Volumn 57, Issue 4, 2011, Pages 390-398

Coronary responses and differential mechanisms of late stent thrombosis attributed to first-generation sirolimus- and paclitaxel-eluting stents

Author keywords

bare metal stent(s); BMS; DES; drug eluting stent(s); late stent thrombosis; LST; paclitaxel eluting stent(s); PES; SES; sirolimus eluting stent(s)

Indexed keywords

FIBRIN; PACLITAXEL; RAPAMYCIN;

EID: 78751623656     PISSN: 07351097     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jacc.2010.05.066     Document Type: Article
Times cited : (279)

References (34)
  • 1
    • 0141765805 scopus 로고    scopus 로고
    • Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery
    • J.W. Moses, M.B. Leon, and J.J. Popma Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery N Engl J Med 349 2003 1315 1323
    • (2003) N Engl J Med , vol.349 , pp. 1315-1323
    • Moses, J.W.1    Leon, M.B.2    Popma, J.J.3
  • 2
    • 9144249927 scopus 로고    scopus 로고
    • A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease
    • G.W. Stone, S.G. Ellis, and D.A. Cox A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease N Engl J Med 350 2004 221 231
    • (2004) N Engl J Med , vol.350 , pp. 221-231
    • Stone, G.W.1    Ellis, S.G.2    Cox, D.A.3
  • 3
    • 33745233024 scopus 로고    scopus 로고
    • Pathology of drug-eluting stents in humans: Delayed healing and late thrombotic risk
    • M. Joner, A.V. Finn, and A. Farb Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk J Am Coll Cardiol 48 2006 193 202
    • (2006) J Am Coll Cardiol , vol.48 , pp. 193-202
    • Joner, M.1    Finn, A.V.2    Farb, A.3
  • 4
    • 33847167065 scopus 로고    scopus 로고
    • Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: Data from a large two-institutional cohort study
    • J. Daemen, P. Wenaweser, and K. Tsuchida Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: data from a large two-institutional cohort study Lancet 369 2007 667 678
    • (2007) Lancet , vol.369 , pp. 667-678
    • Daemen, J.1    Wenaweser, P.2    Tsuchida, K.3
  • 5
    • 23844482954 scopus 로고    scopus 로고
    • Sirolimus-eluting and paclitaxel-eluting stents for coronary revascularization
    • S. Windecker, A. Remondino, and F.R. Eberli Sirolimus-eluting and paclitaxel-eluting stents for coronary revascularization N Engl J Med 353 2005 653 662
    • (2005) N Engl J Med , vol.353 , pp. 653-662
    • Windecker, S.1    Remondino, A.2    Eberli, F.R.3
  • 6
    • 34248219973 scopus 로고    scopus 로고
    • Pathological correlates of late drug-eluting stent thrombosis: Strut coverage as a marker of endothelialization
    • A.V. Finn, M. Joner, and G. Nakazawa Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization Circulation 115 2007 2435 2441
    • (2007) Circulation , vol.115 , pp. 2435-2441
    • Finn, A.V.1    Joner, M.2    Nakazawa, G.3
  • 7
    • 34247558672 scopus 로고    scopus 로고
    • Clinical end points in coronary stent trials: A case for standardized definitions
    • D.E. Cutlip, S. Windecker, and R. Mehran Clinical end points in coronary stent trials: a case for standardized definitions Circulation 115 2007 2344 2351
    • (2007) Circulation , vol.115 , pp. 2344-2351
    • Cutlip, D.E.1    Windecker, S.2    Mehran, R.3
  • 8
    • 54049125008 scopus 로고    scopus 로고
    • Delayed arterial healing and increased late stent thrombosis at culprit sites after drug-eluting stent placement for acute myocardial infarction patients: An autopsy study
    • G. Nakazawa, A.V. Finn, and M. Joner Delayed arterial healing and increased late stent thrombosis at culprit sites after drug-eluting stent placement for acute myocardial infarction patients: an autopsy study Circulation 118 2008 1138 1145
    • (2008) Circulation , vol.118 , pp. 1138-1145
    • Nakazawa, G.1    Finn, A.V.2    Joner, M.3
  • 10
    • 33847149285 scopus 로고    scopus 로고
    • Prevention of premature discontinuation of dual antiplatelet therapy in patients with coronary artery stents: A science advisory from the American Heart Association, American College of Cardiology, Society for Cardiovascular Angiography and Interventions, American College of Surgeons, and American Dental Association, with representation from the American College of Physicians
    • C.L. Grines, R.O. Bonow, and D.E. Casey Jr. Prevention of premature discontinuation of dual antiplatelet therapy in patients with coronary artery stents: a science advisory from the American Heart Association, American College of Cardiology, Society for Cardiovascular Angiography and Interventions, American College of Surgeons, and American Dental Association, with representation from the American College of Physicians Circulation 115 2007 813 818
    • (2007) Circulation , vol.115 , pp. 813-818
    • Grines, C.L.1    Bonow, R.O.2    Casey Jr., D.E.3
  • 11
    • 38549120402 scopus 로고    scopus 로고
    • A comparison of bare-metal and drug-eluting stents for off-label indications
    • O.C. Marroquin, F. Selzer, and S.R. Mulukutla A comparison of bare-metal and drug-eluting stents for off-label indications N Engl J Med 358 2008 342 352
    • (2008) N Engl J Med , vol.358 , pp. 342-352
    • Marroquin, O.C.1    Selzer, F.2    Mulukutla, S.R.3
  • 12
    • 59049099699 scopus 로고    scopus 로고
    • Drug-eluting stent safety: Findings from preclinical studies
    • G. Nakazawa, A.V. Finn, and E. Ladich Drug-eluting stent safety: findings from preclinical studies Expert Rev Cardiovasc Ther 6 2008 1379 1391
    • (2008) Expert Rev Cardiovasc Ther , vol.6 , pp. 1379-1391
    • Nakazawa, G.1    Finn, A.V.2    Ladich, E.3
  • 13
    • 10744229988 scopus 로고    scopus 로고
    • Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: Should we be cautious?
    • R. Virmani, G. Guagliumi, and A. Farb Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious? Circulation 109 2004 701 705
    • (2004) Circulation , vol.109 , pp. 701-705
    • Virmani, R.1    Guagliumi, G.2    Farb, A.3
  • 14
    • 0035943063 scopus 로고    scopus 로고
    • Pathological analysis of local delivery of paclitaxel via a polymer-coated stent
    • A. Farb, P.F. Heller, and S. Shroff Pathological analysis of local delivery of paclitaxel via a polymer-coated stent Circulation 104 2001 473 479
    • (2001) Circulation , vol.104 , pp. 473-479
    • Farb, A.1    Heller, P.F.2    Shroff, S.3
  • 15
    • 14344268774 scopus 로고    scopus 로고
    • Paclitaxel stent coating inhibits neointimal hyperplasia at 4 weeks in a porcine model of coronary restenosis
    • A.W. Heldman, L. Cheng, and G.M. Jenkins Paclitaxel stent coating inhibits neointimal hyperplasia at 4 weeks in a porcine model of coronary restenosis Circulation 103 2001 2289 2295
    • (2001) Circulation , vol.103 , pp. 2289-2295
    • Heldman, A.W.1    Cheng, L.2    Jenkins, G.M.3
  • 16
    • 24944585578 scopus 로고    scopus 로고
    • Late incomplete stent apposition after sirolimus-eluting stent implantation: A serial intravascular ultrasound analysis
    • J. Ako, Y. Morino, and Y. Honda Late incomplete stent apposition after sirolimus-eluting stent implantation: a serial intravascular ultrasound analysis J Am Coll Cardiol 46 2005 1002 1005
    • (2005) J Am Coll Cardiol , vol.46 , pp. 1002-1005
    • Ako, J.1    Morino, Y.2    Honda, Y.3
  • 17
    • 20044363609 scopus 로고    scopus 로고
    • Incomplete stent apposition after implantation of paclitaxel-eluting stents or bare metal stents: Insights from the randomized TAXUS II trial
    • K. Tanabe, P.W. Serruys, and M. Degertekin Incomplete stent apposition after implantation of paclitaxel-eluting stents or bare metal stents: insights from the randomized TAXUS II trial Circulation 111 2005 900 905
    • (2005) Circulation , vol.111 , pp. 900-905
    • Tanabe, K.1    Serruys, P.W.2    Degertekin, M.3
  • 18
    • 34248227700 scopus 로고    scopus 로고
    • Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation
    • S. Cook, P. Wenaweser, and M. Togni Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation Circulation 115 2007 2426 2434
    • (2007) Circulation , vol.115 , pp. 2426-2434
    • Cook, S.1    Wenaweser, P.2    Togni, M.3
  • 19
    • 77952378647 scopus 로고    scopus 로고
    • Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis
    • A.K. Hassan, S.C. Bergheanu, and T. Stijnen Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis Eur Heart J 31 2010 1172 1180
    • (2010) Eur Heart J , vol.31 , pp. 1172-1180
    • Hassan, A.K.1    Bergheanu, S.C.2    Stijnen, T.3
  • 21
    • 33847736642 scopus 로고    scopus 로고
    • Safety and efficacy of sirolimus- and paclitaxel-eluting coronary stents
    • G.W. Stone, J.W. Moses, and S.G. Ellis Safety and efficacy of sirolimus- and paclitaxel-eluting coronary stents N Engl J Med 356 2007 998 1008
    • (2007) N Engl J Med , vol.356 , pp. 998-1008
    • Stone, G.W.1    Moses, J.W.2    Ellis, S.G.3
  • 22
    • 22144474043 scopus 로고    scopus 로고
    • Differential response of delayed healing and persistent inflammation at sites of overlapping sirolimus- or paclitaxel-eluting stents
    • A.V. Finn, F.D. Kolodgie, and J. Harnek Differential response of delayed healing and persistent inflammation at sites of overlapping sirolimus- or paclitaxel-eluting stents Circulation 112 2005 270 278
    • (2005) Circulation , vol.112 , pp. 270-278
    • Finn, A.V.1    Kolodgie, F.D.2    Harnek, J.3
  • 23
    • 67849105772 scopus 로고    scopus 로고
    • Lack of association between large angiographic late loss and low risk of in-stent thrombus: Angioscopic comparison between paclitaxel- and sirolimus-eluting stents
    • M. Takano, M. Yamamoto, and D. Murakami Lack of association between large angiographic late loss and low risk of in-stent thrombus: angioscopic comparison between paclitaxel- and sirolimus-eluting stents Circ Cardiovasc Interv 1 2008 20 27
    • (2008) Circ Cardiovasc Interv , vol.1 , pp. 20-27
    • Takano, M.1    Yamamoto, M.2    Murakami, D.3
  • 24
    • 4344686717 scopus 로고    scopus 로고
    • Extracellular matrix changes in stented human coronary arteries
    • A. Farb, F.D. Kolodgie, and J.Y. Hwang Extracellular matrix changes in stented human coronary arteries Circulation 110 2004 940 947
    • (2004) Circulation , vol.110 , pp. 940-947
    • Farb, A.1    Kolodgie, F.D.2    Hwang, J.Y.3
  • 25
    • 13344293686 scopus 로고    scopus 로고
    • Three-year follow-up after implantation of metallic coronary-artery stents
    • T. Kimura, H. Yokoi, and Y. Nakagawa Three-year follow-up after implantation of metallic coronary-artery stents N Engl J Med 334 1996 561 566
    • (1996) N Engl J Med , vol.334 , pp. 561-566
    • Kimura, T.1    Yokoi, H.2    Nakagawa, Y.3
  • 26
    • 27444446163 scopus 로고    scopus 로고
    • Evaluation of four-year coronary artery response after sirolimus-eluting stent implantation using serial quantitative intravascular ultrasound and computer-assisted grayscale value analysis for plaque composition in event-free patients
    • J. Aoki, A.C. Abizaid, and P.W. Serruys Evaluation of four-year coronary artery response after sirolimus-eluting stent implantation using serial quantitative intravascular ultrasound and computer-assisted grayscale value analysis for plaque composition in event-free patients J Am Coll Cardiol 46 2005 1670 1676
    • (2005) J Am Coll Cardiol , vol.46 , pp. 1670-1676
    • Aoki, J.1    Abizaid, A.C.2    Serruys, P.W.3
  • 27
    • 33644877576 scopus 로고    scopus 로고
    • Persistent remodeling and neointimal suppression 2 years after polymer-based, paclitaxel-eluting stent implantation: Insights from serial intravascular ultrasound analysis in the TAXUS II study
    • J. Aoki, A. Colombo, and D. Dudek Persistent remodeling and neointimal suppression 2 years after polymer-based, paclitaxel-eluting stent implantation: insights from serial intravascular ultrasound analysis in the TAXUS II study Circulation 112 2005 3876 3883
    • (2005) Circulation , vol.112 , pp. 3876-3883
    • Aoki, J.1    Colombo, A.2    Dudek, D.3
  • 28
    • 34648847091 scopus 로고    scopus 로고
    • Long-term clinical outcomes with sirolimus-eluting coronary stents: Five-year results of the RAVEL trial
    • M.C. Morice, P.W. Serruys, and P. Barragan Long-term clinical outcomes with sirolimus-eluting coronary stents: five-year results of the RAVEL trial J Am Coll Cardiol 50 2007 1299 1304
    • (2007) J Am Coll Cardiol , vol.50 , pp. 1299-1304
    • Morice, M.C.1    Serruys, P.W.2    Barragan, P.3
  • 29
    • 20844442291 scopus 로고    scopus 로고
    • Four-year angiographic and intravascular ultrasound follow-up of patients treated with sirolimus-eluting stents
    • J.E. Sousa, M.A. Costa, and A. Abizaid Four-year angiographic and intravascular ultrasound follow-up of patients treated with sirolimus-eluting stents Circulation 111 2005 2326 2329
    • (2005) Circulation , vol.111 , pp. 2326-2329
    • Sousa, J.E.1    Costa, M.A.2    Abizaid, A.3
  • 30
    • 0020079036 scopus 로고
    • Effects of fibrin and fibrinogen-degradation products on the growth of rabbit aortic smooth muscle cells in culture
    • T. Ishida, and K. Tanaka Effects of fibrin and fibrinogen-degradation products on the growth of rabbit aortic smooth muscle cells in culture Atherosclerosis 44 1982 161 174
    • (1982) Atherosclerosis , vol.44 , pp. 161-174
    • Ishida, T.1    Tanaka, K.2
  • 31
    • 0034655148 scopus 로고    scopus 로고
    • Smooth muscle cell outgrowth stimulated by fibrin degradation products: The potential role of fibrin fragment e in restenosis and atherogenesis
    • M. Naito, C.M. Stirk, E.B. Smith, and W.D. Thompson Smooth muscle cell outgrowth stimulated by fibrin degradation products The potential role of fibrin fragment E in restenosis and atherogenesis Thromb Res 98 2000 165 174
    • (2000) Thromb Res , vol.98 , pp. 165-174
    • Naito, M.1    Stirk, C.M.2    Smith, E.B.3    Thompson, W.D.4
  • 32
    • 67651119696 scopus 로고    scopus 로고
    • Comparison of inflammatory response after implantation of sirolimus- and paclitaxel-eluting stents in porcine coronary arteries
    • G.J. Wilson, G. Nakazawa, and R.S. Schwartz Comparison of inflammatory response after implantation of sirolimus- and paclitaxel-eluting stents in porcine coronary arteries Circulation 120 2009 141 149 12
    • (2009) Circulation , vol.120 , pp. 141-149
    • Wilson, G.J.1    Nakazawa, G.2    Schwartz, R.S.3
  • 34
    • 0037172986 scopus 로고    scopus 로고
    • Morphological predictors of restenosis after coronary stenting in humans
    • A. Farb, D.K. Weber, F.D. Kolodgie, A.P. Burke, and R. Virmani Morphological predictors of restenosis after coronary stenting in humans Circulation 105 2002 2974 2980
    • (2002) Circulation , vol.105 , pp. 2974-2980
    • Farb, A.1    Weber, D.K.2    Kolodgie, F.D.3    Burke, A.P.4    Virmani, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.