3
-
-
40849097595
-
Sweep frequency response analysis (SFRA) for the assessment of winding displacements and deformation in power transformers
-
DOI 10.1016/j.epsr.2007.08.005, PII S037877960700171X
-
J. Secure, and E. Mombello Sweep frequency response analysis for the assessment of winding displacements and deformation in power transformers Electr Power Syst Res 78 6 2008 1119 1128 (Pubitemid 351400335)
-
(2008)
Electric Power Systems Research
, vol.78
, Issue.6
, pp. 1119-1128
-
-
Secue, J.R.1
Mombello, E.2
-
5
-
-
33845661438
-
Winding movement in power transformers: A comparison of FRA measurement connection methods
-
DOI 10.1109/TDEI.2006.258206
-
J.A.S.B. Jayasinghe, Z.D. Wang, P.N. Jarman, and A.W. Darwin Winding movement in power transformers: a comparison of FRA measurement connection methods IEEE Trans Dielectr Electr Insul 13 6 2006 1342 1349 (Pubitemid 44956068)
-
(2006)
IEEE Transactions on Dielectrics and Electrical Insulation
, vol.13
, Issue.6
, pp. 1342-1349
-
-
Jayasinghe, J.A.S.B.1
Wang, Z.D.2
Jarman, P.N.3
Darwin, A.W.4
-
6
-
-
84893413103
-
Experience with SFRA for transformer diagnostics
-
Mcgrail T, Sweester C. Experience with SFRA for transformer diagnostics. In: Doble conference; 2003.
-
(2003)
Doble Conference
-
-
McGrail, T.1
Sweester, C.2
-
7
-
-
84893405480
-
Investigations on two 28 MVA mobile units using sweep frequency response analysis
-
P. Prout, M. Lawrence, C. Sweester, T. McGrail, Investigations on two 28 MVA mobile units using sweep frequency response analysis, Doble conference; 2004.
-
(2004)
Doble Conference
-
-
Prout, P.1
Lawrence, M.2
Sweester, C.3
McGrail, T.4
-
8
-
-
42249085204
-
Identification of terminal connection and system function for sensitive frequency response measurement on transformers
-
DOI 10.1109/TPWRD.2008.915808
-
L. Satish, and A. Saravanakumar Identification of terminal connection and system function for sensitive frequency response measurement on transformers IEEE Trans Power Deliv 23 2 2008 742 750 (Pubitemid 351546125)
-
(2008)
IEEE Transactions on Power Delivery
, vol.23
, Issue.2
, pp. 742-750
-
-
Satish, L.1
Saravanakumar, A.2
-
9
-
-
42349088830
-
Localization of changes in a model winding based on terminal measurements: An experimental study
-
K. Ragavan, and L. Satish Localization of changes in a model winding based on terminal measurements: an experimental study IEEE Trans Dielectr Electr Insul 22 3 2007 1557 1565
-
(2007)
IEEE Trans Dielectr Electr Insul
, vol.22
, Issue.3
, pp. 1557-1565
-
-
Ragavan, K.1
Satish, L.2
-
10
-
-
79960522486
-
Localization on discrete change in a transformer winding: A network-function-loci approach
-
S. Pramnik, and L. Satish Localization on discrete change in a transformer winding: a network-function-loci approach IET Electr Power Appl 5 6 2010 540 548
-
(2010)
IET Electr Power Appl
, vol.5
, Issue.6
, pp. 540-548
-
-
Pramnik, S.1
Satish, L.2
-
11
-
-
80054083071
-
Modelling of power transformers to support the interpretation of frequency response analysis
-
S.D. Mitchell, and J.S. Welsch Modelling of power transformers to support the interpretation of frequency response analysis IEEE Trans Dielectr Electr Insul 26 4 2011 2707 2717
-
(2011)
IEEE Trans Dielectr Electr Insul
, vol.26
, Issue.4
, pp. 2707-2717
-
-
Mitchell, S.D.1
Welsch, J.S.2
-
12
-
-
0027555047
-
Influence of secondary winding terminal conditions on impulse distribution in transformer windings
-
S. Jayaram Influence of secondary winding terminal conditions on impulse distribution in transformer windings Electrl Mach Power Syst 21 3 1993 183 198
-
(1993)
Electrl Mach Power Syst
, vol.21
, Issue.3
, pp. 183-198
-
-
Jayaram, S.1
-
14
-
-
80455143572
-
Resonant behavior of EHV transformer windings under system originated oscillatory transient over voltages
-
Poulomi Mitra, Abhinandan De, and Abhijit Chakrabarti Resonant behavior of EHV transformer windings under system originated oscillatory transient over voltages Int J Electr Power Energy Syst 33 10 2011 1760 1766
-
(2011)
Int J Electr Power Energy Syst
, vol.33
, Issue.10
, pp. 1760-1766
-
-
Mitra, P.1
De, A.2
Chakrabarti, A.3
-
15
-
-
0018038144
-
Transformer diagnostic testing by frequency response analysis
-
E.P. Dick, and C.C. Erven Transformer diagnostic testing by frequency response analysis IEEE Trans Power Apparat Syst PAS-97 6 1978 2144 2153 (Pubitemid 9413502)
-
(1978)
IEEE Trans Power Appar Syst
, vol.PAS-97
, Issue.6
, pp. 2144-2153
-
-
Dick, E.P.1
Erven Clifford, C.2
-
16
-
-
84893356580
-
What terminal configuration to use for SFR measurements on single phase and three phase transformers
-
October 24
-
Satish L, Saravanakumar A. What terminal configuration to use for SFR measurements on single phase and three phase transformers. In: CIGRE SC A1 and D1 joint colloquium, October 24, 2007. p. 1-8.
-
(2007)
CIGRE SC A1 and D1 Joint Colloquium
, pp. 1-8
-
-
Satish, L.1
Saravanakumar, A.2
-
17
-
-
84893379497
-
Best terminal configuration for making sensitive sweep frequency response measurement on transformers
-
IWD, Korea
-
Satish L, Saravanakumar A. Best terminal configuration for making sensitive sweep frequency response measurement on transformers. In: CIGRE WG D1.33. IWD, Korea; 2007. p. 1-8.
-
(2007)
CIGRE WG D1.33
, pp. 1-8
-
-
Satish, L.1
Saravanakumar, A.2
-
18
-
-
5044247505
-
Transformer winding movement monitoring in service-key factors affecting FRA measurements
-
M. Wang, and A.J. Vandermaar Transformer winding movement monitoring in service-key factors affecting FRA measurements IEEE Electr Insul Magaz 20 5 2004 5 12
-
(2004)
IEEE Electr Insul Magaz
, vol.20
, Issue.5
, pp. 5-12
-
-
Wang, M.1
Vandermaar, A.J.2
-
19
-
-
23944492606
-
Improved detection of power transformer winding movement by extending the FRA high frequency range
-
DOI 10.1109/TPWRD.2005.848674
-
M. Wang, and A.J. Vandermaar Improved detection of power transformer winding movement by extending the FRA high frequency range IEEE Trans Power Deliv 20 3 2005 1930 1938 (Pubitemid 41194795)
-
(2005)
IEEE Transactions on Power Delivery
, vol.20
, Issue.3
, pp. 1930-1938
-
-
Wang, M.1
Vandermaar, A.J.2
Srivastava, K.D.3
-
20
-
-
0037396221
-
Transfer function method to diagnose axial displacement and radial deformation of transformer windings
-
E. Rahimpour, J. Christian, K. Feser, and H. Mohesin Transfer function method to diagnose axial displacement and radial deformation of transformer windings IEEE Trans Power Deliv 18 2 2003 493 505
-
(2003)
IEEE Trans Power Deliv
, vol.18
, Issue.2
, pp. 493-505
-
-
Rahimpour, E.1
Christian, J.2
Feser, K.3
Mohesin, H.4
-
21
-
-
0345276784
-
Detection of transformer winding deformations based on the transfer function - Measurements and simulations
-
DOI 10.1088/0957-0233/14/11/017, PII S0957023303659047
-
M. Florkowski, and J. Furgal "Detection of transformer winding deformations based on the transfer function-measurements and simulations Measur Sci Technol 2003 1986 1992 (Pubitemid 37477347)
-
(2003)
Measurement Science and Technology
, vol.14
, Issue.11
, pp. 1986-1992
-
-
Florkowski, M.1
Furgal, J.2
-
22
-
-
42249083386
-
Influence of phase connections and terminal conditions on natural frequencies of three phase transformer windings
-
B.I. Gururaj Influence of phase connections and terminal conditions on natural frequencies of three phase transformer windings IEEE Trans Power Apparat Syst 87 3 1968 1 12
-
(1968)
IEEE Trans Power Apparat Syst
, vol.87
, Issue.3
, pp. 1-12
-
-
Gururaj, B.I.1
-
23
-
-
33745159788
-
Natural Frequencies of three phase transformer windings
-
B.I. Gururaj Natural Frequencies of three phase transformer windings AIEE Trans Electr Eng 1963 318 329
-
(1963)
AIEE Trans Electr Eng
, pp. 318-329
-
-
Gururaj, B.I.1
-
24
-
-
0024144489
-
Natural frequencies and transient responses of three phase transformer windings
-
K.H. Sheshkamal Natural frequencies and transient responses of three phase transformer windings Electr Mach Power Syst 15 3 1988 183 198
-
(1988)
Electr Mach Power Syst
, vol.15
, Issue.3
, pp. 183-198
-
-
Sheshkamal, K.H.1
-
25
-
-
0036650904
-
Structure of transfer function of transformers with special reference to interleaved windings
-
L. Satish, and A. Jain Structure of transfer function of transformers with special reference to interleaved windings IEEE Trans Power Deliv 17 3 2002 754 760
-
(2002)
IEEE Trans Power Deliv
, vol.17
, Issue.3
, pp. 754-760
-
-
Satish, L.1
Jain, A.2
-
26
-
-
84860844671
-
Effects of terminal connections on sweep frequency response analysis of transformers
-
Esam Al Murawwi, Redy Mardiana, and Charles Q. Su Effects of terminal connections on sweep frequency response analysis of transformers IEEE Electr Insul Magaz 28 3 2012 8 13
-
(2012)
IEEE Electr Insul Magaz
, vol.28
, Issue.3
, pp. 8-13
-
-
Murawwi, E.A.1
Mardiana, R.2
Su, C.Q.3
-
27
-
-
77953732211
-
Identification of the most sensitive frequency response measurement technique for diagnosis of inter-turn faults in power transformers
-
V. Behjat, A. Vahedi1, A. Setayeshmehr, H. Borsi, and E. Gockenbach Identification of the most sensitive frequency response measurement technique for diagnosis of inter-turn faults in power transformers Measur Sci Technol 21 7 2010 1 14
-
(2010)
Measur Sci Technol
, vol.21
, Issue.7
, pp. 1-14
-
-
Behjat, V.1
Vahedi, A.2
Setayeshmehr, A.3
Borsi, H.4
Gockenbach, E.5
-
28
-
-
84860546707
-
Sweep frequency response analysis for diagnosis of low level short circuit faults on the windings of power transformer: An experimental study
-
V. Behjat, A. Vahedi1, A. Setayeshmehr, H. Borsi, and E. Gockenbach Sweep frequency response analysis for diagnosis of low level short circuit faults on the windings of power transformer: an experimental study Int J Electr Power Energy Syst 42 1 2012 78 90
-
(2012)
Int J Electr Power Energy Syst
, vol.42
, Issue.1
, pp. 78-90
-
-
Behjat, V.1
Vahedi, A.2
Setayeshmehr, A.3
Borsi, H.4
Gockenbach, E.5
|