메뉴 건너뛰기




Volumn 71, Issue 3, 2014, Pages 1336-1347

A 1.5T MRI-conditional 12-lead electrocardiogram for MRI and intra-MR intervention

Author keywords

cardiac MRI; ECG; magneto hydro dynamic effect; MRI guided interventions

Indexed keywords

ADAPTIVE FILTERING; ADAPTIVE FILTERS; FLUID DYNAMICS; PATIENT MONITORING; PATIENT TREATMENT; SHEAR WAVES; SWITCHING CIRCUITS;

EID: 84894411284     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24744     Document Type: Article
Times cited : (51)

References (24)
  • 1
    • 33847354863 scopus 로고    scopus 로고
    • Recommendations for the standardization and interpretation of the electrocardiogram
    • Kligfield P, Gettes LS, Bailey JJ, et al. Recommendations for the standardization and interpretation of the electrocardiogram. I. The electrocardiogram and its technology: a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society. Endorsed by the International Society for Computerized Electrocardiology. Heart Rhythm 2007; 4: 394-412.
    • (2007) Heart Rhythm , vol.4 , pp. 394-412
    • Kligfield, P.1    Gettes, L.S.2    Bailey, J.J.3
  • 3
    • 0023151719 scopus 로고
    • Optimizing electrocardiograph electrode placement for cardiac-gated magnetic resonance imaging
    • Dimich RN, Hedlund LW, Herfkens RJ, Fram EK, Utz J,. Optimizing electrocardiograph electrode placement for cardiac-gated magnetic resonance imaging. Invest Radiol 1987; 22: 17-22.
    • (1987) Invest Radiol , vol.22 , pp. 17-22
    • Dimich, R.N.1    Hedlund, L.W.2    Herfkens, R.J.3    Fram, E.K.4    Utz, J.5
  • 4
    • 0032873080 scopus 로고    scopus 로고
    • Novel real-time R-wave detection algorithm based on the vector cardiogram for accurate gated magnetic resonance acquisitions
    • Fischer SE, Wickline SA, Lorenz CH,. Novel real-time R-wave detection algorithm based on the vector cardiogram for accurate gated magnetic resonance acquisitions. Magn Reson Med 1999; 42: 361-370.
    • (1999) Magn Reson Med , vol.42 , pp. 361-370
    • Fischer, S.E.1    Wickline, S.A.2    Lorenz, C.H.3
  • 5
    • 17744363268 scopus 로고    scopus 로고
    • Suppression of MR gradient artefacts on electrophysiological signals based on an adaptive real-time filter with LMS coefficient updates
    • Abächerli R, Pasquier C, Odille F, Kraemer M, Schmid JJ, Felblinger J,. Suppression of MR gradient artefacts on electrophysiological signals based on an adaptive real-time filter with LMS coefficient updates. Magn Reson Mater Phys Biol Med 2005; 18: 41-50.
    • (2005) Magn Reson Mater Phys Biol Med , vol.18 , pp. 41-50
    • Abächerli, R.1    Pasquier, C.2    Odille, F.3    Kraemer, M.4    Schmid, J.J.5    Felblinger, J.6
  • 6
    • 84894430679 scopus 로고    scopus 로고
    • Standard test method for measurement of radio frequency induced heating on or near passive implants during magnetic resonance imaging
    • ASTM-F2182
    • ASTM-F2182. Standard test method for measurement of radio frequency induced heating on or near passive implants during magnetic resonance imaging. Conshohocken, PA: American Society for Testing and Materials; 2011.
    • (2011) Conshohocken, PA: American Society for Testing and Materials
  • 7
    • 44349138879 scopus 로고    scopus 로고
    • Testing MR safety and compatibility
    • Schaefers G,. Testing MR safety and compatibility. IEEE Eng Med Biol Mag 2008; 27: 23-27.
    • (2008) IEEE Eng Med Biol Mag , vol.27 , pp. 23-27
    • Schaefers, G.1
  • 8
    • 34249051660 scopus 로고    scopus 로고
    • Electric fields induced in the human body by time-varying magnetic field gradients in MRI: Numerical calculations and correlation analysis
    • Bencsik M, Bowtell R, Bowley R,. Electric fields induced in the human body by time-varying magnetic field gradients in MRI: numerical calculations and correlation analysis. Phys Med Biol 2007; 52: 2337-2346.
    • (2007) Phys Med Biol , vol.52 , pp. 2337-2346
    • Bencsik, M.1    Bowtell, R.2    Bowley, R.3
  • 9
    • 33947521715 scopus 로고    scopus 로고
    • Noise cancellation signal processing method and computer system for improved real-time electrocardiogram artifact correction during MRI data acquisition
    • Odille F, Pasquier C, Abacherli R, Vuissoz PA, Zientara GP, Felblinger J,. Noise cancellation signal processing method and computer system for improved real-time electrocardiogram artifact correction during MRI data acquisition. IEEE Trans Biomed Eng 2007; 54: 630-640.
    • (2007) IEEE Trans Biomed Eng , vol.54 , pp. 630-640
    • Odille, F.1    Pasquier, C.2    Abacherli, R.3    Vuissoz, P.A.4    Zientara, G.P.5    Felblinger, J.6
  • 10
    • 77953730345 scopus 로고    scopus 로고
    • Nonlinear Bayesian filtering for denoising of electrocardiograms acquired in a magnetic resonance environment
    • Oster J, Pietquin O, Kraemer M, Felblinger J,. Nonlinear Bayesian filtering for denoising of electrocardiograms acquired in a magnetic resonance environment. IEEE Trans Biomed Eng 2010; 57: 1628-1638.
    • (2010) IEEE Trans Biomed Eng , vol.57 , pp. 1628-1638
    • Oster, J.1    Pietquin, O.2    Kraemer, M.3    Felblinger, J.4
  • 11
    • 76249092383 scopus 로고    scopus 로고
    • Independent component analysis-based artefact reduction: Application to the electrocardiogram for improved magnetic resonance imaging triggering
    • Oster J, Pietquin O, Abächerli R, Kraemer M, Felblinger J,. Independent component analysis-based artefact reduction: application to the electrocardiogram for improved magnetic resonance imaging triggering. Physiol Meas 2009; 30: 1381-1397.
    • (2009) Physiol Meas , vol.30 , pp. 1381-1397
    • Oster, J.1    Pietquin, O.2    Abächerli, R.3    Kraemer, M.4    Felblinger, J.5
  • 12
    • 45749142880 scopus 로고    scopus 로고
    • Simulation of elevated T-waves of an ECG inside a static magnetic field (MRI)
    • Gupta A, Weeks AR, Richie SM,. Simulation of elevated T-waves of an ECG inside a static magnetic field (MRI). IEEE Trans Biomed Eng 2008; 55: 1890-1896.
    • (2008) IEEE Trans Biomed Eng , vol.55 , pp. 1890-1896
    • Gupta, A.1    Weeks, A.R.2    Richie, S.M.3
  • 13
    • 45849107967 scopus 로고    scopus 로고
    • Extraction of the magnetohydrodynamic blood flow potential from the surface electrocardiogram in magnetic resonance imaging
    • Nijm G, Swiryn S, Larson A, Sahakian A,. Extraction of the magnetohydrodynamic blood flow potential from the surface electrocardiogram in magnetic resonance imaging. Med Biol Eng Comput 2008; 46: 729-733.
    • (2008) Med Biol Eng Comput , vol.46 , pp. 729-733
    • Nijm, G.1    Swiryn, S.2    Larson, A.3    Sahakian, A.4
  • 19
    • 35848942605 scopus 로고    scopus 로고
    • Standards for medical devices in MRI: Present and future
    • Woods TO,. Standards for medical devices in MRI: present and future. J Magn Reson Imaging 2007; 26: 1186-1189.
    • (2007) J Magn Reson Imaging , vol.26 , pp. 1186-1189
    • Woods, T.O.1
  • 21
    • 0029685722 scopus 로고    scopus 로고
    • Theoretical analysis of magnetic field interactions with aortic blood flow
    • Kinouchi Y, Yamaguchi H, Tenforde TS,. Theoretical analysis of magnetic field interactions with aortic blood flow. Bioelectromagnetics 1996; 17: 21-32.
    • (1996) Bioelectromagnetics , vol.17 , pp. 21-32
    • Kinouchi, Y.1    Yamaguchi, H.2    Tenforde, T.S.3
  • 22
    • 0042553279 scopus 로고
    • Smoothing and differentiation of data by simplified least squares procedures
    • Savitzky A, Golay MJE,. Smoothing and differentiation of data by simplified least squares procedures. Anal Chem 1964; 36: 1627-1639.
    • (1964) Anal Chem , vol.36 , pp. 1627-1639
    • Savitzky, A.1    Golay, M.J.E.2
  • 23
  • 24
    • 0036399595 scopus 로고    scopus 로고
    • Postextrasystolic regulation patterns of blood pressure and heart rate in patients with idiopathic dilated cardiomyopathy
    • Voss A, Baier V, Schumann A, Hasart A, Reinsperger F, Schirdewan A, Osterziel K-J, Leder U,. Postextrasystolic regulation patterns of blood pressure and heart rate in patients with idiopathic dilated cardiomyopathy. J Physiol 2002; 538: 271-278
    • (2002) J Physiol , vol.538 , pp. 271-278
    • Voss, A.1    Baier, V.2    Schumann, A.3    Hasart, A.4    Reinsperger, F.5    Schirdewan, A.6    Osterziel, K.-J.7    Leder, U.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.