-
1
-
-
0020753767
-
"An international survey on failures in large power transformers in service"
-
CIGRE Working Group 05
-
CIGRE Working Group 05, "An international survey on failures in large power transformers in service," Electra, no. 88, 1983.
-
(1983)
Electra
, Issue.88
-
-
-
2
-
-
0003190002
-
"Lifetime evaluation of transformers"
-
CIGRE Working Group 09 of Study Committee 12
-
CIGRE Working Group 09 of Study Committee 12, "Lifetime evaluation of transformers," Electra, no. 150, pp. 39-51, 1993.
-
(1993)
Electra
, Issue.150
, pp. 39-51
-
-
-
3
-
-
0030193908
-
"Status and trends in transformer monitoring"
-
Jul.
-
C. Bengtsson, "Status and trends in transformer monitoring," IEEE Trans. Power Del., vol. 11, no. 3, pp. 1379-1384, Jul. 1996.
-
(1996)
IEEE Trans. Power Del.
, vol.11
, Issue.3
, pp. 1379-1384
-
-
Bengtsson, C.1
-
4
-
-
5044240981
-
"The transfer function method for detection of winding displacements on power transformers after transport, short circuit or 30 years service"
-
paper 12/33-04
-
K. Feser et al., "The transfer function method for detection of winding displacements on power transformers after transport, short circuit or 30 years service," in CIGRE, 2000, paper 12/33-04.
-
(2000)
CIGRE
-
-
Feser, K.1
-
5
-
-
0013273314
-
"Frequency response analysis as a diagnostic tool"
-
E. Hanique, H. F. Reijnders, and P. T. M. Vaessen, "Frequency response analysis as a diagnostic tool," J. Elektotechniek, vol. 68, no. 6, pp. 549-558, 1990.
-
(1990)
J. Elektotechniek
, vol.68
, Issue.6
, pp. 549-558
-
-
Hanique, E.1
Reijnders, H.F.2
Vaessen, P.T.M.3
-
6
-
-
0033207342
-
"Monitoring of power transformers using the transfer function method"
-
Oct.
-
T. Leibfried and K. Feser, "Monitoring of power transformers using the transfer function method," IEEE Trans. Power Delivery, vol. 14, no. 4, pp. 1333-1341, Oct. 1999.
-
(1999)
IEEE Trans. Power Delivery
, vol.14
, Issue.4
, pp. 1333-1341
-
-
Leibfried, T.1
Feser, K.2
-
7
-
-
0013273317
-
"Transformer condition monitoring by frequency response analysis"
-
Montreal, QC, Canada
-
A. J. Vandermaar and M. Wang, "Transformer condition monitoring by frequency response analysis," in Proc. 10th Int. Symp. High Voltage Engineering, vol. 4, Montreal, QC, Canada, 1997, pp. 119-122.
-
(1997)
Proc. 10th Int. Symp. High Voltage Engineering
, vol.4
, pp. 119-122
-
-
Vandermaar, A.J.1
Wang, M.2
-
8
-
-
0013253618
-
"Transformer condition monitoring by the low voltage impulse test method"
-
Johannesburg, South Africa
-
M. Wang, A. J. Vandermaar, and K. D. Srivastava, "Transformer condition monitoring by the low voltage impulse test method," in Proc. CIGRE Third South African Regional Conf.. Johannesburg, South Africa, 1998.
-
(1998)
Proc. CIGRE Third South African Regional Conf.
-
-
Wang, M.1
Vandermaar, A.J.2
Srivastava, K.D.3
-
9
-
-
27944506017
-
"Comparison of two FRA methods to detect transformer winding movement"
-
New Orleans, LA
-
R. J. Denis, S. K. An, J. Vandermaar, and M. Wang, "Comparison of two FRA methods to detect transformer winding movement," in Proc. EPRI Substation Equipment Diagnostics Conf. VIII, New Orleans, LA, 2000.
-
(2000)
Proc. EPRI Substation Equipment Diagnostics Conf. VIII
-
-
Denis, R.J.1
An, S.K.2
Vandermaar, J.3
Wang, M.4
-
10
-
-
0018038144
-
"Transformer diagnostic testing by frequency response analysis"
-
Nov./Dec.
-
E. P. Dick and C. C. Erven, "Transformer diagnostic testing by frequency response analysis," IEEE Trans. Power App. Syst., vol. PAS-97, no. 6, pp. 2144-2153, Nov./Dec. 1978.
-
(1978)
IEEE Trans. Power App. Syst.
, vol.PAS-97
, Issue.6
, pp. 2144-2153
-
-
Dick, E.P.1
Erven, C.C.2
-
11
-
-
0345150451
-
"Detecting transformer winding damage - The low voltage impulse method"
-
W. Lech and L. Tyminski, "Detecting transformer winding damage - the low voltage impulse method," Elect. Rev., no. 18, 1966.
-
(1966)
Elect. Rev.
, Issue.18
-
-
Lech, W.1
Tyminski, L.2
-
12
-
-
0031678077
-
"Hybrid modeling of inhomogeneous transformer windings for very fast transient overvoltage studies"
-
Jan.
-
G. B. Gharehpetian, H. Mohseni, and K. Möller, "Hybrid modeling of inhomogeneous transformer windings for very fast transient overvoltage studies," IEEE Trans. Power Del., vol. 13, no. 1, pp. 157-163, Jan. 1998.
-
(1998)
IEEE Trans. Power Del.
, vol.13
, Issue.1
, pp. 157-163
-
-
Gharehpetian, G.B.1
Mohseni, H.2
Möller, K.3
-
13
-
-
33645442978
-
-
Sep./Oct.
-
IEEE Insulation Mag., vol. 20, no. 5, pp. 5-12, Sep./Oct. 2004.
-
(2004)
IEEE Insulation Mag.
, vol.20
, Issue.5
, pp. 5-12
-
-
-
14
-
-
0024087696
-
"Transformer model for high frequencies"
-
Oct.
-
P. T. M. Vaessen, "Transformer model for high frequencies," IEEE Trans. Power Del., vol. 3, no. 4, pp. 1761-1768, Oct. 1988.
-
(1988)
IEEE Trans. Power Del.
, vol.3
, Issue.4
, pp. 1761-1768
-
-
Vaessen, P.T.M.1
-
15
-
-
0029344197
-
"Simplified three-phase transformer model for electromagnetic transient studies"
-
Jul.
-
S. Chimklai and J. R. Marti, "Simplified three-phase transformer model for electromagnetic transient studies," IEEE Trans. Power Del., vol. 10, no. 3, pp. 1316-1325, Jul. 1995.
-
(1995)
IEEE Trans. Power Del.
, vol.10
, Issue.3
, pp. 1316-1325
-
-
Chimklai, S.1
Marti, J.R.2
-
16
-
-
0020142982
-
"Matrix representation of three-phase N-winding transformers for steady-state and transient studies"
-
Jun.
-
V. Brandwajn, H. Dommel, and I. Dommel, "Matrix representation of three-phase N-winding transformers for steady-state and transient studies," IEEE Trans. Power App. Syst., vol. PAS-101, no. 6, pp. 1369-1378, Jun. 1982.
-
(1982)
IEEE Trans. Power App. Syst.
, vol.PAS-101
, Issue.6
, pp. 1369-1378
-
-
Brandwajn, V.1
Dommel, H.2
Dommel, I.3
-
17
-
-
0026748004
-
"Parametric identification in potential transformer modeling"
-
Jan.
-
J. Bak-Jensen et al., "Parametric identification in potential transformer modeling," IEEE Trans. Power Del., vol. 7, no. 1, pp. 70-76, Jan. 1992.
-
(1992)
IEEE Trans. Power Del.
, vol.7
, Issue.1
, pp. 70-76
-
-
Bak-Jensen, J.1
-
18
-
-
0030197261
-
"Identification of high accurate low order state space models in the frequency domain"
-
R. N. Jacques, K. Liu, and D. W. Miller, "Identification of high accurate low order state space models in the frequency domain," Signal Process., vol. 52, pp. 195-207, 1996.
-
(1996)
Signal Process.
, vol.52
, pp. 195-207
-
-
Jacques, R.N.1
Liu, K.2
Miller, D.W.3
-
19
-
-
0028540804
-
"Parametric identification of transfer functions in the frequency domain - A survey"
-
Nov.
-
R. Pintelon et al., "Parametric identification of transfer functions in the frequency domain - a survey," IEEE Trans. Autom. Control, vol. 39, no. 11, pp. 2245-2260, Nov. 1994.
-
(1994)
IEEE Trans. Autom. Control
, vol.39
, Issue.11
, pp. 2245-2260
-
-
Pintelon, R.1
-
20
-
-
0031360522
-
"Identification of high frequency transformer equivalent circuit using Matlab from frequency domain data"
-
New Orleans, LA
-
S. M. Islam, K. M. Coates, and G. Ledwich, "Identification of high frequency transformer equivalent circuit using Matlab from frequency domain data," in Proc. IEEE IAS, Annu. Meeting, New Orleans, LA, 1997, pp. 357-364.
-
(1997)
Proc. IEEE IAS, Annu. Meeting
, pp. 357-364
-
-
Islam, S.M.1
Coates, K.M.2
Ledwich, G.3
-
21
-
-
0027224436
-
"Modeling of converter transformers using frequency domain terminal impedance measurements"
-
Jan.
-
Y. Liu et al., "Modeling of converter transformers using frequency domain terminal impedance measurements," IEEE Trans. Power Del., vol. 8, no. 1, pp. 66-72, Jan. 1993.
-
(1993)
IEEE Trans. Power Del.
, vol.8
, Issue.1
, pp. 66-72
-
-
Liu, Y.1
-
22
-
-
0035481581
-
"Frequency characteristics of single-phase two-winding transformer using distributed-parameter modeling"
-
Oct.
-
A.S. AlFuhaid, "Frequency characteristics of single-phase two-winding transformer using distributed-parameter modeling," IEEE Trans. Power Del., vol. 16, no. 4, pp. 637-642, Oct. 2001.
-
(2001)
IEEE Trans. Power Del.
, vol.16
, Issue.4
, pp. 637-642
-
-
AlFuhaid, A.S.1
-
23
-
-
0036078378
-
"A continuous parameter high frequency model based on traveling waves for transformer diagnostic purposes"
-
Boston, MA
-
A. Akbari et al., "A continuous parameter high frequency model based on traveling waves for transformer diagnostic purposes," in Proc. Conf. Rec. IEEE Int. Symp. Electrical Insulation, Boston, MA, 2002, pp. 154-157.
-
(2002)
Proc. Conf. Rec. IEEE Int. Symp. Electrical Insulation
, pp. 154-157
-
-
Akbari, A.1
-
24
-
-
85095905597
-
"A method for constructing terminal models for single-phase n-winding transformers"
-
Los Angeles, CA
-
R. C. Degeneff, "A method for constructing terminal models for single-phase n-winding transformers," in Proc. IEEE PES Summer Meeting, vol. A 78, Los Angeles, CA, 1978, p. 539-9.
-
(1978)
Proc. IEEE PES Summer Meeting
, vol.A78
, pp. 539-549
-
-
Degeneff, R.C.1
-
25
-
-
0036694108
-
"Pattern classification of impulse faults in transformers by wavelet analysis"
-
Aug.
-
P. Purkait and S. Chakravorti, "Pattern classification of impulse faults in transformers by wavelet analysis," IEEE Trans. Dielectr. Electr. Insul., vol. 9, no. 4, pp. 555-561, Aug. 2002.
-
(2002)
IEEE Trans. Dielectr. Electr. Insul.
, vol.9
, Issue.4
, pp. 555-561
-
-
Purkait, P.1
Chakravorti, S.2
|