A methodology for image quality evaluation of advanced CT systems

Author keywords

CT; image analysis; iterative reconstruction; phantoms; tube current modulation

Indexed keywords

ANTHROPOMETRY; IMAGE ANALYSIS; IMAGE QUALITY; IMAGE RECONSTRUCTION; ITERATIVE METHODS; MODULATION; PHANTOMS; QUALITY CONTROL; SPECIFICATIONS; TEXTURES; TUBES (COMPONENTS);

EID: 84874781616     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4791645     Document Type: Article
Times cited : (99)

References (29)
  • 1
    • 4644258645 scopus 로고    scopus 로고
    • The phantom portion of the American College of Radiology (ACR) computed tomography (CT) accreditation program: Practical tips, artifact examples, and pitfalls to avoid
    • 10.1118/1.1769632
    • C. H. McCollough, " The phantom portion of the American College of Radiology (ACR) computed tomography (CT) accreditation program: Practical tips, artifact examples, and pitfalls to avoid.," Med. Phys. 31, 2423-2442 (2004). 10.1118/1.1769632
    • (2004) Med. Phys. , vol.31 , pp. 2423-2442
    • McCollough, C.H.1
  • 2
    • 0032075814 scopus 로고    scopus 로고
    • Development of phantoms for spiral CT
    • 10.1016/S0895-6111(98)00020-2
    • D. J. Goodenough, " Development of phantoms for spiral CT.," Comput. Med. Imaging Graph. 22, 247-255 (1998). 10.1016/S0895-6111(98)00020-2
    • (1998) Comput. Med. Imaging Graph. , vol.22 , pp. 247-255
    • Goodenough, D.J.1
  • 3
    • 0019485556 scopus 로고
    • A method for describing the doses delivered by transmission-x-ray computed-tomography
    • 10.1118/1.594995
    • T. B. Shope, " A method for describing the doses delivered by transmission-x-ray computed-tomography.," Med. Phys. 8, 488-495 (1981). 10.1118/1.594995
    • (1981) Med. Phys. , vol.8 , pp. 488-495
    • Shope, T.B.1
  • 4
    • 0032744531 scopus 로고    scopus 로고
    • Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies
    • 10.1118/1.598779
    • M. Gies, " Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies.," Med. Phys. 26, 2235-2247 (1999). 10.1118/1.598779
    • (1999) Med. Phys. , vol.26 , pp. 2235-2247
    • Gies, M.1
  • 5
    • 0032742081 scopus 로고    scopus 로고
    • Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements
    • 10.1118/1.598738
    • W. A. Kalender, " Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements.," Med. Phys. 26, 2248-2253 (1999). 10.1118/1.598738
    • (1999) Med. Phys. , vol.26 , pp. 2248-2253
    • Kalender, W.A.1
  • 6
    • 33645562681 scopus 로고    scopus 로고
    • CT dose reduction and dose management tools: Overview of available options
    • U. 10.1148/rg.262055138
    • C. H. McCollough, " CT dose reduction and dose management tools: Overview of available options.," Radiographics 26, U 503-U514 (2006). 10.1148/rg.262055138
    • (2006) Radiographics , vol.26
    • McCollough, C.H.1
  • 7
    • 32744470972 scopus 로고    scopus 로고
    • Report No. 05016, Medicines and Healthcare Products Regulatory Agency, London.
    • N. Keat, " CT scanner automatic exposure control systems.," Report No. 05016, Medicines and Healthcare Products Regulatory Agency, London, (2005).
    • (2005) CT Scanner Automatic Exposure Control Systems
    • Keat, N.1
  • 8
    • 34447131520 scopus 로고    scopus 로고
    • Performance evaluation for CT-AEC (CT automatic exposure control) systems
    • 10.6009/jjrt.63.534
    • Y. Muramatsu, " Performance evaluation for CT-AEC (CT automatic exposure control) systems.," Nihon Hoshasen Gijutsu Gakkai Zasshi 63, 534-545 (2007). 10.6009/jjrt.63.534
    • (2007) Nihon Hoshasen Gijutsu Gakkai Zasshi , vol.63 , pp. 534-545
    • Muramatsu, Y.1
  • 9
    • 48349112166 scopus 로고    scopus 로고
    • Development of a phantom to simulate a wide range of body sizes
    • Vol.
    • S. J. Lokitz, " Development of a phantom to simulate a wide range of body sizes.," IEEE Nuclear Science Symposium Conference Record, Vol. 5 (2007), pp. 3713-3717.
    • (2007) IEEE Nuclear Science Symposium Conference Record , vol.5 , pp. 3713-3717
    • Lokitz, S.J.1
  • 10
    • 34347392698 scopus 로고    scopus 로고
    • Automatic exposure control in multichannel CT with tube current modulation to achieve a constant level of image noise: Experimental assessment on pediatric phantoms
    • 10.1118/1.2746492
    • H. J. Brisse, " Automatic exposure control in multichannel CT with tube current modulation to achieve a constant level of image noise: Experimental assessment on pediatric phantoms.," Med. Phys. 34, 3018-3033 (2007). 10.1118/1.2746492
    • (2007) Med. Phys. , vol.34 , pp. 3018-3033
    • Brisse, H.J.1
  • 11
    • 38949105939 scopus 로고    scopus 로고
    • Effect of patient size on radiation dose for abdominal MDCT with automatic tube current modulation: Phantom study
    • 10.2214/AJR.07.2891
    • S. T. Schindera, " Effect of patient size on radiation dose for abdominal MDCT with automatic tube current modulation: Phantom study.," Am. J. Roentgenol. 190, W100-W105 (2008). 10.2214/AJR.07.2891
    • (2008) Am. J. Roentgenol. , vol.190
    • Schindera, S.T.1
  • 12
    • 0030241912 scopus 로고    scopus 로고
    • Spatial resolution properties of penalized-likelihood image reconstruction: Space-invariant tomographs
    • 10.1109/83.535846
    • J. A. Fessler and W. L. Rogers, " Spatial resolution properties of penalized-likelihood image reconstruction: Space-invariant tomographs.," IEEE Trans. Image Process. 5, 1346-1358 (1996). 10.1109/83.535846
    • (1996) IEEE Trans. Image Process. , vol.5 , pp. 1346-1358
    • Fessler, J.A.1    Rogers, W.L.2
  • 13
    • 35649025312 scopus 로고    scopus 로고
    • A three-dimensional statistical approach to improved image quality for multislice helical CT
    • 10.1118/1.2789499
    • J.-B. Thibault, " A three-dimensional statistical approach to improved image quality for multislice helical CT.," Med. Phys. 34, 4526-4544 (2007). 10.1118/1.2789499
    • (2007) Med. Phys. , vol.34 , pp. 4526-4544
    • Thibault, J.-B.1
  • 14
    • 75349092506 scopus 로고    scopus 로고
    • Low-tube-voltage, high-tube-current multidetector abdominal CT: Improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm-initial clinical experience
    • 10.1148/radiol.09090094
    • D. Marin, " Low-tube-voltage, high-tube-current multidetector abdominal CT: Improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm-initial clinical experience.," Radiology 254, 145-153 (2010). 10.1148/radiol.09090094
    • (2010) Radiology , vol.254 , pp. 145-153
    • Marin, D.1
  • 16
    • 69949096664 scopus 로고    scopus 로고
    • Iterative reconstruction technique for reducing body radiation dose at CT: Feasibility study
    • 10.2214/AJR.09.2397
    • A. K. Hara, " Iterative reconstruction technique for reducing body radiation dose at CT: Feasibility study.," Am. J. Roentgenol. 193, 764-771 (2009). 10.2214/AJR.09.2397
    • (2009) Am. J. Roentgenol. , vol.193 , pp. 764-771
    • Hara, A.K.1
  • 17
    • 79955761502 scopus 로고    scopus 로고
    • 3D noise power spectrum applied on clinical MDCT scanners: Effects of reconstruction algorithms and reconstruction filters
    • 10.1117/12.877809
    • F. A. Mieville, " 3D noise power spectrum applied on clinical MDCT scanners: Effects of reconstruction algorithms and reconstruction filters.," Proc. SPIE 7961, 79610E-79611E (2011). 10.1117/12.877809
    • (2011) Proc. SPIE , vol.7961
    • Mieville, F.A.1
  • 18
    • 1542409176 scopus 로고    scopus 로고
    • Patient size and x-ray transmission in body CT
    • 10.1097/00004032-200404000-00009
    • K. Ogden, " Patient size and x-ray transmission in body CT.," Health Phys. 86, 397-405 (2004). 10.1097/00004032-200404000-00009
    • (2004) Health Phys. , vol.86 , pp. 397-405
    • Ogden, K.1
  • 19
    • 78650106911 scopus 로고    scopus 로고
    • Anthropometric reference data for children and adults: United States, 2003-2006
    • M. A. McDowell, " Anthropometric reference data for children and adults: United States, 2003-2006.," Vital Health Stat. 10, 1-45 (2008).
    • (2008) Vital Health Stat. , vol.10 , pp. 1-45
    • McDowell, M.A.1
  • 21
    • 0033730872 scopus 로고    scopus 로고
    • Use of Wiener filtering in the measurement of the two-dimensional modulation transfer function
    • 10.1117/12.384546
    • D. A. Reimann, " Use of Wiener filtering in the measurement of the two-dimensional modulation transfer function.," Proc. SPIE 3977, 670-680 (2000). 10.1117/12.384546
    • (2000) Proc. SPIE , vol.3977 , pp. 670-680
    • Reimann, D.A.1
  • 22
    • 84874765747 scopus 로고    scopus 로고
    • Masters, thesis, Duke University.
    • S. Murphy, Masters, thesis, Duke University, 2011.
    • (2011)
    • Murphy, S.1
  • 23
    • 84864249070 scopus 로고    scopus 로고
    • Towards task-based assessment of CT performance: System and object MTF across different reconstruction algorithms
    • 10.1118/1.4725171
    • S. Richard, " Towards task-based assessment of CT performance: System and object MTF across different reconstruction algorithms.," Med. Phys. 39, 4115-4122 (2012). 10.1118/1.4725171
    • (2012) Med. Phys. , vol.39 , pp. 4115-4122
    • Richard, S.1
  • 24
    • 0037321550 scopus 로고    scopus 로고
    • Conditioning data for calculation of the modulation transfer function
    • 10.1118/1.1534111
    • A. D. Maidment and M. Albert, " Conditioning data for calculation of the modulation transfer function.," Med. Phys. 30, 248-253 (2003). 10.1118/1.1534111
    • (2003) Med. Phys. , vol.30 , pp. 248-253
    • Maidment, A.D.1    Albert, M.2
  • 25
    • 21144458392 scopus 로고    scopus 로고
    • Validation of MTF measurement for digital mammography quality control
    • 10.1118/1.1921667
    • A.-K. Carton, " Validation of MTF measurement for digital mammography quality control.," Med. Phys. 32, 1684-1695 (2005). 10.1118/1.1921667
    • (2005) Med. Phys. , vol.32 , pp. 1684-1695
    • Carton, A.-K.1
  • 26
    • 0031950889 scopus 로고    scopus 로고
    • A method for measuring the presampled MTF of digital radiographic systems using an edge test device
    • 10.1118/1.598165
    • E. Samei, " A method for measuring the presampled MTF of digital radiographic systems using an edge test device.," Med. Phys. 25, 102-113 (1998). 10.1118/1.598165
    • (1998) Med. Phys. , vol.25 , pp. 102-113
    • Samei, E.1
  • 27
    • 0032812524 scopus 로고    scopus 로고
    • Experimental comparison of noise and resolution for 2k and 4k storage phosphor radiography systems
    • 10.1118/1.598656
    • M. J. Flynn and E. Samei, " Experimental comparison of noise and resolution for 2k and 4k storage phosphor radiography systems.," Med. Phys. 26, 1612-1623 (1999). 10.1118/1.598656
    • (1999) Med. Phys. , vol.26 , pp. 1612-1623
    • Flynn, M.J.1    Samei, E.2
  • 29
    • 84863533966 scopus 로고    scopus 로고
    • Beyond noise power in 3D computed tomography: The local NPS and off-diagonal elements of the Fourier domain covariance matrix
    • 10.1118/1.4705354
    • A. R. Pineda, " Beyond noise power in 3D computed tomography: The local NPS and off-diagonal elements of the Fourier domain covariance matrix.," Med. Phys. 39, 3240-3252 (2012). 10.1118/1.4705354
    • (2012) Med. Phys. , vol.39 , pp. 3240-3252
    • Pineda, A.R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.