메뉴 건너뛰기




Volumn 83, Issue 3, 2014, Pages 405-411

First report of a novel polymer-free dual-drug eluting stent in de novo coronary artery disease: Results of the first in human BICARE trial

Author keywords

drug eluting stent; first in human trial; polymer; probucol; sirolimus

Indexed keywords

DRUG-ELUTING STENT; FIRST IN HUMAN TRIAL; POLYMER; PROBUCOL; SIROLIMUS;

EID: 84893780328     PISSN: 15221946     EISSN: 1522726X     Source Type: Journal    
DOI: 10.1002/ccd.25129     Document Type: Article
Times cited : (15)

References (26)
  • 1
    • 33847167065 scopus 로고    scopus 로고
    • Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: Data from a large two-institutional cohort study
    • et al.
    • Daemen J, Wenaweser P, Tsuchida K, et al. Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: Data from a large two-institutional cohort study. Lancet 2007; 369: 667-678.
    • (2007) Lancet , vol.369 , pp. 667-678
    • Daemen, J.1    Wenaweser, P.2    Tsuchida, K.3
  • 2
    • 84857053550 scopus 로고    scopus 로고
    • Very late stent thrombosis and late target lesion revascularization after sirolimus-eluting stent implantation: Five-year outcome of the j-Cypher Registry
    • et al.; j-Cypher Registry Investigators.
    • Kimura T, Morimoto T, Nakagawa Y, et al.; j-Cypher Registry Investigators. Very late stent thrombosis and late target lesion revascularization after sirolimus-eluting stent implantation: five-year outcome of the j-Cypher Registry. Circulation 2012; 125: 584-591.
    • (2012) Circulation , vol.125 , pp. 584-591
    • Kimura, T.1    Morimoto, T.2    Nakagawa, Y.3
  • 3
    • 77952744608 scopus 로고    scopus 로고
    • 2-year clinical and angiographic outcomes from a randomized trial of polymer-free dual drug-eluting stents versus polymer-based Cypher and Endeavor drug-eluting stents
    • et al.; ISAR-TEST-2 Investigators.
    • Byrne RA, Kastrati A, Tiroch K, et al.; ISAR-TEST-2 Investigators. 2-year clinical and angiographic outcomes from a randomized trial of polymer-free dual drug-eluting stents versus polymer-based Cypher and Endeavor drug-eluting stents. J Am Coll Cardiol 2010; 55: 2536-2543.
    • (2010) J Am Coll Cardiol , vol.55 , pp. 2536-2543
    • Byrne, R.A.1    Kastrati, A.2    Tiroch, K.3
  • 4
    • 68249122647 scopus 로고    scopus 로고
    • Correlation of intravascular ultrasound findings with histopathological analysis of thrombus aspirates in patients with very late drug-eluting stent thrombosis
    • et al.
    • Cook S, Ladich E, Nakazawa G, et al. Correlation of intravascular ultrasound findings with histopathological analysis of thrombus aspirates in patients with very late drug-eluting stent thrombosis. Circulation 2009; 120: 391-399.
    • (2009) Circulation , vol.120 , pp. 391-399
    • Cook, S.1    Ladich, E.2    Nakazawa, G.3
  • 5
    • 84855605824 scopus 로고    scopus 로고
    • Examination of the in vivo mechanisms of late drug-eluting stent thrombosis
    • et al.
    • Guagliumi G, Sirbu V, Musumeci G, et al. Examination of the in vivo mechanisms of late drug-eluting stent thrombosis. J Am Coll Cardiol Intv 2012; 5: 12-20.
    • (2012) J Am Coll Cardiol Intv , vol.5 , pp. 12-20
    • Guagliumi, G.1    Sirbu, V.2    Musumeci, G.3
  • 6
    • 79952414020 scopus 로고    scopus 로고
    • The pathology of neoatherosclerosis in human coronary implants: Bare-metal and drug-eluting stents
    • et al.
    • Nakazawa G, Otsuka F, Nakano M, et al. The pathology of neoatherosclerosis in human coronary implants: bare-metal and drug-eluting stents. J Am Coll Cardiol 2011; 57: 1314-1322.
    • (2011) J Am Coll Cardiol , vol.57 , pp. 1314-1322
    • Nakazawa, G.1    Otsuka, F.2    Nakano, M.3
  • 7
    • 0029761378 scopus 로고    scopus 로고
    • Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries
    • et al.
    • van der Giessen WJ, Lincoff AM, Schwartz RS, et al. Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries. Circulation 1996; 94: 1690-1697.
    • (1996) Circulation , vol.94 , pp. 1690-1697
    • Van Der Giessen, W.J.1    Lincoff, A.M.2    Schwartz, R.S.3
  • 8
    • 33847259689 scopus 로고    scopus 로고
    • Drug-eluting stent and coronary thrombosis: Biological mechanisms and clinical implications
    • et al.
    • Lüscher TF, Steffel J, Eberli FR, et al. Drug-eluting stent and coronary thrombosis: biological mechanisms and clinical implications. Circulation 2007; 115: 1051-1058.
    • (2007) Circulation , vol.115 , pp. 1051-1058
    • Lüscher, T.F.1    Steffel, J.2    Eberli, F.R.3
  • 9
    • 34250835092 scopus 로고    scopus 로고
    • Vascular responses to drug eluting stents: Importance of delayed healing
    • et al.
    • Finn AV, Nakazawa G, Joner M, et al. Vascular responses to drug eluting stents: importance of delayed healing. Arterioscler Thromb Vasc Biol 2007; 27: 1500-1510.
    • (2007) Arterioscler Thromb Vasc Biol , vol.27 , pp. 1500-1510
    • Finn, A.V.1    Nakazawa, G.2    Joner, M.3
  • 10
    • 33745233024 scopus 로고    scopus 로고
    • Pathology of drug-eluting stents in humans: Delayed healing and late thrombotic risk
    • et al.
    • Joner M, Finn AV, Farb A, et al. Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. J Am Coll Cardiol 2006; 48: 193-202.
    • (2006) J Am Coll Cardiol , vol.48 , pp. 193-202
    • Joner, M.1    Finn, A.V.2    Farb, A.3
  • 11
    • 10744229988 scopus 로고    scopus 로고
    • Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: Should we be cautious?
    • et al.
    • Virmani R, Guagliumi G, Farb A, et al. Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious? Circulation 2004; 109: 701-705.
    • (2004) Circulation , vol.109 , pp. 701-705
    • Virmani, R.1    Guagliumi, G.2    Farb, A.3
  • 12
    • 78751623656 scopus 로고    scopus 로고
    • Coronary responses and differential mechanisms of late stent thrombosis attributed to first-generation sirolimus- and paclitaxel-eluting stents
    • Nakazawa G, Finn AV, Vorpahl M, Ladich ER, Kolodgie FD, Virmani R,. Coronary responses and differential mechanisms of late stent thrombosis attributed to first-generation sirolimus- and paclitaxel-eluting stents. J Am Coll Cardiol 2011; 57; 390-398.
    • (2011) J Am Coll Cardiol , vol.57 , pp. 390-398
    • Nakazawa, G.1    Finn, A.V.2    Vorpahl, M.3    Ladich, E.R.4    Kolodgie, F.D.5    Virmani, R.6
  • 13
    • 0025542168 scopus 로고
    • Coronary morphologic and clinical determinants of procedural outcome with angioplasty for multivessel coronary disease: Implications for patient selection
    • et al.
    • Ellis SG, Vandormael MG, Cowley MJ, et al. Coronary morphologic and clinical determinants of procedural outcome with angioplasty for multivessel coronary disease: implications for patient selection. Circulation 1990; 82: 1193-1202.
    • (1990) Circulation , vol.82 , pp. 1193-1202
    • Ellis, S.G.1    Vandormael, M.G.2    Cowley, M.J.3
  • 14
    • 79955098400 scopus 로고    scopus 로고
    • Randomized comparison of a polymer-free sirolimus-eluting stent versus a polymer-based paclitaxel-eluting stent in patients with diabetes mellitus: The LIPSIA Yukon trial
    • et al.
    • Desch S, Schloma D, Möbius-Winkler S, et al. Randomized comparison of a polymer-free sirolimus-eluting stent versus a polymer-based paclitaxel-eluting stent in patients with diabetes mellitus: the LIPSIA Yukon trial. Cathet Cardiovasc Interv 2011; 4: 452-459.
    • (2011) Cathet Cardiovasc Interv , vol.4 , pp. 452-459
    • Desch, S.1    Schloma, D.2    Möbius-Winkler, S.3
  • 15
    • 41149176136 scopus 로고    scopus 로고
    • Comparison of a polymer-free rapamycin-eluting stent (YUKON) with a polymer-based paclitaxel-eluting stent (TAXUS) in real-world coronary artery lesions
    • Ruef J, Störger H, Schwarz F, Haase J,. Comparison of a polymer-free rapamycin-eluting stent (YUKON) with a polymer-based paclitaxel-eluting stent (TAXUS) in real-world coronary artery lesions. Cathet Cardiovasc Interv 2008; 71: 333-339.
    • (2008) Cathet Cardiovasc Interv , vol.71 , pp. 333-339
    • Ruef, J.1    Störger, H.2    Schwarz, F.3    Haase, J.4
  • 16
    • 65549135905 scopus 로고    scopus 로고
    • One-year results of the hydroxyapatite polymer-free sirolimus-eluting stent for the treatment of single de novo coronary lesions: The VESTASYNC i trial
    • et al.
    • Costa JR Jr, Abizaid A, Costa R, et al. One-year results of the hydroxyapatite polymer-free sirolimus-eluting stent for the treatment of single de novo coronary lesions: the VESTASYNC I trial. J Am Coll Cardiol Interv 2009; 2: 422-427.
    • (2009) J Am Coll Cardiol Interv , vol.2 , pp. 422-427
    • Costa, Jr.J.R.1    Abizaid, A.2    Costa, R.3
  • 17
    • 80051543813 scopus 로고    scopus 로고
    • Intracoronary Stenting and Angiographic Results: Test Efficacy of Sirolimus- and Probucol-Eluting Versus Zotarolimus- Eluting Stents (ISAR-TEST 5) Investigators. Intracoronary Stenting and Angiographic Results: Test Efficacy of Sirolimus- and Probucol-Eluting Versus Zotarolimus- Eluting Stents (ISAR-TEST 5) Investigators
    • et al.Polymer-free sirolimus- and probucol-eluting versus new generation zotarolimus-eluting stents in coronary artery disease: The Intracoronary Stenting and Angiographic Results: Test Efficacy of Sirolimus- and Probucol-Eluting versus Zotarolimus-eluting Stents (ISAR-TEST 5) trial
    • Massberg S, Byrne RA, Kastrati A, et al. Intracoronary Stenting and Angiographic Results: Test Efficacy of Sirolimus- and Probucol-Eluting Versus Zotarolimus- Eluting Stents (ISAR-TEST 5) Investigators. Intracoronary Stenting and Angiographic Results: Test Efficacy of Sirolimus- and Probucol-Eluting Versus Zotarolimus- Eluting Stents (ISAR-TEST 5) Investigators. Polymer-free sirolimus- and probucol-eluting versus new generation zotarolimus-eluting stents in coronary artery disease: the Intracoronary Stenting and Angiographic Results: Test Efficacy of Sirolimus- and Probucol-Eluting versus Zotarolimus-eluting Stents (ISAR-TEST 5) trial. Circulation 2011; 124: 624-632.
    • (2011) Circulation , vol.124 , pp. 624-632
    • Massberg, S.1    Byrne, R.A.2    Kastrati, A.3
  • 18
    • 32644453379 scopus 로고    scopus 로고
    • Sirolimus and paclitaxel on polymer-based drug-eluting stents: Similar but different
    • Wessely R, Schomig A, Kastrati A,. Sirolimus and paclitaxel on polymer-based drug-eluting stents: similar but different. J Am Coll Cardiol 2006; 47: 708-714.
    • (2006) J Am Coll Cardiol , vol.47 , pp. 708-714
    • Wessely, R.1    Schomig, A.2    Kastrati, A.3
  • 19
    • 23844482954 scopus 로고    scopus 로고
    • Sirolimus-eluting and paclitaxel-eluting stents for coronary revascularization
    • et al.
    • Windecker S, Remondino A, Eberli FR, et al. Sirolimus-eluting and paclitaxel-eluting stents for coronary revascularization. N Engl J Med 2005; 353: 653-662.
    • (2005) N Engl J Med , vol.353 , pp. 653-662
    • Windecker, S.1    Remondino, A.2    Eberli, F.R.3
  • 20
    • 80055015153 scopus 로고    scopus 로고
    • Everolimus-eluting versus sirolimus-eluting stents in patients undergoing percutaneous coronary intervention: The EXCELLENT (Efficacy of Xience/Promus Versus Cypher to Reduce Late Loss after Stenting) randomized trial
    • et al.
    • Park KW, Chae IH, Lim DS, et al. Everolimus-eluting versus sirolimus-eluting stents in patients undergoing percutaneous coronary intervention: the EXCELLENT (Efficacy of Xience/Promus Versus Cypher to Reduce Late Loss After Stenting) randomized trial. J Am Coll Cardiol 2011; 58: 1844-1854.
    • (2011) J Am Coll Cardiol , vol.58 , pp. 1844-1854
    • Park, K.W.1    Chae, I.H.2    Lim, D.S.3
  • 21
    • 33750988757 scopus 로고    scopus 로고
    • Probucol inhibits in-stent thrombosis and neointimal hyperplasia by promoting re-endothelialization
    • et al.
    • Tanous D, Brasen JH, Choy K, et al. Probucol inhibits in-stent thrombosis and neointimal hyperplasia by promoting re-endothelialization. Atherosclerosis 2006; 189: 342-349.
    • (2006) Atherosclerosis , vol.189 , pp. 342-349
    • Tanous, D.1    Brasen, J.H.2    Choy, K.3
  • 22
    • 14344271133 scopus 로고    scopus 로고
    • Lack of neointimal proliferation after implantation of sirolimus-coated stents in human coronary arteries: A quantitative coronary angiography and three-dimensional intravascular ultrasound study
    • et al.
    • Sousa JE, Costa MA, Abizaid A, et al. Lack of neointimal proliferation after implantation of sirolimus-coated stents in human coronary arteries: a quantitative coronary angiography and three-dimensional intravascular ultrasound study. Circulation 2001; 103: 192-195.
    • (2001) Circulation , vol.103 , pp. 192-195
    • Sousa, J.E.1    Costa, M.A.2    Abizaid, A.3
  • 23
    • 29544433982 scopus 로고    scopus 로고
    • First-in-human study of the Endeavor ABT-578-eluting phosphorylcholine- encapsulated stent system in de novo native coronary artery lesions: Endeavor i Trial
    • et al.
    • Meredith IT, Ormiston J, Whitbourn R, et al. First-in-human study of the Endeavor ABT-578-eluting phosphorylcholine-encapsulated stent system in de novo native coronary artery lesions: Endeavor I Trial. EuroIntervention 2005; 1: 157-164.
    • (2005) EuroIntervention , vol.1 , pp. 157-164
    • Meredith, I.T.1    Ormiston, J.2    Whitbourn, R.3
  • 24
    • 24944555083 scopus 로고    scopus 로고
    • A randomized comparison of a durable polymer Everolimus-eluting stent with a bare metal coronary stent: The SPIRIT first trial
    • et al.
    • Serruys PW, Ong AT, Piek JJ, et al. A randomized comparison of a durable polymer Everolimus-eluting stent with a bare metal coronary stent: The SPIRIT first trial. EuroIntervention 2005; 1: 58-65.
    • (2005) EuroIntervention , vol.1 , pp. 58-65
    • Serruys, P.W.1    Ong, A.T.2    Piek, J.J.3
  • 25
    • 42049104505 scopus 로고    scopus 로고
    • The next-generation Endeavor Resolute stent: 4-month clinical and angiographic results from the Endeavor Resolute first-in-man trial
    • et al.
    • Meredith IT, Worthley S, Whitbourn R, et al. The next-generation Endeavor Resolute stent: 4-month clinical and angiographic results from the Endeavor Resolute first-in-man trial. EuroIntervention 2007; 1: 50-53.
    • (2007) EuroIntervention , vol.1 , pp. 50-53
    • Meredith, I.T.1    Worthley, S.2    Whitbourn, R.3
  • 26
    • 65549099770 scopus 로고    scopus 로고
    • A randomized optical coherence tomography study of coronary stent strut coverage and luminal protrusion with rapamycin-eluting stents
    • et al.
    • Moore P, Barlis P, Spiro J, et al. A randomized optical coherence tomography study of coronary stent strut coverage and luminal protrusion with rapamycin-eluting stents. J Am Coll Cardiol Intv 2009; 2: 437-444.
    • (2009) J Am Coll Cardiol Intv , vol.2 , pp. 437-444
    • Moore, P.1    Barlis, P.2    Spiro, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.