메뉴 건너뛰기




Volumn 58, Issue , 2014, Pages 64-74

Small signal stability analysis of power systems with DFIG based wind power penetration

Author keywords

Doubly fed induction generator; Eigenvalue analysis; Power system oscillations; Wind turbine generators

Indexed keywords

AUTOMATIC VOLTAGE REGULATORS; DOUBLY FED INDUCTION GENERATOR (DFIG); DOUBLY FED INDUCTION GENERATORS; EIGENVALUE ANALYSIS; INTER-AREA OSCILLATIONS; POWER SYSTEM OSCILLATIONS; POWER SYSTEM STABILIZER (PSS); SMALL SIGNAL STABILITY ANALYSIS;

EID: 84893207162     PISSN: 01420615     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijepes.2014.01.005     Document Type: Article
Times cited : (88)

References (27)
  • 2
    • 0036575603 scopus 로고    scopus 로고
    • Doubly fed induction generator systems for wind turbines
    • DOI 10.1109/2943.999610
    • Muller S, Deicke M, De Doncker RW. Doubly fed induction generator systems for wind turbines. In: IEEE industrial application magazine; May/June, 2002. p. 26-33 (Pubitemid 34630524)
    • (2002) IEEE Industry Applications Magazine , vol.8 , Issue.3 , pp. 26-33
    • Muller, S.1    Deicke, M.2    De Doncker, R.W.3
  • 3
    • 33947418456 scopus 로고    scopus 로고
    • Direct active and reactive power control of DFIG for wind energy generation
    • DOI 10.1109/TEC.2006.875472
    • Lie Xu, and Phillip Cartwright Direct active and reactive power control of DFIG for wind energy generation IEEE Trans Energy Convers 21 3 2006 750 758 (Pubitemid 46445164)
    • (2006) IEEE Transactions on Energy Conversion , vol.21 , Issue.3 , pp. 750-758
    • Xu, L.1    Cartwright, P.2
  • 4
    • 0038519499 scopus 로고    scopus 로고
    • Dynamic modelling of doubly fed induction generator wind turbines
    • J.B. Ekanayake, L. Holdsworth, X. Wu, and N. Jenkins Dynamic modelling of doubly fed induction generator wind turbines IEEE Trans Power Syst 18 2 2003 803 809
    • (2003) IEEE Trans Power Syst , vol.18 , Issue.2 , pp. 803-809
    • Ekanayake, J.B.1    Holdsworth, L.2    Wu, X.3    Jenkins, N.4
  • 5
    • 27144509174 scopus 로고    scopus 로고
    • Modelling and small-signal analysis of a grid connected doubly-fed induction generator
    • June
    • Mei Francoise, Pal Bikash C. Modelling and small-signal analysis of a grid connected doubly-fed induction generator. In: IEEE power engineering society general meeting, vol. 3; June 2005. p. 2101-8
    • (2005) IEEE Power Engineering Society General Meeting , vol.3 , pp. 2101-2108
    • Francoise, M.1    Pal Bikash, C.2
  • 6
    • 33244493104 scopus 로고    scopus 로고
    • Modeling of the wind turbine with a doubly fed induction generator for grid integration studies
    • DOI 10.1109/TEC.2005.847958
    • Y. Lei, A. Mullane, G. Lightbody, and R. Yacamini Modeling of the wind turbine with a doubly fed induction generator for grid integration studies IEEE Trans Energy Convers 21 1 2006 257 264 (Pubitemid 43280543)
    • (2006) IEEE Transactions on Energy Conversion , vol.21 , Issue.1 , pp. 257-264
    • Lei, Y.1    Mullane, A.2    Lightbody, G.3    Yacamini, R.4
  • 7
    • 0036843254 scopus 로고    scopus 로고
    • An aggregate model of a grid-connected, large-scale, offshore wind farm for power stability investigations - Importance of windmill mechanical system
    • DOI 10.1016/S0142-0615(01)00089-8, PII S0142061501000898
    • V. Akhmatov, and H. Knudsen An aggregate model of a gridconnected, large-scale, offshore wind farm for power stability investigations-importance of windmill mechanical system Elect Power Energy Syst 24 2002 709 717 (Pubitemid 35282248)
    • (2002) International Journal of Electrical Power and Energy Systems , vol.24 , Issue.9 , pp. 709-717
    • Akhmatov, V.1    Knudsen, H.2
  • 8
    • 79951941420 scopus 로고    scopus 로고
    • Oscillatory stability and eigenvalue sensitivity analysis of a DFIG wind turbine system
    • Lihui Yang, Zhao Xu, Jacob ∅stergaard, Zhao Yang Dong, Kit Po Wong, and Xikui Ma Oscillatory stability and eigenvalue sensitivity analysis of a DFIG wind turbine system IEEE Trans Energy Convers 26 1 2011 328 339
    • (2011) IEEE Trans Energy Convers , vol.26 , Issue.1 , pp. 328-339
    • Yang, L.1    Xu, Z.2    Stergaard, J.3    Dong, Z.Y.4    Wong, K.P.5    Xikui, M.A.6
  • 9
    • 70349516087 scopus 로고    scopus 로고
    • Influence of constant speed wind turbine generator on power system oscillation
    • D. Thakur, and N. Mithulananthan Influence of constant speed wind turbine generator on power system oscillation Elect Power Compon Syst 37 2009 478 494
    • (2009) Elect Power Compon Syst , vol.37 , pp. 478-494
    • Thakur, D.1    Mithulananthan, N.2
  • 10
    • 79151479221 scopus 로고    scopus 로고
    • Control strategy to mitigate the impact of reduced inertia due to doubly fed induction generators on large power systems
    • Durga Gautam, Lalit Goel, Raja Ayyanar, Vijay Vittal, and Terry Harbour Control strategy to mitigate the impact of reduced inertia due to doubly fed induction generators on large power systems IEEE Trans Power Syst 26 1 2011 214 224
    • (2011) IEEE Trans Power Syst , vol.26 , Issue.1 , pp. 214-224
    • Gautam, D.1    Goel, L.2    Ayyanar, R.3    Vittal, V.4    Harbour, T.5
  • 11
    • 54049134008 scopus 로고    scopus 로고
    • Effect of wind parks with doubly fed asynchronous generators on small signal stability
    • G. Tsourakis, B.M. Nomikos, and C.D. Vournas Effect of wind parks with doubly fed asynchronous generators on small signal stability Elect Power Syst Res 79 2009 190 200
    • (2009) Elect Power Syst Res , vol.79 , pp. 190-200
    • Tsourakis, G.1    Nomikos, B.M.2    Vournas, C.D.3
  • 12
    • 84857654255 scopus 로고    scopus 로고
    • Coordinated tuning of DFIG-based wind turbines and batteries using bacteria foraging technique for maintaining constant grid power output
    • Y. Mishra, S. Mishra, and Fangxing Li Coordinated tuning of DFIG-based wind turbines and batteries using bacteria foraging technique for maintaining constant grid power output IEEE Syst J 6 1 2012 16 26
    • (2012) IEEE Syst J , vol.6 , Issue.1 , pp. 16-26
    • Mishra, Y.1    Mishra, S.2    Li, F.3
  • 13
    • 70049083223 scopus 로고    scopus 로고
    • Improving stability of a DFIG-based wind power system with tuned damping controller
    • Y. Mishra, S. Mishra, M. Tripathy, N. Senroy, and Z.Y. Dong Improving stability of a DFIG-based wind power system with tuned damping controller IEEE Trans Energy Convers 24 3 2009 650 660
    • (2009) IEEE Trans Energy Convers , vol.24 , Issue.3 , pp. 650-660
    • Mishra, Y.1    Mishra, S.2    Tripathy, M.3    Senroy, N.4    Dong, Z.Y.5
  • 14
    • 68349150311 scopus 로고    scopus 로고
    • Impact of increased penetration of DFIG-based wind turbine generators on transient and small signal stability of power systems
    • D. Guatam, V. Vittal, and T. Harbour Impact of increased penetration of DFIG-based wind turbine generators on transient and small signal stability of power systems IEEE Trans Power Syst 24 3 2009 1426 1434
    • (2009) IEEE Trans Power Syst , vol.24 , Issue.3 , pp. 1426-1434
    • Guatam, D.1    Vittal, V.2    Harbour, T.3
  • 15
    • 77957014951 scopus 로고    scopus 로고
    • Decoupled-DFIG fault ride-through strategy for enhanced stability performance during grid faults
    • Lasantha Gunaruwan Meegahapola, Tim Littler, and Damian Flynn Decoupled-DFIG fault ride-through strategy for enhanced stability performance during grid faults IEEE Trans Sust Energy 1 3 2010 152 162
    • (2010) IEEE Trans Sust Energy , vol.1 , Issue.3 , pp. 152-162
    • Meegahapola, L.G.1    Littler, T.2    Flynn, D.3
  • 16
    • 25144509486 scopus 로고    scopus 로고
    • Large-scale wind power integration in Norway and impact on damping in the Nordic grid
    • DOI 10.1002/we.168
    • E. Hagstrom, I. Norheim, and K. Uhlen Large-scale wind power integration in Norway and impact on damping in the Nordic grid Wind Energy J 8 3 2005 375 384 (Pubitemid 41353611)
    • (2005) Wind Energy , vol.8 , Issue.3 , pp. 375-384
    • Hagstrom, E.1    Norheim, I.2    Uhlen, K.3
  • 17
    • 33847361534 scopus 로고    scopus 로고
    • Impact of wind farms on a power system. An eigenvalue analysis approach
    • DOI 10.1016/j.renene.2006.07.009, PII S0960148106002229
    • R.D. Fernandez, R.J. Mantz, and P.E. Battaiotto Impact of wind farms on a power system: an eigenvalue analysis approach Renew Energy 32 10 2007 1676 1688 (Pubitemid 46341815)
    • (2007) Renewable Energy , vol.32 , Issue.10 , pp. 1676-1688
    • Fernandez, R.D.1    Mantz, R.J.2    Battaiotto, P.E.3
  • 18
    • 34548237470 scopus 로고    scopus 로고
    • Modal analysis of grid-connected doubly fed induction generators
    • DOI 10.1109/TEC.2006.881080
    • F. Mei, and B. Pal Modal analysis of grid-connected doubly fed induction generators IEEE Trans Energy Convers 22 3 2007 728 736 (Pubitemid 47323589)
    • (2007) IEEE Transactions on Energy Conversion , vol.22 , Issue.3 , pp. 728-736
    • Mei, F.1    Pal, B.2
  • 19
    • 0033879068 scopus 로고    scopus 로고
    • Consequence and impact of electric utility industry restructuring on transient stability and small-signal stability analysis
    • DOI 10.1109/5.823998
    • V. Vittal Consequence and impact of electric utility industry restructuring on transient stability and small-signal stability analysis Proc IEEE 88 2 2000 196 207 (Pubitemid 30558109)
    • (2000) Proceedings of the IEEE , vol.88 , Issue.2 , pp. 196-207
    • Vittal, V.1
  • 20
    • 84860737298 scopus 로고    scopus 로고
    • Penetration impact of wind farms equipped with frequency variations ride through algorithm on power system frequency response
    • A.B. Attya, and T. Hartkopf Penetration impact of wind farms equipped with frequency variations ride through algorithm on power system frequency response Int J Elect Power Energy Syst 40 2012 94 103
    • (2012) Int J Elect Power Energy Syst , vol.40 , pp. 94-103
    • Attya, A.B.1    Hartkopf, T.2
  • 21
    • 28244480269 scopus 로고    scopus 로고
    • Control of DFIG-based wind generation for power network support
    • DOI 10.1109/TPWRS.2005.857275
    • F.M. Hughes, O. Anaya-Lara, N. Jenkins, and G. Strbac Control of DFIG-based wind generation for power network support IEEE Trans Power Syst 20 4 2005 1958 1966 (Pubitemid 41700549)
    • (2005) IEEE Transactions on Power Systems , vol.20 , Issue.4 , pp. 1958-1966
    • Hughes, F.M.1    Anaya-Lara, O.2    Jenkins, N.3    Strbac, G.4
  • 25
    • 84893163278 scopus 로고    scopus 로고
    • The Math Works, Inc., version 7.8.0.347
    • MATLAB help tutorial. The Math Works, Inc., version 7.8.0.347; 2009.
    • (2009) MATLAB Help Tutorial
  • 26
    • 84860996873 scopus 로고    scopus 로고
    • The localness of electromechanical oscillations in power systems
    • Sudipta Ghosh, and Nilanjan Senroy The localness of electromechanical oscillations in power systems Int J Elect Power Energy Syst 42 2012 306 313
    • (2012) Int J Elect Power Energy Syst , vol.42 , pp. 306-313
    • Ghosh, S.1    Senroy, N.2
  • 27
    • 77955667920 scopus 로고
    • Concepts of synchronous machine stability as effected by excitation control
    • F.P. deMello, and C. Concordia Concepts of synchronous machine stability as effected by excitation control IEEE Trans Power Appl Syst PAS 88 1969 316 329
    • (1969) IEEE Trans Power Appl Syst PAS , vol.88 , pp. 316-329
    • Demello, F.P.1    Concordia, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.