메뉴 건너뛰기




Volumn 55, Issue 1, 2014, Pages 169-174

Improved nuclear medicine uniformity assessment with noise texture analysis

Author keywords

Noise power spectrum; Quality assurance; Quantitative analysis; Uniformity; camera

Indexed keywords

ARTICLE; ARTIFACT REDUCTION; CENTRAL FIELD OF VIEW; CONTROLLED STUDY; GAMMA CAMERA; IMAGE ANALYSIS; IMAGE PROCESSING; IMAGE QUALITY; MEASUREMENT ACCURACY; NOISE POWER SPECTRUM; NOISE TEXTURE ANALYSIS; NUCLEAR MEDICINE UNIFORMITY ASSESSMENT; PREDICTIVE VALUE; PRIORITY JOURNAL; RADIOLOGICAL PARAMETERS; RADIOLOGICAL PROCEDURES; SENSITIVITY ANALYSIS; SOUND ANALYSIS; SOUND RELATED PHENOMENA; STRUCTURED NOISE INDEX; USEFUL FIELD OF VIEW; VISION; Γ CAMERA; ALGORITHM; ARTIFACT; HUMAN; METHODOLOGY; NUCLEAR MEDICINE; OBSERVER VARIATION; QUALITY CONTROL; QUANTITATIVE ANALYSIS; RECEIVER OPERATING CHARACTERISTIC; REPRODUCIBILITY; STANDARD; UNIFORMITY;

EID: 84894711184     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: 10.2967/jnumed.113.125450     Document Type: Article
Times cited : (6)

References (29)
  • 1
    • 0030253119 scopus 로고    scopus 로고
    • Instrument-And computer-related problems and artifacts in nuclear medicine
    • O'Connor MK. Instrument-And computer-related problems and artifacts in nuclear medicine. Semin Nucl Med. 1996;26: 256-277.
    • (1996) Semin Nucl Med. , vol.26 , pp. 256-277
    • O'Connor, M.K.1
  • 2
    • 79960303672 scopus 로고
    • The non-uniformity of imaging devices and their impact in quantitative studies
    • Vienna, Austria: International Atomic Energy Agency
    • Todd-Pokropek AE, Erbsmann F, Soussaline F. The non-uniformity of imaging devices and their impact in quantitative studies. Medical Radionuclide Imaging. Vol. 1. Vienna, Austria: International Atomic Energy Agency; 1977: 67-84.
    • (1977) Medical Radionuclide Imaging. , vol.1 , pp. 67-84
    • Todd-Pokropek, A.E.1    Erbsmann, F.2    Soussaline, F.3
  • 3
    • 84901408686 scopus 로고
    • Quality assurance of anger cameras
    • In: Rao D Chandra R Graham M Eds. Medical Physics Monograph No 10 New York, NY: American Association of Physicists in Medicine
    • Graham LS. Quality assurance of Anger cameras. In: Rao D, Chandra R, Graham M, eds. Physics of Nuclear Medicine: Recent Advances. Medical Physics Monograph No. 10. New York, NY: American Association of Physicists in Medicine; 1984: 68-82.
    • (1984) Physics Of Nuclear Medicine: Recent Advances , pp. 68-82
    • Graham, L.S.1
  • 4
    • 0016989498 scopus 로고
    • A numerical index of gamma-camera uniformity [letter]
    • Cox NJ, Diffey BL. A numerical index of gamma-camera uniformity [letter]. Br J Radiol. 1976;49: 734-735.
    • (1976) Br J Radiol. , vol.49 , pp. 734-735
    • Cox, N.J.1    Diffey, B.L.2
  • 5
    • 0023853826 scopus 로고
    • Factors affecting gamma-camera non-uniformity
    • Hughes A, Sharp PF. Factors affecting gamma-camera non-uniformity. Phys Med Biol. 1988;33: 259-269.
    • (1988) Phys Med Biol. , vol.33 , pp. 259-269
    • Hughes, A.1    Sharp, P.F.2
  • 6
    • 84901454237 scopus 로고
    • International Electrotechnical Commission. Geneva Switzerland: International Electrotechnical Commission
    • International Electrotechnical Commission. Characteristics and Test Conditions for Anger-Type Gamma Cameras. Geneva, Switzerland: International Electrotechnical Commission; 1984.
    • (1984) Characteristics And Test Conditions For Anger-Type Gamma Cameras
  • 7
    • 0015364389 scopus 로고
    • Image analysis by on-line minicomputer for improved camera quality control
    • Keyes JW Jr, Gazella GR, Strange DR. Image analysis by on-line minicomputer for improved camera quality control. J Nucl Med. 1972;13: 525-527.
    • (1972) J Nucl Med. , vol.13 , pp. 525-527
    • Keyes Jr., J.W.1    Gazella, G.R.2    Strange, D.R.3
  • 8
    • 73249120946 scopus 로고    scopus 로고
    • National Electrical Manufacturers Association. Rosslyn VA: National Electrical Manufacturers Association
    • National Electrical Manufacturers Association. Performance Measurements of Gamma Cameras. Rosslyn, VA: National Electrical Manufacturers Association; 2007.
    • (2007) Performance Measurements Of Gamma Cameras
  • 9
    • 84901430020 scopus 로고
    • Performance standards: Characteristics and test conditions for scintillation cameras
    • Vienna, Austria: International Atomic Energy Agency
    • Sano RM. Performance standards: characteristics and test conditions for scintillation cameras. Medical Radionuclide Imaging. Vol. 2. Vienna, Austria: International Atomic Energy Agency; 1980: 293-295.
    • (1980) Medical Radionuclide Imaging. , vol.2 , pp. 293-295
    • Sano, R.M.1
  • 10
    • 0019482420 scopus 로고
    • The usefulness of indices measuring gamma camera nonuniformity
    • Sharp P, Marshall I. The usefulness of indices measuring gamma camera nonuniformity. Phys Med Biol. 1981;26: 149-153.
    • (1981) Phys Med Biol. , vol.26 , pp. 149-153
    • Sharp, P.1    Marshall, I.2
  • 12
    • 0026507677 scopus 로고
    • An evaluation of cusum analysis and control charts applied to quantitative gamma-camera uniformity parameters for automated quality control
    • Knight AC, Williams ED. An evaluation of cusum analysis and control charts applied to quantitative gamma-camera uniformity parameters for automated quality control. Eur J Nucl Med. 1992;19: 125-130.
    • (1992) Eur J Nucl Med. , vol.19 , pp. 125-130
    • Knight, A.C.1    Williams, E.D.2
  • 14
    • 10144241152 scopus 로고
    • Nuclear Medicine Committee American Association Of Physicists In Medicine. New York NY: American Institute Of Physics
    • Nuclear Medicine Committee, American Association of Physicists in Medicine. Computer-Aided Scintillation Camera Acceptance Testing. New York, NY: American Institute of Physics; 1982.
    • (1982) Computer-Aided Scintillation Camera Acceptance Testing
  • 15
    • 0032812524 scopus 로고    scopus 로고
    • Experimental comparison of noise and resolution for 2k and 4k storage phosphor radiography systems
    • Flynn MJ, Samei E. Experimental comparison of noise and resolution for 2k and 4k storage phosphor radiography systems. Med Phys. 1999;26: 1612-1623.
    • (1999) Med Phys. , vol.26 , pp. 1612-1623
    • Flynn, M.J.1    Samei, E.2
  • 16
    • 84867302075 scopus 로고    scopus 로고
    • Quantitative comparison of noise texture across ct scanners from different manufacturers
    • Solomon JB, Christianson O, Samei E. Quantitative comparison of noise texture across CT scanners from different manufacturers. Med Phys. 2012;39: 6048-6055.
    • (2012) Med Phys. , vol.39 , pp. 6048-6055
    • Solomon, J.B.1    Christianson, O.2    Samei, E.3
  • 17
    • 84874781616 scopus 로고    scopus 로고
    • A methodology for image quality evaluation of advanced ct systems
    • Wilson JM, Christianson OI, Richard S, Samei E. A methodology for image quality evaluation of advanced CT systems. Med Phys. 2013;40: 031908.
    • (2013) Med Phys. , vol.40 , pp. 031908
    • Wilson, J.M.1    Christianson, O.I.2    Richard, S.3    Samei, E.4
  • 18
    • 0022531738 scopus 로고
    • Noise analysis of scintillation camera images: Stochastic and non-stochastic effects
    • Grossman LW, Anderson MP, Jennings RJ, et al. Noise analysis of scintillation camera images: stochastic and non-stochastic effects. Phys Med Biol. 1986;31: 941-953.
    • (1986) Phys Med Biol. , vol.31 , pp. 941-953
    • Grossman, L.W.1    Anderson, M.P.2    Jennings, R.J.3
  • 19
    • 0019389608 scopus 로고
    • Analysis of recorded image noise in nuclear medicine
    • Tsui BM, Beck RN, Doi K, Metz CE. Analysis of recorded image noise in nuclear medicine. Phys Med Biol. 1981;26: 883-902.
    • (1981) Phys Med Biol. , vol.26 , pp. 883-902
    • Tsui, B.M.1    Beck, R.N.2    Doi, K.3    Metz, C.E.4
  • 20
    • 33646455469 scopus 로고    scopus 로고
    • Intercomparison of methods for image quality characterization. Ii. Noise power spectrum
    • Dobbins JT III, Samei E, Ranger NT, Chen Y. Intercomparison of methods for image quality characterization. II. Noise power spectrum. Med Phys. 2006;33: 1466-1475.
    • (2006) Med Phys. , vol.33 , pp. 1466-1475
    • Dobbins III, J.T.1    Samei, E.2    Ranger, N.T.3    Chen, Y.4
  • 21
    • 0032748266 scopus 로고    scopus 로고
    • Detection of subtle lung nodules: Relative influence of quantum and anatomic noise on chest radiographs
    • Samei E, Flynn MJ, Eyler WR. Detection of subtle lung nodules: relative influence of quantum and anatomic noise on chest radiographs. Radiology. 1999;213: 727-734.
    • (1999) Radiology. , vol.213 , pp. 727-734
    • Samei, E.1    Flynn, M.J.2    Eyler, W.R.3
  • 23
  • 24
    • 46749102563 scopus 로고    scopus 로고
    • Routine quality control of clinical nuclear medicine instrumentation: A brief review
    • Zanzonico P. Routine quality control of clinical nuclear medicine instrumentation: a brief review. J Nucl Med. 2008;49: 1114-1131.
    • (2008) J Nucl Med. , vol.49 , pp. 1114-1131
    • Zanzonico, P.1
  • 25
  • 26
    • 56049091670 scopus 로고    scopus 로고
    • Roc analysis in medical imaging: A tutorial review of the literature
    • Metz CE. ROC analysis in medical imaging: a tutorial review of the literature. Radiol Phys Technol. 2008;1: 2-12.
    • (2008) Radiol Phys Technol. , vol.1 , pp. 2-12
    • Metz, C.E.1
  • 27
    • 0023890867 scopus 로고
    • Measuring the accuracy of diagnostic systems
    • Swets JA. Measuring the accuracy of diagnostic systems. Science. 1988;240: 1285-1293.
    • (1988) Science. , vol.240 , pp. 1285-1293
    • Swets, J.A.1
  • 29
    • 0000658326 scopus 로고    scopus 로고
    • Image quality metrics for digital systems
    • Van Metter RL, Beutel J, Kundel H, eds. Bellingham, WA: Society of Photo-Optical Instrumentation Engineers
    • Dobbins JT III. Image quality metrics for digital systems. In: Van Metter RL, Beutel J, Kundel H, eds. Handbook of Medical Imaging. Vol. 1. Bellingham, WA: Society of Photo-Optical Instrumentation Engineers; 2000: 161-222.
    • (2000) Handbook of Medical Imaging. , vol.1 , pp. 161-222
    • Dobbins III, J.T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.