed. Opt. , vol.10 , Issue.2 , pp. 024032
    • Zhu, C.1    Palmer, G.M.2    Breslin, T.M.3    Xu, F.4    Ramanujam, N.5
  • 33
    • 33645157161 scopus 로고    scopus 로고
    • Monte Carlo-based inverse model for calculating tissue optical properties. Part I: Theory and validation on synthetic phantoms
    • G. M. Palmer and N. Ramanujam, "Monte Carlo-based inverse model for calculating tissue optical properties. Part I: Theory and validation on synthetic phantoms, " Appl. Opt. 45(5), 1062-1071 (2006).
    • (2006) Appl. Opt. , vol.45 , Issue.5 , pp. 1062-1071
    • Palmer, G.M.1    Ramanujam, N.2
  • 34
    • 0037208325 scopus 로고    scopus 로고
    • Fiber optic probes for biomedical optical spectroscopy
    • U. Utzinger and R. R. Richards-Kortum, "Fiber optic probes for biomedical optical spectroscopy, " J. Biomed. Opt. 8(1), 121-147 (2003).
    • (2003) J. Biomed. Opt. , vol.8 , Issue.1 , pp. 121-147
    • Utzinger, U.1    Richards-Kortum, R.R.2
  • 36
    • 44849126697 scopus 로고    scopus 로고
    • Analysis of changes in reflectance measurements on biological tissues subjected to different probe pressures
    • R. Reif, M. S. Amorosino, K. W. Calabro, O. A'Amar, S. K. Singh, and I. J. Bigio, "Analysis of changes in reflectance measurements on biological tissues subjected to different probe pressures, " J. Biomed. Opt. 13(1), 010502 (2008).
    • (2008) J. Biomed. Opt. , vol.13 , Issue.1 , pp. 010502
    • Reif, R.1    Amorosino, M.S.2    Calabro, K.W.3    A'Amar, O.4    Singh, S.K.5    Bigio, I.J.6
  • 37
    • 41149132389 scopus 로고    scopus 로고
    • Effects of probe contact pressure on in vivo optical spectroscopy
    • Y. Ti and W. C. Lin, "Effects of probe contact pressure on in vivo optical spectroscopy, " Opt. Express 16(6), 4250-4262 (2008).
    • (2008) Opt. Express , vol.16 , Issue.6 , pp. 4250-4262
    • Ti, Y.1    Lin, W.C.2
  • 39
    • 8544262183 scopus 로고    scopus 로고
    • The effects of repeated spectroscopic pressure measurements on fluorescence intensity in the cervix
    • K. Rivoire, A. Nath, D. Cox, E. N. Atkinson, R. Richards-Kortum, and M. Follen, "The effects of repeated spectroscopic pressure measurements on fluorescence intensity in the cervix, " Am. J. Obstet. Gynecol. 191(5), 1606-1617 (2004).
    • (2004) Am. J. Obstet. Gynecol. , vol.191 , Issue.5 , pp. 1606-1617
    • Rivoire, K.1    Nath, A.2    Cox, D.3    Atkinson, E.N.4    Richards-Kortum, R.5    Follen, M.6
  • 40
    • 0032225333 scopus 로고    scopus 로고
    • Pressure effects on soft tissues monitored by changes in tissue
    • H. Shangguan, S. A. Prahl, S. L. Jacques, and L. W. Casperson, "Pressure effects on soft tissues monitored by changes in tissue, " Proc. SPIE 3254, 366 (1998).
    • (1998) Proc. SPIE , vol.3254 , pp. 366
    • Shangguan, H.1    Prahl, S.A.2    Jacques, S.L.3    Casperson, L.W.4
  • 42
    • 23044440539 scopus 로고    scopus 로고
    • Influence of contact state on NIR diffuse reflectance spectroscopy in vivo
    • W. Chen, R. Liu, K. Xu, and R. K. Wang, "Influence of contact state on NIR diffuse reflectance spectroscopy in vivo, " J. Phys. D Appl. Phys. 38(15), 2691-2695 (2005).
    • (2005) J. Phys. D Appl. Phys. , vol.38 , Issue.15 , pp. 2691-2695
    • Chen, W.1    Liu, R.2    Xu, K.3    Wang, R.K.4
  • 43
    • 80052758698 scopus 로고    scopus 로고
    • Analysis of pressure, angle and temporal effects on tissue optical properties from polarization-gated spectroscopic probe measurements
    • S. Ruderman, A. J. Gomes, V. Stoyneva, J. D. Rogers, A. J. Fought, B. D. Jovanovic, and V. Backman, "Analysis of pressure, angle and temporal effects on tissue optical properties from polarization-gated spectroscopic probe measurements, " Biomed. Opt. Express 1(2), 489-499 (2010).
    • (2010) Biomed. Opt. Express , vol.1 , Issue.2 , pp. 489-499
    • Ruderman, S.1    Gomes, A.J.2    Stoyneva, V.3    Rogers, J.D.4    Fought, A.J.5    Jovanovic, B.D.6    Backman, V.7
  • 44
    • 0030150929 scopus 로고    scopus 로고
    • Spatially resolved absolute diffuse reflectance measurements for noninvasive determination of the optical scattering and absorption coefficients of biological tissue
    • A. Kienle, L. Lilge, M. S. Patterson, R. Hibst, R. Steiner, and B. C. Wilson, "Spatially resolved absolute diffuse reflectance measurements for noninvasive determination of the optical scattering and absorption coefficients of biological tissue, " Appl. Opt. 35(13), 2304-2314 (1996).
    • (1996) Appl. Opt. , vol.35 , Issue.13 , pp. 2304-2314
    • Kienle, A.1    Lilge, L.2    Patterson, M.S.3    Hibst, R.4    Steiner, R.5    Wilson, B.C.6
  • 45
    • 34247492197 scopus 로고    scopus 로고
    • Liquid-crystal tunable filter spectral imaging for brain tumor demarcation
    • S. C. Gebhart, R. C. Thompson, and A. Mahadevan-Jansen, "Liquid-crystal tunable filter spectral imaging for brain tumor demarcation, " Appl. Opt. 46(10), 1896-1910 (2007).
    • (2007) Appl. Opt. , vol.46 , Issue.10 , pp. 1896-1910
    • Gebhart, S.C.1    Thompson, R.C.2    Mahadevan-Jansen, A.3
  • 46
    • 84860565947 scopus 로고    scopus 로고
    • Development of a noncontact diffuse optical spectroscopy probe for measuring tissue optical properties
    • S. F. Bish, N. Rajaram, B. Nichols, and J. W. Tunnell, "Development of a noncontact diffuse optical spectroscopy probe for measuring tissue optical properties, " J. Biomed. Opt. 16(12), 120505 (2011).
    • (2011) J. Biomed. Opt. , vol.16 , Issue.12 , pp. 120505
    • Bish, S.F.1    Rajaram, N.2    Nichols, B.3    Tunnell, J.W.4
  • 47
    • 67650314450 scopus 로고    scopus 로고
    • Quantitation and mapping of tissue optical properties using modulated imaging
    • D. J. Cuccia, F. Bevilacqua, A. J. Durkin, F. R. Ayers, and B. J. Tromberg, "Quantitation and mapping of tissue optical properties using modulated imaging, " J. Biomed. Opt. 14(2), 024012 (2009).
    • (2009) J. Biomed. Opt. , vol.14 , Issue.2 , pp. 024012
    • Cuccia, D.J.1    Bevilacqua, F.2    Durkin, A.J.3    Ayers, F.R.4    Tromberg, B.J.5
  • 48
    • 0030855571 scopus 로고    scopus 로고
    • Design and testing of a white-light, steady-state diffuse reflectance spectrometer for determination of optical properties of highly scattering systems
    • M. G. Nichols, E. L. Hull, and T. H. Foster, "Design and testing of a white-light, steady-state diffuse reflectance spectrometer for determination of optical properties of highly scattering systems, " Appl. Opt. 36(1), 93-104 (1997).
    • (1997) Appl. Opt. , vol.36 , Issue.1 , pp. 93-104
    • Nichols, M.G.1    Hull, E.L.2    Foster, T.H.3
  • 53
    • 50549090128 scopus 로고    scopus 로고
    • Diffuse reflectance spectroscopy with a selfcalibrating fiber optic probe
    • B. Yu, H. Fu, T. Bydlon, J. E. Bender, and N. Ramanujam, "Diffuse reflectance spectroscopy with a selfcalibrating fiber optic probe, " Opt. Lett. 33(16), 1783-1785 (2008).
    • (2008) Opt. Lett. , vol.33 , Issue.16 , pp. 1783-1785
    • Yu, B.1    Fu, H.2    Bydlon, T.3    Bender, J.E.4    Ramanujam, N.5
  • 54
    • 79955386810 scopus 로고    scopus 로고
    • Instrument independent diffuse reflectance spectroscopy
    • B. Yu, H. L. Fu, and N. Ramanujam, "Instrument independent diffuse reflectance spectroscopy, " J. Biomed. Opt. 16(1), 011010 (2011).
    • (2011) J. Biomed. Opt. , vol.16 , Issue.1 , pp. 011010
    • Yu, B.1    Fu, H.L.2    Ramanujam, N.3
  • 55
    • 80052735431 scopus 로고    scopus 로고
    • Towards a field-compatible optical spectroscopic device for cervical cancer screening in resource-limited settings: Effects of calibration and pressure
    • V. T.-C. Chang, D. Merisier, B. Yu, D. K. Walmer, and N. Ramanujam, "Towards a field-compatible optical spectroscopic device for cervical cancer screening in resource-limited settings: effects of calibration and pressure, " Opt. Express 19(19), 17908-17924 (2011).
    • (2011) Opt. Express , vol.19 , Issue.19 , pp. 17908-17924
    • Chang, V.T.-C.1    Merisier, D.2    Yu, B.3    Walmer, D.K.4    Ramanujam, N.5
  • 56
    • 0042973927 scopus 로고    scopus 로고
    • Fiber Fabry-Perot sensors for detection of partial discharges in power transformers
    • B. Yu, D. W. Kim, J. Deng, H. Xiao, and A. Wang, "Fiber Fabry-Perot sensors for detection of partial discharges in power transformers, " Appl. Opt. 42(16), 3241-3250 (2003).
    • (2003) Appl. Opt. , vol.42 , Issue.16 , pp. 3241-3250
    • Yu, B.1    Kim, D.W.2    Deng, J.3    Xiao, H.4    Wang, A.5
  • 57
    • 20944432191 scopus 로고    scopus 로고
    • Tunable-optical-filter-based white-light interferometry for sensing
    • B. Yu, A. Wang, G. Pickrell, and J. Xu, "Tunable-optical-filter-based white-light interferometry for sensing, " Opt. Lett. 30(12), 1452-1454 (2005).
    • (2005) Opt. Lett. , vol.30 , Issue.12 , pp. 1452-1454
    • Yu, B.1    Wang, A.2    Pickrell, G.3    Xu, J.4
  • 58
    • 16644380162 scopus 로고    scopus 로고
    • Epoxy-free high temperature fiber optic pressure sensors for gas turbine engine applications
    • J. Xu, G. R. Pickrell, B. Yu, M. Han, Y. Zhu, X. Wang, K. L. Cooper, and A. Wang, "Epoxy-free high temperature fiber optic pressure sensors for gas turbine engine applications, " Proc. SPIE 5590, 1 (2004).
    • (2004) Proc. SPIE 5590 , vol.1
    • Xu, J.1    Pickrell, G.R.2    Yu, B.3    Han, M.4    Zhu, Y.5    Wang, X.6    Cooper, K.L.7    Wang, A.8
  • 59
    • 0042973927 scopus 로고    scopus 로고
    • Fiber Fabry-Perot Sensors for Detection of Partial Discharges in Power Transformers
    • B. Yu, D. W. Kim, J. Deng, H. Xiao, and A. Wang, "Fiber Fabry-Perot Sensors for Detection of Partial Discharges in Power Transformers, " Appl. Opt. 42(16), 3241-3250 (2003).
    • (2003) Appl. Opt. , vol.42 , Issue.16 , pp. 3241-3250
    • Yu, B.1    Kim, D.W.2    Deng, J.3    Xiao, H.4    Wang, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.