-
1
-
-
0002142139
-
Galvanometrische registratie van het menschelijk electrocardiogram
-
Eduard Ijdo, Leiden, Netherlands
-
Einthoven W. Galvanometrische registratie van het menschelijk electrocardiogram. Herinneringsbundel Professor S. S. Rosenstein (1902), Eduard Ijdo, Leiden, Netherlands 101-106
-
(1902)
Herinneringsbundel Professor S. S. Rosenstein
, pp. 101-106
-
-
Einthoven, W.1
-
2
-
-
0036938422
-
The centennial of the Einthoven electrocardiogram
-
Kligfield P. The centennial of the Einthoven electrocardiogram. J Electrocardiol 35 Suppl (2002) 123-129
-
(2002)
J Electrocardiol
, vol.35
, Issue.SUPPL
, pp. 123-129
-
-
Kligfield, P.1
-
3
-
-
0028773534
-
A history of the origin, evolution, and impact of electrocardiography
-
[published correction appears in Am J Cardiol 1995;76:641]
-
Fye W.B. A history of the origin, evolution, and impact of electrocardiography. [published correction appears in Am J Cardiol 1995;76:641]. Am J Cardiol 73 (1994) 937-949
-
(1994)
Am J Cardiol
, vol.73
, pp. 937-949
-
-
Fye, W.B.1
-
4
-
-
0026508953
-
Guidelines for electrocardiography: a report of the American College of Cardiology/American Heart Association Task Force on Assessment of Diagnostic and Therapeutic Cardiovascular Procedures (Committee on Electrocardiography)
-
Schlant R.C., Adolph R.J., DiMarco J.P., et al. Guidelines for electrocardiography: a report of the American College of Cardiology/American Heart Association Task Force on Assessment of Diagnostic and Therapeutic Cardiovascular Procedures (Committee on Electrocardiography). Circulation 85 (1992) 1221-1228
-
(1992)
Circulation
, vol.85
, pp. 1221-1228
-
-
Schlant, R.C.1
Adolph, R.J.2
DiMarco, J.P.3
-
5
-
-
0001904877
-
Recommendations for standardization of leads and of specifications for instruments in electrocardiography and vectorcardiography: report of the Committee on Electrocardiography
-
Pipberger H.V., Arzbaecher R.C., Berson A.S., et al. Recommendations for standardization of leads and of specifications for instruments in electrocardiography and vectorcardiography: report of the Committee on Electrocardiography. Circulation 52 (1975) 11-31
-
(1975)
Circulation
, vol.52
, pp. 11-31
-
-
Pipberger, H.V.1
Arzbaecher, R.C.2
Berson, A.S.3
-
6
-
-
0017843452
-
The quest for optimal electrocardiography: Task Force IA: development of a data base for electrocardiographic use
-
Hagan A., Bloor C., Borun R., et al. The quest for optimal electrocardiography: Task Force IA: development of a data base for electrocardiographic use. Am J Cardiol 41 (1978) 145-146
-
(1978)
Am J Cardiol
, vol.41
, pp. 145-146
-
-
Hagan, A.1
Bloor, C.2
Borun, R.3
-
7
-
-
0017855979
-
The quest for optimal electrocardiography
-
Horan L.G. The quest for optimal electrocardiography. Am J Cardiol 41 (1978) 126-129
-
(1978)
Am J Cardiol
, vol.41
, pp. 126-129
-
-
Horan, L.G.1
-
8
-
-
0018279103
-
Computerized ECG analysis
-
Phibbs B. Computerized ECG analysis. JAMA 240 (1978) 1481-1482
-
(1978)
JAMA
, vol.240
, pp. 1481-1482
-
-
Phibbs, B.1
-
9
-
-
0017808168
-
The quest for optimal electrocardiography: Task Force III: computers in diagnostic electrocardiography
-
Rautaharju P.M., Ariet M., Pryor T.A., et al. The quest for optimal electrocardiography: Task Force III: computers in diagnostic electrocardiography. Am J Cardiol 41 (1978) 158-170
-
(1978)
Am J Cardiol
, vol.41
, pp. 158-170
-
-
Rautaharju, P.M.1
Ariet, M.2
Pryor, T.A.3
-
10
-
-
0017907509
-
The quest for optimal electrocardiography: Task Force IV: use of electrocardiograms in practice
-
Resnekov L., Fox S., Selzer A., et al. The quest for optimal electrocardiography: Task Force IV: use of electrocardiograms in practice. Am J Cardiol 41 (1978) 170-175
-
(1978)
Am J Cardiol
, vol.41
, pp. 170-175
-
-
Resnekov, L.1
Fox, S.2
Selzer, A.3
-
11
-
-
0017916040
-
The quest for optimal electrocardiography: Task Force V: cost effectiveness of the electrocardiogram
-
Rios J., Sandquist F., Ramseth D., Stratbucker R., Drazen E., and Hanmer J. The quest for optimal electrocardiography: Task Force V: cost effectiveness of the electrocardiogram. Am J Cardiol 41 (1978) 175-183
-
(1978)
Am J Cardiol
, vol.41
, pp. 175-183
-
-
Rios, J.1
Sandquist, F.2
Ramseth, D.3
Stratbucker, R.4
Drazen, E.5
Hanmer, J.6
-
12
-
-
0017801332
-
The quest for optimal electrocardiography: Task Force II: quality of electrocardiographic records
-
Sheffield L.T., Prineas R., Cohen H.C., Schoenberg A., and Froelicher V. The quest for optimal electrocardiography: Task Force II: quality of electrocardiographic records. Am J Cardiol 41 (1978) 146-157
-
(1978)
Am J Cardiol
, vol.41
, pp. 146-157
-
-
Sheffield, L.T.1
Prineas, R.2
Cohen, H.C.3
Schoenberg, A.4
Froelicher, V.5
-
13
-
-
0017840492
-
The quest for optimal electrocardiography: Task Force I: standardization of terminology and interpretation
-
Surawicz B., Uhley H., Borun R., et al. The quest for optimal electrocardiography: Task Force I: standardization of terminology and interpretation. Am J Cardiol 41 (1978) 130-145
-
(1978)
Am J Cardiol
, vol.41
, pp. 130-145
-
-
Surawicz, B.1
Uhley, H.2
Borun, R.3
-
14
-
-
0017907510
-
The quest for optimal electrocardiography: Task Force VI: future directions in electrocardiography
-
Zipes D.P., Spach M.S., Holt J.H., Gallagher J.J., Lazzara R., and Boineau J.P. The quest for optimal electrocardiography: Task Force VI: future directions in electrocardiography. Am J Cardiol 41 (1978) 184-191
-
(1978)
Am J Cardiol
, vol.41
, pp. 184-191
-
-
Zipes, D.P.1
Spach, M.S.2
Holt, J.H.3
Gallagher, J.J.4
Lazzara, R.5
Boineau, J.P.6
-
15
-
-
0026410610
-
The diagnostic performance of computer programs for the interpretation of electrocardiograms
-
Willems J.L., Abreu-Lima C., Arnaud P., et al. The diagnostic performance of computer programs for the interpretation of electrocardiograms. N Engl J Med 325 (1991) 1767-1773
-
(1991)
N Engl J Med
, vol.325
, pp. 1767-1773
-
-
Willems, J.L.1
Abreu-Lima, C.2
Arnaud, P.3
-
16
-
-
0038412639
-
Competency in interpretation of 12-lead electrocardiograms: a summary and appraisal of published evidence
-
Salerno S.M., Alguire P.C., and Waxman H.S. Competency in interpretation of 12-lead electrocardiograms: a summary and appraisal of published evidence. Ann Intern Med 138 (2003) 751-760
-
(2003)
Ann Intern Med
, vol.138
, pp. 751-760
-
-
Salerno, S.M.1
Alguire, P.C.2
Waxman, H.S.3
-
17
-
-
0021964239
-
Assessment of the performance of electrocardiographic computer programs with the use of a reference data base
-
Willems J.L., Arnaud P., van Bemmel J.H., et al. Assessment of the performance of electrocardiographic computer programs with the use of a reference data base. Circulation 71 (1985) 523-534
-
(1985)
Circulation
, vol.71
, pp. 523-534
-
-
Willems, J.L.1
Arnaud, P.2
van Bemmel, J.H.3
-
18
-
-
0038412637
-
Training and competency evaluation for interpretation of 12-lead electrocardiograms: recommendations from the American College of Physicians
-
American College of Physicians
-
Salerno S.M., Alguire P.C., Waxman H.S., and American College of Physicians. Training and competency evaluation for interpretation of 12-lead electrocardiograms: recommendations from the American College of Physicians. Ann Intern Med 138 (2003) 747-750
-
(2003)
Ann Intern Med
, vol.138
, pp. 747-750
-
-
Salerno, S.M.1
Alguire, P.C.2
Waxman, H.S.3
-
19
-
-
0018843973
-
A plea for common standards in computer aided ECG analysis
-
Willems J.L. A plea for common standards in computer aided ECG analysis. Comput Biomed Res 13 (1980) 120-131
-
(1980)
Comput Biomed Res
, vol.13
, pp. 120-131
-
-
Willems, J.L.1
-
20
-
-
0022122152
-
Common standards for quantitative electrocardiography
-
Willems J.L. Common standards for quantitative electrocardiography. J Med Eng Technol 9 (1985) 209-217
-
(1985)
J Med Eng Technol
, vol.9
, pp. 209-217
-
-
Willems, J.L.1
-
21
-
-
0022385397
-
Recommendations for measurement standards in quantitative electrocardiography
-
The CSE Working Party
-
The CSE Working Party. Recommendations for measurement standards in quantitative electrocardiography. Eur Heart J 6 (1985) 815-825
-
(1985)
Eur Heart J
, vol.6
, pp. 815-825
-
-
-
22
-
-
0025160665
-
Common standards for quantitative electrocardiography: goals and main results
-
CSE Working Party
-
Willems J.L., Arnaud P., van Bemmel J.H., Degani R., Macfarlane P.W., Zywietz C., and CSE Working Party. Common standards for quantitative electrocardiography: goals and main results. Methods Inf Med 29 (1990) 263-271
-
(1990)
Methods Inf Med
, vol.29
, pp. 263-271
-
-
Willems, J.L.1
Arnaud, P.2
van Bemmel, J.H.3
Degani, R.4
Macfarlane, P.W.5
Zywietz, C.6
-
23
-
-
0025095175
-
Recommendations for standardization and specifications in automated electrocardiography: bandwidth and digital signal processing: a report for health professionals by an ad hoc writing group of the Committee on Electrocardiography and Cardiac Electrophysiology of the Council on Clinical Cardiology, American Heart Association
-
Bailey J.J., Berson A.S., Garson Jr. A., et al. Recommendations for standardization and specifications in automated electrocardiography: bandwidth and digital signal processing: a report for health professionals by an ad hoc writing group of the Committee on Electrocardiography and Cardiac Electrophysiology of the Council on Clinical Cardiology, American Heart Association. Circulation 81 (1990) 730-739
-
(1990)
Circulation
, vol.81
, pp. 730-739
-
-
Bailey, J.J.1
Berson, A.S.2
Garson Jr., A.3
-
24
-
-
33847364366
-
-
American National Standards Institute, Association for the Advancement of Medical Instrumentation, Arlington, VA
-
American National Standards Institute. Diagnostic electrocardiographic devices (ANSI/AAMI EC11:1991/(R)2001) (2000), Association for the Advancement of Medical Instrumentation, Arlington, VA
-
(2000)
Diagnostic electrocardiographic devices (ANSI/AAMI EC11:1991/(R)2001)
-
-
-
25
-
-
0026879873
-
Guidelines for judicious use of electrocardiography: a summary of recommendations from the ACC/AHA Task Force Report
-
Swan H.J. Guidelines for judicious use of electrocardiography: a summary of recommendations from the ACC/AHA Task Force Report. J Crit Illn 7 (1992) 861-870
-
(1992)
J Crit Illn
, vol.7
, pp. 861-870
-
-
Swan, H.J.1
-
26
-
-
0028932592
-
Clinical competence in electrocardiography: a statement for physicians from the ACP/ACC/AHA Task Force on clinical privileges in cardiology
-
Fisch C. Clinical competence in electrocardiography: a statement for physicians from the ACP/ACC/AHA Task Force on clinical privileges in cardiology. J Am Coll Cardiol 25 (1995) 1465-1469
-
(1995)
J Am Coll Cardiol
, vol.25
, pp. 1465-1469
-
-
Fisch, C.1
-
27
-
-
0035909998
-
ACC/AHA clinical competence statement on electrocardiography and ambulatory electrocardiography: a report of the ACC/AHA/ACP-ASIM task force on clinical competence (ACC/AHA committee to develop a clinical competence statement on electrocardiography and ambulatory electrocardiography) endorsed by the International Society for Holter and noninvasive electrocardiology
-
Kadish A.H., Buxton A.E., Kennedy H.L., et al. ACC/AHA clinical competence statement on electrocardiography and ambulatory electrocardiography: a report of the ACC/AHA/ACP-ASIM task force on clinical competence (ACC/AHA committee to develop a clinical competence statement on electrocardiography and ambulatory electrocardiography) endorsed by the International Society for Holter and noninvasive electrocardiology. Circulation 104 (2001) 3169-3178
-
(2001)
Circulation
, vol.104
, pp. 3169-3178
-
-
Kadish, A.H.1
Buxton, A.E.2
Kennedy, H.L.3
-
29
-
-
0025076163
-
Classification methods for computerized interpretation of the electrocardiogram
-
Kors J.A., and van Bemmel J.H. Classification methods for computerized interpretation of the electrocardiogram. Methods Inf Med 29 (1990) 330-336
-
(1990)
Methods Inf Med
, vol.29
, pp. 330-336
-
-
Kors, J.A.1
van Bemmel, J.H.2
-
30
-
-
28144441949
-
Über die Richtung und die manifeste Grösse der Potentialschwankungen im menschlichen Herzen and über den Einfluss der Herzlage auf die Form des Electrokardiogramms
-
Einthoven W., Fahr G., and de Waart A. Über die Richtung und die manifeste Grösse der Potentialschwankungen im menschlichen Herzen and über den Einfluss der Herzlage auf die Form des Electrokardiogramms. Arch des Physiol 150 (1913) 275-315
-
(1913)
Arch des Physiol
, vol.150
, pp. 275-315
-
-
Einthoven, W.1
Fahr, G.2
de Waart, A.3
-
32
-
-
0345092302
-
Heart-vector and leads. Part III: geometrical representation
-
Burger H.C., and van Milaan J.B. Heart-vector and leads. Part III: geometrical representation. Br Heart J 10 (1948) 229-233
-
(1948)
Br Heart J
, vol.10
, pp. 229-233
-
-
Burger, H.C.1
van Milaan, J.B.2
-
33
-
-
0000152912
-
Lead theory
-
Macfarlane P.W., and Lawrie T.D.V. (Eds), Pergamon Press, New York, NY
-
Horacek B.M. Lead theory. In: Macfarlane P.W., and Lawrie T.D.V. (Eds). Comprehensive Electrocardiology: Theory and Practice in Health and Disease (1989), Pergamon Press, New York, NY 291-314
-
(1989)
Comprehensive Electrocardiology: Theory and Practice in Health and Disease
, pp. 291-314
-
-
Horacek, B.M.1
-
34
-
-
0017398465
-
Solid angle theory and the electrocardiogram: physiologic and quantitative interpretations
-
Holland R.P., and Arnsdorf M.P. Solid angle theory and the electrocardiogram: physiologic and quantitative interpretations. Prog Cardiovasc Dis 19 (1977) 431-457
-
(1977)
Prog Cardiovasc Dis
, vol.19
, pp. 431-457
-
-
Holland, R.P.1
Arnsdorf, M.P.2
-
35
-
-
0035910003
-
Minimum bandwidth requirements for recording of pediatric electrocardiograms
-
Rijnbeek P.R., Kors J.A., and Witsenburg M. Minimum bandwidth requirements for recording of pediatric electrocardiograms. Circulation 104 (2001) 3087-3090
-
(2001)
Circulation
, vol.104
, pp. 3087-3090
-
-
Rijnbeek, P.R.1
Kors, J.A.2
Witsenburg, M.3
-
36
-
-
0023641181
-
Stability of ECG amplitude measurements in systematic noise tests: results and recommendations from the CSE project
-
Zywietz C., and Willems J.L. Stability of ECG amplitude measurements in systematic noise tests: results and recommendations from the CSE project. J Electrocardiol 20 Suppl (1987) 61-67
-
(1987)
J Electrocardiol
, vol.20
, Issue.SUPPL
, pp. 61-67
-
-
Zywietz, C.1
Willems, J.L.2
-
37
-
-
0030469502
-
Influence of ECG measurement accuracy on ECG diagnostic statements
-
Zywietz C., Celikag D., and Joseph G. Influence of ECG measurement accuracy on ECG diagnostic statements. J Electrocardiol 29 Suppl (1996) 67-72
-
(1996)
J Electrocardiol
, vol.29
, Issue.SUPPL
, pp. 67-72
-
-
Zywietz, C.1
Celikag, D.2
Joseph, G.3
-
38
-
-
13844317099
-
Technical aspects of electrocardiogram recording
-
Macfarlane P.W., and Lawrie T.D.V. (Eds), Pergamon Press, New York, NY
-
Zywietz C. Technical aspects of electrocardiogram recording. In: Macfarlane P.W., and Lawrie T.D.V. (Eds). Comprehensive Electrocardiology: Theory and Practice in Health and Disease (1989), Pergamon Press, New York, NY 353-404
-
(1989)
Comprehensive Electrocardiology: Theory and Practice in Health and Disease
, pp. 353-404
-
-
Zywietz, C.1
-
39
-
-
0020042066
-
Frequency response characteristics of ambulatory ECG monitoring systems and their implications for ST segment analysis
-
Bragg-Remschel D.A., Anderson C.M., and Winkle R.A. Frequency response characteristics of ambulatory ECG monitoring systems and their implications for ST segment analysis. Am Heart J 103 (1982) 20-31
-
(1982)
Am Heart J
, vol.103
, pp. 20-31
-
-
Bragg-Remschel, D.A.1
Anderson, C.M.2
Winkle, R.A.3
-
40
-
-
0013920022
-
The low-frequency response of electrocardiographs, a frequent source of recording errors
-
Berson A.S., and Pipberger H.V. The low-frequency response of electrocardiographs, a frequent source of recording errors. Am Heart J 71 (1966) 779-789
-
(1966)
Am Heart J
, vol.71
, pp. 779-789
-
-
Berson, A.S.1
Pipberger, H.V.2
-
41
-
-
0024955587
-
Suppression of baseline wander in the ECG using a bilinearly transformed, null-phase filter
-
Pottala E.W., Bailey J.J., Horton M.R., and Gradwohl J.R. Suppression of baseline wander in the ECG using a bilinearly transformed, null-phase filter. J Electrocardiol 22 Suppl (1989) 243-247
-
(1989)
J Electrocardiol
, vol.22
, Issue.SUPPL
, pp. 243-247
-
-
Pottala, E.W.1
Bailey, J.J.2
Horton, M.R.3
Gradwohl, J.R.4
-
42
-
-
0017730850
-
Digital filters for ECG signals
-
Institute of Electrical and Electronics Engineers, New York, NY
-
Mortara D.W. Digital filters for ECG signals. Computers in Cardiology (1977), Institute of Electrical and Electronics Engineers, New York, NY 511-514
-
(1977)
Computers in Cardiology
, pp. 511-514
-
-
Mortara, D.W.1
-
43
-
-
27844470711
-
Sampling rate of ECGs in relation to measurement accuracy
-
Wagner G.S., Scherlag B.G., and Bailey J.J. (Eds), Engineering Foundation, New York, NY
-
Zywietz C. Sampling rate of ECGs in relation to measurement accuracy. In: Wagner G.S., Scherlag B.G., and Bailey J.J. (Eds). Computerized Interpretation of the Electrocardiogram (1986), Engineering Foundation, New York, NY 122-125
-
(1986)
Computerized Interpretation of the Electrocardiogram
, pp. 122-125
-
-
Zywietz, C.1
-
44
-
-
0014114883
-
Electrocardiographic distortions caused by inadequate high-frequency response of direct-writing electrocardiographs
-
Berson A.S., and Pipberger H.V. Electrocardiographic distortions caused by inadequate high-frequency response of direct-writing electrocardiographs. Am Heart J 74 (1967) 208-218
-
(1967)
Am Heart J
, vol.74
, pp. 208-218
-
-
Berson, A.S.1
Pipberger, H.V.2
-
45
-
-
0023485867
-
Is a higher sampling rate desirable in the computer processing of the pediatric electrocardiogram?
-
Yamamoto H., Miyahara H., and Domae A. Is a higher sampling rate desirable in the computer processing of the pediatric electrocardiogram?. J Electrocardiol 20 (1987) 321-328
-
(1987)
J Electrocardiol
, vol.20
, pp. 321-328
-
-
Yamamoto, H.1
Miyahara, H.2
Domae, A.3
-
46
-
-
0024954598
-
Normal limits of the high-fidelity pediatric ECG: preliminary observations
-
Macfarlane P.W., Coleman E.N., Pomphrey E.O., McLaughlin S., Houston A., and Aitchison T. Normal limits of the high-fidelity pediatric ECG: preliminary observations. J Electrocardiol 22 Suppl (1989) 162-168
-
(1989)
J Electrocardiol
, vol.22
, Issue.SUPPL
, pp. 162-168
-
-
Macfarlane, P.W.1
Coleman, E.N.2
Pomphrey, E.O.3
McLaughlin, S.4
Houston, A.5
Aitchison, T.6
-
47
-
-
0000070174
-
High-frequency components in the electrocardiograms of normal subjects and of patients with coronary heart disease
-
Langner Jr. P.H., Geselowitz D.B., Mansure F.T., and Lauer J.A. High-frequency components in the electrocardiograms of normal subjects and of patients with coronary heart disease. Am Heart J 62 (1961) 746-755
-
(1961)
Am Heart J
, vol.62
, pp. 746-755
-
-
Langner Jr., P.H.1
Geselowitz, D.B.2
Mansure, F.T.3
Lauer, J.A.4
-
48
-
-
0015784985
-
Wide band recording of the electrocardiogram and coronary heart disease
-
Langner Jr. P.H., Geselowitz D.B., and Briller S.A. Wide band recording of the electrocardiogram and coronary heart disease. Am Heart J 86 (1973) 308-317
-
(1973)
Am Heart J
, vol.86
, pp. 308-317
-
-
Langner Jr., P.H.1
Geselowitz, D.B.2
Briller, S.A.3
-
50
-
-
0029559534
-
Changes in high-frequency QRS components during prolonged coronary artery occlusion in humans
-
Pettersson J., Warren S., Mehta N., et al. Changes in high-frequency QRS components during prolonged coronary artery occlusion in humans. J Electrocardiol 28 Suppl (1995) 225-227
-
(1995)
J Electrocardiol
, vol.28
, Issue.SUPPL
, pp. 225-227
-
-
Pettersson, J.1
Warren, S.2
Mehta, N.3
-
51
-
-
0033983461
-
Spatial, individual, and temporal variation of the high-frequency QRS amplitudes in the 12 standard electrocardiographic leads
-
Pettersson J., Carro E., Edenbrandt L., et al. Spatial, individual, and temporal variation of the high-frequency QRS amplitudes in the 12 standard electrocardiographic leads. Am Heart J 139 (2000) 352-358
-
(2000)
Am Heart J
, vol.139
, pp. 352-358
-
-
Pettersson, J.1
Carro, E.2
Edenbrandt, L.3
-
52
-
-
0023182059
-
Clinically significant differences between the "old" analog and the "new" digital electrocardiograms
-
Garson Jr. A. Clinically significant differences between the "old" analog and the "new" digital electrocardiograms. Am Heart J 114 (1987) 194-197
-
(1987)
Am Heart J
, vol.114
, pp. 194-197
-
-
Garson Jr., A.1
-
53
-
-
0033390006
-
Using digital versus analog ECG data in clinical trials
-
Warner R.A., and Hill N.E. Using digital versus analog ECG data in clinical trials. J Electrocardiol 32 Suppl (1999) 103-107
-
(1999)
J Electrocardiol
, vol.32
, Issue.SUPPL
, pp. 103-107
-
-
Warner, R.A.1
Hill, N.E.2
-
54
-
-
0023492181
-
Influence of noise on wave boundary recognition by ECG measurement programs: recommendations for preprocessing
-
Willems J.L., Zywietz C., Arnaud P., van Bemmel J.H., Degani R., and Macfarlane P.W. Influence of noise on wave boundary recognition by ECG measurement programs: recommendations for preprocessing. Comput Biomed Res 20 (1987) 543-562
-
(1987)
Comput Biomed Res
, vol.20
, pp. 543-562
-
-
Willems, J.L.1
Zywietz, C.2
Arnaud, P.3
van Bemmel, J.H.4
Degani, R.5
Macfarlane, P.W.6
-
55
-
-
0025361546
-
Stability of computer ECG amplitude measurements in the presence of noise
-
CSE Working Party
-
Zywietz C., Willems J.L., Arnaud P., et al., CSE Working Party. Stability of computer ECG amplitude measurements in the presence of noise. Comput Biomed Res 23 (1990) 10-31
-
(1990)
Comput Biomed Res
, vol.23
, pp. 10-31
-
-
Zywietz, C.1
Willems, J.L.2
Arnaud, P.3
-
56
-
-
0030466738
-
Analysis of interval measurements on CSE multilead reference ECGs
-
Reddy B.R., Xue Q., and Zywietz C. Analysis of interval measurements on CSE multilead reference ECGs. J Electrocardiol 29 Suppl (1996) 62-66
-
(1996)
J Electrocardiol
, vol.29
, Issue.SUPPL
, pp. 62-66
-
-
Reddy, B.R.1
Xue, Q.2
Zywietz, C.3
-
57
-
-
0026786338
-
Variability in ECG computer interpretation: analysis of individual complexes vs analysis of a representative complex
-
Kors J.A., van Herpen G., and van Bemmel J.H. Variability in ECG computer interpretation: analysis of individual complexes vs analysis of a representative complex. J Electrocardiol 25 (1992) 263-271
-
(1992)
J Electrocardiol
, vol.25
, pp. 263-271
-
-
Kors, J.A.1
van Herpen, G.2
van Bemmel, J.H.3
-
58
-
-
0031895983
-
Algorithms for computerized QT analysis
-
Xue Q., and Reddy S. Algorithms for computerized QT analysis. J Electrocardiol 30 Suppl (1998) 181-186
-
(1998)
J Electrocardiol
, vol.30
, Issue.SUPPL
, pp. 181-186
-
-
Xue, Q.1
Reddy, S.2
-
59
-
-
2342604494
-
Comparing methods of measurement for detecting drug-induced changes in the QT interval: implications for thoroughly conducted ECG studies
-
Azie N.E., Adams G., Darpo B., et al. Comparing methods of measurement for detecting drug-induced changes in the QT interval: implications for thoroughly conducted ECG studies. Ann Noninvasive Electrocardiol 9 (2004) 166-174
-
(2004)
Ann Noninvasive Electrocardiol
, vol.9
, pp. 166-174
-
-
Azie, N.E.1
Adams, G.2
Darpo, B.3
-
60
-
-
0032445798
-
Determinants of precordial QT dispersion in normal subjects
-
Lee K.W., Kligfield P., Okin P.M., and Dower G.E. Determinants of precordial QT dispersion in normal subjects. J Electrocardiol 31 Suppl (1998) 128-133
-
(1998)
J Electrocardiol
, vol.31
, Issue.SUPPL
, pp. 128-133
-
-
Lee, K.W.1
Kligfield, P.2
Okin, P.M.3
Dower, G.E.4
-
61
-
-
0031728902
-
Measurement error as a source of QT dispersion: a computerised analysis
-
Kors J.A., and van Herpen G. Measurement error as a source of QT dispersion: a computerised analysis. Heart 80 (1998) 453-458
-
(1998)
Heart
, vol.80
, pp. 453-458
-
-
Kors, J.A.1
van Herpen, G.2
-
63
-
-
0024502557
-
Normal limits of the electrocardiogram in a Chinese population
-
Chen C.Y., Chiang B.N., and Macfarlane P.W. Normal limits of the electrocardiogram in a Chinese population. J Electrocardiol 22 (1989) 1-15
-
(1989)
J Electrocardiol
, vol.22
, pp. 1-15
-
-
Chen, C.Y.1
Chiang, B.N.2
Macfarlane, P.W.3
-
65
-
-
0034931553
-
New normal limits for the paediatric electrocardiogram
-
Rijnbeek P.R., Witsenburg M., Schrama E., Hess J., and Kors J.A. New normal limits for the paediatric electrocardiogram. Eur Heart J 22 (2001) 702-711
-
(2001)
Eur Heart J
, vol.22
, pp. 702-711
-
-
Rijnbeek, P.R.1
Witsenburg, M.2
Schrama, E.3
Hess, J.4
Kors, J.A.5
-
66
-
-
0037211995
-
Normal limits of the electrocardiogram in Chinese subjects
-
Wu J., Kors J.A., Rijnbeek P.R., van Herpen G., Lu Z., and Xu C. Normal limits of the electrocardiogram in Chinese subjects. Int J Cardiol 87 (2003) 37-51
-
(2003)
Int J Cardiol
, vol.87
, pp. 37-51
-
-
Wu, J.1
Kors, J.A.2
Rijnbeek, P.R.3
van Herpen, G.4
Lu, Z.5
Xu, C.6
-
67
-
-
84907111790
-
Automated electrocardiogram analysis: the state of the art
-
Bessette F., and Nguyen L. Automated electrocardiogram analysis: the state of the art. Med Inform (Lond) 14 (1989) 43-51
-
(1989)
Med Inform (Lond)
, vol.14
, pp. 43-51
-
-
Bessette, F.1
Nguyen, L.2
-
69
-
-
0032216851
-
ECG compression: evaluation of FFT, DCT, and WT performance
-
GholamHosseini H., Nazeran H., and Moran B. ECG compression: evaluation of FFT, DCT, and WT performance. Australas Phys Eng Sci Med 21 (1998) 186-192
-
(1998)
Australas Phys Eng Sci Med
, vol.21
, pp. 186-192
-
-
GholamHosseini, H.1
Nazeran, H.2
Moran, B.3
-
70
-
-
0034973891
-
A new hybrid algorithm for ECG signal compression based on the wavelet transformation of the linearly predicted error
-
Ahmeda S.M., and Abo-Zahhad M. A new hybrid algorithm for ECG signal compression based on the wavelet transformation of the linearly predicted error. Med Eng Phys 23 (2001) 117-126
-
(2001)
Med Eng Phys
, vol.23
, pp. 117-126
-
-
Ahmeda, S.M.1
Abo-Zahhad, M.2
-
71
-
-
0030152625
-
Wavelet packet-based compression of single lead ECG
-
Bradie B. Wavelet packet-based compression of single lead ECG. IEEE Trans Biomed Eng 43 (1996) 493-501
-
(1996)
IEEE Trans Biomed Eng
, vol.43
, pp. 493-501
-
-
Bradie, B.1
-
72
-
-
0030947878
-
Wavelet and wavelet packet compression of electrocardiograms
-
Hilton M.L. Wavelet and wavelet packet compression of electrocardiograms. IEEE Trans Biomed Eng 44 (1997) 394-402
-
(1997)
IEEE Trans Biomed Eng
, vol.44
, pp. 394-402
-
-
Hilton, M.L.1
-
73
-
-
0034330363
-
The weighted diagnostic distortion (WDD) measure for ECG signal compression
-
Zigel Y., Cohen A., and Katz A. The weighted diagnostic distortion (WDD) measure for ECG signal compression. IEEE Trans Biomed Eng 47 (2000) 1424-1430
-
(2000)
IEEE Trans Biomed Eng
, vol.47
, pp. 1424-1430
-
-
Zigel, Y.1
Cohen, A.2
Katz, A.3
-
74
-
-
0034975547
-
Compression of ECG signals by optimized quantization of discrete cosine transform coefficients
-
Batista L.V., Melcher E.U., and Carvalho L.C. Compression of ECG signals by optimized quantization of discrete cosine transform coefficients. Med Eng Phys 23 (2001) 127-134
-
(2001)
Med Eng Phys
, vol.23
, pp. 127-134
-
-
Batista, L.V.1
Melcher, E.U.2
Carvalho, L.C.3
-
75
-
-
0026832939
-
Data compression for storage of resting ECGs digitized at 500 samples/second
-
Reddy B.R., Christenson D.W., Rowlandson G.I., Zywietz C., Sheffield T., and Brohet C. Data compression for storage of resting ECGs digitized at 500 samples/second. Biomed Instrum Technol 26 (1992) 133-149
-
(1992)
Biomed Instrum Technol
, vol.26
, pp. 133-149
-
-
Reddy, B.R.1
Christenson, D.W.2
Rowlandson, G.I.3
Zywietz, C.4
Sheffield, T.5
Brohet, C.6
-
76
-
-
0030466737
-
Development of a new approach to serial analysis: the manufacturer's viewpoint
-
Hedstrom K., and Macfarlane P.W. Development of a new approach to serial analysis: the manufacturer's viewpoint. J Electrocardiol 29 Suppl (1996) 35-40
-
(1996)
J Electrocardiol
, vol.29
, Issue.SUPPL
, pp. 35-40
-
-
Hedstrom, K.1
Macfarlane, P.W.2
-
77
-
-
0008069497
-
Lead systems
-
Macfarlane P.W., and Lawrie T.D.V. (Eds), Pergamon Press, New York, NY
-
Macfarlane P.W. Lead systems. In: Macfarlane P.W., and Lawrie T.D.V. (Eds). Comprehensive Electrocardiology: Theory and Practice in Health and Disease (1989), Pergamon Press, New York, NY 315-352
-
(1989)
Comprehensive Electrocardiology: Theory and Practice in Health and Disease
, pp. 315-352
-
-
Macfarlane, P.W.1
-
78
-
-
0014343039
-
Skin-electrode impedance problems in electrocardiography
-
Berson A.S., and Pipberger H.V. Skin-electrode impedance problems in electrocardiography. Am Heart J 76 (1968) 514-525
-
(1968)
Am Heart J
, vol.76
, pp. 514-525
-
-
Berson, A.S.1
Pipberger, H.V.2
-
79
-
-
0017844530
-
The electrical characteristics of some commercial ECG electrodes
-
Patterson R.P. The electrical characteristics of some commercial ECG electrodes. J Electrocardiol 11 (1978) 23-26
-
(1978)
J Electrocardiol
, vol.11
, pp. 23-26
-
-
Patterson, R.P.1
-
80
-
-
0018513394
-
Time and frequency dependence of disposable ECG electrode-skin impedance
-
Olson W.H., Schmincke D.R., and Henley B.L. Time and frequency dependence of disposable ECG electrode-skin impedance. Med Instrum 13 (1979) 269-272
-
(1979)
Med Instrum
, vol.13
, pp. 269-272
-
-
Olson, W.H.1
Schmincke, D.R.2
Henley, B.L.3
-
81
-
-
0026580444
-
Evaluation of changes in standard electrocardiographic QRS waveforms recorded from activity-compatible proximal limb lead positions
-
Pahlm O., Haisty Jr. W.K., Edenbrandt L., et al. Evaluation of changes in standard electrocardiographic QRS waveforms recorded from activity-compatible proximal limb lead positions. Am J Cardiol 69 (1992) 253-257
-
(1992)
Am J Cardiol
, vol.69
, pp. 253-257
-
-
Pahlm, O.1
Haisty Jr., W.K.2
Edenbrandt, L.3
-
82
-
-
0007635547
-
Standardization of precordial leads: joint recommendations of the American Heart Association and the Cardiac Society of Great Britain and Ireland
-
Standardization of precordial leads: joint recommendations of the American Heart Association and the Cardiac Society of Great Britain and Ireland. Am Heart J 15 (1938) 107-108
-
(1938)
Am Heart J
, vol.15
, pp. 107-108
-
-
-
83
-
-
0000605288
-
Standardization of precordial leads: supplementary report
-
Standardization of precordial leads: supplementary report. Am Heart J 15 (1938) 235-239
-
(1938)
Am Heart J
, vol.15
, pp. 235-239
-
-
-
84
-
-
0029776044
-
Variability of precordial electrode placement during routine electrocardiography
-
Wenger W., and Kligfield P. Variability of precordial electrode placement during routine electrocardiography. J Electrocardiol 29 (1996) 179-184
-
(1996)
J Electrocardiol
, vol.29
, pp. 179-184
-
-
Wenger, W.1
Kligfield, P.2
-
85
-
-
0030863644
-
Effect of electrode positioning on ECG interpretation by computer
-
Schijvenaars B.J., Kors J.A., van Herpen G., Kornreich F., and van Bemmel J.H. Effect of electrode positioning on ECG interpretation by computer. J Electrocardiol 30 (1997) 247-256
-
(1997)
J Electrocardiol
, vol.30
, pp. 247-256
-
-
Schijvenaars, B.J.1
Kors, J.A.2
van Herpen, G.3
Kornreich, F.4
van Bemmel, J.H.5
-
86
-
-
0030466182
-
Use of the standard 12-lead ECG to simulate electrode displacements
-
Schijvenaars R.J., Kors J.A., van Herpen G., and van Bemmel J.H. Use of the standard 12-lead ECG to simulate electrode displacements. J Electrocardiol 29 Suppl (1996) 5-9
-
(1996)
J Electrocardiol
, vol.29
, Issue.SUPPL
, pp. 5-9
-
-
Schijvenaars, R.J.1
Kors, J.A.2
van Herpen, G.3
van Bemmel, J.H.4
-
87
-
-
0020085668
-
ECG poor R-wave progression: review and synthesis
-
Zema M.J., and Kligfield P. ECG poor R-wave progression: review and synthesis. Arch Intern Med (1982) 1145-1148
-
(1982)
Arch Intern Med
, pp. 1145-1148
-
-
Zema, M.J.1
Kligfield, P.2
-
88
-
-
1242288933
-
QS- and QR-pattern in leads V3 and V4 in the absence of myocardial infarction: electrocardiographic and vectorcardiographic study
-
Surawicz B., Van Horne R.G., Urbach J.R., and Bellet S. QS- and QR-pattern in leads V3 and V4 in the absence of myocardial infarction: electrocardiographic and vectorcardiographic study. Circulation 12 (1955) 391-405
-
(1955)
Circulation
, vol.12
, pp. 391-405
-
-
Surawicz, B.1
Van Horne, R.G.2
Urbach, J.R.3
Bellet, S.4
-
89
-
-
0018375123
-
Electrocardiographic poor R wave progression, I: correlation with the Frank vectorcardiogram
-
Zema M.J., and Kligfield P. Electrocardiographic poor R wave progression, I: correlation with the Frank vectorcardiogram. J Electrocardiol 12 (1979) 3-10
-
(1979)
J Electrocardiol
, vol.12
, pp. 3-10
-
-
Zema, M.J.1
Kligfield, P.2
-
90
-
-
0025129151
-
Day-to-day variability of voltage measurements used in electrocardiographic criteria for left ventricular hypertrophy
-
Farb A., Devereux R.B., and Kligfield P. Day-to-day variability of voltage measurements used in electrocardiographic criteria for left ventricular hypertrophy. J Am Coll Cardiol 15 (1990) 618-623
-
(1990)
J Am Coll Cardiol
, vol.15
, pp. 618-623
-
-
Farb, A.1
Devereux, R.B.2
Kligfield, P.3
-
91
-
-
33847384968
-
Precordial electrode placement in women
-
Macfarlane P.M., Colaco R., Stevens K., Reay P., Beckett C., and Aitchison T.C. Precordial electrode placement in women. Neth Heart J 11 (2003) 118-122
-
(2003)
Neth Heart J
, vol.11
, pp. 118-122
-
-
Macfarlane, P.M.1
Colaco, R.2
Stevens, K.3
Reay, P.4
Beckett, C.5
Aitchison, T.C.6
-
92
-
-
0031891476
-
A standardized procedure for locating and documenting ECG chest electrode positions: consideration of the effect of breast tissue on ECG amplitudes in women
-
Rautaharju P.M., Park L., Rautaharju F.S., and Crow R. A standardized procedure for locating and documenting ECG chest electrode positions: consideration of the effect of breast tissue on ECG amplitudes in women. J Electrocardiol 31 (1998) 17-29
-
(1998)
J Electrocardiol
, vol.31
, pp. 17-29
-
-
Rautaharju, P.M.1
Park, L.2
Rautaharju, F.S.3
Crow, R.4
-
93
-
-
0034471508
-
False positive ECG reports of anterior myocardial infarction in women
-
Colaco R., Reay P., Beckett C., Aitchison T.C., and Macfarlane P.W. False positive ECG reports of anterior myocardial infarction in women. J Electrocardiol 33 Suppl (2000) 239-244
-
(2000)
J Electrocardiol
, vol.33
, Issue.SUPPL
, pp. 239-244
-
-
Colaco, R.1
Reay, P.2
Beckett, C.3
Aitchison, T.C.4
Macfarlane, P.W.5
-
94
-
-
0001236559
-
Electrocardiograms that represent the potential variations of a single electrode
-
Wilson F.N., Johnston F.D., Macleod A.G., and Barker P.S. Electrocardiograms that represent the potential variations of a single electrode. Am Heart J 9 (1934) 447-471
-
(1934)
Am Heart J
, vol.9
, pp. 447-471
-
-
Wilson, F.N.1
Johnston, F.D.2
Macleod, A.G.3
Barker, P.S.4
-
95
-
-
0000659785
-
A simple electrocardiographic electrode of zero potential and a technic of obtaining augmented unipolar extremity leads
-
Goldberger E. A simple electrocardiographic electrode of zero potential and a technic of obtaining augmented unipolar extremity leads. Am Heart J 23 (1942) 483
-
(1942)
Am Heart J
, vol.23
, pp. 483
-
-
Goldberger, E.1
-
96
-
-
33847375503
-
The aVl, aVr and aVf leads
-
Goldberger E. The aVl, aVr and aVf leads. Am Heart J 24 (1942) 378
-
(1942)
Am Heart J
, vol.24
, pp. 378
-
-
Goldberger, E.1
-
97
-
-
0026659692
-
Improvement of automated electrocardiographic diagnosis by combination of computer interpretations of the electrocardiogram and vectorcardiogram
-
Kors J.A., van Herpen G., Willems J.L., and van Bemmel J.H. Improvement of automated electrocardiographic diagnosis by combination of computer interpretations of the electrocardiogram and vectorcardiogram. Am J Cardiol 70 (1992) 96-99
-
(1992)
Am J Cardiol
, vol.70
, pp. 96-99
-
-
Kors, J.A.1
van Herpen, G.2
Willems, J.L.3
van Bemmel, J.H.4
-
98
-
-
0020663254
-
Electrocardiographic criteria for the diagnosis of combined inferior myocardial infarction and left anterior hemiblock
-
Warner R.A., Hill N.E., Mookherjee S., and Smulyan H. Electrocardiographic criteria for the diagnosis of combined inferior myocardial infarction and left anterior hemiblock. Am J Cardiol 51 (1983) 718-722
-
(1983)
Am J Cardiol
, vol.51
, pp. 718-722
-
-
Warner, R.A.1
Hill, N.E.2
Mookherjee, S.3
Smulyan, H.4
-
99
-
-
0021194522
-
Comparison of optimal scalar electrocardiographic, orthogonal electrocardiographic and vectorcardiographic criteria for diagnosing inferior and anterior myocardial infarction
-
Hill N.E., Warner R.A., Mookherjee S., and Smulyan H. Comparison of optimal scalar electrocardiographic, orthogonal electrocardiographic and vectorcardiographic criteria for diagnosing inferior and anterior myocardial infarction. Am J Cardiol 54 (1984) 274-276
-
(1984)
Am J Cardiol
, vol.54
, pp. 274-276
-
-
Hill, N.E.1
Warner, R.A.2
Mookherjee, S.3
Smulyan, H.4
-
100
-
-
33847365277
-
Sistema de 6 ejes con aplicacion al vector AT en las hipertrofias ventriculares
-
Sodi-Pallares D., Cuellar A., and Cabrera E. Sistema de 6 ejes con aplicacion al vector AT en las hipertrofias ventriculares. Arch Inst Cardiol Mexico 14 (1944) 142-149
-
(1944)
Arch Inst Cardiol Mexico
, vol.14
, pp. 142-149
-
-
Sodi-Pallares, D.1
Cuellar, A.2
Cabrera, E.3
-
101
-
-
0025299106
-
Limb leads of the electrocardiogram: sequencing revisited
-
Dower G.E., Nazzal S.B., Pahlm O., et al. Limb leads of the electrocardiogram: sequencing revisited. Clin Cardiol 13 (1990) 346-348
-
(1990)
Clin Cardiol
, vol.13
, pp. 346-348
-
-
Dower, G.E.1
Nazzal, S.B.2
Pahlm, O.3
-
102
-
-
0031445806
-
Comparison of teaching the basic electrocardiographic concept of frontal plane QRS axis using the classical versus the orderly electrocardiogram limb lead displays
-
Pahlm U.S., O'Brien J.E., Pettersson J., et al. Comparison of teaching the basic electrocardiographic concept of frontal plane QRS axis using the classical versus the orderly electrocardiogram limb lead displays. Am Heart J 134 (1997) 1014-1018
-
(1997)
Am Heart J
, vol.134
, pp. 1014-1018
-
-
Pahlm, U.S.1
O'Brien, J.E.2
Pettersson, J.3
-
103
-
-
0028061682
-
Panoramic display of the orderly sequenced 12-lead ECG
-
Anderson S.T., Pahlm O., Selvester R.H., et al. Panoramic display of the orderly sequenced 12-lead ECG. J Electrocardiol 27 (1994) 347-352
-
(1994)
J Electrocardiol
, vol.27
, pp. 347-352
-
-
Anderson, S.T.1
Pahlm, O.2
Selvester, R.H.3
-
104
-
-
0034113217
-
Improving the ECG classification of inferior and lateral myocardial infarction by inversion of lead aVR
-
Menown I.B., and Adgey A.A. Improving the ECG classification of inferior and lateral myocardial infarction by inversion of lead aVR. Heart 83 (2000) 657-660
-
(2000)
Heart
, vol.83
, pp. 657-660
-
-
Menown, I.B.1
Adgey, A.A.2
-
105
-
-
0013879798
-
A new system of multiple-lead exercise electrocardiography
-
Mason R.E., and Likar I. A new system of multiple-lead exercise electrocardiography. Am Heart J 71 (1966) 196-205
-
(1966)
Am Heart J
, vol.71
, pp. 196-205
-
-
Mason, R.E.1
Likar, I.2
-
106
-
-
0027942739
-
Simultaneous ST-segment measurements using standard and monitoring-compatible torso limb lead placements at rest and during coronary occlusion
-
Krucoff M.W., Loeffler K.A., Haisty Jr. W.K., et al. Simultaneous ST-segment measurements using standard and monitoring-compatible torso limb lead placements at rest and during coronary occlusion. Am J Cardiol 74 (1994) 997-1001
-
(1994)
Am J Cardiol
, vol.74
, pp. 997-1001
-
-
Krucoff, M.W.1
Loeffler, K.A.2
Haisty Jr., W.K.3
-
107
-
-
0024542882
-
An accurate exercise lead system for bicycle ergometer tests
-
Edenbrandt L., Pahlm O., and Sornmo L. An accurate exercise lead system for bicycle ergometer tests. Eur Heart J 10 (1989) 268-272
-
(1989)
Eur Heart J
, vol.10
, pp. 268-272
-
-
Edenbrandt, L.1
Pahlm, O.2
Sornmo, L.3
-
108
-
-
7544238485
-
Practice standards for electrocardiographic monitoring in hospital settings: an American Heart Association scientific statement from the Councils on Cardiovascular Nursing, Clinical Cardiology, and Cardiovascular Disease in the Young.
-
[published correction appears in Circulation 2005;111:378]
-
Drew B.J., Califf R.M., Funk M., et al. Practice standards for electrocardiographic monitoring in hospital settings: an American Heart Association scientific statement from the Councils on Cardiovascular Nursing, Clinical Cardiology, and Cardiovascular Disease in the Young: endorsed by the International Society of Computerized Electrocardiology and the American Association of Critical-Care Nurses. [published correction appears in Circulation 2005;111:378]. Circulation 110 (2004) 2721-2746
-
(2004)
Circulation
, vol.110
, pp. 2721-2746
-
-
Drew, B.J.1
Califf, R.M.2
Funk, M.3
-
109
-
-
0035702705
-
Correction of ECG variations caused by body position changes and electrode placement during ST-T monitoring
-
Nelwan S.P., Meij S.H., van Dam T.B., and Kors J.A. Correction of ECG variations caused by body position changes and electrode placement during ST-T monitoring. J Electrocardiol 34 Suppl (2001) 213-216
-
(2001)
J Electrocardiol
, vol.34
, Issue.SUPPL
, pp. 213-216
-
-
Nelwan, S.P.1
Meij, S.H.2
van Dam, T.B.3
Kors, J.A.4
-
110
-
-
0018889868
-
The effect of modified limb electrode positions on electrocardiographic wave amplitudes
-
Rautaharju P.M., Prineas R.J., Crow R.S., Seale D., and Furberg C. The effect of modified limb electrode positions on electrocardiographic wave amplitudes. J Electrocardiol 13 (1980) 109-113
-
(1980)
J Electrocardiol
, vol.13
, pp. 109-113
-
-
Rautaharju, P.M.1
Prineas, R.J.2
Crow, R.S.3
Seale, D.4
Furberg, C.5
-
111
-
-
0021355565
-
A comparison of the standard 12-lead electrocardiogram to exercise electrode placements
-
Gamble P., McManus H., Jensen D., and Froelicher V. A comparison of the standard 12-lead electrocardiogram to exercise electrode placements. Chest 85 (1984) 616-622
-
(1984)
Chest
, vol.85
, pp. 616-622
-
-
Gamble, P.1
McManus, H.2
Jensen, D.3
Froelicher, V.4
-
112
-
-
0024580064
-
Invalidation of the resting electrocardiogram obtained via exercise electrode sites as a standard 12-lead recording
-
Sevilla D.C., Dohrmann M.L., Somelofski C.A., Wawrzynski R.P., Wagner N.B., and Wagner G.S. Invalidation of the resting electrocardiogram obtained via exercise electrode sites as a standard 12-lead recording. Am J Cardiol 63 (1989) 35-39
-
(1989)
Am J Cardiol
, vol.63
, pp. 35-39
-
-
Sevilla, D.C.1
Dohrmann, M.L.2
Somelofski, C.A.3
Wawrzynski, R.P.4
Wagner, N.B.5
Wagner, G.S.6
-
113
-
-
0024270008
-
Deriving the 12-lead electrocardiogram from four (EASI) electrodes
-
Dower G.E., Yakush A., Nazzal S.B., Jutzy R.V., and Ruiz C.E. Deriving the 12-lead electrocardiogram from four (EASI) electrodes. J Electrocardiol 21 Suppl (1988) S182-S187
-
(1988)
J Electrocardiol
, vol.21
, Issue.SUPPL
-
-
Dower, G.E.1
Yakush, A.2
Nazzal, S.B.3
Jutzy, R.V.4
Ruiz, C.E.5
-
114
-
-
0036942544
-
Improved EASI coefficients: their derivation, values, and performance
-
Feild D.Q., Feldman C.L., and Horacek B.M. Improved EASI coefficients: their derivation, values, and performance. J Electrocardiol 35 Suppl (2002) 23-33
-
(2002)
J Electrocardiol
, vol.35
, Issue.SUPPL
, pp. 23-33
-
-
Feild, D.Q.1
Feldman, C.L.2
Horacek, B.M.3
-
115
-
-
0033389498
-
Accuracy of the EASI 12-lead electrocardiogram compared to the standard 12-lead electrocardiogram for diagnosing multiple cardiac abnormalities
-
Drew B.J., Pelter M.M., Wung S.F., et al. Accuracy of the EASI 12-lead electrocardiogram compared to the standard 12-lead electrocardiogram for diagnosing multiple cardiac abnormalities. J Electrocardiol 32 Suppl (1999) 38-47
-
(1999)
J Electrocardiol
, vol.32
, Issue.SUPPL
, pp. 38-47
-
-
Drew, B.J.1
Pelter, M.M.2
Wung, S.F.3
-
116
-
-
0034473818
-
Diagnostic accuracy of derived versus standard 12-lead electrocardiograms
-
Horacek B.M., Warren J.W., Stovicek P., and Feldman C.L. Diagnostic accuracy of derived versus standard 12-lead electrocardiograms. J Electrocardiol 33 Suppl (2000) 155-160
-
(2000)
J Electrocardiol
, vol.33
, Issue.SUPPL
, pp. 155-160
-
-
Horacek, B.M.1
Warren, J.W.2
Stovicek, P.3
Feldman, C.L.4
-
117
-
-
0042320816
-
The relative accuracies of ECG precordial lead waveforms derived from EASI leads and those acquired from paramedic applied standard leads
-
Sejersten M., Pahlm O., Pettersson J., et al. The relative accuracies of ECG precordial lead waveforms derived from EASI leads and those acquired from paramedic applied standard leads. J Electrocardiol 36 (2003) 179-185
-
(2003)
J Electrocardiol
, vol.36
, pp. 179-185
-
-
Sejersten, M.1
Pahlm, O.2
Pettersson, J.3
-
118
-
-
0018069921
-
Usefulness of three additional electrocardiographic chest leads (V7, V8, and V9) in the diagnosis of acute myocardial infarction
-
Melendez L.J., Jones D.T., and Salcedo J.R. Usefulness of three additional electrocardiographic chest leads (V7, V8, and V9) in the diagnosis of acute myocardial infarction. Can Med Assoc J 119 (1978) 745-748
-
(1978)
Can Med Assoc J
, vol.119
, pp. 745-748
-
-
Melendez, L.J.1
Jones, D.T.2
Salcedo, J.R.3
-
119
-
-
0030611378
-
Value of leads V7-V9 in diagnosing posterior wall acute myocardial infarction and other causes of tall R waves in V1-V2
-
Casas R.E., Marriott H.J., and Glancy D.L. Value of leads V7-V9 in diagnosing posterior wall acute myocardial infarction and other causes of tall R waves in V1-V2. Am J Cardiol 80 (1997) 508-509
-
(1997)
Am J Cardiol
, vol.80
, pp. 508-509
-
-
Casas, R.E.1
Marriott, H.J.2
Glancy, D.L.3
-
120
-
-
0032031632
-
Significance of ST segment elevations in posterior chest leads (V7 to V9) in patients with acute inferior myocardial infarction: application for thrombolytic therapy
-
Matetzky S., Freimark D., Chouraqui P., et al. Significance of ST segment elevations in posterior chest leads (V7 to V9) in patients with acute inferior myocardial infarction: application for thrombolytic therapy. J Am Coll Cardiol 31 (1998) 506-511
-
(1998)
J Am Coll Cardiol
, vol.31
, pp. 506-511
-
-
Matetzky, S.1
Freimark, D.2
Chouraqui, P.3
-
121
-
-
0020405121
-
Detection of acute right ventricular infarction by right precordial electrocardiography
-
Croft C.H., Nicod P., Corbett J.R., et al. Detection of acute right ventricular infarction by right precordial electrocardiography. Am J Cardiol 50 (1982) 421-427
-
(1982)
Am J Cardiol
, vol.50
, pp. 421-427
-
-
Croft, C.H.1
Nicod, P.2
Corbett, J.R.3
-
122
-
-
0020531141
-
Value of electrocardiogram in diagnosing right ventricular involvement in patients with an acute inferior wall myocardial infarction
-
Braat S.H., Brugada P., de Zwaan C., Coenegracht J.M., and Wellens H.J. Value of electrocardiogram in diagnosing right ventricular involvement in patients with an acute inferior wall myocardial infarction. Br Heart J 49 (1983) 368-372
-
(1983)
Br Heart J
, vol.49
, pp. 368-372
-
-
Braat, S.H.1
Brugada, P.2
de Zwaan, C.3
Coenegracht, J.M.4
Wellens, H.J.5
-
123
-
-
0022382373
-
Electrocardiographic findings in acute right ventricular infarction: sensitivity and specificity of electrocardiographic alterations in right precordial leads V4R, V3R, V1, V2, and V3
-
Lopez-Sendon J., Coma-Canella I., Alcasena S., Seoane J., and Gamallo C. Electrocardiographic findings in acute right ventricular infarction: sensitivity and specificity of electrocardiographic alterations in right precordial leads V4R, V3R, V1, V2, and V3. J Am Coll Cardiol 6 (1985) 1273-1279
-
(1985)
J Am Coll Cardiol
, vol.6
, pp. 1273-1279
-
-
Lopez-Sendon, J.1
Coma-Canella, I.2
Alcasena, S.3
Seoane, J.4
Gamallo, C.5
-
124
-
-
0024324974
-
Clinical correlates of acute right ventricular infarction in acute inferior myocardial infarction
-
Sinha N., Ahuja R.C., Saran R.K., and Jain G.C. Clinical correlates of acute right ventricular infarction in acute inferior myocardial infarction. Int J Cardiol 24 (1989) 55-61
-
(1989)
Int J Cardiol
, vol.24
, pp. 55-61
-
-
Sinha, N.1
Ahuja, R.C.2
Saran, R.K.3
Jain, G.C.4
-
125
-
-
0031959670
-
ST-segment elevation in right precordial leads implies depressed right ventricular function after acute inferior myocardial infarction
-
[published correction appears in Am Heart J 1998;136:5]
-
Yoshino H., Udagawa H., Shimizu H., et al. ST-segment elevation in right precordial leads implies depressed right ventricular function after acute inferior myocardial infarction. [published correction appears in Am Heart J 1998;136:5]. Am Heart J 135 (1998) 689-695
-
(1998)
Am Heart J
, vol.135
, pp. 689-695
-
-
Yoshino, H.1
Udagawa, H.2
Shimizu, H.3
-
126
-
-
11544374411
-
ST segment elevation and the prediction of hospital life-threatening complications: the role of right ventricular and posterior leads
-
Zalenski R.J., Rydman R.J., Sloan E.P., et al. ST segment elevation and the prediction of hospital life-threatening complications: the role of right ventricular and posterior leads. J Electrocardiol 31 Suppl (1998) 164-171
-
(1998)
J Electrocardiol
, vol.31
, Issue.SUPPL
, pp. 164-171
-
-
Zalenski, R.J.1
Rydman, R.J.2
Sloan, E.P.3
-
127
-
-
0033369451
-
Are additional right precordial and left posterior ECG leads useful for the diagnosis of right ventricular infarct and posterior infarct?. Also a plea for the revival of vectorcardiography
-
van Herpen G., Kors J.A., and Schijvenaars B.J. Are additional right precordial and left posterior ECG leads useful for the diagnosis of right ventricular infarct and posterior infarct?. Also a plea for the revival of vectorcardiography. J Electrocardiol 32 Suppl (1999) 51-54
-
(1999)
J Electrocardiol
, vol.32
, Issue.SUPPL
, pp. 51-54
-
-
van Herpen, G.1
Kors, J.A.2
Schijvenaars, B.J.3
-
128
-
-
0035149565
-
Does routine use of the 15-lead ECG improve the diagnosis of acute myocardial infarction in patients with chest pain?
-
Rosengarten P., Kelly A.M., and Dixon D. Does routine use of the 15-lead ECG improve the diagnosis of acute myocardial infarction in patients with chest pain?. Emerg Med (Fremantle) 13 (2001) 190-193
-
(2001)
Emerg Med (Fremantle)
, vol.13
, pp. 190-193
-
-
Rosengarten, P.1
Kelly, A.M.2
Dixon, D.3
-
129
-
-
0036788546
-
ACC/AHA guideline update for the management of patients with unstable angina and non-ST-segment elevation myocardial infarction-2002: summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on the Management of Patients With Unstable Angina)
-
Braunwald E., Antman E.M., Beasley J.W., et al. ACC/AHA guideline update for the management of patients with unstable angina and non-ST-segment elevation myocardial infarction-2002: summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on the Management of Patients With Unstable Angina). Circulation (2002) 1893-1900
-
(2002)
Circulation
, pp. 1893-1900
-
-
Braunwald, E.1
Antman, E.M.2
Beasley, J.W.3
-
130
-
-
0034177371
-
Electrocardiographic patterns in posterior chest leads (V7, V8, V9) in normal subjects
-
Chia B.L., Tan H.C., Yip J.W., and Ang T.L. Electrocardiographic patterns in posterior chest leads (V7, V8, V9) in normal subjects. Am J Cardiol 85 (2000) 911-912
-
(2000)
Am J Cardiol
, vol.85
, pp. 911-912
-
-
Chia, B.L.1
Tan, H.C.2
Yip, J.W.3
Ang, T.L.4
-
131
-
-
0032796524
-
Prevalence and outcome of ST-segment elevation in posterior electrocardiographic leads during acute myocardial infarction
-
Oraii S., Maleki M., Tavakolian A.A., Eftekharzadeh M., Kamangar F., and Mirhaji P. Prevalence and outcome of ST-segment elevation in posterior electrocardiographic leads during acute myocardial infarction. J Electrocardiol 32 (1999) 275-278
-
(1999)
J Electrocardiol
, vol.32
, pp. 275-278
-
-
Oraii, S.1
Maleki, M.2
Tavakolian, A.A.3
Eftekharzadeh, M.4
Kamangar, F.5
Mirhaji, P.6
-
132
-
-
0035304457
-
Use of the sinus P wave in diagnosing electrocardiographic limb lead misplacement not involving the right leg (ground) lead
-
Ho K.K., and Ho S.K. Use of the sinus P wave in diagnosing electrocardiographic limb lead misplacement not involving the right leg (ground) lead. J Electrocardiol 34 (2001) 161-171
-
(2001)
J Electrocardiol
, vol.34
, pp. 161-171
-
-
Ho, K.K.1
Ho, S.K.2
-
133
-
-
0028940203
-
Artificial neural networks for recognition of electrocardiographic lead reversal
-
Heden B., Ohlsson M., Edenbrandt L., Rittner R., Pahlm O., and Peterson C. Artificial neural networks for recognition of electrocardiographic lead reversal. Am J Cardiol 75 (1995) 929-933
-
(1995)
Am J Cardiol
, vol.75
, pp. 929-933
-
-
Heden, B.1
Ohlsson, M.2
Edenbrandt, L.3
Rittner, R.4
Pahlm, O.5
Peterson, C.6
-
134
-
-
0030239023
-
Detection of frequently overlooked electrocardiographic lead reversals using artificial neural networks
-
Heden B., Ohlsson M., Holst H., et al. Detection of frequently overlooked electrocardiographic lead reversals using artificial neural networks. Am J Cardiol 78 (1996) 600-604
-
(1996)
Am J Cardiol
, vol.78
, pp. 600-604
-
-
Heden, B.1
Ohlsson, M.2
Holst, H.3
-
135
-
-
0032533758
-
Recognition of lead reversals in pediatric electrocardiograms
-
Edenbrandt L., and Rittner R. Recognition of lead reversals in pediatric electrocardiograms. Am J Cardiol 82 (1998) 1290-1292
-
(1998)
Am J Cardiol
, vol.82
, pp. 1290-1292
-
-
Edenbrandt, L.1
Rittner, R.2
-
136
-
-
0035880658
-
Accurate automatic detection of electrode interchange in the electrocardiogram
-
Kors J.A., and van Herpen G. Accurate automatic detection of electrode interchange in the electrocardiogram. Am J Cardiol 88 (2001) 396-399
-
(2001)
Am J Cardiol
, vol.88
, pp. 396-399
-
-
Kors, J.A.1
van Herpen, G.2
-
137
-
-
0035189739
-
Electrocardiographic lead reversal
-
Heden B. Electrocardiographic lead reversal. Am J Cardiol 87 (2001) 126-127
-
(2001)
Am J Cardiol
, vol.87
, pp. 126-127
-
-
Heden, B.1
-
138
-
-
0030711702
-
Recognition of electrocardiographic left arm/left leg lead reversal
-
Abdollah H., and Milliken J.A. Recognition of electrocardiographic left arm/left leg lead reversal. Am J Cardiol 80 (1997) 1247-1249
-
(1997)
Am J Cardiol
, vol.80
, pp. 1247-1249
-
-
Abdollah, H.1
Milliken, J.A.2
-
139
-
-
0027197754
-
Recognition of electrocardiographic lead misplacements
-
Peberdy M.A., and Ornato J.P. Recognition of electrocardiographic lead misplacements. Am J Emerg Med 11 (1993) 403-405
-
(1993)
Am J Emerg Med
, vol.11
, pp. 403-405
-
-
Peberdy, M.A.1
Ornato, J.P.2
-
140
-
-
0027225563
-
Recognition of electrocardiographic electrode misplacements involving the ground (right leg) electrode
-
Haisty Jr. W.K., Pahlm O., Edenbrandt L., and Newman K. Recognition of electrocardiographic electrode misplacements involving the ground (right leg) electrode. Am J Cardiol 71 (1993) 1490-1495
-
(1993)
Am J Cardiol
, vol.71
, pp. 1490-1495
-
-
Haisty Jr., W.K.1
Pahlm, O.2
Edenbrandt, L.3
Newman, K.4
-
141
-
-
0021919080
-
Electrocardiographic patterns resulting from improper connections of the right leg (ground) cable
-
Castellanos A., Saoudi N.C., Schwartz A., and Sodi-Pallares D. Electrocardiographic patterns resulting from improper connections of the right leg (ground) cable. Pacing Clin Electrophysiol 8 (1985) 364-368
-
(1985)
Pacing Clin Electrophysiol
, vol.8
, pp. 364-368
-
-
Castellanos, A.1
Saoudi, N.C.2
Schwartz, A.3
Sodi-Pallares, D.4
-
142
-
-
0025858633
-
Variability of electrocardiographic precordial lead placement: a method to improve accuracy and reliability
-
Herman M.V., Ingram D.A., Levy J.A., Cook J.R., and Athans R.J. Variability of electrocardiographic precordial lead placement: a method to improve accuracy and reliability. Clin Cardiol 14 (1991) 469-476
-
(1991)
Clin Cardiol
, vol.14
, pp. 469-476
-
-
Herman, M.V.1
Ingram, D.A.2
Levy, J.A.3
Cook, J.R.4
Athans, R.J.5
-
143
-
-
0004948618
-
A method for the accurate placement of chest electrodes in the taking of serial electrocardiographic tracings
-
Kerwin A.J., McLean R., and Tegelaar H. A method for the accurate placement of chest electrodes in the taking of serial electrocardiographic tracings. Can Med Assoc J 82 (1960) 258-261
-
(1960)
Can Med Assoc J
, vol.82
, pp. 258-261
-
-
Kerwin, A.J.1
McLean, R.2
Tegelaar, H.3
-
144
-
-
0027096172
-
Reproducibility of electrocardiographic criteria for left ventricular hypertrophy in hypertensive patients in general practice
-
Van Den Hoogen J.P., Mol W.H., Kowsoleea A., Van Ree J.W., Thien T., and Van Weel C. Reproducibility of electrocardiographic criteria for left ventricular hypertrophy in hypertensive patients in general practice. Eur Heart J 13 (1992) 1606-1610
-
(1992)
Eur Heart J
, vol.13
, pp. 1606-1610
-
-
Van Den Hoogen, J.P.1
Mol, W.H.2
Kowsoleea, A.3
Van Ree, J.W.4
Thien, T.5
Van Weel, C.6
-
145
-
-
0031759384
-
Reproducibility of computerized ECG measurements and coding in a nonhospitalized elderly population
-
de Bruyne M.C., Kors J.A., Visentin S., et al. Reproducibility of computerized ECG measurements and coding in a nonhospitalized elderly population. J Electrocardiol 31 (1998) 189-195
-
(1998)
J Electrocardiol
, vol.31
, pp. 189-195
-
-
de Bruyne, M.C.1
Kors, J.A.2
Visentin, S.3
-
146
-
-
0000111057
-
The corrected orthogonal electrocardiogram and vectorcardiogram in 510 normal men (Frank lead system)
-
Draper H.W., Peffer C.J., Stallmann F.W., Littmann D., and Pipberger H.V. The corrected orthogonal electrocardiogram and vectorcardiogram in 510 normal men (Frank lead system). Circulation 30 (1964) 853-864
-
(1964)
Circulation
, vol.30
, pp. 853-864
-
-
Draper, H.W.1
Peffer, C.J.2
Stallmann, F.W.3
Littmann, D.4
Pipberger, H.V.5
-
147
-
-
0000291928
-
Preparation of electrocardiographic data for analysis by digital electronic computer
-
Pipberger H.V., Freis E.D., Taback L., and Mason H.L. Preparation of electrocardiographic data for analysis by digital electronic computer. Circulation 21 (1960) 413-418
-
(1960)
Circulation
, vol.21
, pp. 413-418
-
-
Pipberger, H.V.1
Freis, E.D.2
Taback, L.3
Mason, H.L.4
-
148
-
-
84921082373
-
Computer analysis of electrocardiographic measurements
-
Rikli A.E., Tolles W.E., Steinberg C.A., et al. Computer analysis of electrocardiographic measurements. Circulation 24 (1961) 643-649
-
(1961)
Circulation
, vol.24
, pp. 643-649
-
-
Rikli, A.E.1
Tolles, W.E.2
Steinberg, C.A.3
-
149
-
-
33847354691
-
Automatic analysis of the P-QRS-T complex of the electrocardiogram by digital computer
-
Pipberger H.V., Stallman F.W., and Berson A.S. Automatic analysis of the P-QRS-T complex of the electrocardiogram by digital computer. Ann Intern Med 57 (1962) 776-787
-
(1962)
Ann Intern Med
, vol.57
, pp. 776-787
-
-
Pipberger, H.V.1
Stallman, F.W.2
Berson, A.S.3
-
150
-
-
3643052396
-
Computer extraction of electrocardiographic parameters
-
Caceres C.A., Steinberg C.A., Abraham S., et al. Computer extraction of electrocardiographic parameters. Circulation 25 (1962) 356-362
-
(1962)
Circulation
, vol.25
, pp. 356-362
-
-
Caceres, C.A.1
Steinberg, C.A.2
Abraham, S.3
-
151
-
-
0014246277
-
Computer diagnosis of electrocardiograms, II: a computer program for EKG measurements
-
Bonner R.E., and Schwetman H.D. Computer diagnosis of electrocardiograms, II: a computer program for EKG measurements. Comput Biomed Res 1 (1968) 366-386
-
(1968)
Comput Biomed Res
, vol.1
, pp. 366-386
-
-
Bonner, R.E.1
Schwetman, H.D.2
-
152
-
-
33751214014
-
Computer analysis of the ECG in clinical practice
-
Manning G.W., and Ahuja S.P. (Eds), Charles C Thomas, Springfield, IL
-
Smith R.E., and Hyde F.M. Computer analysis of the ECG in clinical practice. In: Manning G.W., and Ahuja S.P. (Eds). Electrical Activity of the Heart (1969), Charles C Thomas, Springfield, IL 305
-
(1969)
Electrical Activity of the Heart
, pp. 305
-
-
Smith, R.E.1
Hyde, F.M.2
-
157
-
-
0014300851
-
A point-score system for the ECG diagnosis of left ventricular hypertrophy
-
Romhilt D.W., and Estes Jr. E.H. A point-score system for the ECG diagnosis of left ventricular hypertrophy. Am Heart J 75 (1968) 752-758
-
(1968)
Am Heart J
, vol.75
, pp. 752-758
-
-
Romhilt, D.W.1
Estes Jr., E.H.2
-
158
-
-
0031923704
-
Time-voltage QRS area of the 12-lead electrocardiogram: detection of left ventricular hypertrophy
-
Okin P.M., Roman M.J., Devereux R.B., Pickering T.G., Borer J.S., and Kligfield P. Time-voltage QRS area of the 12-lead electrocardiogram: detection of left ventricular hypertrophy. Hypertension 31 (1998) 937-942
-
(1998)
Hypertension
, vol.31
, pp. 937-942
-
-
Okin, P.M.1
Roman, M.J.2
Devereux, R.B.3
Pickering, T.G.4
Borer, J.S.5
Kligfield, P.6
-
159
-
-
0028281153
-
Diagnostic ECG classification based on neural networks
-
Bortolan G., and Willems J.L. Diagnostic ECG classification based on neural networks. J Electrocardiol 26 Suppl (1993) 75-79
-
(1993)
J Electrocardiol
, vol.26
, Issue.SUPPL
, pp. 75-79
-
-
Bortolan, G.1
Willems, J.L.2
-
160
-
-
0030273084
-
Agreement between artificial neural networks and experienced electrocardiographer on electrocardiographic diagnosis of healed myocardial infarction
-
Heden B., Ohlsson M., Rittner R., et al. Agreement between artificial neural networks and experienced electrocardiographer on electrocardiographic diagnosis of healed myocardial infarction. J Am Coll Cardiol 28 (1996) 1012-1016
-
(1996)
J Am Coll Cardiol
, vol.28
, pp. 1012-1016
-
-
Heden, B.1
Ohlsson, M.2
Rittner, R.3
-
161
-
-
0031925145
-
NHLBI workshop on the utilization of ECG databases: preservation and use of existing ECG databases and development of future resources
-
Norman J.E., Bailey J.J., Berson A.S., et al. NHLBI workshop on the utilization of ECG databases: preservation and use of existing ECG databases and development of future resources. J Electrocardiol 31 (1998) 83-89
-
(1998)
J Electrocardiol
, vol.31
, pp. 83-89
-
-
Norman, J.E.1
Bailey, J.J.2
Berson, A.S.3
-
162
-
-
0036934740
-
Improved electrocardiographic detection of left ventricular hypertrophy
-
Warner R.A., Ariel Y., Gasperina M.D., and Okin P.M. Improved electrocardiographic detection of left ventricular hypertrophy. J Electrocardiol 35 Suppl (2002) 111-115
-
(2002)
J Electrocardiol
, vol.35
, Issue.SUPPL
, pp. 111-115
-
-
Warner, R.A.1
Ariel, Y.2
Gasperina, M.D.3
Okin, P.M.4
-
163
-
-
0016233858
-
A method for evaluating computer programs for electrocardiographic interpretation, I: application to the experimental IBM program of 1971
-
Bailey J.J., Itscoitz S.B., Hirshfeld Jr. J.W., Grauer L.E., and Horton M.R. A method for evaluating computer programs for electrocardiographic interpretation, I: application to the experimental IBM program of 1971. Circulation 50 (1974) 73-79
-
(1974)
Circulation
, vol.50
, pp. 73-79
-
-
Bailey, J.J.1
Itscoitz, S.B.2
Hirshfeld Jr., J.W.3
Grauer, L.E.4
Horton, M.R.5
-
164
-
-
0026410062
-
Computerized electrocardiography: an adjunct to the physician
-
Laks M.M., and Selvester R.H. Computerized electrocardiography: an adjunct to the physician. N Engl J Med 325 (1991) 1803-1804
-
(1991)
N Engl J Med
, vol.325
, pp. 1803-1804
-
-
Laks, M.M.1
Selvester, R.H.2
|