메뉴 건너뛰기




Volumn 98, Issue 3, 2014, Pages 334-338

Direct comparison of spectral-domain and swept-source OCT in the measurement of choroidal thickness in normal eyes

Author keywords

[No Author keywords available]

Indexed keywords

ANATOMY; CHOROID; IMAGING; MACULA;

EID: 84894033667     PISSN: 00071161     EISSN: 14682079     Source Type: Journal    
DOI: 10.1136/bjophthalmol-2013-303904     Document Type: Article
Times cited : (177)

References (25)
  • 1
    • 79956015900 scopus 로고    scopus 로고
    • Optical coherence tomography: History, current status, and laboratory work
    • Gabriele ML, Wollstein G, Ishikawa H, et al. Optical coherence tomography: history, current status, and laboratory work. Invest Ophthalmol Vis Sci 2011;52: 2425-36.
    • (2011) Invest Ophthalmol Vis Sci , vol.52 , pp. 2425-2436
    • Gabriele, M.L.1    Wollstein, G.2    Ishikawa, H.3
  • 3
    • 0015604413 scopus 로고
    • Optical constants of water in the 200-nm to 200-micron wavelength region
    • Hale GM, Querry MR. Optical constants of water in the 200-nm to 200-micron wavelength region. Appl Opt 1973;12: 555-63.
    • (1973) Appl Opt , vol.12 , pp. 555-563
    • Hale, G.M.1    Querry, M.R.2
  • 4
    • 51849121006 scopus 로고    scopus 로고
    • Enhanced depth imaging spectral-domain optical coherence tomography
    • Spaide RF, Koizumi H, Pozzoni MC. Enhanced depth imaging spectral-domain optical coherence tomography. Am J Ophthalmol 2008;146: 496-500.
    • (2008) Am J Ophthalmol , vol.146 , pp. 496-500
    • Spaide, R.F.1    Koizumi, H.2    Pozzoni, M.C.3
  • 5
    • 73349109845 scopus 로고    scopus 로고
    • Enhanced depth imaging optical coherence tomography of the choroid in central serous chorioretinopathy
    • Imamura Y, Fujiwara T, Margolis R, et al. Enhanced depth imaging optical coherence tomography of the choroid in central serous chorioretinopathy. Retina 2009;29: 1469-73.
    • (2009) Retina , vol.29 , pp. 1469-1473
    • Imamura, Y.1    Fujiwara, T.2    Margolis, R.3
  • 6
    • 80053323209 scopus 로고    scopus 로고
    • Analysis of choroidal thickness in age-related macular degeneration using spectral-domain optical coherence tomography
    • Manjunath V, Goren J, Fujimoto JG, et al. Analysis of choroidal thickness in age-related macular degeneration using spectral-domain optical coherence tomography. Am J Ophthalmol 2011;152: 663-8.
    • (2011) Am J Ophthalmol , vol.152 , pp. 663-668
    • Manjunath, V.1    Goren, J.2    Fujimoto, J.G.3
  • 7
    • 69049108634 scopus 로고    scopus 로고
    • Enhanced depth imaging optical coherence tomography of the choroid in highly myopic eyes
    • Fujiwara T, Imamura Y, Margolis R, et al. Enhanced depth imaging optical coherence tomography of the choroid in highly myopic eyes. Am J Ophthalmol 2009;148: 445-50.
    • (2009) Am J Ophthalmol , vol.148 , pp. 445-450
    • Fujiwara, T.1    Imamura, Y.2    Margolis, R.3
  • 8
    • 45249124238 scopus 로고    scopus 로고
    • Full-range, high-speed, high-resolution 1 micron spectral-domain optical coherence tomography using bm-scan for volumetric imaging of the human posterior eye
    • Makita S, Fabritius T, Yasuno Y. Full-range, high-speed, high-resolution 1 micron spectral-domain optical coherence tomography using BM-scan for volumetric imaging of the human posterior eye. Opt Express 2008;16: 8406-20.
    • (2008) Opt Express , vol.16 , pp. 8406-8420
    • Makita, S.1    Fabritius, T.2    Yasuno, Y.3
  • 9
    • 77957013968 scopus 로고    scopus 로고
    • Ultrahigh speed 1050 nm swept source/ fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second
    • Potsaid B, Baumann B, Huang D, et al. Ultrahigh speed 1050 nm swept source/ Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second. Opt Express 2010;18: 20029-48.
    • (2010) Opt Express , vol.18 , pp. 20029-20048
    • Potsaid, B.1    Baumann, B.2    Huang, D.3
  • 10
    • 80755132278 scopus 로고    scopus 로고
    • Choroidal thickness measurement in healthy japanese subjects by three-dimensional high-penetration optical coherence tomography
    • Agawa T, Miura M, Ikuno Y, et al. Choroidal thickness measurement in healthy Japanese subjects by three-dimensional high-penetration optical coherence tomography. Graefes Arch Clin Exp Ophthalmol 2011;249: 1485-92.
    • (2011) Graefes Arch Clin Exp Ophthalmol , vol.249 , pp. 1485-1492
    • Agawa, T.1    Miura, M.2    Ikuno, Y.3
  • 12
    • 84865835346 scopus 로고    scopus 로고
    • Morphologic analysis in pathologic myopia using high-penetration optical coherence tomography
    • Maruko I, Iida T, Sugano Y, et al. Morphologic analysis in pathologic myopia using high-penetration optical coherence tomography. Invest Ophthalmol Vis Sci 2012;53: 3834-38.
    • (2012) Invest Ophthalmol Vis Sci , vol.53 , pp. 3834-3838
    • Maruko, I.1    Iida, T.2    Sugano, Y.3
  • 13
    • 84864460801 scopus 로고    scopus 로고
    • Assessment of macular choroidal thickness by optical coherence tomography and angiographic changes in central serous chorioretinopathy
    • Jirarattanasopa P, Ooto S, Tsujikawa A, et al. Assessment of macular choroidal thickness by optical coherence tomography and angiographic changes in central serous chorioretinopathy. Ophthalmology 2012;119: 1666-78.
    • (2012) Ophthalmology , vol.119 , pp. 1666-1678
    • Jirarattanasopa, P.1    Ooto, S.2    Tsujikawa, A.3
  • 14
    • 84882250717 scopus 로고    scopus 로고
    • Enhanced depth imaging optical coherence tomography of the choroid in central retinal vein occlusion
    • Tsuiki E, Suzuma K, Ueki R, et al. Enhanced depth imaging optical coherence tomography of the choroid in central retinal vein occlusion. Am J Ophthalmol 2013;156: 543-7.
    • (2013) Am J Ophthalmol , vol.156 , pp. 543-547
    • Tsuiki, E.1    Suzuma, K.2    Ueki, R.3
  • 15
    • 80053325774 scopus 로고    scopus 로고
    • Reproducibility of retinal and choroidal thickness measurements in enhanced depth imaging and high-penetration optical coherence tomography
    • Ikuno Y, Maruko I, Yasuno Y, et al. Reproducibility of retinal and choroidal thickness measurements in enhanced depth imaging and high-penetration optical coherence tomography. Invest Ophthalmol Vis Sci 2011;52: 5536-40.
    • (2011) Invest Ophthalmol Vis Sci , vol.52 , pp. 5536-5540
    • Ikuno, Y.1    Maruko, I.2    Yasuno, Y.3
  • 16
    • 77955500358 scopus 로고    scopus 로고
    • Macular thickness interoperator and intraoperator reproducibility in healthy eyes using 7 optical coherence tomography instruments
    • e191
    • Pierro L, Giatsidis SM, Mantovani E, et al. Macular thickness interoperator and intraoperator reproducibility in healthy eyes using 7 optical coherence tomography instruments. Am J Ophthalmol 2010;150:199-204 e191.
    • (2010) Am J Ophthalmol , vol.150 , pp. 199-204
    • Pierro, L.1    Giatsidis, S.M.2    Mantovani, E.3
  • 17
    • 78349310288 scopus 로고    scopus 로고
    • Reproducibility-repeatability of choroidal thickness calculation using optical coherence tomography
    • Benavente-Perez A, Hosking SL, Logan NS, et al. Reproducibility- repeatability of choroidal thickness calculation using optical coherence tomography. Optom Vis Sci 2010;87: 867-72.
    • (2010) Optom Vis Sci , vol.87 , pp. 867-872
    • Benavente-Perez, A.1    Hosking, S.L.2    Logan, N.S.3
  • 18
    • 79955986230 scopus 로고    scopus 로고
    • Repeatability of manual subfoveal choroidal thickness measurements in healthy subjects using the technique of enhanced depth imaging optical coherence tomography
    • Rahman W, Chen FK, Yeoh J, et al. Repeatability of manual subfoveal choroidal thickness measurements in healthy subjects using the technique of enhanced depth imaging optical coherence tomography. Invest Ophthalmol Vis Sci 2011;52: 2267-71.
    • (2011) Invest Ophthalmol Vis Sci , vol.52 , pp. 2267-2271
    • Rahman, W.1    Chen, F.K.2    Yeoh, J.3
  • 19
    • 84855300621 scopus 로고    scopus 로고
    • Reproducibility of choroidal thickness measurements across three spectral domain optical coherence tomography systems
    • Branchini L, Regatieri CV, Flores-Moreno I, et al. Reproducibility of choroidal thickness measurements across three spectral domain optical coherence tomography systems. Ophthalmology 2012;119: 119-23.
    • (2012) Ophthalmology , vol.119 , pp. 119-123
    • Branchini, L.1    Regatieri, C.V.2    Flores-Moreno, I.3
  • 20
    • 84857841819 scopus 로고    scopus 로고
    • Repeatability and reproducibility of subfoveal choroidal thickness in normal eyes of japanese using different sd-oct devices
    • Yamashita T, Shirasawa M, Arimura N, et al. Repeatability and reproducibility of subfoveal choroidal thickness in normal eyes of Japanese using different SD-OCT devices. Invest Ophthalmol Vis Sci 2012;53: 1102-7.
    • (2012) Invest Ophthalmol Vis Sci , vol.53 , pp. 1102-1107
    • Yamashita, T.1    Shirasawa, M.2    Arimura, N.3
  • 21
    • 84874730832 scopus 로고    scopus 로고
    • Reproducibility of subfoveal choroidal thickness measurements with enhanced depth imaging by spectral-domain optical coherence tomography
    • Shao L, Xu L, Chen CX, et al. Reproducibility of subfoveal choroidal thickness measurements with enhanced depth imaging by spectral-domain optical coherence tomography. Invest Ophthalmol Vis Sci 2013;54: 230-3.
    • (2013) Invest Ophthalmol Vis Sci , vol.54 , pp. 230-233
    • Shao, L.1    Xu, L.2    Chen, C.X.3
  • 22
    • 77956063976 scopus 로고    scopus 로고
    • Choroidal thickness in normal eyes measured using cirrus hd optical coherence tomography
    • e321
    • Manjunath V, Taha M, Fujimoto JG, et al. Choroidal thickness in normal eyes measured using Cirrus HD optical coherence tomography. Am J Ophthalmol 2010;150:325-9 e321.
    • (2010) Am J Ophthalmol , vol.150 , pp. 325-329
    • Manjunath, V.1    Taha, M.2    Fujimoto, J.G.3
  • 23
    • 84872030190 scopus 로고    scopus 로고
    • Subfoveal choroidal thickness: The beijing eye study
    • Wei WB, Xu L, Jonas JB, et al. Subfoveal choroidal thickness: the Beijing Eye Study. Ophthalmology 2013;120: 175-80.
    • (2013) Ophthalmology , vol.120 , pp. 175-180
    • Wei, W.B.1    Xu, L.2    Jonas, J.B.3
  • 24
    • 84872018115 scopus 로고    scopus 로고
    • Measurement of choroidal thickness in normal eyes using 3d oct-1000 spectral domain optical coherence tomography
    • Shin JW, Shin YU, Cho HY, et al. Measurement of choroidal thickness in normal eyes using 3D OCT-1000 spectral domain optical coherence tomography. Korean J Ophthalmol 2012;26: 255-9.
    • (2012) Korean J Ophthalmol , vol.26 , pp. 255-259
    • Shin, J.W.1    Shin, Y.U.2    Cho, H.Y.3
  • 25
    • 64449085730 scopus 로고    scopus 로고
    • A pilot study of enhanced depth imaging optical coherence tomography of the choroid in normal eyes
    • Margolis R, Spaide RF. A pilot study of enhanced depth imaging optical coherence tomography of the choroid in normal eyes. Am J Ophthalmol 2009;147: 811-15.
    • (2009) Am J Ophthalmol , vol.147 , pp. 811-815
    • Margolis, R.1    Spaide, R.F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.